• Title/Summary/Keyword: 강의

Search Result 38,206, Processing Time 0.068 seconds

A study on the Degradation and By-products Formation of NDMA by the Photolysis with UV: Setup of Reaction Models and Assessment of Decomposition Characteristics by the Statistical Design of Experiment (DOE) based on the Box-Behnken Technique (UV 공정을 이용한 N-Nitrosodimethylamine (NDMA) 광분해 및 부산물 생성에 관한 연구: 박스-벤켄법 실험계획법을 이용한 통계학적 분해특성평가 및 반응모델 수립)

  • Chang, Soon-Woong;Lee, Si-Jin;Cho, Il-Hyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.33-46
    • /
    • 2010
  • We investigated and estimated at the characteristics of decomposition and by-products of N-Nitrosodimethylamine (NDMA) using a design of experiment (DOE) based on the Box-Behken design in an UV process, and also the main factors (variables) with UV intensity($X_2$) (range: $1.5{\sim}4.5\;mW/cm^2$), NDMA concentration ($X_2$) (range: 100~300 uM) and pH ($X_2$) (rang: 3~9) which consisted of 3 levels in each factor and 4 responses ($Y_1$ (% of NDMA removal), $Y_2$ (dimethylamine (DMA) reformation (uM)), $Y_3$ (dimethylformamide (DMF) reformation (uM), $Y_4$ ($NO_2$-N reformation (uM)) were set up to estimate the prediction model and the optimization conditions. The results of prediction model and optimization point using the canonical analysis in order to obtain the optimal operation conditions were $Y_1$ [% of NDMA removal] = $117+21X_1-0.3X_2-17.2X_3+{2.43X_1}^2+{0.001X_2}^2+{3.2X_3}^2-0.08X_1X_2-1.6X_1X_3-0.05X_2X_3$ ($R^2$= 96%, Adjusted $R^2$ = 88%) and 99.3% ($X_1:\;4.5\;mW/cm^2$, $X_2:\;190\;uM$, $X_3:\;3.2$), $Y_2$ [DMA conc] = $-101+18.5X_1+0.4X_2+21X_3-{3.3X_1}^2-{0.01X_2}^2-{1.5X_3}^2-0.01X_1X_2+0.07X_1X_3-0.01X_2X_3$ ($R^2$= 99.4%, 수정 $R^2$ = 95.7%) and 35.2 uM ($X_1$: 3 $mW/cm^2$, $X_2$: 220 uM, $X_3$: 6.3), $Y_3$ [DMF conc] = $-6.2+0.2X_1+0.02X_2+2X_3-0.26X_1^2-0.01X_2^2-0.2X_3^2-0.004X_1X_2+0.1X_1X_3-0.02X_2X_3$ ($R^2$= 98%, Adjusted $R^2$ = 94.4%) and 3.7 uM ($X_1:\;4.5\;$mW/cm^2$, $X_2:\;290\;uM$, $X_3:\;6.2$) and $Y_4$ [$NO_2$-N conc] = $-25+12.2X_1+0.15X_2+7.8X_3+{1.1X_1}^2+{0.001X_2}^2-{0.34X_3}^2+0.01X_1X_2+0.08X_1X_3-3.4X_2X_3$ ($R^2$= 98.5%, Adjusted $R^2$ = 95.7%) and 74.5 uM ($X_1:\;4.5\;mW/cm^2$, $X_2:\;220\;uM$, $X_3:\;3.1$). This study has demonstrated that the response surface methodology and the Box-Behnken statistical experiment design can provide statistically reliable results for decomposition and by-products of NDMA by the UV photolysis and also for determination of optimum conditions. Predictions obtained from the response functions were in good agreement with the experimental results indicating the reliability of the methodology used.

Statistical Analysis of Operating Efficiency and Failures of a Medical Linear Accelerator for Ten Years (선형가속기의 10년간 가동률과 고장률에 관한 통계분석)

  • Ju Sang Gyu;Huh Seung Jae;Han Youngyih;Seo Jeong Min;Kim Won Kyou;Kim Tae Jong;Shin Eun Hyuk;Park Ju Young;Yeo Inhwan J.;Choi David R.;Ahn Yong Chan;Park Won;Lim Do Hoon
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.186-193
    • /
    • 2005
  • Purpose: To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2l00C over a ten year period were retrospectively analyzed. Materials and Methods: The failures were classified according to the involved functional subunits, with each class rated Into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Results: Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for $20\%$ of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and $83\%$ of the expected values, respectively. The operating efficiency was maintained at $95\%$ or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. Conclusion: The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. Wore rigorous equipment maintenance Is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the qualify of patient treatment.

