Analysis of Train Delay in Daejeon Metro (대전도시철도의 열차 지연운행 분석연구)

  • Kwon, Young-Seok;Lee, Jin-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • This study investigated the causes and problems of train operation impediments through the statistics analysis of 8 years'internal data of Daejeon Metropolitan Express Transit. By evaluating the risks regarding the system, equipment, and parts of high risk group, this study measured the Risk Index Severity, and applied the $5{\times}5$ Risk Assessment Matrix which is a method of risk management to calculate the scale of risk to analyze the safety level and allowance range. As a result, the car sector, the most serious risk, followed by machinery and equipment sector showed that the inherent risk. In particular, the door broken and the door rail signaling and control devices due to defects of the vehicle is high, but also the severity, and frequency are showing very frequent additional potential accidents. PSD also had defects in the machinery sector appeared to be the most dangerous of the PSD poor safety gates, it was found that the glass also involve the risk of mishandling and breakage of the PSD. This study intended to contribute to the transportation benefits through the safety and stable operation of Metropolitan Express Transit.

Embedding algorithm among star graph and pancake graph, bubblesort graph (스타 그래프와 팬케익, 버블정렬 그래프 사이의 임베딩 알고리즘)

  • Kim, Jong-Seok;Lee, Hyeong-Ok;Kim, Sung-Won
    • The Journal of Korean Association of Computer Education
    • /
    • v.13 no.5
    • /
    • pp.91-102
    • /
    • 2010
  • Star graph is a well-known interconnection network to further improve the network cost of Hypercube and has good properties such as node symmetry, maximal fault tolerance and strongly hierarchical property. In this study, we will suggest embedding scheme among star graph and pancake graph, bubblesort graph, which are variations of star graph. We will show that bubblesort graph can be embedded into pancake and star graph with dilation 3, expansion 1, respectively and pancake graph can be embedded into bubblesort graph with dilation cost O($n^2$). Additionally, we will show that star graph can be embedded into pancake graph with dilation 4, expansion 1. Also, with dilation cost O(n) we will prove that star graph can be embedded into bubblesort graph and pancake graph can be embedded into star graph.

  • PDF

Assessment of Post-LOCA Radiation Fields in Service Building Areas for Wolsong 2, 3, and 4 Nuclear Power Plants (월성 원자력 발전소 2,3,4호기에서의 LOCA 사고후 보조건물의 방사선장 평가)

  • Jin, Yung-Kwon;Kim, Yong-Il
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.53-64
    • /
    • 1995
  • The radiation fields following the large loss of coolant accident (LOCA) have been assessed for the vital areas in the service building of Wolsong 2, 3, and 4 nuclear power plants. The ORIGEN2 code was used in calculating the fission product inventories in the fuel. The source terms were based upon the activity released following the dual failure accident scenario, i.e., a LOCA followed by impaired emergency core cooling (ECC). Configurations of the reactor building, the service building, and the ECC system were constructed for the QAD-CG calculations. The dose rates and the time-integrated doses were calculated for the time period of upto 90 days after the accident. The results showed that the radiation fields in the vital access areas were found to be sufficiently low. Some areas however showed relatively high radiation fields that may require limited access.

  • PDF

Success Run Test for Reliability Demonstration of 1100℃ Gas Turbine Blades (1100℃급 가스터빈 동익의 무고장시험을 통한 HCF 신뢰성 평가)

  • Lee, Dooyoung;Goo, Jaeryang;Kim, Doosoo;Kim, Donghwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.107-111
    • /
    • 2017
  • The reliability on high cycle fatigue damage mechanism for new blades manufactured by reverse-engineering is demonstrated by success-run test. Turbine blades always experience various dynamic loads in turbine operation, as well as being in resonance condition and forced by fluid-induced vibrations mostly during run-up/down, which may accumulate high cycle damage to the blades. The accidents caused by blade failure especially incur not only a lot of troubles to the machinery but also huge financial losses. Therefore it is necessary to verify the reliability of blades in advance for the safe use. The success run test for the reliability demonstration is designed and performed for the new blades using the technique known as resonant high cycle fatigue testing.

Embedding Analysis Among the Matrix-star, Pancake, and RFM Graphs (행렬-스타그래프와 팬케익그래프, RFM그래프 사이의 임베딩 분석)

  • Lee Hyeong-Ok;Jun Young-Cook
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.9
    • /
    • pp.1173-1183
    • /
    • 2006
  • Matrix-star, Pancake, and RFM graphs have such a good property of Star graph and a lower network cost than Hypercube. Matrix-star graph has Star graph as a basic module and the node symmetry, the maximum fault tolerance, and the hierarchical decomposition property. Also it is an interconnection network that improves the network cost against Star graph. In this paper, we propose a method to embed among Matrix-star Pancake, and RFM graphs using the edge definition of graphs. We prove that Matrix-star $MS_{2,n}$ can be embedded into Pancake $P_{2n}$ with dilation 4, expansion 1, and $RFM_{n}$ graphs can be embedded into Pancake $P_{n}$ with dilation 2. Also, we show that Matrix-star $MS_{2,n}$ can be embedded into the $RFM_{2n}$ with average dilation 3.

