• Title/Summary/Keyword: 강제환기장치

Search Result 14, Processing Time 0.019 seconds

하이브리드 강제환기장치의 작동기준 및 설치위치에 관한 고찰

  • Kim, Nam-Gyu
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.38 no.9
    • /
    • pp.10-16
    • /
    • 2009
  • 하이브리드 환기설비 중 강제환기팬은 일반 강제환기방식처럼 팬의 용량은 [강 중 약]의 3단계로 운전이 가능하도록 규정하고 있다. 수동 및 자동환기를 위해 일부 환기업체를 중심으로 $CO_2$ 센서를 설치하여 공동주택의 실내환경 기준 농도인 1,000 ppm을 기준으로 자동으로 작동이 가능하도록 하고 있으며 $CO_2$ 센서는 controller에 내장하고 있다. 이때 환기팬이 자동으로 작동하기 위한 적절한 $CO_2$ 농도 및 $CO_2$ 센서의 적정위치에 대해 검토하고자 한다.

  • PDF

Characteristics of Cooling Effect Depending on Operation of Forced Ventilation Systems in a Single-span Plastic Greenhouse (강제환기장치 사용에 따른 단동 플라스틱 온실 기온 강하 특성)

  • Kim, Seong-Heon;Kim, Hyung-Kweon;Kwon, Jin-Kyung;Lee, Si-Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.143-151
    • /
    • 2022
  • This study was carried out to investigate quantitative characteristics of the cooling effect in a single-span arch greenhouse with roll-up side vents depending on operation of circulation and exhaust fans during ventilation, in order to suggest a practical strategy regarding installation or operation of forced ventilation systems. The examination was conducted under 3 different ventilation conditions (side vents only, side vents + circulation fans, and side vents + circulation fans + exhaust fans). In each condition, variations of internal and external air temperatures and exogenous environmental factors were recorded during ventilation, and the cooling effects were investigated by comparing the normalized temperature difference (NTD) of each ventilation condition. In the morning time (11:00-12:00), a temporary peak in the temperature difference was observed at the beginning of ventilation regardless of ventilation methods. The time taken to the maximum NTD was decreased from 340 s to 110s, and the NTD was dropped from 1.158 to 1.037 as the more forced ventilation systems were operated. The more operations caused the passing time over specific NTD values reduced by 60% as the time was reduced from 1,030 s to 550 s at NTD = 0.8, 1,610 s to 915 s at NTD = 0.6, and 2,315 s to 1,360 s at NTD = 0.4. The temporary peak in NTD was not observed in the afternoon time (14:00-15:00) but it was dropped as quickly as the ventilation started. Also the more operations resulted in the passing time over specific NTD values reduced by 70% as the time was reduced from 560 s to 345 s at NTD = 0.8, from 825 s to 540 s at NTD = 0.6, and from 1,145 s to 810 s at NTD = 0.4. Conclusively, the intervention of the forced ventilation system is recommended in the morning time or in high thermal conditions to achieve more effective and economical ventilation.

Experimental Study on the Effect of Ventilation System on Indoor Air Quality in New Apartment Buildings (신축 공동주택에서의 강제환기장치 사용에 따른 실내공기질 개선효과 실증연구)

  • Lee, Gyu-Dong;Park, Young-Sok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.143-146
    • /
    • 2006
  • There has been growing concern regarding IAQ(Indoor Air Quality) recently, and IAQ problems from the air-tightness and use of chemical materials addition to the building materials have become increasingly important factors in the built environment. Ventilation is supposed as the solution of healthy indoor quality, and Korea government requests that all new apartment buildings must have a ventilation system as a matter of duty since January, 2006. The purpose of this study is to investigate the indoor concentration change of VOCs include the Formaldehyde according to many different ventilation supply types. Results showed that the reduction effect of target pollutants by the ventilation system was very slight. The cause of these results was attribute to increase the emission rate of building materials by increasing the ventilation rate.

  • PDF

Time Course of $CO_2$ Exchange of Sweetpotato Cultures In Vitro with Different $CO_2$ Concentration under Forced Ventilation (고구마 조직배양묘의 $CO_2$교환량 연속 측정)

  • 오양숙;고재풍수;정순주
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1997.05a
    • /
    • pp.17-22
    • /
    • 1997
  • 본 연구에서는 고구마 조직배양묘의 $CO_2$ 교환량을 측정하기위해 개방형 광합성측정장치의 원리를 이용해 자체제작한 $CO_2$ 교환량 측정장치를 이용하여 공기 주입구와 배출구의 $CO_2$ 농도를 연속측정하고, 명기와 암기에 있어서의 $CO_2$ 교환량의 일변화를 분석했다. 내용적 1.48$\ell$의 배양기에 32개의 식물체를 이식했을 때 식물체당 일일 $CO_2$ 교환량은 19일째에 포화에 달했다. 식물체 생장에 있어서는 자연환기구보다 강제환기구의 생장이 촉진되었고, 강제환기구에서는 $CO_2$ 시용구가 무시용구보다 생장이 촉진되었다. 본 연구의 결과는 고구마 조직배양묘를 강제환기와 $CO_2$ 시용등 배양환경의 개선함으로써 순환과정을 거치지 않고 포장정식이 가능한 배양묘나 삽수의 생산이 가능함을 시사한다고 사료된다.

