• Title/Summary/Keyword: 김현수

Search Result 2,738, Processing Time 0.038 seconds

Survey on Radiotherpv Protocols for the Rectal Cancers Among the Korean Radiation Oncologists in 2002 for the Development of the Patterns of Care Study of Radiation Therapy (방사선치료 Patterns of Care Study 개발을 위한 2002년 한국 방사선종양학과 전문의들의 직장암 방사선치료 원칙 조사연구)

  • Kim, Jong-Hoon;Kim, Dae-Yong;Kim, Young-Ho;Kim, Woo-Chul;Kim, Chul-Yong;Sung, Jin-Shil;Son, Seung-Chang;Shin, Hyun-Su;An, Young-Chan;Oh, Do-Hum;Oh, One-Yong;Yu, Mi-Ryung;Yu, Hung-Jun
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.44-65
    • /
    • 2003
  • Purpose : To conduct nationwide surgery on the principles In radiotherapy for rectal center, and develop the framework of a database of Korean Patterns of Care Study. Materials and Methods : A consensus committee was established to develop a tool for measuring the Patterns in radiotherapy Protocols for rectal cancer. The Panel was composed of radiation oncologists from 18 hospitals in Seoul Wetropolltan area. The committee developed a survey format to analyze radiation oncologist's treatment principles for rectal cancer. The survey items developed for measuring the treatment principles were composed of 1) 8 eliglblllty criteria, 2) 20 Items for staging work-ups and prognostic factors, 3) 7 Items for principles of combined surgery and chemotherapy, 4) 9 patient set-ups, 5) 19 determining radiation fields, 6) S radiotherapy treatment pians, 7) 4 physicalilaboratory examination to monitor a patient's condition during treatment, and 8) 10 follow-up evaluations. These items were sent to radiation oncoioglsts In charge of gastrolntestlnal malignancies in all hospitals (48 hospitals) In Korea to which 30 replies were received (63$\%$). Results : Most of the surrey Items were replied to without no major between the repliers, but with the fellowing items only 50$\%$ of repliers were in agreement : 1) Indications of preoperative radiation, 2) use of endorectal ultrasound, CT scan, and bone scan for staging work-ups, 3) principles of combining chemotherapy with radiotherapy, 4) use of contrast material for small bowel delineation during simulation, 5) determination of field margins, and 6) use of CEA and colonoscopy for follow-up evaluations. Conclusions : The Items where considerable disaggrement was shown among the radiation oncologists seemed to make no serious difference In the treatment outcome, but a practical and reasonable consensus should be reached by the committee, with logical processes of agreement. These Items can be used for a basic database for the Patterns of Care Study, which will survey the practical radiotherapy Patterns for rectal cancer in Korea.

Assessment of the Value and Distribution of Geological Heritages in Korea: Jeolla Province (한국의 지질유산 분포와 가치평가: 전라권)

  • Cho, Hyeongseong;Kang, Hee-Cheol;Kim, Jong-Sun;Cheong, Daekyo;Paik, In Sung;Lim, Hyoun Soo;Choi, Taejin;Kim, Hyun Joo;Roh, Yul;Cho, Kyu-Seong;Huh, Min;Shin, Seungwon
    • The Journal of the Petrological Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.319-345
    • /
    • 2019
  • Recently planification and effort for management, assessment and discovery of geological heritagesare being increasingly demanded with institutional strategies such as geopark, as their preservation is asked socially. In this study, we discovered geological heritages in the Jeolla Province and then performed assessment of the value and grading of them and finally suggested a promising and suitable site for the National Geopark. A total of 325 geological heritages are listed on literature review and then detailed description in field and assessment of the value for selected 158 geoheritages are completed. The assessment items are categorized into intrinsic value, subsidiary value, and preservation/management part. The intrinsic value is subdivided into scientific/educational value, composed of representativeness, rarity, geodiversity, typicality, reproducibility, and particularity, and geomorphological/landscape value composed of scale, naturality (integrity), scenery (aesthetic value). Also, subsidiary value consist of 7 subsections of soil function, ecological function, tourism value, geological resource, historical value, folk tale or legend and symbolic value, and accessibility, convenient facility (infrastructure), management condition (legal protection) is evaluated in preservation/management part. The heritages in the Jeolla Province subdivided into three types: 73 geological heritages, 42 geomorphological heritages, and 42 composite heritages. Based on points acquired in intrinsic value, all geological heritages are graded Class-I to -V. As a result, numbers of geoheritage belong to Class-I (protection at world level), -II (protection at national level), -III (nationdesignated management), -IV (involved management list), -V (candidate management list) are 12, 39, 52, 34, 21, respectively. Finally, we construct database based on Arc-GIS with all informations for each geological heritage and suggest three promising and suitable sites, 'Jirisan-Seomjingang Area' and 'south coast area of Jeolla Province', for the National Geopark.

