• 제목/요약/키워드: 금속판 내고정

검색결과 58건 처리시간 0.024초

무지외반증 교정을 위한 최소침습적 근위 중족골 횡절골술 및 골수강 내 금속판 고정: 증례 보고 (Minimally Invasive Proximal Transverse Metatarsal Osteotomy Followed by Intramedullary Plate Fixation for Hallux Valgus Deformity: A Case Report)

  • 김종훈;서진수;최준영
    • 대한족부족관절학회지
    • /
    • 제25권3호
    • /
    • pp.141-144
    • /
    • 2021
  • More than 120 surgical methods for the correction of hallux valgus deformities have been reported. For the correction of moderate to severe hallux valgus deformities with aesthetic demands, minimally invasive surgery at the proximal area can be considered. This paper reports a case of moderate hallux valgus deformity treated by a minimally invasive proximal transverse metatarsal osteotomy followed by intramedullary plate fixation.

DC 반응성 스퍼터링법으로 증착한 TiN/Al, TiCN/Al 박막의 전기적.기계적 특성 및 내부식성 평가

  • 이현준;송풍근
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.346-347
    • /
    • 2012
  • 최근 화석연료 대체 에너지원으로서 자동차용으로 연구 개발 및 응용되고 있는 고분자 전해질 연료전지(PEMFC: Proton exchange membrane fuel cells)에서 분리판(Bipolar Plate)은 스택 전체 무게의 80%, 스택 가격의 60% 정도로 가장 높은 비중을 차지한다. 분리판은 연료와 산화제를 공급해주는 통로 및 전지 운전 중에 생성된 물을 제거하는 통로 역할과 anode, cathode로서 전극 역할을 통해 스택 전력을 형성하는 핵심 기능과 전지와 전지 사이의 지지대 역할을 한다. 따라서 분리판은 전기전도성, 내부식성 및 기계적 특성이 우수해야함은 물론이고, 얇고 가벼우며 가공성이 뛰어나야 한다. 현재 가장 많이 사용되고 있는 금속 분리판 소재 중 스테인리스 스틸은 전기적, 기계적 특성 및 내부식성이 우수한 반면, 가격이 비싸고, 중량이 무거운 단점이 있다. 따라서 본 연구에서는 DC 반응성 마그네트론 스퍼터링법으로 전기적, 기계적 특성 및 내부 식성이 우수한 TiN, TiCN 박막을 스테인리스에 비해 중량이 1/3, 소재 단가가 1/4인 알루미늄 기판 위에 증착하여 박막 물성을 평가하였다. DC Power는 400 W, 기판과 타겟 사이의 거리는100 mm, 공정 압력은 0.5 Pa로 고정하였고, 3 inch의 지름과 순도 99.95%를 갖는 티타늄 타겟을 사용하였다. 공정 가스는 Ar을 주입하였으며, 질소와 탄소의 공급원으로는 질소($N_2$)와 메탄($CH_4$) 가스를 사용하여 챔버 내 주입혼합가스의 전체 유량을 50 sccm으로 고정시켰다. 증착된 박막의 전기적, 기계적 특성을 측정하였고, X-ray diffraction (XRD), Scanning electron microscope (SEM)을 이용하여 박막의 미세구조 및 표면 상태를 확인하였다. 또한, 내부식 특성을 평가하기 위해 potentiostatic, potentiodynamic 법을 이용하여 박막의 부식저항을 측정하였다. 증착된 TiN 박막의 경우 질소 함량의 증가에 따라 박막 증착속도는 감소하는 경향을 보였다. 이는 타겟 부근의 질소 라디칼 비율이 증가함에 따라 질화반응이 촉진된 것으로 생각된다. 또한, 증착된 TiN과 TiCN 박막은 반응성 질소 유량과 탄소 유량에 따라 각각 다른 미세구조를 가지는 것을 확인하였다. TiN과 TiCN은 NaCl형의 면심입방격자(FCC)로 같은 구조이며, 격자상수가 비슷하여 전율고용되어 TiCN을 형성하고, 탄소와 질소의 비에 따라 전기적 기계적 특성이 달라짐을 확인하였다.

