• Title/Summary/Keyword: 기저

Search Result 2,998, Processing Time 0.037 seconds

A 0.18-μm CMOS Baseband Circuits for the IEEE 802.15.4g MR-OFDM SUN Standard (IEEE 802.15.4g MR-OFDM SUN 표준을 지원하는 0.18-μm CMOS 기저대역 회로 설계에 관한 연구)

  • Bae, Jun-Woo;Kim, Chang-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.3
    • /
    • pp.685-690
    • /
    • 2013
  • This paper has proposed a multi-channel and wide gain-range baseband circuit blocks for the IEEE 802.15.4g MR-OFDM SUN systems. The proposed baseband circuit blocks consist of two negative-feedback VGAs, an active-RC 5th-order chebyshev low-pass-filter, and a DC-offset cancellation circuit. The proposed baseband circuit blocks provide 1 dB cut-off frequencies of 100 kHz, 200 kHz, 400 kHz, and 600 kHz respectively, and achieve a wide gain-range of +7 dB~+84 dB with 1 dB step. In addition, a DC-offset cancellation circuit has been adopted to mitigate DC-offset problems in direct-conversion receiver. Simulation results show a maximum input differential voltage of $1.5V_{pp}$ and noise figure of 42 dB and 37.6 dB at 5 kHz and 500 kHz, respectively. The proposed I-and Q-path baseband circuits have been implemented in $0.18-{\mu}m$ CMOS technology and consume 17 mW from a 1.8 V supply voltage.

Effect of Coating Technique on the Characteristics of ZnS(Ag) Scintillation Composite for Alpha-ray Detection (알파선 측정용 ZnS(Ag) 섬광 복합체의 특성에 있어 도포방법이 미치는 영향)

  • Jung, Yeon-Hee;Park, So-Jin;Seo, Bum-Kyoung;Lee, Kune Woo;Han, Myeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.17 no.6
    • /
    • pp.604-608
    • /
    • 2006
  • Polymer composites for measuring the radioactive contamination are prepared by coating ZnS(Ag) powders as a scintillator on polysulfone base layer. The composites consist of the active layer for a scintillation reaction with radioactive wastes and the transparent support layer for transmittance of light photons emitted by scintillation in the active layer. The binding of the active layer, including ZnS(Ag), on the support layer is proceeded via coating with polysulfone as a binder, without any extra adhesive. The coating was obtained by either casting via a Doctor Blade as applicator or screen printing. The prepared composites feature a monolithic structure, resulting in the complete adhesion between two layers. The composite prepared by the casting technique using an applicator holds a good detection efficiency in measuring the alpha radionuclide, but its structure becomes fragile because of warping in morphology. On the contrary, the composite prepared by the screen printing shows a good detection capacity as well as a good stability in a mechanical shape.

Prolactin Response to Cimetidine in the Schizophrenics - In Unmedicated Male Positive and Negative Patients - (정신분열증 환자에서 Cimetidine에 의한 Prolactin 분비 반응 - 양성 및 음성 아형 남자 환자에서 -)

  • Jin, Hyuk Hee;Kwon, Young Joon;Jeong, Hee Yeon;Han, Sun Ho
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.1
    • /
    • pp.121-126
    • /
    • 1996
  • Objects : There is considerable interest in the role of serotonin(5-HT) in the pathophysiology of schizophrenia. Cimetidine, $H_2$ antagonist, produces transient increase in serum prolactin(PRL) levels by indirect serotonergic mechanism in man following intravenous administration. Therefore the authors investigated the effects of cimetidine on serum PRL levels of male unmedicated schizophrenics. Method : Baseline serum prolactin level and psychopathology were measured at 9:00 AM. in the two groups(12 positive schizophrenics, 7 negative schizophrenics) and $T_{30}$ levels were measured 30 minutes after intravenous injection of cimetidine (ie, 9:30 AM) Results: 1) Baseline prolactin levels were not different in the three groups. 2) Prolactin levels of 30 minutes after intravenous injection of cimetidine($T_{30}$) compared with baseline prolactin levels were increased all in the three groups. 3) Degrees of interval change from baseline to $T_{30}$ were significantly different between normal control and negative schizophrenics(p<0.05). Conclusion : The prolactin response to cimetidine was significantly blunted in negative male schizophrenics than normal control. These data are consistent with the hypothesis of an abnormality of serotonergic activity, including down-regulation $5-HT_2$ receptors, in male negative schizophrenics.

