• Title/Summary/Keyword: 거친 표면

Search Result 336, Processing Time 0.029 seconds

알루미늄 압출 진공용기의 표면 거칠기 비교

  • Gwon, Hyeok-Chae;Hong, Man-Su;Ha, Tae-Gyun;Park, Jong-Do
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.228-228
    • /
    • 2012
  • 방사광 가속기의 좁은 간격 언듈레이터 진공용기를 지나는 전자의 진행을 방해하는 wakefield 효과를 최소화하기 위해서는, 진공용기의 내부 표면이 매끄럽게 제작되어야 한다. 알루미늄 진공용기의 일반 압출 직후 내부 표면 거칠기는 이러한 요구 조건을 만족하지 못하며, 다양한 표면처리를 통하여 원하는 표면 조도를 얻을 수 있다. 여기서는 일반 압출 공정만 거친 시료와 압출 이후 표면처리를 거친 시료의 내부 표면 조도를 비교하였다.

  • PDF

Numerical Computation of Radar Scattering Coefficient for Randomly Rough Dielectric Surfaces (불규칙적으로 거친 유전체 표면에서의 레이더 산란계수 수치해석적 계산)

  • 차형준;오이석
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.1
    • /
    • pp.65-72
    • /
    • 2000
  • Scattering coefficients of randomly rough lossy dielectric surfaces were computed by using the FDTD(Finite-Difference Time-Domain) method and the Monte Carlo method in this paper. The FDTD method was applied to compute electromagnetic wave scattering characteristics at any incident angles, any linear polarizations by dividing the computation region into the total-field region and the scattered-field region. The radar cross sections(RCS) of conducting cylinders have been computed and compared with theoretical results, measurement data and the results from the method of moment(MoM) to verify the FDTD algorithm. Then, to apply the algorithm to compute scattering coefficients of distributed targets, a two-dimensionally rough surface was generated numerically for given roughness characteristics. The far-zone scattered fields of 50 statistically independent dielectric rough surfaces were computed and the scattering coefficient of the surface was calculated from the scattered fields by using the Monte Carlo method. It was found that these scattering coefficients agree well with the SPM(Small Pertubation Method) model in its validity region.

A Study on Friction and Wear of Foam Rubbers (발포고무의 마찰 및 마모특성에 관한연구)

  • 범석훈
    • The Korean Journal of Rheology
    • /
    • v.7 no.1
    • /
    • pp.50-59
    • /
    • 1995
  • 겨울용 타이어인 '발포고무 타이어'의 트레드에 적용되는 발포고무의 물성과 마찰 및 마모특성을 조사하였다. 천연고무인 SMR-CV60과 합성고무인 BR-01(Cis-1, 4 Polybutadiene)을 70:30 비율로 혼합하였고 발포제로는 개질화된 azodicarbonamide (상품 명:UNICELL AD#2)을 변량 첨가하여 다양한 발포도의 발포고무를 준비하였다. 발포도의 증 가로 발포고무의 Young's modulus와 파괴에너지는 점진적으로 감소하였으나 Tan $\delta$ 는 일정한 값을 유지하였다. 매끄러운 유리표면위에서 높은 마찰계수를 보인 발포고무는 발포 도의 증가로 크게 감소하였고 거친 표면일수록 마찰계수는 상승하였다. 이같은 마찰계수의 증감경향이 교차되는 발포도는 30~40%이었다. $0^{\circ}C$에서의 마찰계수도 유리 표면에서감소하 고 거친표면에서 상승하는 경향을 보였으며 증감경향이 교차하는 발포도는 20%로 낮아졌 다. 마찰표면을 마그네시아 분말로 처리하면 전반적으로 마찰계수는 감소하였고 발포도의 크기에 관계없이 마찰표면이 거칠수록 큰 마찰계수를 나타내었다. 발포고무의 발포도가 커 지면 마모손실량도 비례하여 증가하였으며 발포도가 낮은 고무에서는 비교적 규칙적인 융기 간격이 보였으나 발포도가 30%이상으로 되면 불규칙적인 마모표면과 더불어 많은 마모 부 스러기가 관찰되었다.

  • PDF

Precision Profile Measurement on Roughly Processed Surfaces (거친 가공표면 형상의 고정밀 측정법 개발)

  • Kim, Byoung-Chang;Lee, Se-Han
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.1
    • /
    • pp.47-52
    • /
    • 2008
  • We present a 3-D profiler specially devised for the profile measurement of rough surfaces that are difficult to be measured with conventional non-contact interferometer. The profiler comprises multiple two-point-diffraction sources made of single-mode optical fibers. Test measurement proves that the proposed profiler is well suited for the warpage inspection of microelectronics components with rough surface, such as unpolished backsides of silicon wafers and plastic molds of integrated-circuit chip package.