The Clinical Study on Correlation between Knee Osteoarthritis and Obesity (퇴행성 슬관절염과 비만과의 상관성에 관한 임상 연구)

  • Kang, Jung-Won;Ryu, Seong-Ryong;Seo, Byung-Kwan;Cho, Mi-Ran;Cho, Ryo-Won;Woo, Hyun-Su;Lee, Sang-Hoon;Choi, Do-Young;Kim, Keon-Sik;Lee, Doo-Ik;Lee, Yun-Ho;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.22 no.6
    • /
    • pp.17-26
    • /
    • 2005
  • Objectives : The purpose of this study is to investigate the correlation between assessment measurements of knee osteoarthritis and obesity. Methods : Data on assessment measurements of knee osteoarthritis and obesity were obtained from 63 patients suffering from knee osteoarthritis from February to April, 2005. The assessment measurements consisted of BMI (body mass index), WHR (waist-hip ratio), two disease-specific questionnaires (Western Ontario and McMaster Universities (WOMAC) index and Lequesne's Functional Severity Index (LFI)), one generic instrument (Korean Health Assessment Questionnaire (KHAQ)), and VAS (Visual Analogue Scale). Statistical correlations among assessment measurements were evaluated by examining the Pearson's correlation coefficients. Results : 1. The sexual ratio in this study was 1: 5.3 (male: female= 10: 53). The average age of all patients was $59.1{\pm}6.6$ (male: $58.3{\pm}7.1$, female: $59.2{\pm}6.5$), and the group of 60-69 (34 patients, 54%) was biggest in the age distribution. 2. The average BMI of all patients was $25.4{\pm}3.1\;kg/m^2$ (male: female= $23.6{\pm}2.6\;kg/m^2:\;25.8{\pm}3.0\;kg/m^2$), and the group of $20-25\;kg/m^2$ was biggest in the BMI distribution. According to clinical definition of obesity by WHO (1997), 52.4% of all patients was within normal weight, 42.9% was overweight, and 4.8% was obese. 3. The average WHR of all patients was $0.91{\pm}0.06$ (male: female= $0.90{\pm}0.05:\;0.92{\pm}0.06$). According to definition of abdominal obesity, 73.0% of all patients (46 patients were all female) was in the state of abdominal obesity. 4. There were no significant correlations in statistics among assessment measurements except between BMI and WHR. Conclusion : Though there is significant correlation between knee osteoarthritis and obesity according to many clinical and experimental researches, there is no assessment measurement reflecting knee osteoarthritis and obesity simultaneously. For this, further studies on correlation between knee osteoarthritis and obesity and development of assessment measurement or questionnaire on this are needed.

