• Title/Summary/Keyword: 굴곡도

Search Result 1,395, Processing Time 0.038 seconds

Two Dimensional Size Effect on the Compressive Strength of Composite Plates Considering Influence of an Anti-buckling Device (좌굴방지장치 영향을 고려한 복합재 적층판의 압축강도에 대한 이차원 크기 효과)

  • ;;C. Soutis
    • Composites Research
    • /
    • v.15 no.4
    • /
    • pp.23-31
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section ($length{\;}{\times}{\;}width$) was investigated on the compressive behavior of a T300/924 $\textrm{[}45/-45/0/90\textrm{]}_{3s}$, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a $30mm{\;}{\times}{\;}30mm,{\;}50mm{\;}{\times}{\;}50mm,{\;}70mm{\;}{\times}{\;}70mm{\;}and{\;}90mm{\;}{\times}{\;}90mm$ gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

Verification of Skin Dose in Tomotherapy Using the Developed Phantom for Image Based Radiation Treatment System (영상 기반 치료 장비용 팬톰을 이용한 토모테라피 피부 선량 검증)

  • Park, Ji-Yeon;Chang, Ji-Na;Oh, Seung-Jong;Kang, Dae-Gyu;Jung, Won-Gyun;Lee, Jeong-Woo;Jang, Hong-Suk;Kim, Hoi-Nam;Park, Hae-Jin;Kim, Sung-Hwan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.88-96
    • /
    • 2009
  • Radiation treatment for skin cancer has recently increased in tomotherapy. It was reported that required dose could be delivered with homogeneous dose distribution to the target without field matching using electron and photon beam. Therapeutic beam of tomotherapy, however, has several different physical characteristic and irradiation of helical beam is involved in the mechanically dynamic factors. Thus verification of skin dose is requisite using independent tools with additional verification method. Modified phantom for dose measurement was developed and skin dose verification was performed using inserted thermoluminescent dosimeters (TLDs) and GafChromic EBT films. As the homogeneous dose was delivered to the region including surface and 6 mm depth, measured dose using films showed about average 2% lower dose than calculated one in treatment planning system. Region indicating about 14% higher and lower absorbed dose was verified on measured dose distribution. Uniformity of dose distribution on films decreased as compared with that of calculated results. Dose variation affected by inhomogeneous material, Teflon, little showed. In regard to the measured dose and its distribution in tomotherapy, verification of skin dose through measurement is required before the radiation treatment for the target located at the curved surface or superficial depth.

  • PDF

Characteristics of the Cenozoic crustal deformation in SE Korea and their tectonic implications (한반도 동남부 신생대 지각변형의 주요 특징과 지구조적 의의)

  • Son, Moon;Kim, Jong-Sun;Chong, Hye-Yoon;Lee, Yung-Hee;Kim, In-Soo
    • The Korean Journal of Petroleum Geology
    • /
    • v.13 no.1
    • /
    • pp.1-16
    • /
    • 2007
  • The southeastern Korean Peninsula has experienced crustal multi-deformations according to changes of global tectonic setting during the Cenozoic. Characteristic features of the crustal deformations in relation to major Cenozoic tectonic events are summarized as follows. (1) Collision of Indian and Eurasian continents and abrupt change of movement direction of the Pacific plate (50${\sim}$43 Ma): The collision of Indian and Eurasian continents caused the eastward extrusion of East Asia block as a trench-rollback, and then the movement direction of the Pacific plate was abruptly changed from NNW to WNW. As a result, the strong suction-force along the plate boundary produced a tensional stress field trending EW or WNW-ESE in southeastern Korea, which resultantly induced the passive intrusion of NS or NNE trending mafic dike swarm. (2) Opening of the East Sea (25${\sim}$16 Ma): The NS or NNW-SSE trending opening of the East Sea generated a dextral shear stress regime trending NNW-SSE along the eastern coast line of the Korean Peninsula. As a result, pull-apart basins were developed in right bending and overstepping parts along major dextral strike slip faults trending NNW-SSE in southeastern Korea. The basins can be divided into two types on the basis of geometry and kinematics: Parallelogram-shaped basin (rhombochasm) and wedged-shaped basin (sphenochasm), respectively. In those times, the basins and adjacent basement blocks experienced clockwise rotation and northwestward tilting contemporaneously, and the basins often experienced a kind of propagating rifting from NE toward SE. At about 17Ma, the Yonil Tectonic Line, which is the westernmost border fault of the Miocene crustal deformation in southeastern Korea, began to move as a major dextral strike slip fault. (3) Clockwise rotation of southeastern Japan Island (about 15 Ma): The collision of the Izu-Bonin Arc and southeastern Japan Island, as a result of northward movement of the Philippine sea-plate, induced the clockwise rotation of southeastern Japan Island. The event caused the NW-SE compression in the Korea Strait as a tectonic inversion, which resultantly tenninated the basin extension and caused local counterclockwise rotation of blocks in southeastern Korea. (4) E-W compression in the East Asia (after about 5 Ma): Decreasing subduction angle of the Pacific plate and eastward movement of the Amurian plate have constructed the-top-to-west thrusts and become a major cause for earthquakes in southeastern Korea until the present time.