  • PDF

Automatic Skin Basal Cell Carcinoma Detection Using Protophorphyrin IX((PpIX) Fluorescence Image (PpIX 형광영상을 이용한 피부 기저세포암 자동검출)

  • Yu, Hong-Yeon;Jun, Do-Young;Kim, Min-Sung;Hong, Sung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.1
    • /
    • pp.47-54
    • /
    • 2008
  • In this paper, we propose an auto-detection algorithm of basal cell carcinoma(BCC) from the protophorphyrin IX(PpIX) fluorescence image induced by appling the methyl 5-aminolaevulinate(MAL) ointment-induced protophorphyrin IX(PpIX) to the skin tumour area and then shining the wood lamp on the area. The proposed algorithm first generates 3 mask areas-tumor area, suspected tumor area and tumor free area and then applies local watershed algorithm to the turner and the suspected tumor areas to make small watershed regions that include similar luminance value pixels. Next, small watershed regions are merged by hierarchical queue based fast region merging that uses the difference between the average luminance values of adjacent watershed regions as a region merging criterion and finally BCC regions are detected. 50 tissue samples are acquired from the tumour regions of 10 patients with BCC that are extracted by using the proposed algorithm and are performed pathological examination by expert dermatologist. Experiment result shows the rate of tumor detection from BCC lesion using presurgical in vivo of MAL-indeuced PpIX fluorescence has high sensitivity 94.1% and relatively high specificity 82.6%.

Baseline Wander Removing Method Based on Morphological Filter for Efficient QRS Detection (효율적인 QRS 검출을 위한 형태 연산 기반의 기저선 잡음 제거 기법)

  • Cho, Ik-Sung;Kim, Joo-Man;Kim, Seon-Jong;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.166-174
    • /
    • 2013
  • QRS detection of ECG is the most popular and easy way to detect cardiac-disease. But it is difficult to analyze the ECG signal because of various noise types. The important problem in recording ECG signal is a baseline wandering, which is occurred by rhythm of respiration and muscle contraction attaching to an electrode. Particularly, in the healthcare system that must continuously monitor people's situation, it is necessary to process ECG signal in realtime. In other words, the design of algorithm that exactly detects QRS region using minimal computation by analyzing the person's physical condition and/or environment is needed. Therefore, baseline wander removing method based on morphological filter for efficient QRS detection method is presented in this paper. For this purpose, we detected QRS through the preprocessing method using morphological filter, adaptive threshold, and window. The signal distortion ratio of the proposed method is compared with other filtering method. Also, R wave detection is evaluated by using MIT-BIH arrhythmia database. Experiment result show that proposed method removes baseline wanders effectively without significant morphological distortion.

Classical testing based on B-splines in functional linear models (함수형 선형모형에서의 B-스플라인에 기초한 검정)

  • Sohn, Jihoon;Lee, Eun Ryung
    • The Korean Journal of Applied Statistics
    • /
    • v.32 no.4
    • /
    • pp.607-618
    • /
    • 2019
  • A new and interesting task in statistics is to effectively analyze functional data that frequently comes from advances in modern science and technology in areas such as meteorology and biomedical sciences. Functional linear regression with scalar response is a popular functional data analysis technique and it is often a common problem to determine a functional association if a functional predictor variable affects the scalar response in the models. Recently, Kong et al. (Journal of Nonparametric Statistics, 28, 813-838, 2016) established classical testing methods for this based on functional principal component analysis (of the functional predictor), that is, the resulting eigenfunctions (as a basis). However, the eigenbasis functions are not generally suitable for regression purpose because they are only concerned with the variability of the functional predictor, not the functional association of interest in testing problems. Additionally, eigenfunctions are to be estimated from data so that estimation errors might be involved in the performance of testing procedures. To circumvent these issues, we propose a testing method based on fixed basis such as B-splines and show that it works well via simulations. It is also illustrated via simulated and real data examples that the proposed testing method provides more effective and intuitive results due to the localization properties of B-splines.

