• Title/Summary/Keyword: 공기막 압력

Search Result 44, Processing Time 0.027 seconds

A Strady-State One-Dimensional Analysis of an Oxygen Electrode in Stationary and Flowing Liquid (정체 및 유동액체에서 산소전극의 안정상태 일차원적 해석)

  • 김태진
    • KSBB Journal
    • /
    • v.4 no.2
    • /
    • pp.150-156
    • /
    • 1989
  • The chaacterisitics of a commercial membrance-coverd electrode in air-saturated saline solution were investigated in terms of a steadystate one-dimensional model. The electrode system miiersed in an aqueous medium consists of three layers: an external concentration boundary layer, a membrance, and an inner electrolyte layer. The membrance can be permeabld to the water and impermeable to the ionic species. In stationary midium, the water migrates from the external medium to the inner electrolyte layer until a thermodynamic equilibrium is reached. In a following midium, however, there is a reverse direction of water movement due to the hyrodynamic pressure differential until both thickness of the electrolyte layer and the membrance are equal.

  • PDF

Liquid Velocity and Local Fouling in Coagulation-submerged Microfiltration Module for Drinking Water Treatment (정수처리를 위한 응집-침지식 정밀여과 모듈의 유체유속 및 국부오염)

  • Choi, Youngkeun;Kim, Hyun-Chul;Noh, Soohong
    • Membrane Journal
    • /
    • v.25 no.3
    • /
    • pp.268-275
    • /
    • 2015
  • Effects of aeration intensity on local fouling were investigated in submerged membrane modules. Higher liquid velocities were observed at the section with the lower fiber packing density. The liquid velocity is increased with increasing the gas-liquid injection factor. The high shear stress coincided with the high liquid velocity. The shear stress increases with the increasing of gas-liquid injection factor and the liquid velocity improves with the increasing of gas-liquid injection factor. Irreversible fouling resistance ($R_{ir}$) of the fiber position is significant in a local region of high suction pressure near the suction point of the fiber (position 1). The ratio of $R_{ir}/R_m$ and $R_{ir}/R_r$ of position 1 was highest compared to the position 2 and 3. Irreversible fouling resistances results confirmed the preferential deposition of foulants near the suction part of the fiber where the local suction pressure is the highest and correspondingly, more particles are accumulated to the membrane surface. The effects of local fouling along the fiber length are significant factors to optimize the design of submerged modules.

Optimization of Membrane Separation System for Carbon Dioxide Recovery from Combustion Gases (연소기체로부터 이산화탄소 회수를 위한 막 분리 공정의 최적화)

  • Han, Myungwan;Kim, Miyoung;Kim, Beom-Sik
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.222-229
    • /
    • 2005
  • Five stage enriching membrane system for separating combustion gas (air 90%, $CO_2$ 10%) was proposed and simulated by using Aspen plus and Excel. The system recovers 90% $CO_2$ of the combustion gas and the purity of $CO_2$ recovered was more than 99%. Optimization yields a reduction in membrane area as well as operating and capital cost. Retentate concentration and permeate pressure of each stage were chosen as optimization variables. By analyzing the optimization results, we derived several design guide lines for the enriching membrane system.

Suction Pressures with respect to the Operational Modes using the Multi-bore Capillary Membranes in the Membrane Bioreactor (생물막 반응기내 다공성 중공사형막을 이용한 운전방식에 따른 흡입 압력)

  • Kim, Min Hyeong;Koo, Eeung Mo;Lee, Min Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.31 no.5
    • /
    • pp.343-350
    • /
    • 2021
  • In this study the suction pressure was measured with respect to operational time by submersing the multi-bore capillary membrane module in membrane bioreactor(MBR). The hexagonal shape capillary module which has the nominal pore size of 0.2 ㎛, outer diameter of 6.4 or 4.2 mm was immersed in MLSS 8,000 mg/L active sludge aqueous solution, and confirmed changes with respect to permeation flux and air flow rate. It was operated by the filtration/relaxation(FR), FR with backwashing(FR/BW), and sinusoidal flux continuous operation(SFCO) modes. The suction pressure for the SFCO and FR modes was lower at 30 and 50 L/m2·hr, respectively. In addition, the suction pressure of the module with a small outer diameter was relatively low. The suction pressure of a large outer diameter was greatly increased, but it could be reduced by more than 40% by backwashing.

