Effect of EEG Wave Type on Visual Cortex of Visual Target according to Position of Fixation Point (주시점의 위치에 따른 시 표적이 시피질의 뇌파에 미치는 영향)

  • Kim, Douk-Hoon;Cho, Jin-Wook;Nam, Sang-He
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.101-105
    • /
    • 2000
  • This study was to investigate the effect of EEG wave type on visual cortex of visual target according to position of fixation point on the Korean. Visual evoked potential system used the BIO-Pag and recorded to 586 computer. The illumination was 500 lux and the visual target was red light dot of 3 cm size. The results of the convergence and divergence as follows: The visual stimulation waves on the visual cortex have about 70% of delta wave, about 10% of beta wave, about 9% of theta wave and about 7% of alpha wave respectively. The convergence state was much more appeared the fast wave on the comparative of the divergence. Therefore, the convergence state was much more producted the beta and alpha wave on the comparative of the divergence. On the other hand, on the convergence and divergence, the histogram amplitude of EEG wave appeared almost the non-Gaussian shape. According to the phase analysis of amplitude of EEG wave almost all type was linear shape.

  • PDF

Development of IEC 61850 Client Testing System for Verifying the Communication Conformance of Substation Automation (변전자동화 통신 적합성 검증을 위한 클라이언트 IEC 61850 시험시스템 개발)

  • Lee, Nam-Ho;Jang, Byung-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.169-176
    • /
    • 2010
  • Substation Automation System is basically operating throughout communicative services among IEC 61850 based devices. So, minimum requirement in order to install the system in the substation is to verify server and client conformance of IEDs and HMIs according to the IEC 61850 standard. Even though UCA IUG issued IEC 61850 conformance test procedures for both the server and the client, Much of the test is limited to IEDs as server and there is no client-only testing tool except KEMA server test tool sets. this study aims to develop IEC 61850 client testing system for verifying the full communication conformance of the substation automation system and this paper describes the design and implementation of the testing system.

Actual Analysis and Solution of Aquatic Leisure Activity Safety Accident Around Coast (연안역 수상레저활동 안전사고 실태분석 및 개선방안)

  • Jeong Jong-Seok
    • Journal of Navigation and Port Research
    • /
    • v.30 no.3 s.109
    • /
    • pp.247-251
    • /
    • 2006
  • By becoming 21st century which run be charactered as highly industrialized society which spreads diversification and individualization, there have been elevation of income level and increase of time for leisure activity by introducing 5 working days system. And this brings out increasing of aquatic leisure activity population and the contents of the leisure becomes very active. Static indoor activity which was the main current of the leisure activity in the past, however, it is now called for outdoor activity accompanied by the society growth and even expands towards that people get into action and experience by their own free will. With this point of view, the aquatic leisure run become a safe activity. But with a rapid growth of aquatic leisure activity, safety concerns become a serious problem. To prevent safety accident, training should be given, safety inspection and registration should be requested, and strong support of system is needed so users can have an insurance for safety accident. These complements are necessary for overall nourishment and management measure to charge in systematical safety for the users.

Low Temperature Fluidity Performance Evaluation of Composited Package Fuel Heater for Diesel Cars (디젤차량용 통합연료히터의 저온유동성 성능평가)

  • Lee, Jeong-Hwa;Park, Hyung-Won;Lee, Woong-Su;Lee, Young-Jea;Lee, Bo-Hee;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.152-158
    • /
    • 2014
  • It is very important to supply the diesel fuel from fuel tank to combustion chamber in case of cold start procedure. the paraffin hydrocarbons are easily solidified at low fuel temperature and it can be blocking the fuel supply to the high pressure fuel pump. In order to reduce the fuel crystallization (Waxing), it have been used to develop not only cold flow additives but also the proper mounting design of fuel filter. Block heater in the fuel filter assembly have been also contained to improve the cold start and prevent blocking the fuel supply in Common Rail Direct Injection System. we can obtain the fuel pressure drop and fuel flow rate, power consumption of fuel heater to have the cold flow evaluation test with the saperated and composited fuel heater at the low ambient temperature, Due to evaluating cold flow performance of two block heater, we knew that composited package fuel heater was the excellent cold flow performance compared to separated type and obtained the parameters of cold flow.

Intercomparison of the KAERI Reference Photon and Beta Radiation Measurements (한국원자력연구소 기준 광자 및 베타선장 측정의 국제상호비교)

  • Chang, Si-Yeong;Kim, Bong-Hwan;Kim, Jang-Lyul;McDonald, J.C.;Murphy, M.K.
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.255-262
    • /
    • 1996
  • This paper describes the results of intercomparison measurements of KAERI reference photon and beta radiation fields between the KAERI and the PNNL(Pacific Northwest National Laboratory), recently performed at KAERI radiation calibration and dosimetry laboratory on the basis of the ANSI N13.11 criteria for personal dosimeter performance test. Each laboratory used her own radiation detectors or measurement devices traceable to her national primary standard in measuring the exposure rates for photon fields, the absorbed dose rates for beta radiation fields. The agreements in reference radiation measurements between two laboratories were found to be less than ${\pm}2.0%$ for photon fields, ${\pm}1.0%$ for beta radiation fields. Therefore, it could be concluded that KAERI reference radiation fields comply well with the international standard and thus can further serve as a national basis for the researches and developments in radiation protection dosimetry in Korea.