  • PDF

Message Delivery and Energy Consumption Analysis on Pocket Switched Network Routing Protocols (Pocket Witched Network 라우팅 프로토콜의 메시지 전송 및 에너지 소비 분석)

  • Cabacas, Regin;Ra, In-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.6
    • /
    • pp.571-576
    • /
    • 2013
  • Despite the development of the Internet, both in terms of technology and coverage, there are still remote areas and scenarios where connectivity is very difficult to achieve. Pocket Switched Network is a network paradigm that takes the advantage of human mobility to disseminate data. Factors such as mobility of nodes, link failures, discharged batteries, are among the challenges that may compromise connectivity in these networks. This paper presents a performance analysis of existing routing schemes for PSN in terms of delivery probability, overhead ratio, average latency and average residual energy when the number of nodes is increased. We seek to identify a scheme that maximizes data delivery while minimizing communication overhead and thus extending the network lifetime.

A Study on Reliability Evaluation Using Dynamic Fault Tree Algorithm (시스템 신뢰도 평가를 위한 동적 결함 트리(Dynamic Fault Tree) 알고리듬 연구)

  • 김진수;양성현;이기서
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.10A
    • /
    • pp.1546-1554
    • /
    • 1999
  • In this paper, Dynamic Fault Tree algorithm(DFT algorithm) is presented. This algorithm provides a concise representation of dynamic fault tolerance system including fault recovery techniques with fault detection, mask and switching function. And this algorithm define FDEP, CSP, SEQ, PAG gate which captures the dynamic characteristics of system. It show that this algorithm solved the constraints to satisfy the dynamic characteristics of system which there are in Markov and also this is able to satisfy the dynamic characteristics of system which there are in Markov and also this is able to covered the disadvantage of Fault tree methods. To show the key advantage of this algorithm, a traditional method, that is, Markov and Fault Tree, applies to TMR and Dual-Duplex systems with the dynamic characteristic and a presented method applies to those. He results proved that the DFT algorithm for solving the problems of the system is more effective than the Markov and Fault tree analysis model..

  • PDF

Design and Implementation of Mathematical Model based Hierarchical Conflict Detection and Resolution (수리모형 기반의 계층적 열차경합관리 설계 및 구현)

  • Kim, Kyung-Min;Hong, Soon-Heum
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.687-694
    • /
    • 2008
  • Given the daily tactical schedule, the purpose of the traffic management system is to develop operating plan that will achieve the stated schedule as best as possible. The operating plan has to be modified during the day because of occurring disturbance(e.g. delay, infrastructure breakdown, etc.) Conflict detection and resolution(CDRS) are aimed for adjusting the distorted schedule to tactical schedule. Our research separate CDRS into two hierarchy modules, line conflict control module and station conflict control module. We define the role of each modules and design the cooperative architecture. We suggest the conflict detection and resolution approach based on mathematical model. These results can be implemented as prototype modules.

  • PDF

CFD Analysis to Suppress Condensate Water Generated in Gas Sampling System of HANARO (하나로 기체시료채취계통에서 생성된 응축수 억제를 위한 CFD 해석)

  • Cho, SungHwan;Lee, JongHyeon;Kim, DaeYoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.327-336
    • /
    • 2020
  • The high-flux advanced neutron application reactor (HANARO) is a research reactor with thermal power of 30 MW applied in various research and development using neutrons generated from uranium fission chain reaction. A degasifier tank is installed in the ancillary facility of HANARO. This facility generates gas pollutants produced owing to internal environmental factors. The degasifier tank is designed to maintain the gas contaminants below acceptable levels and is monitored using an analyzer in the gas sampling panel. If condensate water is generated and flows into the analyzer of the gas sampling panel, corrosion occurs inside the analyzer's measurement chamber, which causes failure. Condensate water is generated because of the temperature difference between the degasifier tank and analyzer when the gas flows into the analyzer. A heating system is installed between the degasifier tank and gas sampling panel to suppress condensate water generation and effectively remove the condensate water inside the system. In this study, we investigated the efficiency of the heating system. In addition, the variations in the pipe temperature and the amount of average condensate water were modeled using a wall condensation model based on the changes in the fluid inlet temperature, outside air temperature, and heating cable-setting temperature.

A Study on Determination of Capacity for Pump and Detention Pond in Small Basins for Flood Control (소유역에서 홍수조절용 펌프 및 유수지 규모의 결정에 관한 연구)

  • Ahn, Tae-Jin;Park, Jong-Yoon;Lyu, Heui-Jeong;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.3 s.134
    • /
    • pp.385-398
    • /
    • 2003
  • The concept of the effective storage ratio has been suggested to determine the size of detention pond by the previous researchers. The 11 pump - pond facilities in Dongdu-chun city were selected to analyze the critical duration for design rainfall and the storage ratio for each rainfall duration in this study It has been then found that the criteria of the maximum storage ratio is not reasonable for determining the size of detention pond because the difference of storage ratio with respect to each rainfall duration is too small. Moreover, since the size of pond compared with the pump capacity is not always big enough, the pump should be frequently operated, which may result in pump failure. Thus, the pond should be sufficiently sized to prevent the possibility of the pump failure due to frequent operation. According to the analyses for changing pump capacity, it has been found that if the function of the pond compared with the pump is concentrated, determining the size of pond based on the storage ratio is operationally feasible for even small basin. Thus, an improved procedure based on the storage ratio for determining the size of detention pond in small basin has been suggested. The results by the proposed procedure considering pump switching frequency may lead to reasonable pump operation. A simple linear programming model has been also adopted to figure out the relationship between pump capacity and pond size. It has been shown that the determination lot the size of detention pond based on conventional hydrologic flood routing in pond is feasible for only urban districts not rural areas.