  • PDF

Arthroscopic Transosseous Suture Repair for Bankart Lesion with a Flexible Drill Device - An Experimental and Preliminary Clinical Report - (유연성 천공기를 이용한 Bankart 병변의 골관통식 봉합 - 동물 실험 및 예비 임상 결과 보고 -)

  • Park, Jin-Su;Won, Ye-Yeon;Yoo, Jung-Han;Park, Yong-Wook;Noh, Kyu-Chul;Chung, Kuk-Jin;Kim, Hong-Kyun;Hwang, Ji-Hyo;Lee, Young-Bum;Suh, Il-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.72-78
    • /
    • 2010
  • Purpose: Too develop a flexible drill device that can be inserted into the shoulder joint so that arthroscopic transosseous suture repair for Bankart lesion is possible. Materials and Methods: We created a device composed of a flexible drill unit and a guide pipe unit. The flexible drill unit was made of flexible multifilament wires (1.2 mm in diameter) that was twisted into one cord so that it can flex in any direction and a drill bit (1.2 mm in diameter) that is attached onto one end of the flexible wire. The guide pipe unit was a 150 mm long metal pipe (2.0 mm in inner diameter and 3.0 mm in outer diameter), with one end bent to 30 degrees. The flexible drill set was inserted into the shoulder joint through the posterior portal of the joint. The guide pipe component was placed onto the medial wall of the glenoid so that the pipe was placed 5 mm posterior to the margin of the anterior glenoid rim. The flexible drill was driven through the glenoid by the power drill so that holes were made in the glenoid. A non- absorbable suture was passed through the hole. Tying of a sliding knot tying was accomplished over the capsule and labrum after making a stitch through the capsule and labrum with a suture hook loaded with suture passer. The same procedures were done at the 2 and 4 O'Clock positions of the glenoid. Results: Five cases with Bankart lesion received arthroscopic transosseous repair with our flexible drill device. There were no intraoperative problems. Neither redislocation nor subluxation was reported at final follow-up. Conclusion: Arthroscopic transosseous suture repair without suture anchors and easy tying of a sliding knot are possible with a flexible drill set.

Polarus Intramedullary Nail for Nonunion of Humerus neck (Polarus 골수정을 이용한 상완골 경부 불유합의 수술적 치료)

  • Kang, Ho-Jung;Kim, Sul-Gee;Yoon, Hong-Kee;Hahn, Soo-Bong;Kim, Sung-Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.112-123
    • /
    • 2007
  • Purpose: Evaluate the clinical results of humerus neck nonunion treated with Polarus intramedullary nail. Materials and Methods: 8 patients who underwent surgery for nonunion of humerus surgical neck fracture were included. All patients were female, the average age was 65 years. 5 out the total 8 cases initially received surgery, open reduction and internal fixation with metal plate in 1 case, Ender nail insertion in 2 cases, external fixator in 1 case and closed reduction and percutaneous pinning in 1 case. The other 3 non union cases initial received conservative managemnent. The average period of nonunion was 9 months in the operated group and 6.2 months in the conservative group. All 8 cases received closed reduction with intrameedullary Polarus nail and auto iliac bone graft. Union was confirmed radiologically, and functional evaluation was done with the UCLA functional criteria. Results: All 8 cases showed union on radiologic evaluation. Average time to union was 3.5 months, average follow up period was 27 months. Average UCLA shoulder evaluation score was 7.6 points preoperatively which improved to 26.3 points after surgery. Active shoulder flexion was 40.7 degrees preoperatiely which increased to 104 degrees after surgery. Shoulder abduction improved from 32.9 degrees preoperatively to 96.3 degrees after surgery. UCLA functional criteria was good in 5 cases and fair in 3 cases, which no poor cases. Conclusion: Polarus IM nailing and AIBG is a useful method for treating nonunion of humerus neck fracture with improvement in union and function.

