• Title/Summary/Keyword: 내화 성능

Search Result 583, Processing Time 0.023 seconds

High Temperature Properties of Alumino Silicate Fire Protection Materials Using Fly ash (플라이애쉬 활용 Alumino silicate계 내화마감재의 고온특성)

  • Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu;Park, Nam-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.689-692
    • /
    • 2008
  • HSC(High Strength Concrete) have superior properties well as improvement in durability compared with normal strength concrete. In spite of durability of HSC, explosive spalling of concrete is serious problem in structure safety. Therefore, Solving methods are required to control the explosive spalling. The properties of concrete are affected by changes of temperatures. Compressive strength and elasticity modulus were degraded depending on a rise of temperatures. Also, change in microstructure and dehydration of concrete subjected to high temperatures. This paper is concerned with change in microstructure and dehydration of the alumino silicate fire protection materials at high temperatures. The testing methods of fire protection materials in high temperature properties are make use of SEM, TG-DSC and XRD. From the experimental test results, influence of high temperatures on microstructure of alumino-silicate fire protection material was identified, including chemical dehydration of C-S-H and CH. The chemical dehydration of CH under various temperatures from to 450 to 600$^{\circ}$C has been measured using the TG-DSC. However, developed alumino silicate fire protection materials showed good stability in high Temperatures. Thus, the results indicate that it is possible to fireproof panels, fire protection of materials.

  • PDF

An Experimental Study on The Fire Resistance Performance of High Strength Concrete Column mixed Fiber-Cocktail in Standard Fire Condition (하이브리드 섬유를 적용한 고강도 내화콘크리트의 단면크기에 따른 내화성능에 관한 실험적 연구)

  • Kim, Heung-Youl;Kim, Hyung-Jun;Cho, Bum-Yean;Min, Byung-Youl;Ahn, Chan-Sol
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.170-175
    • /
    • 2011
  • 최근 고강도 콘크리트의 내화성능이 사회적 이슈로 부각되고 국토해양부에서 고강도 콘크리트의 내화성능 관리기준(안)이 고시되면서 국내에서도 고강도 콘크리트의 내화성능을 향상시키기 위한 연구가 활발히 진행되고 있다. 본 연구에서는 유기질 섬유인 폴리프로필렌섬유(PP섬유)와 강섬유를 하이브리드한 Fiber Cocktail를 혼입한 고강도 내화콘크리트 개발을 위한 연구를 수행하였다. PP섬유는 $160^{\circ}C$의 온도에서 용융되어 콘크리트 내부에 미세한 통로를 형성하여 고강도 콘크리트 부재 내의 수증기압 및 공극압을 효과적으로 배출하여 고강도 콘크리트의 폭렬발생을 억제시키는 데 효과적이며, 강섬유는 PP섬유가 용융된 후의 고강도 콘크리트 부재의 균열 발생을 억제하며 외부로부터 침투하는 열기를 차단할 수 있다. 100MPa 고강도 콘크리트의 내화실험을 실시하여 최적단면 조건을 도출하기 위해 철근온도를 분석한 결과, 단면이 커질수록 철근온도는 점차 낮아지는 경향이 나타났으며 $600{\times}600mm$, $800{\times}800mm$ 단면에서 내화성능을 확보할 수 있는 것으로 나타났으며, 이중 경제성을 고려할 경우 $600{\times}600mm$ 단면이 최적단면으로 도출되었다. 또한 도출된 $600{\times}600mm$ 단면에 대해서 철근의 온도를 분석한 결과 PP섬유 $1.5kg/m^3$와 강섬유 $40kg/m^3$를 배합한 Fiber Cocktail이 최적배합비로 나타났다.