Evaluation of Bio-cha's ability to secure underground penetration water and its effect on water quality improvement (바이오차의 지하 침투수 확보 능력 및 수질개선 효과 평가)

  • Tae Seong Kang;Jeong Ha Lim;Dong Hyuk Kum;Min Hwan Shin;Jong Gun Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.468-468
    • /
    • 2023
  • 최근 급격한 기후변화에 의한 이상가뭄 발생 등을 대비하기 위한 비상용수 또는 대체 수자원으로서의 지하수 개발수요가 증가함에 따라 기저유량 확보 및 수질개선 방안을 수립하는 것은 지속가능한 수자원 이용 관리 측면에 있어서 매우 중요하다. 국내 지하수 사용에 따른 하천유량의 변동에 관한 연구는 활발히 진행되었으나, 실질적으로 적용가능한 지하수 저감 방안 및 지하 수질개선방안에 대한 연구는 미비한 실정이다. 이에 본 연구에서는 바이오차를 이용하여 시험포를 설계 및 시공하였으며, 실내 인공강우 실험을 통해 지하 침투수 확보 능력 및 수질개선 효과를 평가하였다. 대조구는 폭 1 m × 길이 1 m × 깊이 0.60 m로 시공하였으며, 바이오차 시험포는 폭 1 m × 길이 1 m, 시험포 상단과 하단 각 0.10 m씩 대조구와 동일한 흙으로 채웠으며, 그 사이 0.40 m만큼은 바이오차를 채워서 시공하였다. 시험의 정밀도를 높이기 위해 동일한 조건으로 대조구와 바이오차 시험포 각 2개씩, 총 4개의 시험포를 시공하여 실내 인공강우 실험을 진행하였으며, 시험포에서 발생한 직접유출수와 기저유출수를 이용하여 바이오차의 지하 침투량 확보 및 수질개선효과를 분석하였다. 시험포 완공 후 총 2번의 실내인공강우 실험 결과 대조구에서 발생한 직접유출량은 총 0.214 m3, 바이오차 시험포에서는 총 0.194 m3로 대조구 대비 총 직접유출량 저감효과는 9.4%로 나타났다. 기저유출의 경우 바이오차 시험포(0.036 m3)에서 대조구(0.003 m3) 대비 약13배 많은 양의 기저유출수가 발생한 것으로 나타났다. 각 시험포에서 발생한 유출수의 오염부하를 산정해 대조구 시험포 대비 바이오차 시험포에서 발생한 직접유출수의 오염부하 저감효과를 분석한 결과 BOD5 항목과 CODMn 항목, 그리고 TOC 항목의 경우 26.3%과 22.0%, 그리고 27.6%로 저감 된 것으로 나타났으나, SS 항목과 T-N 항목, 그리고 T-P 항목의 경우 저감효과가 없는 것으로 나타났다. 이와 같이 바이오차는 지하 침투수 확보 능력은 효과적인 것으로 나타났으나, 직접유출수의 수질개선 효과는 미비한 것으로 나타났다. 그러나 바이오차의 지하 침투량 및 수질개선 효과는 바이오차 생산 시 사용된 열분해 방식, 사용된 바이오차의 양 등에 따라 편차가 클것으로 판단되며, 바이오차의 생산 방법, 토양 흡착 기간, 바이오차의 양 등 다양한 조건에서의 모니터링을 통해 정량화 되어야 할 것으로 판단된다.

  • PDF

Understanding the Asymptotic Convergence of Domain of Attraction in Extreme Value Distribution for Establishing Baseline Distribution in Statistical Damage Assessment of a Structure (통계적 구조물 손상진단에서 기저분포 구성을 위한 극치분포의 점근적 수렴성 이해)

  • Kang, Joo-Sung;Park, Hyun-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.231-242
    • /
    • 2009
  • The baseline distribution of a structure represents the statistical distribution of dynamic response feature from the healthy state of the structure. Generally, damage-sensitive dynamic response feature of a structure manifest themselves near the tail of a baseline statistical distribution. In this regard, some researchers have paid attention to extreme value distribution for modeling the tail of a baseline distribution. However, few researches have been conducted to theoretically understand the extreme value distribution from a perspective of statistical damage assessment. This study investigates the asymptotic convergence of domain of attraction in extreme value distribution through parameter estimation, which is needed for reliable statistical damage assessment. In particular, the asymptotic convergence of a domain of attraction is quantified with respect to the sample size out of which each extreme value is extracted. The effect of the sample size on false positive alarms in statistical damage assessment is quantitatively investigated as well. The validity of the proposed method is demonstrated through numerically simulated acceleration data on a two span continuous truss bridge.