Analysis of Bone Mineral Density and Related Factors after Pelvic Radiotherapy in Patients with Cervical Cancer (골반부 방사선 치료를 받은 자궁경부암 환자의 골밀도 변화와 관련 인자 분석)

  • Yi, Sun-Shin;Jeung, Tae-Sig
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.15-22
    • /
    • 2009
  • Purpose: This study was designed to evaluate the effects on bone mineral density (BMD) and related factors according to the distance from the radiation field at different sites. This study was conducted on patients with uterine cervical cancer who received pelvic radiotherapy. Materials and Methods: We selected 96 patients with cervical cancer who underwent determination of BMD from November 2002 to December 2006 after pelvic radiotherapy at Kosin University Gospel Hospital. The T-score and Z-score for the first lumbar spine (L1), fourth lumbar spine (L4) and femur neck (F) were analyzed to determine the difference in BMD among the sites by the use of ANOVA and the post-hoc test. The study subjects were evaluated for age, body weight, body mass index (BMI), post-radiotherapy follow-up duration, intracavitary radiotherapy (ICR) and hormonal replacement therapy (HRT). Association between the characteristics of the study subjects and T-score for each site was evaluated by the use of Pearson's correlation and multiple regression analysis. Results: The average T-score for all ages was -1.94 for the L1, -0.42 for the L4 and -0.53 for the F. The average Z-score for all ages was -1.11 for the L1, -0.40 for the L4 and -0.48 for the F. The T-score and Z-score for the L4 and F were significantly different from the scores for the L1 (p<0.05). There was no significant difference between the L4 and F. Results for patients younger than 60 years were the same as for all ages. Age and ICR were negatively correlated and body weight and HRT were positively correlated with the T-score for all sites (p<0.05). BMI was positively correlated with the T-score for the L4 and F (p<0.05). Based on the use of multiple regression analysis, age was negatively associated with the T-score for the L1 and F and was positively correlated for the L4 (p<0.05). Body weight was positively associated with the T-score for all sites (p<0.05). ICR was negatively associated with the T-score for the L1 (p<0.05). HRT was positively associated with the T-score for the L4 and F (p<0.05). Conclusion: The T-score and Z-score for the L4 and F were significantly higher than the scores for the L1, a finding in contrast to some previous studies on normal women. It was thought that radiation could partly influence BMD because of a higher T-score and Z-score for sites around the radiotherapy field. We suggest that a further long-term study is necessary to determine the clinical significance of these findings, which will influence the diagnosis of osteoporosis based on BMD in patients with cervical cancer who have received radiotherapy.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Professional Speciality of Communication Administration and, Occupational Group and Series Classes of Position in National Public Official Law -for Efficiency of Telecommunication Management- (통신행정의 전문성과 공무원법상 직군렬 - 전기통신의 관리들 중심으로-)

  • 조정현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.3 no.1
    • /
    • pp.26-27
    • /
    • 1978
  • It can be expected that intelligence and knowledge will be the core of the post-industrial society in a near future. Accordingly, the age of intelligence shall be accelerated extensively to find ourselves in an age of 'Communication' service enterprise. The communication actions will increase its efficiency and multiply its utility, indebted to its scientic principles and legal idea. The two basic elements of communication action, that is, communication station and communication men are considered to perform their function when they are properly supported and managed by the government administration. Since the communication action itself is composed of various factors, the elements such as communication stations and officials must be cultivated and managed by specialist or experts with continuous and extensive study practices concerned. With the above mind, this study reviewed our public service officials law with a view to improve it by providing some suggestions for communication experts and researchers to find suitable positions in the framework of government administration. In this study, I would like to suggest 'Occupational Group of Communication' that is consisted of a series of comm, management positions and research positions in parallel to the existing series of comm, technical position. The communication specialist or expert is required to be qualified with necessary scientific knowledge and techniques of communication, as well as prerequisites as government service officials. Communication experts must succeed in the first hand to obtain government licence concerned in with the government law and regulation, and international custom before they can be appointed to the official positions. This system of licence-prior-to-appointment is principally applied in the communication management position. And communication research positions are for those who shall engage themselves to the work of study and research in the field of both management and technical nature. It is hopefully expected that efficient and extensive management of communication activities, as well as scientific and continuous study over than communication enterprise will be upgraded at national dimensions.