  • PDF

Evaluation of Strength and Fire Resistance Performance of Mortar Mixed with Oyster Shell and Egg Shell (굴 패각과 난각을 혼합한 모르타르의 강도 및 내화성능 평가)

  • Hae-Na Kim;Ui-In Jung;Bong-Joo Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.560-567
    • /
    • 2023
  • This study is part of the research on fire-resistant materials to prepare for changing fire behavior, oyster shell and egg shell, which are natural calcium carbonate materials, were substituted as fine aggregates. The purpose of this study was to evaluate the strength and fire resistance performance according to the substitution rate, and to provide data for use as fire resistance material. Oyster shells and egg shells were substituted with 10~50 % of the fine aggregate, respectively, and tested for strength and Simplified heating according to the KS test method. Although the strength of OS was measured to be higher than that of ES, the backside temperature was also measured to be higher. As a result, it is recommended to use fireproof boards with OS where strength performance is required, such as explosive fires, Where high fire resistance performance is required, such as high-temperature fires over 1000 ℃, fireproof boards with ES can be selected according to the application.

Evaluation of Fire Resistance of Unprotected Concrete-filled Rectangular Steel Tubular Columns under Axial Loading (재하가열시험에 의한 무내화피복 콘크리트충전 각형강관기둥의 내화성능평가)

  • Ahn, Jae Kwon;Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.323-334
    • /
    • 2014
  • In this paper, experimental program and associated numerical study were carried out to evaluate the fire resistance of unprotected concrete-filled rectangular steel tubular (CFT) columns subjected to the standard fire. The key testing parameters included the length effect, the load ratio, and the sectional dimensions of the CFT columns. Temperature distribution and axial deformation of the CFT column specimens were measured and analyzed. Rather early local buckling of steel tubes was observed in all the specimens. This caused subsequent load transfer from steel tube to concrete, and eventually triggered concrete crushing, or complete loss of the load bearing capacity of the column. This implies that the limit state of local buckling as well as overall flexural buckling should be incorporated in fire design procedure. As expected, the fire resistance time of specimen with higher load ratio consistently lessened. The prediction of fire resistance time of unprotected CFT columns based on the limiting steel temperature in current design codes or the formula proposed by previous studies is slightly conservative compared to the fire test results available. To establish the finite element analysis model that can be used to predict the thermal and structural behaviour of unprotected CFT columns in fire, the fully coupled thermal-stress analysis was also tried by using the commercial code ABAQUS. The numerical results showed a reasonable global correlation with the experimental results.

Development of Light-weight Fire Protection Materials Using Fly Ash and Light-weight Aggregate (플라이애시 및 경량골재를 활용한 경량 내화성 마감재료 개발)

  • Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu;Lee, Sea-Hyun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.95-102
    • /
    • 2012
  • The serious issue of tall building is to ensure the fire resistance of high strength concrete. Therefore, Solving methods are required to control the explosive spalling. The fire resistant finishing method is installed by applying a fire resistant material as a light-weight material to structural steel and concrete surface. This method can reduce the temperature increase of the reinforcement embedded in structural steel and concrete at high temperature due to the installation thickness control. This study is interested in identifying the effectiveness of light-weight fire protection material compounds including the inorganic admixture such as fly ash, meta-kaolin and light-weight aggregate as the fire resistant finishing materials through the analysis of fire resistance and components properties at high temperature. Also, this paper is concerned with change in microstructure and dehydration of the light-weight fire protection materials at high temperatures. The testing methods of fire protection materials in high temperature properties are make use of SEM and XRD. The study results show that the light-weight fire resistant finishing material composed of fly ash, meta-kaolin and light-weight aggregate has the thermal stability of the slight decrease of compressive strength at high temperature. These thermal stability is caused by the ceramic binding capacity induced by alkali activation reaction by the reason of the thermal analysis result not showing the decomposition of calcium hydrate. Developed light-weight fire protection materials showed good stability in high Temperatures. Thus, the results indicate that it is possible to fireproof panels, fire protection of materials.