  • PDF

Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer) (CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향)

  • Jang, Jaeuk;Han, Manseok;Kim, Minjeong;Kang, Hyeonsoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • This study is to evaluate the effect of a Contrast Media (CM) on dose calculations and clinical significance in Radiation (Electromagnetic wave) Therapy (RT) plans for head & neck (H&N) and prostate cancer. Pinnacle 8.0 system was used to measure the change of Electron Density (ED) of the tissue for CM. To determine the effect of dose calculation due to CM, we did the RT planning for 30 patients. To compare the ED and dose calculations of RT plans, 3D CRT and IMRT plans were do with pinnacle and Tomotherapy planning system. Mean difference of ED between enhanced and unenhanced CT was less than 4%: H&N Target Volume (TV) 2.1%, parotid 1.9%, SMG 3.6%, tongue 0.9%, spinal cord 0.3%, esophagus 2.6%, mandible 0.1% and prostate TV 0.7%, lymph node 1.1%, bladder 1.2%, rectum 1.5%, small bowel 1.2%, colon 0.6%, penile bulb 0.8%, femoral head -0.2%. The dose difference between RT plan using CM and without CM showed an increase of dose in TV. The rate of increase was less than 2.5% (3D CRT: H&N 0.69~2.51%, prostate 0.04~1.14%, IMRT: H&N 0.58~1.31%, prostate 0.36~1.04%). RT plans using a CM has the insignificant effect on the organs and TV, so this error is allowable clinically. However, the much more accurate plan is possible as to image fusion (CM and without CM images) to ROI contour and when dose calculation, use the without CM image. Using the fusion of 'ROI import' perform calculations on without CM, it will be able to reduce the error (1~3%) caused by the CM.

A Study on the Improvement for Medical Service Using Video Promotion Materials for PET/CT Scans (PET/CT 검사에서 동영상 홍보물을 통한 의료서비스 향상에 관한 연구)

  • Kim, Woo Hyun;Kim, Jung Seon;Ko, Hyun Soo;Sung, Ji Hye;Lee, Jeoung Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.30-35
    • /
    • 2013
  • Purpose: One of the current services, providing information to the patients and their guardians by using promotion materials induces positive responses and contributes to the improvement of the hospital reliability. Therefore, the objective of this study is to evaluate the effectiveness of audio visual materials, one of the means of promotion, as a way to give accurate medical information to resolve patient's curiosity about purpose and procedure of their examination and deplete complains about waiting which attributes negative effect to service quality assessment. Materials and Methods: 60 patients(mean age $53.97{\pm}12.24$, male : female = 26 : 34) who had $^{18}F-FDG PET/CT$ scan from July 2012 to August 2012 in Seoul Asan Medical Center were referred to the study. All of the patients having PET/CT scan were asked to watch an informative video material before the injection of radiopharmaceutical ($^{18}F-FDG$) and to fill in a questionnaire. Results: As a result of analyzing the contents of questionnaire, 52% of 60 patients had PET/CT scan for the first time and 72.4% of the patients read the PET/CT guidebook offered from their outpatient department or inpatient wards before their scan. After we searched the level of previous knowledge of the purpose and method of PET/CT scan, the patients answered 25.1% "know well", 34% "not sure", 40.9% "don't know" respectively. And 84.7% of the patients answered that watching the PET/CT guide video before the injection helps understanding what exam they were having and 15.3% of the patients did not. For the question asking ever the patients have experienced using our homepage or smart phone QR code to see the guide video before they visit out PET center, only 3.3% of them answered "yes". Lastly, the patients answered 60.1% "yes", 31.4% "so so" and 8.5% "no" respectively for the question asking whether watching the video makes the patients to fill the waiting time short. Conclusion: It is found that understanding of objective and method of the PET/CT scan and level of satisfaction was improved after the patients watched the guide video whether they had PET/CT scan before and read the PET/CT guidebook or not. Also, watching the video was effective for the reduction of perceptible waiting time. But while displaying the PET/CT guide video is useful for providing information about the scan and shortening the waiting time as one of the medical service, utilization of service was actually very poor because of the passive promotion and indifference of the patients about their examination. Therefore, from now on, it is necessary to construct the healthcare system which can be offered to more patients through the active promotion.