  • PDF

Studies on effect and Safety of various Aqua-acupunctures from Scutellariae Radix (다양(多樣)한 황금약침제제(黃芩藥鍼製劑)의 안전성(安定性) 및 효능(效能)에 관한 연구(硏究))

  • Kim, Ho-Kyoung;Ma, Jin-Yeul;Cheon, Won-Kyung;Yun, Su-Young;Kang, Eun-Jung;Joo, Hye-Jeong;Ko, Byoung-Seob
    • Korean Journal of Oriental Medicine
    • /
    • v.3 no.1
    • /
    • pp.183-197
    • /
    • 1997
  • In order to detect the safety and effect of various aqua-acupunctures from Scutellariae Radix, the modifications of boiling, filtration and dilution were employed for the manufacture of aqua-acupunctures. We injected 0.2cc of aqua-acupunctures into Joksamri (足三里) of rat, repeatedly. We compared subacute toxicity of them with saline group, distilled water(D.W.) group, acupuncture group and control group. The results were summarized as follows: 1. The groups were all healthy and alive, and there was no special abnormality in physical condition and autopsy. And there were not any toxic symptoms in repeating application of aqua-acupunctures to the rat, including changes of body weight, organ weight, haematological examination and serum biochemical test. 2. There was slight change of body weight in acupuncture group : We could see significance after 3 days(p<0.05) and after 7 days(p<0.001) in body weight loss. After 9 days, all tested groups were suppressed in body weight increment. 3. Result of organ weight : In Palkang aqua-acupuncture(D-2 group), saline group and acupuncture group there were some statistical significance. Especially, acupuncture group revealed significant result in liver and spleen than aqua-acupunctures. From this result, we could suggest that the efficacy of acupuncture was preceded herbal medicine. 4. In serum biochemical test, we examined glucose(GLU), triglyceride(TG) and cholesterol(CHOL). In comparison with control group, the diluted 10 times of Hwanggum aqua-aqupuncture$({\times}10\;group)$ was recognized significant decrease of glucose, but the diluted 100 times of Hwanggum aqua-acupuncture$({\times}100\;group)$, D-2 group, saline group were confirmed significant increment. There was not any meaningful change of CHOL in all of tested group, excepting the acupuncture group was exhibited statistically significant decrease(p<0.05). In TG level all tested group except complex injection of standard compound(CPA group) and HG, there were significant value iii statistically. The diluted solution was more significant decrease than Hwanggum aqua-acupuncture(HG). The mutual relationship of components of aqua-acupunture tended to decrease level of TG, regardless of its concentration. In acupunture guoup, we gained some interesting result In meaningful decrease in 7G. 5. Haematological examination showed significant increment of granulocytes(GR) in all tested groups except Hwanggum aqua-acupuncture. And the diluted solutions of HG expressed very high increment of them(p<0.001). The GR and Mean Corpuscular Volume(MCV) of acupuncture group showed statistical significance.

  • PDF

Actual Conditions and Perception of Safety Accidents by School Foodservice Employees in Chungbuk (충북지역 학교급식 조리종사원의 안전사고 실태 및 인식)