Nitrogen-Oxygen Separation Characteristics by Polyimide Membrane System for Controlled Atmosphere Storage (CA저장을 위한 폴리이미드 막 시스템의 질소-산소 분리특성)

  • 이호원;현명택;고정삼
    • Food Science and Preservation
    • /
    • v.5 no.3
    • /
    • pp.239-246
    • /
    • 1998
  • Polyimide membrane system was designed for manufacturing nitrogen-enriched gas, and basic technical data was suggested for appling this system to controlled atmosphere storage. The permeability characteristics of pure oxygen and nitrogen could be explained by dual-mode sorption model. There was substantial decrease in the permeation rates of oxygen, which is the more permeable gas, through the polyimide membrane due to the presence of nitrogen in comparison with pure oxygen. However, the permeation rates of nitrogen was increased by the presence of oxygen. The ideal separation factor was in the range of 5 to 6 in the range of temperature and pressure difference studied, and the separation factor of air was lower than the ideal separation factor. The increase of ideal separation factor with increasing temperature is due to the fact that the activation energy for oxygen is larger than that for nitrogen. Nitrogen concentration decreased rapidly with increasing product recovery, and it was found that this is a major operating factor to obtain nitrogen concentration required for controlled atmosphere storage. A relation equation, by which nitrogen concentration in storehouse can be predicted, was suggested under the establishment of a hypothetical model for controlled atmosphere storage process using polyimide membrane system.

  • PDF

Characteristics of Ultrafiltration and Spray Drying for Crude Protein Bound Polysaccharides Isolated from Agaricus blasei Murill (아가리쿠스버섯에서 분리한 조단백다당류의 막분리 및 분무건조 특성)

  • 홍주헌;윤광섭;최용희
    • Food Science and Preservation
    • /
    • v.11 no.1
    • /
    • pp.47-52
    • /
    • 2004
  • This study was conducted to investigate the characteristics of ultrafiltration and spray drying process for crude protein bound polysaccharide(CPBP) isolated from Agaricus blasei Murill. In ultrafiltration process, the permeate flux increased with the increase of operating pressure and temperature. The permeate flux declined continuously while the fouling materials were accumulated on the membrane as the operation time increased. In comparing of raw CPBP and filtered CPBP, the viscosity of CPBP treated UF was decreased and $\Delta$E value of treated samples was increased. Thermal efficiencies of spray drying process were increased by increasing inlet temperature, feed rate and feed concentration.

Heat/Mass Transfer Measurements on a Film Cooled Blade with Naphthalene Saturated Coolant (나프탈렌 포화공기가 분사되는 막냉각 홀을 가진 터빈 블레이드 표면의 열/물질전달 계수 측정)

  • Lee, Dong-Hyun;Rhee, Dong-Ho;Kim, Kyung-Min;Cho, Hyung-Hee;Kim, Beom-Su
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.433-436
    • /
    • 2010
  • In this paper, heat/mass transfer characteristics on a film cooled stationary rotor blade are investigated using the naphthalene sublimation method. A row-speed annular wind tunnel with a single annular turbine stage is used. Three rows of film cooling holes are machined on the leading edge of the test blade. Detailed heat/mass transfer distributions are measured with changing the blowing rate from 1.0 to 2.0. As the blowing ratio increases, overall heat/mass transfer increases and the lower peak formed on the pressure side were disappeared.

  • PDF

Mechanism of Gel Layer Removal for Intermittent Aeration in the MBR Process (MBR 공정에서 간헐공기주입에 따른 겔층 제거 메커니즘)

  • Noh Soo-Hong;Choi Young-Keun;Kwon Oh-Sung;Park Hee-Sung
    • Membrane Journal
    • /
    • v.16 no.3
    • /
    • pp.188-195
    • /
    • 2006
  • The purpose of this study was to investigate the effect of an intermittent aeration mode to reduce the membrane fouling in a submerged membrane process using the specifically devised module (YEF 750D-2). The fluid velocity on the module increased with increasing the supplied air volume, and decreased with the increment of MLSS in the biological reactor. The reduction rate of the fluid velocity was found to be $3\times10^{-4}m{\cdot}min/sec{\cdot}L$ per 1,000 mg MLSS/L increased. In the operation of the intermittent aeration, the intermitted stop of the aeration provoked the formation of a cake layer on the gel layer which was previously formed during the aeration, resulting in the highly increased TMP level. However, the TMP level could be significantly lowered by the subsequent backwashing and aeration that effectively removed the cake along with the gel layer on the membrane surface. In this study, the optimum condition for the intermittent aeration was determined to be aeration for 20 sec and pause for 20 sec.

