• Title/Summary/Keyword: 고층 주거 건물

Search Result 44, Processing Time 0.025 seconds

Evaluating the Wind-induced Response of Tall Building Changed by Arrangements of the Buildings (건물배치변화에 따른 고층건축물의 풍응답 평가)

  • Cho, Sang Kyu;Ha, Young Cheol;Kim, Jong Rak;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.3 s.70
    • /
    • pp.305-314
    • /
    • 2004
  • Many residential buildings and mixed-use (i.e., residential and commercial) buildings that are currently under construction in the country mainly consist of building clusters rather than single structures. Recent trends show single buildings that actually consist of two houses. The lower part of the building consists of a single dwelling space. However, the upper part of the building is split into two dwellings, considering the aspects of commercialism and appearance, such as ventilation and lighting. These tall and complex buildings not only have low mass and damping. They also depend on wind loads for their structural stability and serviceability, due to the interaction between the building groups and the wind. In architectural design, however, the interaction effects among neighboring houses within a building group have yet to be identified. In addition, it is difficult to predict these interaction effects. In this regard, this thesis aims to model patterns of architecture, which consist of two houses that are existing or under construction. Current structures are investigated by comparing their wind-reduced response interaction effects, based on the measured distance between two buildings, and the acceleration response through the wind tunnel test. The results of this study are expected to provide basic data for wind-induced response interaction effects of building groups. Furthermore, the outcomes are also intended to be used as data for more rational and economical structure design.

A Study on the Analysis of Environment Performances in High-Rise Residential Building Through Green Building Certification System (친환경건축물 인증제도 평가를 통한 고층 주거용 건물의 환경성능 분석)

  • Chae, Mun-Byoung;Cha, Min-Chul;Jae, Seong-Ho;Seok, Ho-Tae
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.281-286
    • /
    • 2006
  • In case of Korea, immovable property like location, land prise or investment value is more highly estimated than quality of life of residents for performance and value of apartment house, because of limited land area or high density of population. But the high level of life has recently caused the increasing demand in better life. As there is no cases to provide the house in bulk due to the housing market condition, it is necessary to evaluate performance and value of structure, disaster prevention safety, habitability, antiquated condition of building and equipment, maintenance condition and so on that has importantly influence on resident's life quality. So, this study aims to understand the actual condition of environmental performance for the present apartment by comparing the designated apartment, which is ready to have completed in Daegu, with the mixed use residential building, which gained the best grade for green building certification system. Also by analyzing and evaluating a right to enjoy sunshine, floor impact noise etc. and indoor air quality.

  • PDF

Some Critical Problems in Seismic Design of High-Rise RC Building frame Systems (고층 RC 건물골조시스템의 내진설계상 몇 가지 주요 문제점)

  • Lee Han-Seon;Jeong Seong-Wook;Ko Dong-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.727-734
    • /
    • 2005
  • High-rise residential buildings these days tend to adopt a building frame system as primary earthquake resisting structural system for some architectural reasons. But there exist several ambiguities in designing such building frame systems according to current codes with regards to : the effective stiffness property of RC cracked section in static and dynamic analyses, analytical model to evaluate story drift ratio, and deformation compatibility requirements of frames. The comparative study for these issues by appling KBC 2005 to a typical building frame system shows that demands of member strength and story drift ratio can be different significantly depending on engineer's Interpretation and application of code requirements. And a building frame system can be noneconomical, compared with the dual system, because of higher demands on strength or ductility in both frames and shear walls.

Structural Effect Evaluation of an Apartment Building Due to the Water Tank under Earthquake Load (지진발생시 아파트 옥탑층 물탱크의 구조적 영향평가)

  • 정은호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.29-40
    • /
    • 1999
  • High-rise building for dwelling has many factors to be considered in structural aspects. In particular, the higher the building, the bigger the lateral loads such as wind and earthquake due to its dynamic characteristics. Unlike the wind load, the earthquake load, even if the shape of the structures are similar, depends on structural characteristics and it is difficult to predict. For an apartment building, the water tank in the penthouse, due to its heavy weight, changes the behavior of a building when the earthquake occurs. The purpose of this study is to determine how the water tank affects the behavior of an apartment building when earthquake occurs. Dynamic analysis was accomplished on two cases - 1) water tank is considered 2) water tank is not considered - to understand how it affects the behavior of a high-rise apartment building. Structural design was accomplished to understand how the water tank and the peak acceleration affects each structural member. The effect of the water tank on the response of structure was large. Elsewhere the water tank has no effect on the design of a strutural member. However some structural members were affected when the peak acceleration of an earthquake is 0.4g.

  • PDF

Estimation of Velocity Pressure Exposure Coefficient using GIS (GIS를 이용한 풍속고도분포계수 산정)

  • Seong, Min-Ho;Choi, Se-Hyu
    • Spatial Information Research
    • /
    • v.19 no.1
    • /
    • pp.13-19
    • /
    • 2011
  • As an urbanization is in progress, the change of the planimetric features and topography including high-rise residential buildings commonly occur. The change of the planimetric features and topography causes occurrence of the strong wind and wind speed increase or decrease due to the effect of planimetric features and topography on the windward side even though the wind blows with the same speed. In the design standard, this change by wind speed is defined as the velocity pressure exposure coefficient, the value of coefficient is estimated and reflected by ground surface roughness, but in a reality, ground surface roughness is determined in accordance with the subjective judgement of designer and then the velocity pressure exposure coefficient is estimated, moreover the research and data for classification of ground surface roughness are insufficient. In this paper, we will estimate the velocity pressure exposure coefficient by the quantified method for classifying ground surface roughness by using GIS according to the height of a building targeting area where high-rise residential buildings are built lately. When the structure subjected to wind load is designed, reasonability of design and safety of structure will be more improved by using the estimation method of velocity pressure exposure coefficient presented in this study.