  • PDF

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Analysis of a Principal's Cognition on his Job Performance in Meister High Schools (마이스터고등학교 교장의 직무수행에 대한 교장의 인식분석)

  • Hyun, Su;Kim, Jinsoo
    • 대한공업교육학회지
    • /
    • v.38 no.2
    • /
    • pp.27-47
    • /
    • 2013
  • This study aims to suggest a way to improve the professional abilities of the principals of meister high schools by analysing their perception of the standards of performance of their duties. To carry out this study, we have developed the standards of performance of the duties of the principals of meister high schools through the systematic research on the realm of the duties of the principals of meister high schools, and analysed the principals' perception of their duties using the developed standards of performance of their duties. The results of this study are as followed. First, In the stage of planning the school management, the school management plan, the ways to get budget, the plan for evaluation and feedback of the accomplishment of the performance of school management plan should be included. Second, The area of the school management is subdivided into securing school budget, reviewing and arranging the budgets demanded by teachers, executing school budgets, obtaining school equipments and facilities, maintaining school equipments and facilities, managing school feeding, organizing and operating school steering committee, reflecting the opinions of school steering committee. Third, The school curriculum should be developed by a job analysis and the teaching should reflect the analysis. Fourth, The area of the career path and the management of the career for young meisters includes the analysis of the demand of students, parents, and companies, the development of meister growth route and program for managing their career, and the analysis of meister growth route and reflection of the results of the analysis. Fifth, The field of guiding students includes supporting the students counseling service, and managing a variety of school events. 6th, In the realm of cooperation with communities are included designing programs for collaborating and training students with companies, building cooperation with companies, and obtaining supports from communities and related organizations. 7th, In the area of supporting teachers to improve their professional competence, it figured out that supporting teachers' voluntary learning and studying should take a top priority. In conclusion, it is necessary for meister high school principals to have capability to deal with meister growth route and career management, supporting collaboration with other organizations, building and managing laboratories, encouraging teachers' professional improvement, and operating school curriculum and teaching activities.

The Growth Characteristics of Pleurotus eryngii (큰느타리버섯의 자실체 생육특성)

  • Ryu, Jae-San;Kim, Min-Keun;Kwon, Jin-Hyeuk;Cho, Sook-Hyun;Kim, Nak-Ku;Rho, Chi-Wong;Lee, Chun-Hee;Ro, Hyeon-Su;Lee, Hyun-Sook
    • The Korean Journal of Mycology
    • /
    • v.35 no.1
    • /
    • pp.47-53
    • /
    • 2007
  • In this study, we investigated the properties of incubation and growing of Pleurotus eryngii in addition to the mycological properties to use them as basic data for breeding. The speed of mycelial growth on the MCM was faster than on the PDA. The biomass in the PDB broth culture was higher than in the MCM and YMG broth culture. KNR2515 and KNR2516 required 19 days for growth of mycelia on commercial sawdust media. KNR2503 required 6.5 days and 15.3 days for pin-heading and harvesting, respectively. In morphological properties by the mushroom, the heights of KNR2312 and KNR2322 were 122.7 and 121.0 mm, respectively. The thickness of KNR2322 and KNR2513 were 39.8 mm and 31.3 mm, respectively. The weight of KNR2524's fruiting body was 36.3 g, which is good as wild strain. The quality of fruiting body of KNR2503 was 4.0 in comparison to the score 7 of commercially cultivated strains. KNR2512 had the darkest color of pileus with L value 43.6. The slow growing strains, KNR2511, KNR2513, and KNR2512 had the bright pileus with L value 80. In morphological characteristics, KNR2511, KNR2513, and KNR2515 had white lamellar and plane pileus. The three strains are supposed to be the same group and KNR2516 and KNR2518 appeared to be related to the group. The commercially cultivated strains had convex pileus, KNR2502, KNR2503, KNR2504, KNR2521, and KNR2525 had infundibuliform, and the other strains had plane pileus. Several strains were valuable for breeding, JNR2503 for growth rate, KNR2512 for pileus color, and KNR2312, KNR2322, KNR2503, and KNR2513 for the quality.

