• Title/Summary/Keyword: 검체

Search Result 651, Processing Time 0.027 seconds

Analysis of polyethoxylated ascorbic acid using spectrophotometry (분광광도계를 이용한 폴리에톡시레이티드 아스코르빈산 분석법 개발)

  • Wu, Zhexue;Liu, Kwang-Hyeon
    • Journal of Applied Biological Chemistry
    • /
    • v.59 no.4
    • /
    • pp.361-364
    • /
    • 2016
  • We developed a spectrophotometric assay method for polyethoxylated ascorbic acidusing 3-ethyl ascorbic acid as standard material. The analytical method was validated by linearity, accuracy, precision, and stability. The coefficient of variation of the precision of the assay was less than 3.4 %. The linearity of the calibration curves in the desired concentration range is good ($r^2$>0.998). 3-Ethyl ascorbic acid and polyethoxylated ascorbic acid were stable in stock solution at room temperature for up to at least 6 h. The developed assay could be used for the content analysis of polyethoxylated ascorbic acid in samples.

Aspect of Minerals in the Hair of Smokers (흡연자 모발에 함유한 미네랄 함량분석)

  • Lee Ju Young;Lee Mi Hwa;Choi Won Chul
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.2 s.83
    • /
    • pp.107-114
    • /
    • 2005
  • 모발은 고통 없이 검체를 채취할 수 있고 저장이 간편하며 인체에 장기간 축적된 미네랄과 중금속함량을 측정하는데 매우 적당한 재료이다. 그러므로 45세 전후의 남자두발을 검체로 하여 상습흡연자(3년 이상 하루 1갑 이상흡연자)와 비흡연자 그리고 청소년을 대상으로 15종의 영양원소와 8종의 독성원소, 그리고 15종류의 기타원소를 조사하여 이들 미네랄 함량의 기초 자료를 제시하고자 하였다. 총 38종류의 원소분석은 정확도를 기하기 위하여 Trace elements, Inc (Dallas, Tx, USA)사에 의뢰하였으며, 이곳에서는 유도결합 플라즈마 질량분석기를 사용하여 분석하였다. 결과는 흡연자가 비 흡연자에 비하여 영양원소는 대체적으로 비슷하였으나 특히 Mg(P<0.05)와 Cu함량이 각각 3.9와 2.4 ppm의 차이로 흡연자가 낮았고, 독성원소는 Hg(P<0.001)가 0.16과 0.31 ppm으로써 0.15 ppm 차이로 흡연자가 높은 특징을 보였는데, 이것은 최대허용치인 0.18 ppm과 비교해 보았을 때 약 2배 이상 초과하는 것이 였엇다. 이러한 원인들은 흡연에 있다고 볼 수 있으며, Hg의 중독증상은 중추신경 장애와 의욕상실, 만성피로를 일으킬 수 있으며 미나마타병의 원인물질로 알려져 있다. 한편,청소년과 성인에 있어서 영양원소의 함량은 Cu, P, Mn, B가 각각 3.2, 2.1, 0.016, 0.03 ppm의 차이로 성인에서 높았다. 그러나 생리활성물질인 Ca, Na, K은 각각 55.3, 15.2, 9.0 ppm의 차이로 청소년에서 높았는데, 이것은 성장기 청소년들에게 있어서의 특징이라고 할 수 있다. 독성원소는 Hg가 0.16 ppm으로 성인에서, Cd는 0.01 ppm으로 청소년에서 높았지만 각각 최대 허용치인 0.18과 0.014 ppm 이하였다.

Analysis of Nursing Students' Educational Needs about Corona19 Infection Control (간호대학생의 코로나19 감염관리 교육에 대한 요구 분석)

  • Yoo, Eun-Young
    • Journal of Digital Convergence
    • /
    • v.18 no.12
    • /
    • pp.335-341
    • /
    • 2020
  • This study aims to identify the importance and degree of performance of COVID19 infection control educational program for 4th grade nursing college students, and to prepare the basic data for developing COVID19 infection control nursing education program based on this study. Data were collected from January 6 to January 30, 2020 by using structured questionnaire from 72 senior nursing students at "A" City Nursing College. The overall average of importance of COVID19 infection control nursing was 4.4 out of 5, and the overall average of performance was 2.4 out of 5. The greatest difference in importance and performance were the sectors of personal protection(equipment dressing & undessing) and collecting safe sample. By analyzing the needs for COVID19 infection control nursing of nursing college students It is used as the basic data for the development of simulation education programs by improving performance of both personal protection and collecting safety samples.