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF

Postoperative Complications After Arthroscopic Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft (자가 슬개건을 이용한 전방 십자 인대 재건술의 수술 후 합병증)

  • Zhu, Fang Zhen;Yoo, Moon-Jib;Kim, Myung-Ho;Park, Hee-Gon;Bahng, Seung-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.122-127
    • /
    • 2008
  • Purpose: Evaluation and analysis of the incidence of postoperative complications after arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft. Materials and Methods: We reviewed 172 cases of arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft in anterior cruciate ligament tear without meniscal injury. We performed Lysholm knee score and KT-2000 testing, simple radiograph, physical examination as evaluation factor. Also, around knee pain, swelling, limitation of motion, patellofemoral crepitation, paresthesia and pain on kneeling were evaluated. Results: The average follow up period was 49.8 months. In 172 patients, 148 males and 26 femlaes were evaluated. The average age was 34.4 years. The Lysholm knee score improved from 51.9 points preoperatively to 90.8 points at final follow up. Clinical outcome was excellent in 83%, good in 11%, fair in 4% and poor in 2%. There were many cases of complications, 24 cases (14%) of around knee pain, 12 cases (7%) of swelling, 45 cases (26.2%) of patellofemoral crepitation, 52 cases (30%) of donor site paresthesia, 65 cases (38%) of pain on kneeling, 10 cases (5.8%) of limitation of motion at extension, 13 cases (8%) of limitation of motion at flexion and 2cases (1.2%) of patellar fracture. Conclusion: Although arthroscopic anterior cruciate ligament reconstruction using bone-patellar tendon-bone had good clinical results, many complications were noted. Some factors in surgical technique were suspected to be related to the complications and long term follow up will be necessary to further evaluated.

  • PDF

Patellar Inferior Pole: New Landmark for the Anteromedial Instrument Portal for Arthroscopic Surgery of the Medial Meniscus Posterior Horn (슬개골 하극: 내측 반월상 연골판 후각부에 대한 관절경 수술을 위한 전내측 기구 삽입구의 새로운 표식)

  • Kim, Young-Mo;Hwang, Deuk-Soo;Lee, June-Kyu;Shin, Hyun-Dae;Kang, Tae-Hwan;Kim, Dong-Kyu;Kim, Pil-Sung
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.128-134
    • /
    • 2008
  • Purpose: We prospectively evaluated the clinical usefulness of the patellar inferior pole (PIP) as a landmark of the anteromedial (AM) portal for the arthroscopic surgery of the medial mensiscus posterior horn (MMPH). Materials and Methods: Group 1 (50 normal left knees of adults), Group 2 (10 normal knees under anesthesia), and Group 3 (50 consecutive knees undergoing elective arthroscopic surgery for relatively simple intraarticular pathologies, or diagnostic arthroscopy) were included. In Group 1 and 2, the true lateral (A) and valgus stress lateral radiographs (B) on $30^{\circ}$ flexion were obtained, and the lines (AM portal line) passing through the PIP and distal-most medial femoral condyle (MFC) were drawn under the condition without considering the thickness of articular cartilage of MFC (1, 2-A, B group), and considering it as 2.5mm on B (1, 2-C group). Then, we investigated the meeting point of the AM portal line with medial tibial plateau (C-D percentage), and measured the distance between the PIP and the anterior joint line (E-length), and medial tibial-femoral joint space (F-length). In Group 3, the AM portal was made at the PIP level and clinical usefulness of the approach to the MMPH and body of the lateral meniscus (LM) was analyzed. Results: The average C-D percentage came out as 85.8, 101.3, 69.1% for each Group 1-A, B, C, and 102.4, 144.6, 116.8% for each Group 2-A, B, C. Measured E-length was an average of 15.1 (Group 1-A), 15.5 (Group 1-B, C), 13.1 (Group 2-A), and 12.9 mm (Group 2-B, C) and the change by valgus stress had no statistical significance. The F-length increased about 1.2 (Group 1) and 3.6 mm (Group 2) when valgus stress was applied, which had statistical significance (p<0.001, p<0.001). In Group 3, 49, 48 knees were classified as good for the MMPH, and the body of LM in aspect of the clinical usefulness of AM portal made on the PIP level. Conclusion: We identified the clinical usefulness of the PIP as a skin landmark of AM portal for the arthroscopic surgery of the MMPH.

