• Title/Summary/Keyword: 관찰-추천

Search Result 192, Processing Time 0.026 seconds

Endoscopic Radial Artery Harvest: Techniques & Results (내시경을 이용한 요골동맥 수확법의 수술 방법과 결과)

  • Jeong, Young-Kyun;Lee, Jong-Tae;Cho, Jun-Yong;Kim, Kyu-Tae;Chang, Bong-Hyun
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.35-41
    • /
    • 2006
  • Background: The radial arteries are being used more often for coronary artery bypass grafting, We tried to the endoscopic radial artery harvest to reduce the cosmetic problems and neurologic complications of the conventional open harvesting and report the techniques and early results. Material and Method: The 86 patients underwent coronary artery bypass grafting between May 2003 and April 2005 had their nondominant radial artery endoscopically removed through a 2 cm incision at the wrist. The radial pedicle was dissected and was divided at antecubial area through a 5 mm counterincision. Result: The 23 patients complained of neuralgias on territory of superficial raidal none but no one complained of neuralgias on territory of lateral antebrachial cutaneous none. There was no functional impairment of the hand. There was no wound complication except a localized hematoma. All patients were contacted by telephone after postoperative 7.9$\pm$3.6 months. The 4 patients still complained of neuralgia. All the patients were satisfied with the aesthetics of the wounds. The multidetectional tomography was done on the 66 patients for the estimation of early patency of radial artery. There were 2 cases of stenosis and a case of occlusion. Conclusion: Endoscopic radial artery harvest had no functional impairment of the hand, lesser rate of neurologic complications and outstanding aesthetics. The results of early patency of the radial artery was similar to conventional methods. Therefore, we think that endoscopic radial artery harvest is the optimal procedure.

An Evaluation of the Accuracy of Mini-Wright Peak Flow Meter (mini-Wright Peak Flow Meter에 의한 PEFR 측정의 정확도)

  • Koh, Young-Il;Choi, In-Seon;Na, Hyun-Ju;Park, Seok-Chae;Jang, An-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.298-308
    • /
    • 1997
  • Background : Portable devices for measuring peak expiratory flow(PEF) are now of proved value in the diagnosis and management of asthma and many lightweight PEF meters have become available. However, it is necessary to determine whether peak expiratory flow rate(PEFR) measurements measured with peak flowmeters is accurate and reproducible for clinical application. The aim of the present study is to define accuracy, agreement, and precision of mini-Wright peak flow meter(MPFM) against standard pneumotachygraph. Methods : The lung function tests by standard pneumotachygraph and PEFR measurement by MPFM were performed in a random order for 2 hours in 22 normal and 17 asthmatic subjects and also were performed for 3 successive days in 22 normals. Results : The PEFR measured with MPFM was significantly related to the PEFR and $FEV_1$ measured with standard pneumotachygraph in normal and asthmatics(for PEFR, r = 0.92 ; p < 0.001 ; for $FEV_1$, r = 0.78 ; p < 0.001). The accuracy of MPFM was within 100(limits of accuracy recommeded by NAEP) in all the subjects or 22 normal, mean difference from standard pneumotachygraph being 16.5L/min(percentage of difference being 2.90%) or 10.6L/min(percentage of difference being 1.75%), respectively. According to the method proposed by Bland and Altman, the 95% limits of the distribution of differences between MPFM and standard pneumotachygraph after correction of PEFR using our regression equation were +38.2 and -71.5L/min in all the subjects or 20.49~+9.49L/min in 22 normal and was similar to the intraindividual agreements for 3 successive days in normal. There was no statistically significant difference of PEFR measured with MPFM and standard pneumotachygraph among three days(p > 0.05) and the coefficient of variation($2.4{\pm}1.2%$) of PEFR measured with MPFM was significantly lower than that($5.2{\pm}3.5%$) with standard pneumotachygraph in normal (p < 0.05). Conclusion : This results suggest that the MPFM was as accurate and reproducible as standard pneumotachygraph for monitoring of PEFR in the asthmatic subjects.