Cytotoxicity(MTT) evaluation of dental instruments made of polymers (치과용 폴리머 기구의 세포독성(MTT) 평가)

  • Choi, Eun-Mi
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.187-195
    • /
    • 2021
  • In order to assess the cell toxicity of 10 instruments made of polymers, the MTT assay which utilizes the L-929 cell was selected. Specimens were eluted at a temperature of 37℃ for 24 hours at a rate of 4g per 20mL, RPMI 1640, and then was positively and negatively contrasted with a control test solution, in accordance with the Notification No. 2020-12 Protocols of Medical Apparatus Biological Safety from the Ministry of Drug and Food Safety. As a result of 24 hours of incubation in 37℃, 5% CO2 Incubator and assessment using an ELISA reader, the results of Intraoral camera indiciated a cellular viability of more than 70% at a 50% eluate. But, the Plastic impression tray, 3D printing tweezer, Impression disposable syringe, Dental floss holder, Hand implant scaler, Surgical retractor, Oral scanner tip, Dental mirror, and the Water pick tip all reported a cellular viability of more than 70% at a 100% eluate, which indicates that do not exhibit cytotoxicity, thus allowing it to be used in contact with the mucous membrane of the oral cavity.

Effect of Multifaceted Interventions for Ward Nurses on the Storage, Conditions, and Transportation of Specimens for Microbial Culture (병동 간호사 대상의 다각적 중재가 배양검사 검체의 보관과 상태 및 운송에 미치는 영향)

  • Cho, Min Jung;Jeong, Jae Sim;Kim, Yoon Hee
    • Journal of Korean Biological Nursing Science
    • /
    • v.24 no.2
    • /
    • pp.95-103
    • /
    • 2022
  • Purpose: The purpose of this study was to provide multifaceted interventions for nurses and to confirm changes in their knowledge, perception, and actual practice on the adequate storage, conditions, and transportation of culture specimens. Methods: A one-group pretest-posttest experimental design was conducted with 41 nurses in two general wards of a tertiary acute care hospital in Seoul. Multifaceted interventions including education, feedback, posting guidelines and reminders, and improvement in specimen management accessibility were provided from May 2019 to January 2020. Outcomes were measured before and after the interventions. Knowledge and perception of the nurses were evaluated using self-reported questionnaires and actual practice by observation. Results: After the interventions, the average knowledge score on transportation time was significantly increased (Z= -4.89, p< .001). However, the knowledge score on storage methods was not significantly increased. The perception score was significantly increased (t= -3.19, p= .003). The proportion of specimen storage times, places, and conditions managed properly was significantly increased from 43.0% (46/107) to 77.1% (84/109) (p< .001). The average transportation time of blood samples to the laboratory significantly decreased from 3 hours 36 minutes (± 1 hour 52 minutes) to 3 hours 1 minute (± 1 hour 41 minutes) (t= 2.51, p= .013). The percentage of blood culture specimens arriving within 2 hours was increased significantly from 22.9% to 39.2% (χ2= 6.90, p= .009). Conclusion: The interventions were effective. However, some specimens remained in the ward longer than expected after the interventions. This requires further interventions.

Practical Understanding of Gross Examination Techniques (육안검사기술의 실무적 이해)

  • Woo-Hyun JI
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.1
    • /
    • pp.89-98
    • /
    • 2024
  • Gross examination techniques (GETs) of specimens collected from cancer surgery or endoscopy comprise the act of recording visual information about cancer for accurate histopathological diagnosis and collecting sections of the lesion to create microscopic specimens. GETs must include concise and accurate expressions, appropriate structuring, sufficient resections, error-free standardization of important information, and photo-diagramming of complex specimens. To increase the satisfaction of pathological interpretation, it is a task that must be performed accurately and carefully to gain confidence on a theoretical and practical basis with a sufficient understanding of gross examination. Based on the experience of clinical pathologists in the field of GETs, additional specimen types should be identified as viable candidates. Also, their needs and concerns regarding treatment should be carefully considered. In addition, departments at each institution should review the national focus on clinical partnerships, continuous professional training, diagnostic errors, and value-based healthcare provision.

