• Title/Summary/Keyword: 건물 에너지 절감

Search Result 206, Processing Time 0.027 seconds

Indoor Air Temperature Distribution in a Floor Heating Space with PCM Panels (잠열저장패널이용 바닥난방공간의 실내온도분포에 관한 연구)

  • Cho, Soo;Sohn, Jang-Yeul
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.59-71
    • /
    • 1992
  • The purposes of the present study are to investigate the characteristics of heat storage and emission of the PCM($CalCl_2{\cdot}6H_2O$) panel, and to analyze the distribution of indoor air temperature in a floor heating space with PCM panels for the heating system. Two identical unit test cells sized $1.8m^W{\times}1.8m^L{\times}1.8m^H$ were built and installed with specially designed aluminium Ondol-panels. It held 1.2kg of calcium chloride hexahydrate(CCH). It was found that PCM panels could reduce the indoor air temperature fluctuations and maintain the phase changing temperature for considerably long duration, $2{\sim}3$ times longer in heating hour over no-CCH one. When the elapsed time was 6 hours, the average temperature difference between PCM panel and Ondol panel was $7.7^{\circ}C$.

  • PDF

Implementation of Electricity Management System based on the Wireless ICT (무선 ICT기반의 전력관리시스템 구현)

  • Kim, Min-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.123-129
    • /
    • 2014
  • This paper suggests that it provides a electricity management system for wasting electricity, from power demand growth environments. This Energy management system based on ICT(Information & Communication Technology) can control Smart Power Outlet connecting to this system with Web Browser and Android phone, anytime, anywhere. Through analysis of acquisition data from them, this proposed system can monitor and control power consumption efficiently. This system was organized mesh network of Smart Power Outlet, gateway by wireless Zigbee, and ESS(Energy Saving System) by TCP/IP beyond existing limit of communication distance and space.

A Study on lighting Energy Conservation in a Small Office Space with Daylight Dimming Control System (소규모 사무공간에서 디밍제어를 이용한 조명에너지 절약에 관한 연구)

  • 김한성;김강수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.15-21
    • /
    • 2003
  • This paper presents field measurements on daylighting and electric lighting with dimming controlled systems for a small office in Seoul, Korea. And the main purpose of this study is to provide the evaluation data of lighting energy performance when a dimming system is installed. For the performance evaluation, the mock-up room(3.6x7.2x2.6[m]) was used for the actual test. The results of this study were as follows; 1) The correlation between daylight illuminance at a workplane(Ed) and the photosensor signal(Sd) was an important factor affecting the performance of daylight responsive dimming system, 2) The mock-up office space gained a sufficient workplace illuminance of 579[lux] with the dimming control system 3) About 53[%J of monthly lighting energy could be saved using the dimming control system.

Ag/Ta/glass 다층박막의 Ta seeding이 전기적 광학적 특성에 미치는 효과

  • Park, Seon-Ho;Jo, Hyeon-Cheol;Lee, Gi-Seon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.69-69
    • /
    • 2010
  • 현대 건축물에서 건물에너지의 손실은 대부분은 창호를 통하여 유출되어지고 있으며 에너지 절감을 위해서는 창호의 단열성을 향상시켜야한다. 저방사(Low Emissivity) 코팅유리는 건축물의 냉난방비용을 절약할 수 있는 대표적인 건축재료로써 외부에서 유입되는 태양광의 가시광선 영역은 높은 투과율을 가지면서 적외선 영역과 겨울철 실내 난방열을 반사하는 특징을 지니는 박막코팅기술이다. 이 코팅유리는 일반적으로 유전체/금속/유전체 다층박막 구조로 되어있으며, 유전체층은 내구성 증진과 금속층의 반사를 낮추어 투과율이 향상된다. 금속층은 적외선영역의 복사에너지를 반사하는 역할을 하며 전도성이 우수한 Ag 또는 Au, Pt 등을 이용하고 있다. Ag의 경우 산화물기판 위에 증착하였을 경우 island 성장을 하고 이들의 합체는 전기적, 광학적 특성에 큰 영향을 미치게 된다. 본 연구에서는 DC-sputtering법으로 제조된 Ag/glass, Ag/Ta/glass 박막을 제조하고 Ta seeding이 Ag의 전기적, 광학적 성질에 미치는 영향을 관찰하였다. 박막의 표면 미세구조는 FE-SEM(Field Emission Scanning Electron Microscope)과 AFM(Atomic Force Microscope)으로, 표면저항은 4 point probe로 분석하였다. 광투과율은 UV-Vis spectroscopy와 FT-IR로 측정하였으며 측정파장범위는 각각 200~1100nm와 1400~2400nm 이다.

