• Title/Summary/Keyword: 김주용

Search Result 498, Processing Time 0.028 seconds

A Comparative and Parametric Study of Slope Stability Using a Probability-based Method in Railway Slope (철도 사면에서 확률론적 기법을 이용한 사면안정성 매개변수 비교연구)

  • Choi, Chan-Yong;Kim, Ju-Yong;Eum, Ki-Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.4
    • /
    • pp.17-25
    • /
    • 2012
  • In this study, it was carried out reliability analysis and slope stability analysis in a standard cross-sectional embankment on high speed railway. It was confirmed that changing tendency of safety factor with various parameter of each soil materials properties and trends of the probability of failure according to the reliability index. The results have shown that a safety factor were relatively large affected an cohesions and internal friction angle of soil compared to the unit weight of soil. Also, most of the standard cross-sectional embankment in high speed railway was generally evaluated the level of below average (below average) by the reliability analysis according to criterion in US. Army but the 12m height of dry embankment case was shown bad condition as Poor.

Development of Smartphone Control Jacket Using Textile Touch Sensor (텍스타일 터치센서를 활용한 스마트폰 제어 기능 재킷 개발)

  • Park, Jinhee;Kim, Ji-seon;Kim, Jooyong
    • Journal of Fashion Business
    • /
    • v.24 no.5
    • /
    • pp.140-157
    • /
    • 2020
  • The purpose of this study is to develop three functions for smartphones and PCs using a textile touch sensor in an everyday sports jacket and to present their usefulness; to this end, we have developed a mutual capacitive textile touch sensor and corresponding structure, and we have implemented three functions into a textile touch sensor jacket, of which we also conducted a usability evaluation. The jacket has a sensor on the wrist of the left sleeve and a device on the left arm. The sensor system can be divided into three main categories: a sensor acting as a switch, a circuit connecting the sensor and the device, and the device that acts as power control and system on/off. The functions are implemented in the texture touch sensor jacket in three modes: cell phone mode, music mode, and PPT presentation mode. We conducted an evaluation of each function in each mode, which indicated that all functions performed well without errors and that the switch had excellent operation for the number and intensity of touch. In terms of usability in a humid environment, the performance of touch functions was found to be equally implemented. In the temperature environment, neither high nor low temperatures caused issues with the functions. A wearing satisfaction assessment evaluated psychological satisfaction, clothing convenience, device convenience, device usability, and device effectiveness. This research jacket is thought to be desirable for the relatively bendable, flexible, and intimate sensor used on the clothing, and the circuit made of conductive fabric tape.

The effect of foul on the performance during the field hockey game (필드하키 경기 중 파울이 경기력에 미치는 영향)

  • Park, Jong-Chul;Choi, Eun-Young;Kim, Ji-Eung;Lee, Seung-Hun;Kim, Ju-Yong
    • Journal of Digital Convergence
    • /
    • v.16 no.9
    • /
    • pp.489-495
    • /
    • 2018
  • The purpose of this study was to investigate the effect of fouls on performance in field hockey games. A total of 33 matches and 2101 fouls from 10 teams participated in the 2017 World League SEMI-FINAL tournament were analysed by region, race, type, and cause. The total data that is analysed by SportsCode and SPSS(correlation analysis & chi-square test)have showed that the top ranked countries had a higher foul frequency than the lower ranked nations. According to the situation that has showed the result of the analysis, it showed that there was no difference between the results analysed on the foul type and the attacking and defence situation but it has indicated that area, game situation and the cause of fouls showed there was a significant difference. On these results, it is hoped to use fouls as one of the tactical means in women's field hockey games.

Development of a Semi-automatic Cloth Inspection Machine for High-quality Fabric Patterns (고감성 패턴 제조를 위한 반자동 검단기의 개발)

  • Kim, Joo-Yong;Kim, Ki-Tai
    • Science of Emotion and Sensibility
    • /
    • v.11 no.2
    • /
    • pp.207-214
    • /
    • 2008
  • The inspection processing is for reducing loss which occurs fault because of fabric appearance. Up to now inspection machine which is used from inspection process is classified with the macrography inspection machine and the full automatic inspection machine. The macrography inspection machine is low price and efficient equipment but does not record information of fault. On the other side, the automatic inspection machine is high price, also the detection rate of one changes with effect of environment variable but able to record information of fault. It developed semi-automatic cloth inspection machine with the weak point of the macrography inspection machine and the automatic inspection machine was complemented. And when it uses information which was collected by semi-automatic cloth inspection machine, the loss rate of original fabric is able to calculate. So sewing factories will be able to predict fabric consuming quantity.

  • PDF

Intraosseous Epidermal Cyst of the Distal Phalanx: A Case Report (원위 지골에서 발생한 골내 표피낭종: 증례 보고)

  • Kong, Gyu-Min;Kim, Joo Yong;Kim, Jung-Han;Park, Dae-Hyun;An, Kwang Hun
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.20 no.1
    • /
    • pp.22-26
    • /
    • 2014
  • An intraosseous epidermal cyst is a rare benign cystic lesion. It is thought to result from congenital factors or trauma and can lead to bone destruction because the cyst develops at the soft tissue around the bone. Radiological findings of intraosseous epidermal cysts are a well-defined radiolucent lesion, with cortical expansion. It is important to differentiate an intraosseous epidermal cyst with other disease developed at distal phalanx because its clinical and radiological findings are similar. We report two rare cases of intraosseous epidermal cysts that developed at the distal phalanx.