  • PDF

The Follow-up Results of Anterior Cruciate Ligament Reconstruction Using The Flexible Reamer (유연성 연마기를 이용한 관절경적 전방 십자 인대 재건술의 추시 결과)

  • Chae, In-Jung;Wang, Joon-Ho;Choi, Gi-Won;Song, Dong-Ik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.18-23
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the clinical results of the function and stability of ACL reconstruction using the flexible reamer. Materials and Methods: We reviewed 98 patients who taken ACL reconstruction using the flexible reamer from March, 1999 to May, 2004. And the follow-up period was more than 12 months in all cases. We used the subjective tests including Lysholm knee score and 2000 International Knee Documentation Committee(IKDC) subjective knee score, and the objective tests such as anterior drawer test, Lachman test, pivot shift test, and KT-2000 arthrometer to evaluate the clinical results. Results: In the range of motion of the affected knee, the extension deficit more than 5 degree was 8 cases preoperatively and 1 case postoperatively. The flexion deficit more than 5 degree was 12 cases preoperatively and 2 cases postoperatively. The mean Lysholm knee score was 61.3 point(${\pm}3.5$ SD) preoperatively and 87.7 point(${\pm}2.0$ SD) postoperatively. The mean 2000 International Knee Documentation Committee(IKDC) subjective knee score was 49 point(${\pm}3.3$ SD) preoperatively and 84 point (${\pm}2.2$ SD) postoperatively. 93 cases were more than grade II in Lachman test preoperatively and 5 cases postoperatively. 71 cases were more than grade II in pivot shift test preoperatively but 89 cases were negative postoperatively. The mean maximal manual difference by KT-2000 arthrometer was 6.8 mm(${\pm}1.9$ SD) preoperatively and 1.8 mm(${\pm}0.8$ SD) postoperatively. Conclusion: ACL reconstruction using the flexible reamer achieved the ideal isometric point of femur and anatomic graft placement, so we could obtain good results, especially in rotational stability.

  • PDF

A Comparison of Outcomes after Early and Delayed Reconstruction in the Acute Posterior Cruciate Ligament Injuries (급성 후방십자인대 손상 환자에서 조기 재건군과 지연 재건군의 결과 비교)

  • Lee, Yong Sik;Lee, Soo Won;Seo, Byung Ho;Kim, Yoon Gi
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.31-37
    • /
    • 2013
  • Purpose: This study performed to compare degree of joint stiffness and clinical results between early and delayed reconstruction of acute posterior cruciate ligament (PCL) injuries. Materials and Methods: Thirty-two Patients who underwent PCL reconstruction between March 2008 and October 2011 enrolled this study. We performed transtibial single bundle reconstruction using the allo-achilles tendon in all cases. We divided the patient into two groups, early reconstruction group underwent surgery before a week, delayed reconstruction group underwent surgery after 3 weeks, before 6 weeks. All the patients underwent aggressive joint motion exercise till surgery and enrolled post operative rehabilitation program. We checked posterior drawer stress radiography, range of motion, the Lysholm score, the International Knee Documentation Committee (IKDC) score and the Tegner score to evaluate the results. Results: At the final follow up the Lysholm score was 92.1 in the early group and 93.8 in the delayed group. All the cases were rated above B (near normal) on IKDC score (p=0.808, p=0.722). The Tegner score was 6.6 in the early reconstruction group and 6.2 in the delayed group (p=0.480), The average of maximum flexion and extension angle was $133.9^{\circ}$, $1.4^{\circ}$ in the early group and $133.6^{\circ}$, $1.1^{\circ}$ in the delayed group (p=0.560, p=0.581), no complication such as deep vein thrombosis or infection, no difference in posterior drawer stress radiography (p=0.750). Conclusion: We could obtain satisfactory clinical results in both the early and delayed reconstruction groups of acute PCL injuries. Therefore, the early reconstruction of PCL performed before a week could be one of the treatment options for acute PCL injury.

  • PDF