• Title/Summary/Keyword: 기존 받침

Search Result 53, Processing Time 0.028 seconds

The Pseudo-Dynamic Test for the Seismic Retrofit System Utilizing Existing Bridge Bearings (교량의 기존 받침을 활용하는 내진보강시스템의 유사동적 실험)

  • Kwahk, Im-Jong;Cho, Chang-Beck;Kim, Young-Jin;Kwark, Jong-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.1 s.53
    • /
    • pp.21-27
    • /
    • 2007
  • In this study, an approach that installs seismic isolation bearings was proposed for the seismic retrofit of the existing bridges. The method that replaces all existing bearings with seismic isolators was proposed already. However, in this study, we recommend to utilize the existing bearings for the benefit of safety and cost. According to our proposal, the seismic isolators do not support vertical loads but they Just function as the period shifter and the horizontal damper. To verify this approach experimentally, the real scale bearings and lead rubber bearings far the real highway bridges were designed and fabricated. And the responses of this isolated bridges to the assumed earthquakes were determined by the pseudo dynamic test scheme. The test results were also compared to the responses computed by the well known structural analysis software to check the reliability of the test. From the test results, we found that the retrofitted bridges using the proposed method showed stable performances under earthquakes.

Mechanical Characteristic Analysis of Fiber Reinforced Strip Form Elastomeric Bearing by Experiment (스트립형 섬유 보강 탄성받침의 실험에 의한 기계적 특성해석)

  • 강경주;문병영;강범수;김계수;박진삼
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.6
    • /
    • pp.1-6
    • /
    • 2002
  • In order to apply seismic isolators to low-cost buildings, seismic isolators have to be low-cost and light. In this paper fiber reinforced strip form isolator in which the steel plates of conventional rubber bearing were replaced by fiber was proposed. The proposed fiber reinforced strip form isolator was designed, fabricated, cut and subjected to vertical test and horizontal test. Therefore, fiber reinforced strip form isolator was to be shown valid in the view point of fabrication and application to desired size. The horizontal test and vertical test have shown that fiber reinforce strip form isolator could be replaced the rubber isolator. By these results, low-cost and light seismic isolator can be applied to the low-cost building.

Maintenance and Dynamic Behavior of Advanced Spherical Bearings under Railway Open-Steel-Plate-Girder Bridges (판형교에서 개량된 스페리칼받침의 유지보수 및 동적 거동)

  • Choi, Eun-Soo;Lee, Hee-Up;Lee, Seung-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.2
    • /
    • pp.165-175
    • /
    • 2008
  • Line type rigid bearings for Open-Steel-Plate-Girder railway bridges have several problems in service, and they are unstable structurally. A series of lateral resistance tests were performed for a retrieved line type bearing. A spherical bearing with advanced maintenance-capability and a device to resist the up-lift was developed and replaced the existing ones. An experiment of maintenance for a new spherical bearing under real Open-Steel-Plate-Girder bridge was conducted and their good maintenance performance was proved. Also, a test against up-lift was performed for the bearing. The dynamic behavior of the bridge was measured and analyzed for the two cases of the existing and replaced bearings. Therefore, the suitability of the new spherical bearings on the railway bridge was improved.

Comparative Seismic Design of Bridges with Lead Rubber and Steel Bearings for the Ductile Failure Mechanism (지진격리교량과 강재받침교량의 연성파괴메커니즘에 의한 비교내진설계)

  • Kook, Seung Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.173-181
    • /
    • 2006
  • Many isolated bridges are designed and constructed after the introduction of the seismic design. However those bridges designed in engineering fields have unnecessarily high serviceability limit and brittle failure mechanism, which do not satisfy the seismic design concept. Such design results are due to the excessive substructure stiffness of the conventional design method as well as the misunderstanding of the seismic design method. In this study an isolated bridge designed with the conventional design method is selected and the same bridge with steel bearings is modelled for the comparative seismic design. From the comparison, the seismic design procedures satisfying the required performance levels are provided for the two bridges. It is confirmed that the isolated bridge requires more complicated design procedure with trial and error methods and reanalyses but provides higher serviceability limit compared to the bridge with steel bearings. However, because the required serviceability limit can also be obtained by adjusting substructure stiffness, it is a resonable seismic design process that an isolated bridge is to be considered as an alternative design when the ductile failure mechanism is not obtained with a bridge with steel bearings.