Nitrogen and Phosphorus Removal in Long Term Pilot Plant Operation Using Submerged Hollow Fiber Membrane and Ferric Chloride (침지형 중공사막과 철염을 이용한 Pilot MBR 공정의 장기운전에 따른 질소, 인 제거 특성)

  • Cheong, Jin-Ho;Heo, Yong-Rok;Im, Jeong-Dae;Lee, Eui-Sin;Park, Myung-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1168-1173
    • /
    • 2005
  • Pilot scale vertical-type membrane bioreactor was operated to examine the effect of $FeCl_3$ injection on the removal of organics, nitrogen and phosphorous, and additionally trans-membrane pressure (TMP) was observed. The membrane type was hollow fiber membrane with pore size of $0.25\;{\mu}m$, and the material was polytetrafluoroethylene (PTFE). The membrane permeate was continuously removed by a pump under a constant flux ($25\;L/m^2/h$). Air back-flushing technique were adopted to reduce fouling. As a result, TMP was increased more slowly than that of the operation without air back-flushing, During long-term operation, approximately 310 days, the injection of $FeCl_3$ was effective not only in removing phosphorous chemically but also in reducing TMP increase. Furthermore, while the average COD and T-N concentration of the effluent without $FeCl_3$ injection was 14.3 mg/L and 6.0 mg/L respectively, that of effluent with $FeCl_3$ was 11.3 mg/L and 6.0 mg/L respectively, which confirmed the effects of $FeCl_3$.

플라즈마를 이용한 그래핀의 산화

  • Lee, Byeong-Ju;Jeong, Gu-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.460-460
    • /
    • 2011
  • 그래핀은 탄소원자로 구성된 2차원의 나노재료로서 우수한 기계적, 전기적, 광학적 특성을 지닌다. 이러한 특성들을 기반으로 그래핀은 디스플레이, 터치스크린, 전 자기 차폐재 등의 다양한 분야로의 응용이 가능하다고 예측되고 있다. 한편 이러한 특성은 그래핀의 구조 및 결함, 불순물 등에 의하여 변화한다고 알려져 있으며, 이러한 특성의 변화를 통해 전자소자로의 응용도 가능 하다고 예측되고 있다. 따라서 그래핀의 구조를 제어하고 적절한 결함 및 불순물을 부여하는 것은 그래핀의 기초물성 연구 뿐 아니라 응용연구 에 있어서도 매우 중요하다고 할 수 있다. 본 연구에서는 공기 플라즈마를 이용하여 그래핀의 구조변형을 도모하였다. 그래핀은 열화학 기상증착법 (thermal chemical vapor deposition; TCVD)을 이용하여 300 nm 두께의 니켈박막이 증착된 기판위에 합성하였다. 합성된 그래핀은 산화처리 시 기판의 영향을 배제하고자 트렌치(trench) 구조의 산화막 실리콘 기판위로 전사함으로서 공중에 떠 있는 (air suspended) 구조를 구현하였다. 산화처리를 위한 장치는 직류 플라즈마 장치를 이용하였으며 0.1 Torr의 압력에서 0.4W의 파워로 공기 플라즈마를 방전하여 5분간의 산화처리와 특성평가를 매회 반복함으로서 처리시간에 따른 산화처리의 영향을 관찰하였다. 그 결과 공기 플라즈마 산화처리를 통해 그래핀에 결함을 부여하고 그래핀의 구조변형이 가능함을 확인하였다. 그래핀의 특성분석을 위해서는 광학현미경, 라만 분광기, 원자간힘현미경 등을 이용하였다.

  • PDF