  • PDF

Locking Compression Plate를 이용한 전위성 쇄골 간부 골절의 수술적 치료 (Operative Treatment of Fractures of the Midshaft Clavicle using Locking Compression Plate)

  • 정남식;홍기도;하성식;박성준;강정호;심재천
    • 대한정형외과스포츠의학회지
    • /
    • 제5권1호
    • /
    • pp.63-68
    • /
    • 2006
  • 목적: 전위성 쇄골 간부 골절의 치료로 관혈적 정복술 후 LCP를 사용하여 내고정을 시행한 환자를 대상으로 방사선학적, 임상적 결과를 분석하여 전위성 쇄골 간부 골절의 치료에 있어서 LCP의 유용성을 알아보고자 하였다. 대상 및 방법: 2003년 5월부터 2004년 11월까지 본원에서 쇄골 간부 골절에 대해 LCP를 이용한 관혈적 정복, 금속내 고정술을 시행하고 6개월 이상 추시가 가능하였던 26례를 대상으로 하였다. 수술 후 최종 평가는 방사선 결과와 fang s criteria를 이용한 임상적 결과로 분석하였다. 결과: 수술 후 평균 9.3주에 모든 예에서 지연유합 없이 골유합 되었으며 임상적으로 Kangs criteria에 따라 구분한 결과, 우수 이 상이 22례로 나타났다. 특히, 견관절 운동은 상완골 골절이 동반된 두 경우를 제외한 24례에서 2.9주내에 정상 범위로 빠른 회복을 보였다. 합병증으로는 견관절 운동 장애 2례, 수술 절개 부위의 켈로이드 형성 1례였으며 그 이외에 다른 주요 합병증은 없었다. 결론: 전위성 쇄골 간부 골절에서 LCP를 이용한 관혈적 정복 및 금속내 고정술은 기존의 금속판에 비해 수술 후 합병증을 줄이고 효과적인 골유합과 조기 견관절 운동에 도움을 줄 수 있는 좋은 치료 방법 중 하나라고 사료된다.

  • PDF

견봉 골절의 불유합으로 기인한 가관절증의 잠김 금속판을 이용한 치료 - 증례보고 - (Treatment of Pseudoarthrosis due to Nonunion of the Acromial Fracture with LCP - Case Report -)

  • 김용민;박경진;김동수;최의성;손현철;조병기;박지강;금상욱;정호승
    • Clinics in Shoulder and Elbow
    • /
    • 제16권2호
    • /
    • pp.130-134
    • /
    • 2013
  • 견봉 골절의 진단 및 치료 지연으로 발생한 통증을 동반한 가관절증은 수술적 치료를 요한다. 견봉은 두께가 얇은 편평골이므로 견고한 고정이 어렵기 때문에 견봉에서 발생한 가관절증의 치료는 매우 어렵다. 52세 다발성 외상환자에서 발생한 전위가 없는 견봉 골절을 보행 재활을 시작하며 통증이 유발될 때까지 발견하지 못하였다. 원위 요골용 가변각 잠김 금속판을 이용한 내고정술 및 자가 장골 이식술을 시행하였다. 술 후 9개월째 극상건 부분 파열이 있어, 관절경하 극상건 봉합술을 시행하였다. 술 후 9개월째 방사선 검사상 완전한 골유합을 얻었다. 극상건 봉합술 3개월 후 통증이 완화되었으며, 견관절 기능이 정상화되었다. 견고한 고정이 어려운 견봉 불유합 및 가관절증 증례에서 좋은 결과를 얻어 보고한다.

상완골 간부 골절 수술 후 발생한 요골신경 마비에서 시행한 초음파 검사 -증례 보고- (Ultrasonography in Radial Nerve Palsy after Surgery of Humerus Shaft Fracture - Case Report -)

  • 윤형문;고덕환;김형준;남경모;강대명
    • 대한정형외과 초음파학회지
    • /
    • 제5권2호
    • /
    • pp.106-112
    • /
    • 2012
  • 상완골 간부 골절에 대한 수술적 치료 후 발생하는 요골신경 마비는 흔치 않다. 하지만 수술 후 요골신경 손상 정도를 정확히 진단하고 예후를 예측하기가 어려워 수술적 치료를 요할 수 있다. 저자들은 상완골 간부 골절에 관혈적 정복 및 금속판 내고정 수술 후 발생한 요골신경 마비에서 초음파 검사를 시행하여 신경의 연속성을 확인하였다. 이 후 보존적 치료를 시행하여 마비가 회복된 1예를 경험하여 문헌고찰과 함께 보고하는 바이다.