  • PDF

표면 형상측정을 위한 큰 등가파장 회절격자 간섭계

  • 황태준;이혁교;김승우
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.178-179
    • /
    • 2000
  • 표면 형상측정은 산업계에서 요구되는 고부가가치 기계부품들의 표면 정보의 확보와 향상에 반드시 필요하다. 이는 정밀부품의 정상적인 기능 수행에 대한 판별과 예측에 중요한 위치를 차지한다. 광원파장의 1/4 이상의 단차를 측정할 수 없는 기존의 간섭계는 이러한 큰 단차와 거친 표면을 가지고 있는 기계가공된 표면들을 측정하는데 어려움이 있다. (중략)

  • PDF

The effects of local factors on the survival of dental implants: A 19 year retrospective study (임플란트의 생존율에 영향을 미치는 국소적 인자에 대한 19년간의 후향적 연구)

  • Kim, Sung-Hoi;Kim, Sun-Jai;Lee, Keun-Woo;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.28-40
    • /
    • 2010
  • Purpose: The aim of this retrospective study was to provide long-term data about the correlation between multifactorial local factors and the survival of implants. Material and methods: During 19 years (1991 to 2009), 2796 implants were placed in 879 patients. From dental charts and radiographs, the following data were collected: patient's age at implant placement, gender, implant system, surface, length, diameter, location of implant placement, bone quality, primary stability, type of prosthesis. The correlations between these data and implant survival were analyzed. Statistical analysis was performed using Kaplan-Meier survival analysis, Chi-square test, odds ratio. Results: 1. Among the 2796 implants, 150 implants failed that resulted in a cumulative survival rate of 94.64%. The cumulative survival rate of smooth surface implants (91.76%) was lower than rough surface implants (96.02%). 2. Anatomic location, implant surface, diameter of smooth surface implant, primary stability, type of prosthesis, patient's age and gender were significantly associated with implant survival (P < .05). 3. No significant difference in implant survival was found in relation to the following factors: implant length, bone quality, diameter of rough surface implants and type of rough surface according to implant manufacturer (P < .05). Conclusions: Local factors such as anatomic location, implant surface, diameter of smooth surface implant, primary stability and type of prosthesis have a significant effect on implant survival.

Effect of the Surface Roughness of Electrode on the Charge Injection at the Pentacene/Electrode Interface (전극 표면의 거칠기가 펜터신/전극 경계면의 전류-전압 특성에 주는 영향)

  • Kim, Woo-Young;Jeon, D.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.93-99
    • /
    • 2011
  • We investigated how the surface roughness of electrode affects the charge injection at the pentacene/Au interface. After depositing Au film on the Si substrate by sputtering, we annealed the sample to control the Au surface roughness. Pentacene and Au top electrode were subsequently deposited to complete the sample. The nucleation density of pentacene was slightly higher on the rougher Au electrode, but surface morphologies of thick pentacene films were similar on both the as-prepared and the roughened Au electrodes. The current-voltage curves obtained from the Au/pentacene/Au structure measured as a function of temperature indicated that the interface barrier was higher for the rougher Au bottom-electrode. We propose that the higher barrier was caused by the lower work function of rougher electrode surface and the higher trap density at the interface.

Diffraction grating interferometer of large equivalent wavelength for flatness testing of rough surfaces (거친 표면 형상측정을 위한 큰 등가파장 회절격자 간섭계)

  • 황태준;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.56-62
    • /
    • 2004
  • We present a diffraction grating interferometer of large equivalent wavelength specially designed for flatness testing of rough surfaces. Two transmission diffraction gratings are illuminated on the object under test by use of two measurement beams with different angles of incidence, which yields a large equivalent wavelength. This interferometer design minimizes unnecessary diffraction rays and the systematic error caused by the diffraction gratings, and provides a large working distance and easy alignment. To improve the measurement accuracy, phase shifting technique is applied and the equivalent wavelength error caused by defocus is calibrated. Test results obtained from mirror surfaces and machined rough surfaces are discussed.

Bond Splitting Strength and Behavior of GFRP Reinforcement with Roughened Surface (거친표면 GFRP 보강근의 쪼갬부착파괴강도 및 거동 고찰)

  • Moon, Do-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.23-29
    • /
    • 2011
  • In this experimental study, bond splitting strength and behavior were evaluated through pull-out tests. The tests were conducted on a GFRP rebar with roughened surface which was produced by Canadian manufacturer. The used variables in this study were rebar diameter, cover depth and compressive strength of concrete. For each variable, five specimens were made and tested to obtain good results. The bond splitting behavior was investigated from the relationship of pull-out force and slip. The experimental bond splitting strength was compared with the predicted strength obtained from the equations presented by some researchers. The results of the comparison demonstrated that the strength could be predicted well by using the Harajli et al's equation.