A Road Traffic Noise Management Using a Noise Mapping Simulation (소음지도 시뮬레이션을 이용한 도로교통소음 개선방안 연구)

  • Kim, Hyung-Chul;Jeong, Jea-Hun;Kwon, Woo-Taeg
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.7
    • /
    • pp.353-360
    • /
    • 2007
  • Rapid urbanization and population increasing are making a high-rise residential building and high-density residential area. According to spacial concentration of population is occurred road traffic noise problem. Now we are popularly using almost only noise barrier installation, but it makes many disfunctions such as poor landscape, low noise barrier performance and crimes. The purpose of this research is to figure out which is best method one the traffic noise management. Alternative are composed to building layout type ($30^{\circ},\;90^{\circ},\;180^{\circ}$), separation between road and residential building, noise barrier types(noise barrier only, noise barrier and forests and etc). The noise barrier are shown to reduce barrier and building layout angle $30^{\circ}$ position is the best comparing with horizontal and vertical layouts. The gab distance is decreased approximately noise level 5dB(A). We figured out there are noise important method except noise barrier wall and it was analyzed how much decreased. This can be very useful before making a road planning and residential building design.

Seismic Response of a High-Rise RC Bearing-Wall Structure with Irregularities of Weak Story and Torsion at Bottom Stories (저층부에 약층과 비틀림 비정형성을 가진 고층 비정형 RC벽식 구조물의 지진응답)

  • 이한선;고동우
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.6
    • /
    • pp.81-91
    • /
    • 2003
  • Recently, many high-rise reinforced concrete(RC) bearing-wall structures of multiple uses have been constructed, which have the irregularities of weak(or soft) story and torsion at the lower stories simultaneously. The study stated herein was performed to investigate seismic performance of such a high-rise RC structure through a series of shaking table tests of a 1: 12 model. Based on the observations of the test results, the conclusions are drawn as follows: 1) Accidental torsion due to the uncertainty on the properties of structure can be reasonably predicted by using the dynamic analysis than by using lateral force procedure. 2) The mode coupled by translation and torsion induced the overturning moments not only in the direction of excitations but also in the perpendicular direction: The axial forces in columns due to this transverse overturning moment cannot be adequately predicted using the existing mode analysis technique, and 3) the hysteretic curve and the strength diagram between base shear and torque(BST) clearly reveal the predominant mode of vibrations and the failure mode.

Accuracy Assessment of 3D Reconstruction Using LiDAR Data (LiDAR 자료를 이용한 3차원복원 정확도 평가)

  • Chung, Dong-Ki
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2005.11a
    • /
    • pp.81-104
    • /
    • 2005
  • Accurate 3D models in urban areas are essential for a variety of applications, such as virtual visualization, CIS, and mobile communications. LiDAR(Light Detection and Ranging) is a relatively new technology for directly obtaining 3D points. Because Manual 3D data reconstruction from LiDAR data is very costly and time consuming, many researchs is focused on the automatic extraction of the useful data. In this paper, we classified ground and non-ground points data from LiDAR data by using filtering, and we reconstructed the DTM(Digital Terrain Model) using ground points data, buildings using nonground points data. After the reconstruction, we assessed the accuracy of the DTM and buildings. As a result of, DTM from LiDAR data were 0.16m and 0.59m in high raised apartments areas and low house areas respectively, and buildings were matched with the accuracy of a l/5,000 digital map.

  • PDF

Patterns and Factors Causing Construction Waste Generation in High-Rise Housing Projects in Korea : A Case Study (고층 주거건물 프로젝트에서 발생하는 폐기물 발생패턴 및 발생 유발 요인 분석)

  • Cha, Hee-Sung;Shin, Dong-Woo;Kim, Jee-Hye
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.3 s.31
    • /
    • pp.159-168
    • /
    • 2006
  • In order to respond to interest and regulations in sustainable environment which is increasing, construction industry needs to establish a sustainable production system. When generation of wastes can be diminished and recycling of them raised in the construction site as a part of a sustainable production system, it might contribute to not only establishing a sustainable production system but also gaining economical profit. This study is a preliminary research for establishing a sustainable production system, which aims to identify construction waste generation patterns and factors causing construction waste generation. Case studies were implemented to investigate these patterns and factors.

A Study on the Right of Light Impact at Adjacent Residential Area by High-rise Residential Commercial Complex Building (상업지역내 고층건물의 인접주거 지역 일조권 영향에 관한 연구)

  • Lee, Sang-Hwa;Lee, Kyoo-Seock
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.2
    • /
    • pp.10-18
    • /
    • 2009
  • In order to determine the violation of right of light impact at adjacent residential area by high-rise building, analysis on the right of light for high-rise residential commercial complex building block at Gahngnam-ku, Seoul, Korea was carried out using Google Sketchup Pro. After the analysis th sunshine duration of B apartment decreased from 5 hours 16 minutes 3 hours 48 minutes by I hour 42 minutes after construction. It shows that the total sunshine duration is less than the Seoul City Government Standard which is more than 4 hours a day, or more than 2 consecutive hours. Lowering the heights of apartments by 54m would increase the total sunshine duration which would meet the Seoul City Government Standard by four hours seven minutes. Problems that rna lead to the violation on the right of light in the adjacent area should be discussed in advance and minimized by analyzing the right of light among buildings and structures which are scheduled to be constructed on the site during construction penni! process when high-rise building is proposed.