  • PDF

잠김 압박 금속판을 이용한 상완골 근위부 골절의 치료 (Operative Treatment with Locking Compression Plate (LCP) in Proximal Humerus Fracture)

  • 하성식;김재영;홍기도;심재천;강정호;박광희
    • Clinics in Shoulder and Elbow
    • /
    • 제11권2호
    • /
    • pp.137-142
    • /
    • 2008
  • 목적: 잠김 압박 금속판(LCP)을 이용한 상완골 근위부 골절의 수술적 치료에 대한 임상적, 방사선적 치료 결과를 평가해보고자 하였다. 대상 및 방법: 2005년 1월부터 2007년 4월까지 상완골 근위부 골절에 대해 LCP를 이용해 치료받고 12개월 이상 추시가 가능했던 24예를 대상으로 하였으며, 남자는 8예, 여자는 16예이었다. 평균 연령은 68.9세(33~90)이었다. 임상적 결과는 Neer의 기능적 평가 방법을, 방사선적 결과는 골 유합 시기 및 경간각을 이용한 Paavolainen의 방법으로 평가하였다. 결과: 평균 골 유합 기간은 11.9주(8~15)이었다. Neer의 기능적 평가상, 만족 이상의 결과를 보인 경우는 21예(87%)이었고, Paavolainen의 방법에 의한 방사선적 결과가 양호 이상인 경우는 22예(91%)이었다. 3예(13%)에서 금속 실패, 무혈성 골 두 괴사, 관절 강직의 합병증이 각각 발생하였다. 결론: 상완골 근위부 골절에 대해 LCP를 이용한 내고정술은 비교적 양호한 임상적, 방사선적 결과 및 적은 합병증을 보여, 상완골 근위부 골절의 수술적 치료에 유용한 방법 중 하나로 판단된다.

전위된 관절내 종골 골절에 대한 금속판 내고정술에서 일시적 K-강선 고정의 효과 (The Effect of Temporary K-wire Fixation in the Plate Fixation for Displaced Intra-articular Calcaneal Fracture)

  • 양기원;김진수;문진선
    • 대한족부족관절학회지
    • /
    • 제18권3호
    • /
    • pp.119-123
    • /
    • 2014
  • Purpose: This study was designed to evaluate the clinical efficacy of temporary K-wire fixation in F-plate fixation for displaced intra-articular calcaneal fractures. Materials and Methods: Two groups (group 1 with F-plate fixation only and group 2 with temporary K-wire fixation and F-plate fixation) of patients were included in this study. The temporary K-wire was removed six weeks after the operation. Each group consisted of 33 cases. Rotational axis angles were measured radiographically and the foot and ankle outcome score (FAOS) was used for clinical assessment. Results: In group 1, the mean rotational axis angle was reduced from $27^{\circ}$ preoperatively to $5.59^{\circ}$ postoperatively and the angle at last follow-up was $9.94^{\circ}$. There was an increase in angle of $4.35^{\circ}$ between postoperative and the last follow-up measurement. In group 2, the mean rotational axis angle was reduced from $21.2^{\circ}$ preoperatively to $4.39^{\circ}$ postoperatively and the angle at last follow-up was $5.91^{\circ}$. There was an increase in angle of $1.52^{\circ}$ between postoperative and the last follow-up measurement. Significant difference in the changes of rotational axis angle was observed between the two groups. However, no significant difference in FAOS was observed between the two groups. Conclusion: Temporary K-wire fixation can prevent reduction loss when treating displaced intra-articular calcaneal fractures with an F-plate.

경골 원위부 골절 치료에서 최소 침습적 접근법을 통한 잠금 나사 금속판 고정술과 교합성 골수강 내 금속정 고정술의 비교 연구 (A Comparative Study of Interlocking IM Nailing and LCP Fixation through MIPPO Technique in the Treatment of Distal Metaphyseal Tibial Fracture)