Seismic Behavior and Estimation for Base Isolator Bearings with Self-centering and Reinforcing Systems (자동복원 및 보강 시스템과 결합된 면진받침의 지진거동과 평가)

  • Hu, Jong Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1025-1037
    • /
    • 2015
  • Flexible base isolation bearings that separate superstructure from ground have been widely used in the construction field because they make a significant contribution to increasing the fundamental period of the structure, thereby decreasing response acceleration transmitted into the superstructure. However, the established bearing devices installed to uphold the whole building give rise to some problems involved with failure and collapse due to lack of the capacity as modern structures are getting more massive and higher. Therefore, this study suggests new isolation bearings assembled with additional restrainers enabled to reinforcing and recentering, and then evaluates their performance to withstand the seismic load. The superelastic shape memory alloy (SMA) bars are installed into the conventional lead-rubber bearing (LRB) devices in order to provide recentering forces. These new systems are modeled as component spring models for the purpose of conducting nonlinear dynamic analyses with near fault ground motion data. The LRB devices with steel bars are also designed and analyzed to compare their responses with those of new systems. After numerical analyses, ultimate strength, maximum displacement, permanent deformation, and recentering ratio are compared to each model with an aim to investigate which base isolation models are superior. It can be shown that LRB models with superelastic SMA bars are superior to other models compared to each other in terms of seismic resistance and recentering effect.

The Effects of Elastomer-Bearing on the Dynamic Behaviors of Bridge for KHSR (고속철도 교량의 동적거동에 미치는 탄성받침의 영향)

  • 곽종원;김병석
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.3
    • /
    • pp.1-8
    • /
    • 1999
  • The bridges for Korea High-Speed Railway(KHSR) under construction are supported with pot bearings on the middle pier and with pad bearings on the side piers, respectively. The dynamic analysis on these bridges due to trains with high speed, however, has been performed neglecting the effects of bearings. The objective of this study is investigation on the dynamic behavior of bridge supported by pad bearings. The effects of pad bearings with various flexibilities on the dynamic responses of bridges are studied. From the results of this study, the effects of elastomeric bearing on the dynamic responses of bridge(especially vertical accelerations) may cause undesirable behaviors.

  • PDF

A Study on the Seismic Analysis of Bridge with Lead Rubber Bearing (LRB(Lead Rubber Bearing)가 설치된 교량의 지진해석 연구)

  • Huh, Young;Park, Jin-Hyung
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.374-381
    • /
    • 2000
  • 본 논문에서는 지진 발생시, LRB가 설치된 교량의 시간이력 해석을 수행하였다 이를 위해 LRB의 비선형 거동특성을 Bi-linear로 모형화 하였으며, 기존의 방법인 등가선형으로 모형화된 해석결과와 비교하였다. 또한 LRB받침만 설치된 경우와, LRB받침과 일반탄성받침이 함께 사용된 경우를 해석하여, 받침이 혼합된 경우, 상시하중과 지진하중시 발생할 수 있는 문제점을 검토하였다. 4경간 연속교량에 적용된 해석결과를 보면, LRB만을 설치한 경우, Pot-Bearing만 설치된 경우에 .비해, 고유주기 상승과 이력감쇠에 의한 지진력의 감소와 함께, 지진력의 효과적인 분배를 볼 수 있었으며, 일반탄성받침과의 적절한 조합에 의해서도, 충분한 면진성능을 얻을 수 있었다. 또한 LRB의 등가선형 모델이 Bi-linear 모델에 비해 보수적인 해석결과를 나타내었다.