  • Cho, Hyun A;Lee, Young Eun;Park, Eun Hye
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.10
    • /
    • pp.1594-1606
    • /
    • 2014
  • The purpose of this study was to examine safety accidents related to school foodservice, working and operating environments of school foodservice, status and awareness of safety education, educational needs, and information on qualitative improvement of school foodservice. The subjects in this study were 234 cooks in charge of cooking at elementary and secondary schools in Chungbuk. A survey was conducted from July 30 to August 8, 2012, and among 202 questionnaires gathered, 194 completed questionnaires were analyzed. Statistical analyses were performed on data utilizing the SPSS version 19.0. The main results of this study were as follows: 44.3% of workers experienced safety accidents. The most frequent safety accident was 'once' (60.5%), and most safety accidents took place between June and August (31.4%). The time at which most safety accidents happened was between 8 and 11 am. Most safety accidents happened during cooking (52.3%) and while using a soup pot or frying pot (52.4%). The most common accidents were 'burns', 'wrist and arm pain', and 'slips and falls'. Respondents who experienced safety accidents replied that 57.6% of employees dealt with injuries at their own expense, and only 35.3% utilized industrial accident insurance. In terms of the operating environment, the score for 'offering information and application' was highest (3.76 points), whereas that for 'security of budget' was lowest (1.77 points). As for accident education, employees received safety education approximately 3.45 times and 5.10 hours per year. Improving the working environment of school foodservice cooks requires administrative and financial support. Furthermore, educational materials and guidelines based on the working environment and safety accident status of school foodservice cooks are required in order to minimize potential risk factors and control safety accidents in school foodservice.

The Continuous Monitoring of Oxygen Saturation During Fiberoptic Bronchoscopy (기관지내시경 검사시 지속적인 동맥혈 산소포화도 감시의 필요성)

  • Kang, Hyun Jae;Kim, Yeon Jae;Chyun, Jae Hyun;Do, Yun Kyung;Lee, Byung Ki;Kim, Won Ho;Park, Jae Yong;Jung, Tae Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.4
    • /
    • pp.385-394
    • /
    • 2002
  • Background : Flexible fiberoptic bronchoscopy(FFB) has become a widely performed technique for diagnosing and managing pulmonary disease because of its low complication and mortality rate. Since the use of FFB can in patients with severely depressed cardiorespiratory function is increasing and hypoxemia during the FFB can induce significant cardiac arrhythmias, the early detection and adequate management of hypoxemia during FFB is clinically important. Method : To evaluate the necessity of the continuous monitoring of the oxygen saturation($SaO_2$) during the FFB, the $SaO_2$ was continuously monitored from the finger tip using pulse oximetry before, during and after the FFB in 379 patient. The patients were then divided into two groups, those with and without hypoxemia($SaO_2$<90%). The baseline pulmonary function data and the clinical characteristics of the two groups were compared. Results : The mean baseline $SaO_2$ was $96.9{\pm}2.85%$. An $SaO_2$ <90% was recorded at some point in 62(16.4%) out of 379 patients, with 12 out of 62 experiencing this prior to the FFB, in 37 out of 62 during the FFB, and in 13 out of 62 after the FFB. No differences were observed in the smoking and sex distribution between those with and without hypoxemia. The mean age was older in those with hypoxemia than in those without. Significant differences were observed in the mean baseline $SaO_2$ and the mean time for the procedure between the two groups. The $FEV_1$ was significantly lower in those with hypoxemia, and both the FVC and $FEV_1/FVC$ also tended to decrease in this group. Managing hypoxemia included deep breathing in 20 patients, a supplemental oxygen supply in 39 patients, and the abortion of the procedure in 3 patients. Conclusion : These results suggest that the continuous monitoring of the oxygen saturation is necessary during fiberoptic bronchoscopy, and it should be performed in patients with a depressed pulmonay function in order for the early detection and adequate management of hypoxemia.

Studies on Properties of Superplasticized Fly Ash Concrete (고류동화제(高流動化劑)를 사용한 플라이애쉬 콘크리트의 제성질(諸性質)에 관한 연구(硏究))