Evaluation of an Automated Liquid-Handling System with Fixed Pipetting Tips in Radioimmunoassay (고정용 팁을 사용하는 Automated Liquid-Handling System의 RIA적용의 평가)

  • Shin, Sun-Young;Kim, Hee-Sun;Lee, Hyun-Ju;Jang, Hyun-Young;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.190-196
    • /
    • 2010
  • Purpose: This study was undertaken to investigate the feasibility of using automated liquid-handling systems equipped with reusable fixed tips in Radioimmunoassays and to demonstrate that the use of an automated pipetting instrument can decrease in the typical daily workload. Materials and Methods: The precisions of the automated pipettor and the manual pipettor were determined gravimetrically (n=30). A total of 30 specimens for HBs Ag were repeatedly pipetted (three replicates) with the automated pipettor and then retested. PSA samples were simultaneously pipetted with either the automated pipettor or the manual pipettor and then analyzed (n=40). Sample carryover test assessed for CA19-9, AFP and HCG when the automated pipettor was used. Pipetting speed of the automated pipettor and the manual pipettor were compared by evaluation of each workload. Results: The precisions coefficients of variation (CV) were 2.1% for the automated pipettor and 1.6% for manual pipettor. The mean cpm and CV for each group of replicates were 41,203 cpm and 3.7% for HBs Ag positive specimens, and 99 cpm and 7.9% for HBs Ag negative specimens, respectively. PSA results showed no significant differences between automated pipettor and manual pipettor (p=0.15, r=0.999). Carryover for CA19-9, AFP and HCG analytes was <0.1 ppm or below the assay limit of detection. Pipetting speed was significantly improved by using the automated instrument. Conclusion: There was no evidence that the use of an automated pipettor adversely affected any of the performance characteristics of the assay. Indeed, routine use of the Tecan automated pipettor has resulted in a decrease in the typical daily workload.

  • PDF

The Effects of Aprotinin Addition and Plastic Tube Usage for Glucagon Test Results (Glucagon 검사시 Aprotinin 첨가와 Plastic tube 사용이 미치는 영향)

  • Cho, Youn-Kyo;Choi, Sam-Kyu;Seo, So-Yeon;Shin, Yong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.117-120
    • /
    • 2011
  • Purpose: There are 3 warnings for Glucagon tests. First, EDTA tubes that already contain Aprotinin must be used for plasma collection. Second, for freezer storage of centrifuged plasma, glass tubes must be used. Last, glass tubes must be used for testing procedure. So we compared the glucagon results of next 3 situation to those of control group. First, We compared to results by tubes without Aprotinin and with aprotinin. Second, we compared to results by tubes(plastic vs glass) for plasma storage. Third, we compared to results by tubes(plastic vs glass) for testing. We tried to evaluate the results of the 3 different condition. Materials and Methods: 40 healthy adults were studied with normal results on the general medical check up and laboratory tests. We compared the results of 3 different condition belows: Blood were collected in EDTA tube containing aprotinin and plasma was stored in the glass tube for 3 days in a freezer and results were obtained by tests in the glass tubes. Results from EDTA plasma without aprotinin, results from platic tubes for freezer stroage, results from plastic tube when testing. Simple linear regression analysis and paired t-test using SPSS were done for statistical analysis. Commercial glucagon kit(RIA-method)which made by Siemens company were used. Results: Correlation coefficient between results of EDTA tubes with Aprotinin vs without Aprotinin was r=0.783 (p=0.064). Result of specimen in plastic tubes stored 3 days in a freezer showed lower value compared to those in glass tube(r=0.979, p=0.005). Also, results of testing in plastic tubes showed lower values than those testing in glass tubes. (r=0.754, p<0.001). Conclusion: It is recommended for glucagon determination to use EDTA tube with Aprotinin which is a inhibitor of protein breakdown enzyme. Results of plastic tube when storage and testing showed lower value than those of glass tubes, so it is recommended to store and test in glass tubes.