Effect of Moutan Cortex Radicis on gene expression profile of differentiated PC12 rat cells oxidative-stressed with hydrogen peroxide (모단피의 PC12 cell 산화억제 효과 및 neuronal 유전자 발현 profile 분석에 대한 연구)

  • Kim Hyun Hee;Rho Sam Woong;Na Youn Gin;Bae Hyun Su;Shin Min Kyu;Kim Chung Suk;Hong Moo Chang
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.529-541
    • /
    • 2003
  • Yukmijihwang-tang has been widely used as an and-aging herbal medicine for hundred years in Asian countries. Numerous studies show that Yukmijihwangtang has anti-oxidative effect both in vivo and in vitro. It has been reported that Moutan Cortex Radicis extract (MCR) was the most effective herb in Yukmijihwang-tang on undifferentiated PC12 cells upon oxidative-stressed with hydrogen peroxide. The purpose of this study is to; 1) evaluate the recovery of neuronal damage by assessing the anti-oxidant effect of MCR on PC12 cells differentiated with nerve growth factor (NGF), 2) identify candidate genes responsible for anti-oxidative effect on differentiated PC12 cells by oligonucleotide chip microarray. PC12 cells, which were differentiated by treating with NGF, were treated without or with hydrogen peroxide in the presence or absence of various concentration of MCR. Cell survival was determined by using MTS assay. Measurement of intracellular reactive oxygen species (ROS) generation was determined using the H2DCFDA assay The viability of cells treated with MCR was significantly recovered from stressed PC12 cell. In addition, wide rage of concentrations of MCR shows dose-dependent inhibitory effect on ROS production in oxidative-stressed cells. Total RNAs of cells without treatment(Control group), only treated with H₂O₂ (stressed group) and treated with both H₂O₂ and of MCR (MCR group) were isolated, and cDNAs was synthesized using oligoT7(dT) primer. The fragmented cRNAs, synthesized from cDNAs, were applied to Affymetrix GeneChip Rat Neurobiology U34 Array. mRNA of Calcium/calmodulin-dependent protein kinase II delta subunit(CaMKII), neuron glucose transporter (GLUT3) and myelin/oligodendrocyte glycoprotein(MOG) were downregulated in Stressed group comparing to Control group. P2X2-5 receptor (P2X2R-5), P2X2-4 receptor (P2X2R-4), c-fos, 25 kDa synaptosomal attachment protein(SNAP-25a) and GLUT3 were downregulated, whereas A2 adenosine receptor (A2AR), cathechol-O-methyltransferase(COMT), glucose transporter 1 (GLUT1), EST223333, heme oxygenase (HO), VGF, UI-R-CO-ja-a-07-0-Ul.s1 and macrophage migration inhibitory factor (MIF) were upregulated in MCA group comparing to Control group. Expression of Putative potassium channel subunit protein (ACK4), P2X2A-5, P2X2A-4, Interferon-gamma inducing factor isoform alpha precursor (IL-18α), EST199031, P2XR, P2X2 purinoceptor isoform e (P2X2R-e), Precursor interleukin 18 (IL-18) were downregulated, whereas MOO, EST223333, GLUT-1, MIF, Neuronatin alpha, UI-R-C0-ja-a-07-0-Ul.s1, A2. adenosine receptor, COMT, neuron-specific enolase (NSE), HO, VGF, A rat novel protein which is expressed with nerve injury (E12625) were upregulated in MCR group comparing to Stressed group. The results suggest that decreased viability and AOS production of PC12 cell by H₂O₂ may be, at lease, mediated by impaired glucose transporter expression. It is implicated that the MCR treatment protect PC12 cell from oxidative stress via following mechanisms; improving glucose transport into the cell, enhancing expression of anti-oxidative genes and protecting from dopamine cytotoxicity by increment of COMT and MIF expression. The list of differentially expressed genes may implicate further insight on the action and mechanism behind the anti-oxidative effects of herbal extract Moutan Cortex Radicis.