  • PDF

Characterization of Biopesticides (Bacillus thuringiensis) Produced in Korea (국내에서 생산된 Bacillus thuringiensis 살충제의 특성)

  • Kil, Mi-Ra;Kim, Da-A;Choi, Su-Yeon;Paek, Seung-Kyoung;Kim, Jin-Su;Jin, Da-Yong;Hwang, In-Chon;Yu, Yong-Man
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.3
    • /
    • pp.201-209
    • /
    • 2007
  • Characteristics of the 5 biopesticides that included Bacillus thuringiensis and on the domestic markets were investigated. These products were contained different strains of B. thuringiensis, for examples; product A and E was B. thuringiensis subsp aizawai; product B was B. thuringiensis; product C was B. thuringiensis Berline var. kurstaki; product D was B. thuringiensis var. kurstaki. Number of active spores were counted because they could influence the bio-activity against target pests. Only product C are contained the fixed quantity as its label, however, product D and E were a tenth part, and product A and B were a hundredth part of their descriptions. The pHs of product A and B were measured 3.67 and 3.73, and C, D and E were 5, respectively. Typical bypyramidal crystals produced from B. thuringiensis was found in only product C under a phase contrast microscope. For the uniform formulation of products that conformed whether B. thuringiensis were equally spreaded on the crops, B. thuringiensis in the C, D and E were equally grown on the nutrient agar medium As a results, product A were more different from product C than any other products. When product A and C were bioassayed against different larval stages of diamondback moth, their mortalities with spraying application were showed 100% after 48 hours.

Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM (CAD-CAM을 이용한 3D printing, milling, casting 방법의 비귀금속 코핑의 지대치 변연 적합도 연구)

  • Seo-Rahng Kim;Myung-Joo Kim;Ji-Man Park;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • Purpose. The purpose of this study was to examine the correlation between the finish line designs and the marginal adaptation of nonprecious metal alloy coping produced by different digital manufacturing methods. Materials and methods. Nonprecious metal alloy copings were made respectively from each master model with three different methods; SLS, milling and casting by computer aided design and computer aided manufacturing (CAD-CAM). Twelve copings were made by each method resulting in 72 copings in total. The measurement was conducted at 40 determined reference points along the circumferential margin with the confocal laser scanning microscope at magnification ×150. Results. Mean values of marginal gap of laser sintered copings were 11.8 ± 7.4 ㎛ for deep chamfer margin and 6.3 ± 3.5 ㎛ for rounded shoulder margin and the difference between them was statistically significant (P < .0001). Mean values of marginal gap of casted copings were 18.8 ± 20.2 ㎛ for deep chamfer margin and 33 ± 20.5 ㎛ for rounded shoulder margin and the difference between them was significant (P = .0004). Conclusion. Within the limitation of this study, the following conclusions were drawn. 1. The variation of finish line design influences the marginal adaptation of laser sintered metal coping and casted metal coping. 2. Laser sintered copings with rounded shoulder margin had better marginal fit than deep chamfer margin. 3. Casted copings with deep chamfer margin had better marginal fit than rounded shoulder margin. 4. According to the manufacturing method, SLS system showed the best marginal fit among three different methods. Casting and milling method followed that in order.

Clinical Study on Thoracic Actinomycosis (흉부 방선균종의 임상적 고찰)

  • Hong, Sang-Bum;Kim, Woo-Sung;Lee, Jae-Hwan;Bang, Sung-Jo;Shim, Tae-Son;Lim, Chae-Man;Lee, Sang-Do;Koh, Youn-Suck;Lee, In-Chul;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1058-1066
    • /
    • 1998
  • Background: Actinomycotic infection is uncommon and primary actinomycosis of the lung and chest wall has been less frequently reported. This disease may present as chronic debilitating illness with radiologic manifestation simulating lung tumor, pulmonary infiltrating lesion, or chronic suppuration. Diagnosis of choice was not definded yet and role of bronchoscopy on diagnosis was not described yet. Methods: From 1989 to 1998, we experienced 17 cases of thoracic actinomycosis. We have reviewed the case notes of 17 patients with thoracic actinomycosis. The mean age at presentation was $53{\pm}13$ years, 11 were male. Results: Cough, hemoptysis, sputum production, chest pain and weight loss were the commonest symptoms. The mean delay between presentation and diagnosis was $6.6{\pm}7.8$ months. There were six patients who presented with a clinical picture of a suppurative lesion and eleven patients were suspected of having primary lung tumor initially. In no cases was made an accurate diagnosis at the time of hospital admission. Associated diseases were emphysema (1 case), bronchiectasis (2 cases) and tuberculosis (2 cases). Bronchoscopic findings were mucosal swelling and stenosis(n=4), mucosal swelling, stenosis and necrotic covering (n=2), mass (n=3), mass and necrotic covering (n=1) and normal(n=6). Radiologic findings were mass lesion(n=8), pneumonitis(n=3), atelectasis(n=3), pleural effusion(n=2), and normal(n=3). Final diagnosis was based on percutaneous needle aspiration and biopsy (n=3), bronchoscopic biopsy specimens (n=9), mediastinoscopic biopsy (n=1) and histologic examination of resected tissue in the remaining patients(n=4) who received surgical excision. Among 17 patients, 13 were treated medically and the other 4 received surgical intervention followed by antibiotic treatment. Regarding the surgically treated patients, suspected malignancy is the most common indication for operation. However. both medically and surgically treated patients achieved good clinical results. Conclusion: Thoracic actinomycosis is rare. but should still be considered in the differential diagnosis of a chrinic, localized pulmonary lesion. Thoracic actinomycosis may co-exist with pulmonary tuberculosis or lung cancer. If the lesion is located in the central of the lung. the bronchoscopy is recommanded for the diagnosis.