  • PDF

A Comparative Study on Heating Energy Consumption for Apartment Based on the Annually Strengthened Criteria of Insulation (공동주택 연도별 단열기준 강화에 따른 에너지소요량 비교 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.83-89
    • /
    • 2013
  • Energy consumption is closely related to our lives. As Korea has four seasons, heating and cooling system is considered as essential facilities for the residential buildings. Accordingly, the government has continuously strengthened the design criteria to improve energy for new and existing building to save energy. The most important factor in the energy efficiency analysis for apartment is the heat transmission coefficient, and the value is significantly different as the heating energy amount is greatly different according to the window area ratio versus facade area ratio. Therefore, it is time to conduct continuous set-up for goal to enhance efficiency and restriction on window area ratio versus facade area ratio.

Recommended Practice for a Reasonable Design Demand Factor and Analysis of Power Consumption Characteristics by loads in Hospitals (병원용 건물의 부하종별 전력소비특성 분석 및 수용률 기준 정립에 관한 연구)

  • Yoo, Sang-Bong;Kim, Se-Dong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.77-84
    • /
    • 2007
  • It is increased electrical energy consumption with the development of intelligence society in hospitals and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in hospitals, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 32 hospitals and 9 electrical design offices. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried the linear and nonlinear regression analysis.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (기존 노후건축물의 최적 리모델링 개선안 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Oh, Se Min
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.207-216
    • /
    • 2014
  • The energy loss can be divided into the loss caused by heat transfer and the loss caused by air flow. Heat transfer is the loss resulting from the heat transmittance of external wall, roof, and floor, and represents one of the most vulnerable elements of existing buildings. To prevent such loss, it is necessary to increase the mean heat transmittance of entire external wall, including the window, to a level above the standard regional value and ensure the air-tightness of window. The old buildings have the structure which is prone to the loss of greater air flow due to the air infiltration through the exit/entrance door upward along the stairway by the stack effect and simultaneous suction of air from each floor, and becomes even vulnerable to the loss of heat insulation for each floor, although the external wall and windows are the most vulnerable parts. The improvement plans for each floor need to be submitted in tandem with the diagnosis of whole building, regarding the diagnosis plan and energy improvement measures based on the survey of site, rather than adhering to the misconception that the replacement of window alone will result in energy-savings.

OSGi Based Context-Awareness Smart Building Management System (OSGi 기반 상황인지 스마트 빌딩 관리 시스템)

  • Lee, Se-Hoon;Lee, Sang-yeob;Kim, Jong-chul;Baek, Yong-Tae
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.07a
    • /
    • pp.137-138
    • /
    • 2016
  • 본 논문에서는 고유가와 기후변화의 시대인 21세기에 따라 에너지 사용량, 시설관리 비용을 절감하고자 OSGi기반 플랫폼인 openHAB을 이용 상황인지 자동화 건물관리 시스템을 개발하고자 한다. 개인화 디바이스에서 사무실 제어 할 수 있으며 상황에 따라 사물들을 자동화 제어 한다.

  • PDF

Influence of indoor pollution in habitants′ health and development of the model of healthy home environment (실내 환경오염이 거주자의 건강에 미치는 영향 평가 및 예방모델개발)

  • 신동천;양지연;임영욱;김호현;박성은;홍천수
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.69-70
    • /
    • 2003
  • 현대인은 실외에서 활동하는 시간보다 실내에서 거주하는 시간(80%)이 더 많고, 그로 인해 실외 대기오염보다 실내 공기 오염이 일반인의 건강에 미치는 영향이 더 큰 것으로 보고되고 있다. 국내에서도 1990년대 이후 실내에서의 일일 노출시간 증가, 한정된 공간에서의 오염된 공기의 지속적 순환, 에너지 절감 시스템에 의한 건물의 밀폐화에 따른 오염농도의 누적현상, 다양한 건축자재 및 생활 인테리어 용품의 사용으로 인한 실내 오염원의 존재 등으로 실내 공기질 악화에 따른 건강 영향에 대해 관심이 고조되기 시작하였다. (중략)

  • PDF

Indoor Temperature Estimation System for Reduction of Building Energy Consumption (건물 에너지 절감을 위한 실내 온도 추정 시스템)

  • Kim, Jeong-Hoon;You, Sung Hyun;Lee, Sang Su;Kim, Kwan-Soo;Ahn, Choon-Ki
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.885-888
    • /
    • 2017
  • In this paper, a new strategy for estimating building temperature based on the modified resistance capacitance (R - C) network thermal dynamic model is proposed. The proposed method gives accurate indoor temperature estimation using minimum variance finite impulse response filter. Our study is clarified by the experimental validation of the proposed indoor temperature estimation method. This experiment scenario environment is composed of a demand response (DR) server and home energy management system (HEMS) in a test bed.