  • Kim, Seong Wan;Sung, Chan Yong;Cho, Il Ho
    • Korean Journal of Agricultural Science
    • /
    • v.16 no.2
    • /
    • pp.212-224
    • /
    • 1989
  • This paper reports results of an investigation to determine properties of superplasticizered fly ash concrete. The mixture proportions of fly ash were 0, 10, 20 and 30%, by weight of cement, and superplasticizer was added as a percentage of fly ash, 0, 0.6, 12 and 1.8%. To investigate the effective use of the superplasticized fly ash concrete, the basic data were analyzed. The results obtained were summarized as follows : 1. The unit water content was decreased by 1%, 6% and increased by 2% to the ratio of addition of fly ash 10%, 20%, 30%, respectively, but in case of the superplasticized fly ash concrete, it was decreased by 3~16%, 4~14% and 10~17%, at 0.6, 12, and 1.8% dosage of superplasticizer, respectively. 2. In the properties of the fresh fly ash concrete, the slump loss was reduced with the ratio of replacement of fly ash increased, and with times went by. When using superplasticizer in fly ash substituting concrete, the fludity in the concrete was not decreased. 3. The compressive strength of fly ash concrete at early ages was lower than that of ordinary concrete. At the later age of 28 days, the compressive strength with 20% addition of fly ash was increased than that of ordinary concrete. In cased of 10%, 30% addition of fly ash, the compressive strength were reduced. From this, it was proved that the optimum amount of fly ash appears to be about 20%. The compressive strength at all ages of superplasticized fly ash concrete was significantly higher than that of fly ash concrete, with increasing fly ash content. 4. In case of the tensile strength, the effects of the increasing strength with the ages were similar to those of the compressive strtength, and at the later ages was seen a decreasing tendency of strengths. 5. The correlation between compressive and tensile strength of superplasticized fly ash concrete was highly significant. The multiple regression equations of compressive and tensile strength were obtained on a function of the mixture proportion of fly ash and the addition of superplasticizer. The relation between compressive and tensile strength is higher than for ordinary concrete. The strength ratio is 7~11, and it is higher than that of ordinary concrete, 8~10. 6. Bulk density was decreased by 1~3% compared with ordinary concrete with the mixture proportion of fly ash increased, 10~30%, and decreased by 1~2% with the superplasticizer added 0.6~1.8%.

  • PDF

Experimental studies on the characteristics of the mortar using dispersing agent of cement and high fluid admxiture (시멘트 분산제(分産劑) 및 고류동화제(高流動化劑)를 사용(使用)한 모르터의 제(諸) 성질(性質)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Kim, Seong Wan;Park, In-Gyu
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.1
    • /
    • pp.146-159
    • /
    • 1984
  • This study was the contrast of the compressive strength, the tensile strength, the reducing ratio and the flow of mortar using dispersing agent and high fluid admix. 1. The admix ratio of chemical admixtures espressing maximum strength appeared the same result high fluid admix SP was 0.6%, the dispersing agents LG and C211 were 0.2%, SK was 0.3%, C376 was 0.5%. But two or three times more than standard quantity made the strength's fast lowness, which influenced bad to wateriness and retard the soli-dification. 2. When proper quantity of chemical admixture was used, the increment of compressive strength was as follows. High fluid admix SP was 40.7% and the average increasing rate of dispersing agents(C211 was 19.5%, LG was 19.1%, C376 was 17.9%) was 18.7% more than normal mortar in the codition of 7 days. Also, in the condition of 28 days, high fluid admix SP was about 24.4% and the average of dispersing agents(LG was 21.1%, C211 was 16.4%, SK was 11.1%, C376 was 7.6%) was 14.1%. 3. When proper quantity of chemical admixture was used, the increment of tensile strength was as follows. High fluid admixture SP was 26.6% and the average increasing agents(SK was 16.0%, C376 was 14.7%, LG was 10%, C211 was 5.8%) was 11.6%. Also, in the condition of 28 days, high fluid admix SP was 16.5% and the average increasing rate of dispersing agents(LG was 19.1%, SK was 10.6%, C211 was 10.1%, C376 was 8.7%) was 12.1%. 4. As for the reducing ratio of each dispersing agent, he flow of mortar was less than the slump of concrete. That is; the reducing ratio of concrete was 15% adding each dispersing agent, but the reducing ratio of mortar was in the range of from 5.8% to 13.5% in 1 : 1 mixture, from 7.6% to 14.2% in 1 : 2, from 9.5% to 18.8% in 1 : 3. 5. The fluidity of each chemical admixture was as follows. High fluid admix SP in the condition of 1: 1 and 1 : 2 showed the best result than other dispersing agent and 1 : 3 showed the same result like other agents. Therefore these good dispersing agents were suitable in the prepact concrete construction using intrusion mortar.

  • PDF