  • PDF

A three-dimensional finite-element analysis of influence of splinting in mandibular posterior implants (스프린팅이 하악 구치부 임플랜트 보철물의 응력분산에 미치는 영향에 관한 삼차원 유한요소분석 연구)

  • Baik, Sang-Hyun;Jang, Ik-Tae;Kim, Sung-Kyun;Koak, Jai-Young;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.157-168
    • /
    • 2008
  • Statement of problem: Over the past two decades, implant supported fixed prosthesis have been widely used. However, there are few studies conducted systematically and intensively on the splinting effect of implant systems in mandible. Purpose: The purpose of this study was to investigate the changes in stress distributions in the mandibular implants with splinting or non-splinting crowns by performing finite element analysis. Materials and methods: Cortical and cancellous bone were modeled as homogeneous, transversely isotropic, linearly elastic. Perfect bonding was assumed at all interfaces. Implant models were classified as follows. Group 1: $Br{{\aa}}nemark$ length 8.5mm 13mm splinting type Group 2: $Br{{\aa}}nemark$ length 8.5mm 13mm Non-splinting type Group 3: ITI length 8.5mm 13mm splinting type Group 4: ITI length 8.5mm 13mm Non-splinting type An load of 100N was applied vertically and horizontally. Stress levels were calculated using von Mises stresses values. Results: 1. The stress distribution and maximum von Mises stress of two-length implants (8.5mm, 13mm) was similar. 2. The stress of vertical load concentrated on mesial side of implant while the stress of horizontal load was distributed on both side of implant. 3. Stress of internal connection type was spreading through abutment screw but the stress of external connection type was concentrated on cortical bone level. 4. Degree of stress reduction was higher in the external connection type than in the internal connection type.

Analysis of Occlusal Contacts Using Add-picture Method (Add-picture 방법을 이용한 교합접촉점 분석)

  • Park, Ko-Woon;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.45-58
    • /
    • 2013
  • The purpose of this study was to analyze the area of occlusal contact points using visual method. One subject was selected who had Angle Class I, normal dentition, without dental caries, periodontal disease and temporomandibular disorders. Forty times PVS impressions were taken and 10 pairs casts were fabricated using dental super hard stone. After mounting the casts with customized loading apparatus, 78.9kg/f force was loaded as a maximum biting force. In T-Scan method, occlusal contact points measurement was repeated twice. Then, using Photoshop program (Adobe photoshop CS3, Adobe. San Jose, USA), the pixels which indicated occlusal contact points by color was recognized, and the distribution of recognized pixels were calculated to area. In Add picture method, polyether bite material applied to the occlusal surface of the casts. Then, the image of the translucent areas was recorded and classified $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area by the amount of transmitted light. To acquire occlusal surface, the numbers of pixels from the photograph of the contact area indicated cast converted to $mm^2$. The mean occlusal contact area by two methods was statistically analyzed (paired t-test). Part of the red and pink area in T-Scan image were almost equivalent to the $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$ area in Add picture image. The distribution of occlusal contact points were similar, but the average area of occlusal contact points was wider in T-scan image (P<.05). Pink and red area in T-scan image was wider than $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ area in Add picture image (P<.05), but similar to $0{\sim}60{\mu}m$area in Add picture image (P>.05). Occlusal contact points in T-scan image did not indicate real occlusal contact points. Occlusal contact areas in T-scan method were enlarged results comparing with those in Add picture method.

