• 제목/요약/키워드: 건축물 에너지성능평가

검색결과 83건 처리시간 0.025초

원형개구부가 있는 강판 전단벽 시스템을 적용한 학교 건축물의 내진성능평가 (Seismic Performance Evaluation of School Building Reinforced by Circular-Opening Steel Shear Wall System)

  • 이유현;이수헌;이희두;신경재
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.19-26
    • /
    • 2018
  • After the Gyeongju earthquake, school buildings were designated as earthquake shelters. However, the ratio of designed for seismic of domestic school buildings is only 23.2% in Korea, and it is necessary to secure the seismic safety of those. Therefore, in this paper, a target building was selected before the seismic design criteria was established and the seismic performance of the building was evaluated. After the evaluation, reinforcement of the building was carried out using seismic retrofit systems which was previously tested. For this purpose, the evaluation was carried out using OpenSees program and the reliability of the seismic retrofit systems was also verified. In this way, we can more precisely reproduce the response of the building in case of actual earthquake and predict damage of the earthquake in the future.

건축구조물의 내진성능 향상을 위한 강재댐퍼 형상 및 이력 거동 (Metallic Damper Shape and Cyclic Behavior for the Seismic Capacity Improvement of Building Structures)

  • 이현호;김세일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권3호
    • /
    • pp.123-130
    • /
    • 2010
  • 본 논문에서는 기존 건축물의 내진성능을 향상시키기 위해 시공성과 설치 비용적인 측면에서 상대적으로 우수한 강재댐퍼를 대상으로 기존 개발된 장치와 새로 개발된 형상의 장치에 대한 평가를 해석적으로 수행하였다. 해석결과는 강도 및 에너지 소산능력으로 평가하였으며, 제안된 내력 산정식의 적용을 아울러 평가하였다. 연구대상 댐퍼의 스트럿 형상은 V형, S형이며, 댐퍼의 스트럿 높이와 각도를 주요 변수로 한 후 ABAQUS를 이용하여 유한요소 해석하였다. 해석은 최대변위를 50mm로 하고 점진적인 이력변위곡선을 적용하여 수행하였다. 항복강도, 최대강도, 에너지 소산능력 평가결과, V형 및 S형 모두 우수한 성능을 보유한 것으로 평가되었으며, 또한 스트럿 각도 $60^{\circ}$ 및 높이 140, 200 mm의 성능이 안정적인 것으로 평가되었다. 전체적으로는 S형의 응답이 V형보다 안정적인 것으로 평가되어, S형 강재댐퍼의 적용성이 V형보다 유리한 것으로 평가되었다.

저에너지건물 통합설계 인센티브 체계 비교 연구 (The Comparative Study on Incentive System for Integrated Design of Low-Energy Buildings)

  • 이병연
    • 한국산학기술학회논문지
    • /
    • 제17권6호
    • /
    • pp.129-139
    • /
    • 2016
  • 본 논문은 저에너지 건축물 보급을 활성화하기 위하여 시행되고 있는 국내외 인센티브 제도를 비교분석하고 이를 통하여 국내 저에너지 건축물 인센티브 제도의 개선을 모색하기 위한 목적으로 한국, 캐나다, 미국, 싱가폴의 국가단위, 지방정부단위 제도를 분석 대상으로 하였다. 인센티브 제도의 체계는 1) 인센티브 종류 및 수혜자의 규정, 2)성능기준 및 평가방식의 정립, 3) 통합설계지원, 4) 재원의 확보를 근간으로 구성된다. 한국을 제외한 모든 국가들이 통합설계에 참여하는 전문가에 대한 인센티브 제도를 도입하고 있으며, 신축 중심 인센티브가 리모델링 건축물을 포함하는 방향으로 전환되고 있다. 인센티브 제도의 근간인 성능기준은 각 프로그램이 속한 국가 또는 지방정부가 규정하는 통합에너지성능분석기준에 따라 통합성능에 따른 지원이 주를 이루고 있으며, 개별 기술에 대한 지원을 보완하여 지원 범위 확대 경향을 보이고 있다. 통합 성능의 경우에도 초기 시뮬레이션에 의한 검증에서 실제 에너지사용량에 의한 검증으로 전환되어 시공품질 및 건물운영에 점차적으로 비중을 강화하고 있다. 통합 디자인 자체에 대한 지원과 자료 데이터베이스를 운영하여 성능기반 건축물 시장으로의 빠른 재편과 신산업 육성을 기대하고 있다. 안정적인 제도 운영을 위하여 재원확보가 필수적인데, 세금이 가장 일반적이고, 에너지 사업자 지원 또는 에너지 사용량에 따른 누진제를 통해 재원을 확보하는 보다 적극적인 재원확보 방안도 제시되고 있다.