  • PDF

Design of data integration model between hospitals for healthcare information collection (헬스케어 정보 수집을 위한 병원간 데이터 통합 모델 설계)

  • Jeong, Yoon-Su;Han, Kun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.6
    • /
    • pp.1-7
    • /
    • 2018
  • As IT technology develops recently, medical equipment used in hospitals is demanding high performance. However, since the user visits different hospitals depending on the user's situation, the medical information treated at the hospital is distributed among the hospitals. In this paper, we propose a model to efficiently integrate the health care information of the users stored in the hospital in order to collect the healthcare information of the users who visited the different hospitals. The proposed model synchronizes users' healthcare information collected from personal wearable devices to collect user - centered healthcare information. In addition, the proposed model performs integrity and validity check related to user's healthcare information in a database existing in a cloud environment in order to smoothly share data with the healthcare service center. In particular, the proposed model enables tree - based data processing to smoothly manage healthcare information collected from mobile platforms.

Data De-duplication and Recycling Technique in SSD-based Storage System for Increasing De-duplication Rate and I/O Performance (SSD 기반 스토리지 시스템에서 중복률과 입출력 성능 향상을 위한 데이터 중복제거 및 재활용 기법)

  • Kim, Ju-Kyeong;Lee, Seung-Kyu;Kim, Deok-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.149-155
    • /
    • 2012
  • SSD is a storage device of having high-performance controller and cache buffer and consists of many NAND flash memories. Because NAND flash memory does not support in-place update, valid pages are invalidated when update and erase operations are issued in file system and then invalid pages are completely deleted via garbage collection. However, garbage collection performs many erase operations of long latency and then it reduces I/O performance and increases wear leveling in SSD. In this paper, we propose a new method of de-duplicating valid data and recycling invalid data. The method de-duplicates valid data and then recycles invalid data so that it improves de-duplication ratio. Due to reducing number of writes and garbage collection, the method could increase I/O performance and decrease wear leveling in SSD. Experimental result shows that it can reduce maximum 20% number of garbage collections and 9% I/O latency than those of general case.

Calculation Method of Entrance Skin Dose in X-ray Beam Quality Factor (선질계수에 의한 피부입사선량 계산법)

  • Kim, Sung-Chul;Kim, Chong-Yeal;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.258-267
    • /
    • 2010
  • This interest in radiation exposure makes increasing doctor's awareness and knowledge of radiation dose in patients during X-ray test important in reducing patient's uneasiness. However, very few facilities are equipped with measurement instruments. Therefore, an intensive study to find out patient dose using computational method has been initiated. This study used special features of the bit system and NDD-M and directly measured the output dose of diagnostic X-ray instruments used in Korea to create tables. Two different methods were found to be adequate when applied to cases when X-ray outputs were both known and unknown, and comparative experiments with real measurement doses were carried out. Presented methods were found to provide more accurate results compared to the bit system and NDD-M. Therefore, patient dose during clinical trials were found to be more easily acceptable to medical personnel in the radiation field in terms of radiation exposure and reduction of medical X ray dose.

Study on Performance Improvement Air Cooled Condenser Considering Ambient Condition (대기 조건에 따른 공랭식 응축기 성능 저하 개선 연구)

  • Cha, Hun;Ryu, Gwang-Nyeon;Kim, Jung-Rae
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.3
    • /
    • pp.201-207
    • /
    • 2015
  • Air cooled condenser for power plant is used at inland area of desert or mountainous area because condenser coolant like sea water is not necessary. However, the performance of air cooled condenser is influenced by ambient condition such as wind speed and air temperature. Therefore, various devices have been designed to improve the performance of air cooled condenser. In this study, the CFD analysis for air cooled condenser was carried out according to wind speed and wind screen configuration. As wind speed increased from 3m/s to 7m/s, the fan flow rate was reduced about 15.76% and the rise of inlet air temperature was 5.55 degree of Celsius. When the suitable wind screen is equipped, the fan flow rate went up about 5.18% and inlet air temperature dropped by 2.08 degree of Celsius in comparison with original case without wind screen at 7m/s wind speed.

Autofocus of Infinity-Corrected Optical Microscopes by Confocal Principle and Fiber Source Modulation Technique (공초점 원리와 광섬유 광원 변조를 이용한 무한보정 현미경 자동초점)

  • Park, Jung-Jae;Kim, Seung-Woo;Lee, Ho-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.583-590
    • /
    • 2004
  • The autofocus is one of the important processes in the automated vision inspection or measurements using optical microscopes, because it influences the measuring accuracy. In this paper, we used the confocal microscope configuration based on not a pinhole but a single-mode optical fiber. A single mode fiber has the functions of source and detector by applying the reciprocal scheme. As a result, we acquired a simple system configuration and easy alignment of the optical axis. Also, we embodied a fast autofocus system by acquiring the focus error signal through a source modulation technique. The source modulation technique can effectively reduce physical disturbances compared with objective lens modulation, and it is easily applicable to general optical microscopes. The focus error signal was measured with respect to the modulation amplitude, reflectance of the specimen and inclination angle of the measuring surface. The performance of the proposed autofocus system was verified through autofocusing flat mirror surface. In addition, we confirmed that source modulation rarely degrades the depth resolution by the comparison between the FWHMs of axial response curves.