Suitability Assessment of Domestic Natural Waters as a Culture Medium for Daphnia magna (Daphnia magna의 배양배지로서 국내 자연수의 적절성 평가)

  • Yeom, Dong-Hyuk;Jeon, Chan-Sig
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.3
    • /
    • pp.271-277
    • /
    • 2012
  • The present study was conducted to assess the suitability of domestic natural waters as a Daphnia magna culture medium. In order to assess survival rate and reproductive output, young female daphnids (parent animals), aged less than 24 hours at the start of the test and produced in the Elendt M4 medium, were exposed to Elendt M4 medium, de-chlorinated tap water, and natural mineral water for 21 days. D. magna cultured in Elendt M4 medium (reference medium) and natural mineral water met the criteria of OECD No. 211, Daphnia magna Reproduction Test Guidelines in terms of percent adult survival, first day of reproduction, and average young production. However, the mortalities of adult daphnids observed in de-chlorinated tap water were more than 20% in two reproduction tests for 21 days. Mortality was observed on exposure days 13, 15, and 18 in de-chlorinated water. The use of D. magna is recommended in water of hardness >80 mg $CaCO_3\;L^{-1}$. However, the hardness of de-chlorinated tap water used in the present study was 50~53 mg $CaCO_3\;L^{-1}$. Therefore, it is judged that the delayed mortalities observed in de-chlorinated tap water were caused by a rapid decreased in hardness when the medium was changed from Elendt M4 to de-chlorinated tap water. When D. magna is cultured using domestic natural waters (underground water, surface water, and de-chlorinated water), the quality-control (QC) data should be maintained through a standardization for health assessment method, toxicity test method using reference chemical, test intervals of reference toxicant toxicity test, and data treatment and interpretation. In the long term, national research programs are needed for the development of test species which are representative of domestic aquatic environmental conditions among indigenous daphnids.

Ecological Characteristics of Local Collections of Eleocharis kuroguwai Ohwi. and Their Geographical Differentiation (올방개 지방수집종(地方蒐集種)들의 생태적(生態的) 특성(特性) 및 그의 지리적(地理的) 분화(分化)에 관한 연구(硏究))

  • Kwon, Yong-Woong;Seong, Ki-Yeong
    • Korean Journal of Weed Science
    • /
    • v.3 no.1
    • /
    • pp.23-28
    • /
    • 1983
  • To study ecological characteristics of Eleocharis kuroguwai occuring in Korea its propagules were collected from 6 locations from the northern part to the southern part of Korea (Chuncheon, Suweon, Iri, Jeonju, Gwangiu and Milyang) in 1981, cultured and replanted 3 times (May 20, June 5, June 20) in 1982. They flowered from August 5 to August 27 when they were planted on May 20, and from August 20 to August 27 when they were planted on Tune 20. Plant height, number of tillers and top fresh weight/$m^2$ were 50-90cm, 500-875, and 175-750g, respectively when they were planted on May 20, and 40-70cm, 250-625, 325-625g, respectively when they were planted on June 20. Number of tubers per plant were 0.98-1.98 when they were planted on May 20, and 1.81-2.87 when they were planted on June 20. Eleocharis kuroguwai from Chuncheon or Suweon was more open in plant type, shorter in plant height, narrower in diameter of pedicel and shorter in inflorescence than those from Iri, Jeonju or Gwangju. Each of the local collections may be regarded as different ecotype, based on the above differences in morphology and responses in growth and flowering to the planting dates. The results appear to imply that Eleocharis kuroguwai weeds occurring in various locations of Korea are different one another in competitive avility with rice crop.

  • PDF

Improvement of Dispersibility of Parched Cereal Powder by Agglomeration Treatment (응집처리를 통한 미숫가루의 분산성 개선)

  • Lee, Chang-Sung;Lee, Keun-Taik
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.385-390
    • /
    • 1998
  • The effect of agglomeration treatment was examined to prevent the parched cereal powder from clumping when it is blended with water. Parched cereal powder was composed of 66.9% carbohydrate, 7% water, 12.1% crude protein, 12.1% crude fat and 1.9% ash, respectively. Particle size of parched cereal powder was generally enlarged by agglomeration treatment. This phenomenon was confirmed by particle size analyzer and microscopic observation. The color of agglomerated sample was shown to be slightly darker than the untreated sample. The water absorption indices of agglomerated samples which were steamed for 2min and re-dried were significantly increased as compared with the untreated sample. The water solubility indices of agglomerated samples showed generally lower values than those of untreated samples. In views of quality and processing time, the optimum condition of agglomeration treatment for manufacturing well-dispersable parched cereal powder in water was 15min re-drying after 2min steaming. It is concluded that the agglomeration treatment improves the dispersibility of parched cereal powder and thus facilitates the intake of it after mixing with water.

  • PDF