  • PDF

Variation of Seismic Behavior of Continuous Skew Plate Girder Bridges According to the Arrangement of Bearings (받침배치에 따른 연속 플레이트 거더 사교의 지진거동 변화)

  • Moon, Seong Kwon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.124-135
    • /
    • 2011
  • The capacity of bearings installed at abutments and piers for continuous bridges is usually determined by the magnitude of the maximum vertical reaction at each support and the capacity of bearings placed at piers is higher than that at abutments. In this study, the possibility of the improved seismic performance of base-isolated continuous skew bridges was investigated by analysing the variation of the seismic behavior of them according to three arrangements of bearings. Based on the conventional arrangement of bearings(Case A), three arrangements of bearings such as Case A, Case B and Case C were selected considering the variation of the horizontal stiffness of the lead rubber bearing(LRB) installed at the pier. The seismic behavior of the total 36 skew bridges was investigated by conducting the response spectrum analysis using the hybrid response spectrum considered the effect of LRB's damping. Results of analyses show that a more desirable seismic behavior of base-isolated continuous skew bridges can be obtained by reducing the magnitude of the horizontal stiffness of LRB placed at the pier to similar to or less than that of LRB installed at abutments. The variation of LRB's stiffness at the pier brings about period elongation and the change of mode shapes of base-isolated skew bridges and results in the reduction of the total base shear, the maximum base shear at the pier and the girder stresses. Although positive effects on the seismic behavior of base-isolated skew bridges caused by the change of arrangement of bearings decreased slighty with an increase in the flexibility of the substructure, the proposed arrangements of bearings bring about the improved seismic performance of base-isolated continuous skew plate girder bridges with less than 10m height of piers.

Evaluation on Structural Safety for Bearing seat according to Replacement of Bridge Bearing (교량받침 교체에 따른 보자리 구조 안전성 평가)

  • Choi, Jung-Youl;Lee, Hee-Kwang;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.753-760
    • /
    • 2020
  • In this study, the structural safety of the bearing support was analysed by applying the vertical load (bearing design load) and horizontal load (horizontal force generated during an earthquake) using a precise three-dimensional numerical model. The results of stress and displacement of newly-poured concrete and welded rebars were confirmed numerically. Numerical results show that the increase in the horizontal force and the height of the beam causes the concrete cracking and the stress increase of the rebar connections due to the increase of the stress at the new concrete interface. Therefore, it was analyzed that the increase in the height of bearing support is directly related to the horizontal force and it is necessary to apply the bearing support height appropriate for the bearing support capacity. It was proposed that a method of setting the height of the bearing support suitable for the bearing capacity and determining the reinforcement by presenting the guideline with the correlation between the horizontal force acting on the bearing support and its height.

A Study on Isolation Performance of High Damping Rubber Bearing Through Shaking Table Test and Analysis (진동대 실험 및 해석을 통한 고감쇠 고무받침의 면진성능 연구)

  • Kim, Hu-Seung;Oh, Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.601-611
    • /
    • 2016
  • The research, development and use of seismic isolation systems have been increasing with the gradual development of structure safety assurance methods for earthquakes. The High Damping Rubber Bearing (HDRB), one type of seismic isolation system, is a Laminated Rubber Bearing using special High Damping Rubber. However, as its damping function is slightly lower than that of the Lead Rubber Bearing, a similar seismic isolation system, its utilization has not been high. However, the HDRB has a superior damping force to the Natural Rubber Bearing, which has similar materials and shapes, and the existing Lead Rubber Bearing has a maleficence problem in that it contains lead. Thus, studies on HDRBs that do not use lead have increased. In this study, a test targeting the HDRB was done to examine its various dependence properties, such as its compressive stress, frequency and repeated loading. To evaluate the HDRB's seismic performance in response to several earthquake waves, the shaking table test was performed and the results analyzed. The test used the downscaled bridge model and the HDRB was divided into seismic and non-seismic isolation. Consequently, when the HDRB was applied, the damping effect was higher in the non-seismic case. However, its responses on weak foundations, such as in Mexico City, represented increased shapes. Thus, its seismic isolator.