  • PDF

A study on the availability of ATS system in speed augmentation (속도 향상시의 ATS 시스템 가용성 연구)

  • Kim, Yong-Kyu;Baek, Jong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.238-240
    • /
    • 2004
  • 현재 우리나라에서 사용 중인 신호시스템은 지상신호 방식인 자동폐색장치(ABS)를 사용한다 이는 선로를 패색구간으로 배분한 후, 각각의 패색 구간에 설치된 신호기에 의해 열차의 이동을 실행한다 이러한 신호체계에 문제점이 발생할 경우, 기관사에게 주의를 환기시켜 강제적으로 열차를 정지시키는 역할을 하는 자동열차정지장치(ATS)가 1969년부터 도입, 사용 중에 있다. 본 논문에서는 ATS 시스템의 고속, 고밀도 운전 적용 가능성 및 차상신호방식 사용시의 ATS 적용 가능성에 대해 분석한다.

  • PDF

A Study on the Measurement of Dynamic Stability Derivatives in the Rolling Motion of Aircraft (항공기의 롤운동 동안정미계수 측정에 관한 연구)

  • Cho, Hwan-Kee
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.21 no.4
    • /
    • pp.41-46
    • /
    • 2013
  • This paper deals with an experimental technique for the measurement of dynamic stability derivatives in the roll motion of aircraft. Experimental aquisition method for aircraft's dynamic stability derivatives is conducted on the oscillation condition of aircraft model in the subsonic wind tunnel. The oscillation of aircraft model was forced by the oscillation apparatus. The forced oscillation technique is the method getting data from the internal balance inserted into the aircraft model during oscillating it. Dynamic stability derivatives of rolling motion were calculated by data reduction from the measurements of rolling moment, frequency and amplitude of aircraft model due to forced oscillation under wind conditions. Results of experiment is obtained similar one with those of roll dynamic stability derivatives measured in other institutes.

A Study on the Performance of Ondol with a Ventilation System (환기시스템을 갖춘 온돌 성능에 관한 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4047-4051
    • /
    • 2014
  • Modern apartment houses are constructed to be relatively airtight with a high heat insulation system to increase the energy efficiency. Such a system has a range of deleterious effects due to the insufficient ventilation. In this study, the ondol system, which is used as a heat source typical of winter in Korea, was set as the default system to evaluate the indoor heat environment according to the ventilation method, the factors of energy reduction by the ventilation system was analyzed. The experimental apparatus was used to simulate the ambient conditions for a certain constant temperature and humidity chamber. The experimental results showed that the supply water temperature higher air volume decreases with increasing supply air temperature in the following order: floor supply/exhaust > total heat exchange supply/exhaust > forced supply/exhaust. Through this study, the applicability of various ventilations could be examined.

A Study of the Cooling Effect of an Evaporation-Type Cool Roof Fan (기화방열식 Cool Roof Fan의 냉풍효과에 대한 연구)

  • Kim, Yeong Sik;Chung, Hanshik;Jeong, Hyomin;Choi, Soon-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.191-200
    • /
    • 2016
  • The ventilation effect of a ventilation system, which is classified as the forced ventilation and natural ventilation, is predominantly dependent on the combination of air supply and discharge. Perhaps the simplest ventilation is merely supplying the air as it is. However, to improve the indoor working environment during the summer, an air supply that is cooled to some extent has been widely adopted. Recently, a cooling method utilizing the vaporization of water was introduced. In this study, the performance of an evaporation-type air supply unit that was produced by Japan K-company and was installed in a shoe-manufacturing plant in Busan was investigated. The purpose of the experiment was to measure how much the supplied air could be cooled. From this experimental study, we confirmed that the evaporation-type air supply system is efficient, capable of improving the working environment during the summer while minimizing the energy cost.

Evaluation of Internal through Analysis of Airflow and Ventilation of Coal Storage Shed (옥내저탄장 기류 흐름 및 환기량 분석을 통한 내부 유동 평가)

  • Jo, Hyun-Joung;Lee, Jin-Hong
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.5
    • /
    • pp.334-342
    • /
    • 2022
  • The stringent air environment conservation act forced to build an indoor dome for coal storage. However, it causes some problems due to accumulation of fly ash and harmful substances inside. To solve this problem, this study analyzed the pattern of internal airflow and the amount of ventilation for an indoor coal yard. Overall, the airflow inside the indoor coal yard tended to move to the southwest facing the mountain. In addition, sea-breeze was blowing from the northern louver window facing the sea, where airflow was flowing in. The total flow rate flowing into the indoor coal yard was 918,691 m3/h, and the number of natural ventilation per hour was 0.6 times. Therefore, it is proposed to install a forced ventilation device at the location where internal air flow is concentrated.

Measurements of the Pitch Dynamic Stability Derivatives of a Standard Dynamics Model Using a Forced Vibration Technique (강제진동기법을 이용한 표준동역학 모델의 피치 동안정미계수측정)

  • Cho, Hwan-Kee;Kim, Seung-Pil;Baek, Seung-Woock;Chang, Jo-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.6
    • /
    • pp.489-495
    • /
    • 2007
  • An experimental study was carried out in order to measure the pitch dynamic stability derivatives of a standard dynamics model in a low-speed wind tunnel. When a trigger signal is generated, the aircraft model starts oscillation with constant amplitudes and frequencies provided by DC electrical servomotor. The measured data are simultaneously recorded on a data recorder for 25 cycles of the model oscillation. The Phase shift needed to compute the dynamic stability derivatives is determined by calculating differences between the peak values of the input and output signals from the dynamic stability balance. Stabilator effects on the stability derivatives were also investigated with deflection angles. Although the driving apparatus and experimental equipments manufactured creatively for this study are different from other experiments, the variational trend of dynamic stability derivatives with the angle of attack is in a good accordance with the results of TPI, NAE, and FFA.