Surface Modification Effect and Mechanical Property of para-aramid Fiber by Low-temperature Plasma Treatment (저온 플라즈마 처리를 이용한 파라 아라미드 섬유의 표면 개질 효과 및 역학적 특성(2))

  • Park, Sung-Min;Son, Hyun-Sik;Sim, Ji-Hyun;Kim, Joo-Young;Kim, Taekyeong;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.27 no.1
    • /
    • pp.18-26
    • /
    • 2015
  • para-aramid fibers were treated by atmosphere air plasma to improve the interfacial adhesion. The wettability of plasma-treated aramid fiber was observed by means of dynamic contact angle surface free energy measurement. Surface roughness were investigated with the help of scanning electron microscopy and atomic force microscopy. The tensile test of aramid fiber roving was carried out to determine the effect of plasma surface treatments on the mechanical properties of the fibers. A pull-out force test was carried out to observe the interfacial adhesion effect with matrix material. It was found that surface modification and a chemical component ratio of the aramid fibers improved wettability and adhesion characterization. After oxygen plasma, it was indicated that modified the surface roughness of aramid fiber increased mechanical interlocking between the fiber surface and vinylester resin. Consequently the oxygen plasma treatment is able to improve fiber-matrix adhesion through excited functional group and etching effect on fiber surface.

Demonstration of Voltage Control of DC Distribution System Using Real-time DC Network Analysis Applications (실시간 DC 계통해석 응용프로그램을 이용한 DC 배전망 전압제어 실증 연구)

  • Kim, Hong-joo;Cho, Young-pyo;Cho, Jin-tae;Kim, Ju-yong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.275-286
    • /
    • 2019
  • This paper presents real-time Direct Current (DC) network analysis applications for operation of DC distribution system or DC microgrid. These applications are installed on central Energy Management System (EMS) and provide solutions of DC network operation. To analysis DC distribution network, this paper proposes composition and sequence of applications. Algorithm of applications is presented in this paper. Demonstration tests are performed on DC distribution site in Gochang Power Testing Center of Korea Electric Power Corporation (KEPCO). To verify the performance, developed DC applications installed on EMS. Scenarios for demonstration test of voltage control are presented. Finally, measured data, application output data and simulation data (by PSCAD/EMTDC) are compared and analyze accuracy of applications.

Study on Local Buckling of District Heating Pipes Using Limit State Design (한계상태 설계법을 이용한 지역난방 열배관의 국부좌굴 연구)

  • Kim, Joo-Yong;Lee, Sang-Youn;Ko, Hyun-Il;Cho, Chong-Du
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1829-1836
    • /
    • 2010
  • The district heating system distributes the heat generated from a cogeneration plant to wider locations. In this process, the district heating pipe (DHP) is subjected to internal and external loadings. The internal loadings are generally caused by the operating conditions such as water temperature and internal pressure. Frictional interactions between the pipes and the soil contribute to the external loadings. Thus, investigation of the mechanisms of failure of DHPs will help to guarantee both mechanical stability and heating efficiency. In this study, we investigate the local buckling of DHPs using limit state design (LSD). Two methods are considered: the use of the limit state for the width-thickness ratio and the use of the limit state for the strain. The results are used to confirm that the DHP is stable under local buckling. Finally, we suggest a minimum preheating temperature for avoiding local buckling.

A Design of the efficient data aggregation using Hotspot Zone on Ad-hoc Networks (Ad-hoc 네트워크상에 Hotspot Zone을 이용한 효율적인 데이터 집계 설계)

  • Kim, Ju-Yung;Ahn, Heui-Hak;Lee, Byung-Kwan
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.7
    • /
    • pp.17-24
    • /
    • 2012
  • As the resources and power on Ad-hoc networks are limited, new data aggregation techniques are required for energy efficiency. The current research on data aggregation techniques is actively in progress, but existing studies don't consider the density of nodes. If nodes are densely placed in a particular area, the information which the sensor nodes placed on those areas detect can be judged as very strong association. But, the energy spent transmitting this information is a waste of energy. In this paper the densely-concentrated node area is designated as Hotspot_Zone in the multi-hop clustering environment using the AMC and a key node is selected in the area. If the request message of data aggregation is transmitted, the key node among the neighboring nodes sends its environmental information to a manager to avoid duplicate sensing information. Therefore, the life of networks can be prolonged due to this.

The Experimental Consideration of ZVT-PWM AC-DC Converter using Active Auxiliary Resonant Snubber (액티브 보조 공진 스너버를 이용한 ZVT-PWM AC-DC 컨버터의 실험적 고찰)

  • 서기영;문상필;김주용;박진민
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.75-82
    • /
    • 2004
  • Zero Voltage Transition Pulse Width Modulation (ZVT-PWM) converter with active snubber circuit was proposed on this paper. The converter that has been proposed snubber circuit can be operated at the condition of light load range, and this converter is turned on and off near by Zero Voltage Switching (ZVS) or Zero Current Switching (ZCS). If the stress of voltage and current are not occurred at the main switch and main diode, we subjected the allowed level of voltage and current on the auxiliary switch and auxiliary diodes. By proposed 750[W], 80[KHz] PWM boost converter to apply soft switching on the power of total output, the loss of main switch to compare with hard switching was reduced about 27[%], and the loss of total circuit was reduced about 36[%]. The total efficiency was increased about 6[%] to compare with general converter.