플로팅 건축에서 해수열 이용을 위한 수중 열교환기의 봄철 성능평가 (Performance Evaluation of Sea Water Heat Exchanger in the Springtime for Floating Architecture)

  • 황광일;김별;이현인;김익현;도근영
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2012년도 춘계학술대회
    • /
    • pp.442-443
    • /
    • 2012
  • 지구환경문제에 대응하기 위한 탄소배출량 저감 기술 개발과 같은 대응기술 개발이 시급한 가운데 수 해양공간에 대한 수요의 증가로 플로팅 건축물에 대한 관심 또한 증가하고 있다. 이에 본 연구에서는 플로팅 건축물 주변에 존재하는 신재생에너지 중 해수 열 이용을 위한 수중 열교환기를 기초연구를 바탕으로 제작하고 실험을 통하여 성능을 평가하였다.

  • PDF

학교시설의 녹색건축 활성화를 위한 인증현황 분석 연구 - 경기도 학교시설을 중심으로 - (An Analysis on Current Status of Certification for Green Building Revitalization in School - Focused on the School Located in Gyeonggi-do Province -)

  • 김장영;김성중;이승민
    • 교육녹색환경연구
    • /
    • 제14권3호
    • /
    • pp.9-17
    • /
    • 2015
  • 본 논문에서는 경기지역을 대상으로 학교시설의 녹색건축 활성화를 위한 검증 기준인 녹색건축인증, 건축물 에너지효율등급, 에너지절약계획에 대한 항목별 적용 여부 및 계획수준을 분석하였다. 분석결과 녹색건축인증은 항목 채택 시 추가 비용이 들어가는 항목 및 유지관리가 어려운 항목은 채택비율이 낮은 것으로 분석되었다. 또한, 에너지효율등급은 학교시설 특성상 비교적 단순한 형태와 일정한 규모로 계획되고 고효율기자재 사용비율이 높아 다른 용도의 건축물에 비해 높은 등급을 보였다. 그리고 에너지성능지표(EPI)의 경우 지역별로 부문별 취득 점수에 차이가 있는 것으로 분석되었다. 특히, 경기지역의 경우 타 부문 대비 건축부문에 대한 적용점수가 낮은 것으로 나타나 단열성능 강화 시 보다 높은 점수를 취득할 수 있을 것으로 사료된다. 3가지 기준에 대한 분석결과, 다수의 시설이 학교가 취득해야 하는 의무 획득 기준에만 맞춘 형식적인 계획으로 인해 건물별 특성을 고려하지 않고 기존 획득 항목에만 맞춰 최소한의 기준만 만족하여 계획하는 패턴을 보였다. 그러나 학교시설은 녹색건축물의 확대라는 목표와 더불어 학생들의 녹색교육을 위한 토대가 되어야 하는 의무를 지닌 상징적인 건축물이다. 따라서 시설의 특성을 파악하고 건축물을 기획하는 단계부터 다양하고 합리적인 평가항목 적용이 이루어지도록 고려한 계획이 필요할 것으로 판단된다.

로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구 (A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing)

  • 이나은;안병립;장철용;이승복
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.

플로팅 건축에서 해수열 이용을 위한 수중 열교환기 모델 개발과 성능 평가 (Performance evaluation of types of sea water heat exchanger for floating architecture)

  • 김별;이창훈;구재혁;황광일
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2013년도 추계학술대회
    • /
    • pp.287-288
    • /
    • 2013
  • 삼면이 바다인 우리나라에서는 지구 온난화에 따른 해수면 상승과 같은 환경 문제 와 국민소득 증가에 따른 해양공간에 대한 수요의 증가로 플로팅 건축물의 발전 가능성이 크다. 하지만 아직까지 플로팅건축물 주변에 존재하는 해수열에너지를 이용을 위한 수중 열교환기에 대한 기초 연구가 부족하다. 이에 본 연구에서는 플로팅 건축물에서 해수 열 이용을 위한 수중 열교환기 모델 개발 및 실험을 통하여 성능을 평가하였다.