Immunohistochemical and Immunocytochemical Study about the Glial Fibrillary Acidic Protein in the Tanycytes of the Area Postrema of Bat (박쥐 맨아래구역 띠뇌실막세포의 Glial Fibrillary Acidic Protein에 대한 면역조직화학 및 면역세포화학적 연구)

  • Yang, Young-Chul;Cho, Byung-Pil;Kang, Ho-Suck
    • Applied Microscopy
    • /
    • v.30 no.4
    • /
    • pp.377-387
    • /
    • 2000
  • There are a few tanycytes between the general ependymal cells lining the ependymal layer of the brain ventricle. These cells are considered as modified ependymal cells which possess a long basal process. Tanycytes are known to have an ability to communicate by absorbing substances from cerebrospinal fluid and transporting them to the blood vessels and/or to the neurons in the CNS. The third and fourth ventricular tanycytes were mainly studied as subjects but it's rare to find reports about the tanycytes of the area postrema. Glial fibrillary acidic protein is an intermediate filament protein that is expressed especially in astrocytes of the CNS. But GFAP is also found in filament of the tanycytes and its process. Therefore this study was carried out for the examination of the GFAP immunoreactive tanycytes lining the area postrema of the bat, and we also examined the ultrastructure of tanycytes using electron microscope. GFAP immunoreactive tanycytes were located in the caudal portion of the fourth ventricle, and especially mainly in the transitional zone between the floor of the caudal fourth ventricle and ependymal layer lining the area postrema. A few GFAP immunoreactive tanycytes were also found in the ependymal layer lining the area postrema, and some groups of tanycytes were found in the ependymal layer of the area postrema near the floor of the caudal fourth ventricle , The processes of tanycytes were stained deeply with anti-GFAP antibody. Especially the GFAP immunoreactive tanycytes lining the area postrema had very long processes that cross the whole width of the area postrema. In the electron microscope, the cell body of ependymal tanycyte was located on the ependymal layer and had a long basal process. Intermediate filaments were observed around the nucleus and well developed in the process of tanycrte. Longitudinal oriented long mitochondria and a few lipid droplets were also found in this process. After immunocytocheical staining, the gold particles were found only in the intermediate filaments. We could not determine the function of the tanycytes in the area postrema. Thus, further investigation is required to determine the functional relationship between the tanycytes and the area postrema in hibernating animal, the bat.

  • PDF

Clinical and Pathologic Analysis of Thin Glomerular Basement Membrane Disease in Children (소아 비박형 기저막신증의 임상 및 병리학적 분석)

  • Ko Myoung Jin;Yang Tae Jin;Kim Young Ju;Chung Woo Yeong
    • Childhood Kidney Diseases
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Purpose : Clinical manifestations and pathologic findings of thin glumerular basement membrane disease, recognized as a common underlying disease of benign, familaiar and asymptomatic hematuria has not been reported systemically in Korera. We analyzed clinical and pathologic findings of patients who were diagnosed as thin glomerular basement membrane disease Methods : We analyzed clinical and pathologic findings of twenty-six patients who were diagnosed as thin glomerular basement membrane disease by renal biopsy among who complained asymptomatic hematuria from 1990 to 2000. Results : The subjects were aged 9.4${\pm}$3.2 (3.0-15.8) years-old at onset of hematuria, and 11.1${\pm}$2.2 (4.7-16.3) years-old at renal biopsy. Sexual discrepancy was more common in girls (eight boys and eighteen girls). A family history of hematuria was found in 8 patients(30.7$\%$). Major clinical manifestation on admission was microscopic hematuria according to the findings of 3case(11.5$\%$) of gross hematuria, 23cases(88.5$\%$9) of microscopic hematuria, and 1 case(3.8$\%$) of proteinuria. Microscopic hematuria persisted in all cases. Kidney biopsy showed few changes by light microscopy, but IgM, C3 and fibrinogen deposit in mesangium was found by immunofluorescent microscopy in a few cases. Electron microscopic findings have revealed thinning of the glomerular basement membrane varied from 180.9${\pm}$35.8nm. Conclusion : Thin glomerular basement membrane disease might be a common cause of microscopic hematuria of children and family history was revealed in about 30$\%$. Clinical progression was good in majorities.(J. Korean Soc Pediatr Nephrol 5 : 1-8, 2001)

  • PDF