  • PDF

Quantitative Assessment of the Radiation Exposure during Pathologic Process in the Sentinel Iymph Node Biopsy using Radioactive Colloid (방사성 콜로이드를 이용한 감시림프절 생검 병리처리과정에서 방사선 피폭의 정량적 평가)

  • Song, Yoo-Sung;Lee, Jeong-Won;Lee, Ho-Young;Kim, Seok-Ki;Kang, Keon-Wook;Kook, Myeong-Cherl;Park, Weon-Seo;Lee, Geon-Kook;Hong, Eun-Kyung;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.309-316
    • /
    • 2007
  • Purpose: Sentinel lymph node biopsy became the standard procedure in early breast cancer surgery. Faculty members might be exposed to a trace amount of radiation. The aim of this study is to quantify the radiation exposure and verify the safety of the procedure and the facilities, especially during pathologic process. Materials and Methods: Sentinel lymph node biopsies with Tc-99m human serum albumin were performed as routine clinical work. Exposed radiation doses were measured in pathologic technologist, nuclear medicine technologist, and nuclear medicine physician using a thermoluminescence dosimeter (TLD) during one month. We also measured the residual radioactivities or absorbed dose rates, the exposure distance and time during procedure, the radiation dose of the waste and the ambient equivalent dose of the pathology laboratory. Results: Actual exposed doses were 0.21 and 0.85 (uSv/study) for the whole body and hand of pathology technologist after 47 sentinel node pathologic preparations were performed. Whole body exposed doses of nuclear medicine physician and technologist were 0.2 and 2.3 (uSv/study). According to this data and the exposure threshold of the general population (1 mSv), at least 1100 studies were allowed in pathology technologist. The calculated exposed dose rates (${\mu}$ Sv/study) from residual radioactivities data were 2.47/ 22.4 ${\mu}$ Sv (whole body/hand) for the surgeon; 0.22/ 0 ${\mu}$ Sv for operation nurse. The ambient equivalent dose of the pathology laboratory was 0.02-0.03 mR/hr. The radiation dose of the waste was less than 100 Bq/g and nearly was not detected. Conclusion: Pathologic procedure relating sentinel lymph node biopsy using radioactive colloid is safe in terms of the radiation safety.(Nucl Med Mol Imaging 2007;41(4);309-316)

Molecular Epidemiology of Human Astrovirus Infection in Hospitalized Children with Acute Gastroenteritis (급성 위장관염으로 입원한 소아에서 분자 유전학적 방법에 의한 Human Astrovirus 감염의 유병률)

  • Chung, Ju-Young;Huh, Kyung;Kim, Sang Woo;Shin, Bo Mun;Han, Tae Hee;Lee, Jae In;Song, Mi-Ok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.2
    • /
    • pp.139-146
    • /
    • 2006
  • Purpose: Human astrovirus (HAstV) is known to be an important etiologic agent of acute gastroenteritis in infants worldwide. However, the prevalence of HAstV infection varies according to geographic region and patient age. The purpose of our study was to investigate the incidence of HAstV infection among hospitalized children at a tertiary hospital in Seoul. Methods: Fecal samples were collected from hospitalized children up to five years of age with acute gastroenteritis. A total of 812 fecal samples were collected from hospitalized children with acute gastroenteritis between February 2004 and January 2005. Fecal specimens were screened for rotavirus, enteric adenovirus and norovirus by enzyme immunoassay (EIA) or reverse transcriptase polymerase chain reaction (RT-PCR). HAstV positive samples were characterized by RT-PCR. Results: Rotavirus was detected in 16.9% (138/812), norovirus in 11.6% (94/812), and adenovirus in 4.0% (33/812) of the study population. HAstV was detected in 4.0% (33/812) samples by RT-PCR. The age distribution of HAstV positive patients was as follows: <12 month old, 82.0% (27/33); 1~2 years old, 6.0% (2/33); 2~5 years old, 12.0% (4/33). The seasonal distribution of HAstV positive samples was as follows; April (3), May (5), June (4), August (12), September (4), October (2), November (2), and December (1). The peak rate of HAstV infection was observed during the summer season, 2004. A mixed infection of viral agents was confirmed in 2.7% (22 /812) of the study population, most commonly with rotavirus and norovirus, and with rotavirus and HAstV. Genotype 1 was the predominant type (91%, 20/22) and genotype 8 was detected in two cases. Conclusion: The prevalence of HAstV infection was 4.0% in hospitalized children with acute gastroenteritis, and was especially high in infants. HAstV can be considered as an important etiologic agent of gastroenteritis in children.

  • PDF