  • PDF

주상복합 건축물에 적용된 지열이용 히트펌프 시스템의 냉방성능 평가 (Evaluation on the Cooling Performance of Geothermal-energy Using Heat Pump System in Mixed-use Residential Building)

  • 김용식;김중헌;황광일
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.9-16
    • /
    • 2006
  • Geothermal-energy has been getting popular as a natural energy source for green buildings these days. Public building with gross area more than $3000m^2$, planned after March, 2005, should spend about 5% of total building cost for equipment run by natural energy source (e.g. geothermal, solar heat, solar power, etc) according to renewable energy promotion law in Korea. As a result geothermal-energy using heat pump system is emerging as a effective alternative for realistic and economic plan although design guidelines and construction code for the system is in progress and technical data is far from sufficient. The quantitative analysis on the performance of geothermal-energy using heat pump system is insufficient for appropriate design of it. In this paper, cooling performance of geothermal-energy using heat pump system of residential and retail etc. mixed-use building has been analyzed on the basis of temperature comparison between inlet and outlet of heat exchangers of the operating system. Additionally, dry-bulb temperature and relative humidity have been measured and analyzed together as an index of indoor thermal environment.

에너지성능지표(EPI)를 대상으로 한 개방형BIM기반 건축인허가 개선방향 제시 (Improvement of Open BIM-based Building Permission Process Using EPI(Energy Performance Index))

  • 김인한;김민찬;최중식
    • 한국건설관리학회논문집
    • /
    • 제16권6호
    • /
    • pp.124-135
    • /
    • 2015
  • 세계적으로 환경오염문제가 대두되면서 국내에서도 정부와 민간차원에서 친환경건축을 위한 노력이 활발히 진행 중이다. 하지만 건축물의 친환경 성능 및 친환경 관련 법규 및 기준 등에 대한 평가환경은 2차원기반의 수작업을 통한 평가로 진행되기 때문에 시간, 비용, 노동력 등이 많이 소요되며 평가의 정확성 및 효율성을 확보하기 어렵다. 따라서 본 논문에서는 개방형BIM기반으로 친환경건축 관련 인허가 업무의 개선을 목적으로 친환경건축 관련 인허가 조건 중 에너지성능지표 평가항목과 IFC포맷의 데이터와 연계를 통한 평가방안 모색하고 발생하는 문제점에 대한 대안을 제시하며 이를 반영한 평가프로그램의 활용으로 평가 프로세스를 제시함으로써 개방형BIM기반으로 에너지성능지표의 평가를 자동화하는 방안을 제시한다. 본 연구에서 제시된 방안을 친환경건축 관련 인허가 업무에 적용함으로써 업무절차의 간소화와 자동화를 통한 시간, 비용, 노동력의 절감을 기대할 수 있으며 설계변경 시 요구되는 절차가 단순화되어 업무의 생산성과 효율성이 향상되며 검토과정과 결과 값의 투명성과 검토의 정확성과 신뢰도를 확보 할 수 있을 것으로 기대한다.

공동주택 친환경인증단지의 에너지성능지표 비교분석 연구 (The Analysis on Energy Performance Index of the Green Building Certified Apartment Buildings in Korea)

  • 김종엽;정윤혜;백혜선
    • 토지주택연구
    • /
    • 제4권4호
    • /
    • pp.407-415
    • /
    • 2013
  • 2002년에 친환경건축물인증제도가 시행된 이후 많은 인증 수행에도 불구하고 이 제도의 효과분석이나 개선방안 노력이 저조하다. 특히 인증제도에서 에너지성능은 에너지절약설계기준에 있는 에너지성능지표(EPI)로 평가되지만 지금까지 지표에 대한 현황분석이 미비하여 개선에 어려움이 있다. 본 연구에서는 친환경 공동주택 인증단지를 대상으로 에너지성능지표간의 상관관계를 살펴보고 에너지성능지표의 각 부문별 에너지 기본 배점에 따른 점수 현황을 분석하여 지표 개선을 도모하였다. 친환경 공동주택 인증단지의 EPI 평균득점은 약 74.68점, 최소 63.40점, 최대 90점으로 편차가 큰 것으로 나타났다. 또한 인증지표 중에서 최고의 배점으로 편성된 에너지소비량의 경우, 최대 12점 배점에서 평균 7.04점으로 평균 수준에 머물고 있었다. 향후 에너지소비량 인증지표에서 등급구간의 강화 또는 산출식의 조정 등의 지표 개선이 필요하였다.