  • 이창수;서진수;김지훈
    • 대한족부족관절학회지
    • /
    • 제12권1호
    • /
    • pp.80-85
    • /
    • 2008
  • Purpose: To evaluate and compare the outcome between interlocking IM nailing and LCP fixation in the treatment of distal metaphyseal tibial fracture. Materials and Methods: From January 2000 to December 2007, 17 patient were treated by interlocking IM nail and 13 patient were treated by LCP fixation for distal metaphyseal tibial fracture. Results: According to AO classification, there were 2 type A1 fracture (12%), 6 type A2 fracture (36%), 3 type A3 fracture (18%), 4 type B1 fracture (24%), 1 type B3 fracture (6%), 1 type C1 fracture (6%) in interlocking IM nailing group and 1 type A2 fracture (7.7%), 2 type A3 fracture (15.4%), 3 type B1 fracture (23%), 3 type B2 fracture (23%), 3 type C1 fracture (23%), 1 type C2 fracture (7.7%) in LCP fixation group. The clinical functional outcome (according to AOFAS score) is 75.6 point in IM nailing group and 81.5 point in LCP fixation group. In IM nailing group, 65% of patient showed satisfactory result and In LCP fixation group, 77% of patient showed satisfactory result. Conclusion: There is no difference on clinical results between IM nailing and MIPPO (minimal invasive percutaneous plate osteosynthesis) group in the treatment of distal tibia fracture. But MIPPO group have higher subjective satisfactory score and less complication rate. The weakness of our study is a small case number and limited follow-up and we believe a better designed prospective study will be needed.

  • PDF

견봉쇄골탈구와 원위쇄골골절에서 소절개를 이용한 Wolter금속판 내고정술 (Minimal incision Wolter Plate Fixation on the Displaced Lateral End Fracture of the Clavicle and the Acromioclayicular Dislocation)

  • 고상훈
    • Clinics in Shoulder and Elbow
    • /
    • 제5권1호
    • /
    • pp.23-28
    • /
    • 2002
  • Purpose Displaced lateral end fracture of clavicle and acromioclavicular dislocation type Ⅲ∼Ⅵ may be required surgical treatment. Material and Methods : From May 1998 to March 2001, we operated with Welter plate with minimal incision by one surgeon. Immediately, pendulum and passive exercise was initiated after surgery. The shoulder function was evaluated using UCLA score. Average follow up was on 28(12∼45) months. Results : All 11 patients were regained satisfactory function. Average UCLA score was 31.9(29~35) at last follow up. Conclusion . The merit of Welter plate fixation with minimal incision is simple technique, reduced surgical time, smaller scar than large plate, strong fixation, early exercise, reduced implant failure. The disadvantage is expensive, skin irritatatation by long hook. But Welter plate fixation with minimal incision is a good method of internal fixation and excellent clinical result in surgical treatment of type H displaced lateral end fracture of the clavicle and type Ⅲ∼Ⅵ acromioclavicular dislocation.

삽관 나사못(Cannulated screw)을 사용한 경골 과간 융기부 견열 골절의 관절경적 치료 기법 (Arthroscopic Cannulated Screw Fixation Technique for Avulsion Fracture of the Intercondylar Eminence of the Tibia)

  • 이기병;장호근;이석범;문영완;강기훈;이욱형
    • 대한관절경학회지
    • /
    • 제3권2호
    • /
    • pp.127-131
    • /
    • 1999
  • 경골 과간 융기부의 견열 굴절은 비교적 드물지 않게 관찰되는 손상으로, 전위된 견열 골절편은 해부학적 정복과 견고한 고정을 필요로 한다. 그러나 관절경적 수술 방법을 포함한 대부분의 잘 알려진 수술 방법들은 비교적 복잡한 수술 기법과 정교한 수술 술기를 필요로 하며, 이에 따른 수술 시간의 지연과 수술 합병증으로 창상 감염, 조기 성장판 폐쇄 및 조기 관절 운동을 제한하는 고정력의 소실 등이 발생할 수 있다. 이에 저자들은 전외측 및 중앙부, 내측 mid-patella 입구를 사용한 관절경적 기법을 이용하여, 골편의 정복에 삽관 나사못을 사용함으로써, 비교적 짧은 수술 시간 안에 만족스런 정복과 고정을 얻을 수 있었으며, 술 후 조기에 능동적 관절 운동을 허용할 수 있었다. 또한 분쇄 골절의 경우 와셔를 사용함으로써 만족스런 고정을 얻을 수 있었다. 저자들의 방법은 수술 기법의 용이함과 금속 제거 시의 안전성, IV형 분쇄 골절에도 적용할 수 있는 점, 추가적인 피부 절개가 필요없다는 점, 성장기 소아에서 성장판의 손상 가능성을 줄일 수 있는 등의 장점이 있다고 사료된다.

  • PDF