  • PDF

An Experimental Study on Fire-Resistant Boom (내화용 오일붐의 내화성에 대한 실험적 연구)

  • Yu J.S.;Sung H.G.;Oh J.H.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.2
    • /
    • pp.25-32
    • /
    • 2000
  • Fire-resistant boom is one of the most important facilities in in situ homing of spilled oil. Thermal response of a fire-resistant boom to turning is experimentally investigated in this paper by using an electric furnace and a burning test facility. This test facility is composed of a test tank, a fire boom, a hood for inhaling smoke, an incinerator for burning up gases and thermocouples, etc. Thereby a systematic method of approach in small laboratory scale is developed to study the performance of a fire-resistant boom. Burning test is carried out for the fire boom model which has been developed through the present study. It is shown that the present fire boom model has capability to withstand the high temperature around 800℃ and high rate of heat flux on it due to homing. For more realistic experimental environments, larger dimensions in devices and longer time in experiments are recommended in near future.

  • PDF

Survey of Building Structural Elements located at Underground for Improvement of Fire Resistant Performance (건축물 지하 구조부재의 내화성능 개선에 관한 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.76-84
    • /
    • 2008
  • Researches on fire resistant performance of primary structural elements such as columns and beams located at above the ground have actively been doing than those located at the below the ground from many researchers. But the structural elements such as columns at underground is very important in aspects of not only structural performance but also fire environment. The columns at the basement carry all the structural loads from the above and that means very critical in fire circumstances than that located at above the grounds. To evaluate the fire resistance performance of primary structural elements located at below the ground we conducted several sorts of surveys that contained fire regulations from several countries and structural types, materials and status of passive fire protection methods.

Study on the Surface Temperature and Fire Protective Thickness for Structural Steel Elements at Fire Conditions (강구조 부재의 표면온도 산정 및 내화피복두께에 관한 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.55-61
    • /
    • 2010
  • Fire resistance is very essential for all buildings to save peoples who live within buildings or use and to protect the properties when the buildings are covered with fire. The fire resistance were evaluated by loading or nonloading fire tests which are known very expensive and require lots of time. That causes the lacks of research activities and there are only small cases of fire resistance. The purposes of this paper are to analyze the temperature analysis for various structural elements such as columns and beams those are can be applied to buildings and to suggest the resonable fire protective thickness of concrete slab according to the required fire resistance time.

An experimental study on the fireproof performance of fire damper in accordance with insulation conditions on the coaming and blade (코밍 방열 두께 및 블레이드 방열 유무에 따른 방화 댐퍼의 내화성능에 관한 실험적 연구)

  • Choi, Tai-Jin;Kim, Joung-Sik;Choi, Kyeong-Kwan;Lim, Young-Soo;Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.431-437
    • /
    • 2013
  • In this paper, Fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. Specimens were fabricated three different types according to the change of the insulation system applied to damper blade and coaming which were measured surface temperature by performing the fire resistance test. As a test result, specimen-1, 2 of an uninsulated damper blade were exceeded thermal insulation acceptance criteria at 21 minutes, 46 minutes respectively, but specimen-3 of an insulated damper blade was satisfied thermal insulation acceptance criteria during 120 minutes. The test results showed that the insulation of the damper blade is an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500 mm on the unexposed side as specified test standard.

Evaluation on Fire Resistance Performance of High Strength Concrete Containing Fibre (섬유혼입 고강도 콘크리트의 내화성능 평가)

  • Song, Young-Chan;Kim, Yong-Ro;Kim, Ook-Jong;Lee, Do-Bum
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.129-135
    • /
    • 2010
  • The purpose of this research is to secure fundamental data on the application of fibre as a fire resistance method for more than 60 MPa high-strength concrete through an examination of mechanical properties and fire resistance performance. The results are as follows: 1) When there are less than 0.5~1.0kg/$m^3$ contents of PP and NY fibre for 60MPa and less high strength concrete, 1.0kg/$m^3$ contents of PP and NY fibre for less than 80MPa high strength concrete and 1.5kg/$m^3$ contents of NY fibre for more than 80MPa high strength concrete, the effect of fibre contents on workability and strength development is not significant. 2) Based on the result of a 3-hour fire resistance test for mock-up column, it is necessary to secure 50 mm of covering depth for the regulation of fire resistance performance of high strength concrete to the standards of The Ministry of Land, Transport and Maritime Affairs. 3) It is necessary to secure more than 400mm of column size for stable fire resistance performance.