• Title/Summary/Keyword: 감쇠 지수

Search Result 118, Processing Time 0.027 seconds

Assessment of Eutrophication Using Trophic State Index and Water Quality Characteristics of Saemangeum Lake (새만금호의 수질 특성 및 영양상태지수를 이용한 부영양화 평가)

  • Jong Gu Kim
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.587-597
    • /
    • 2023
  • We evaluated the eutrophication of Saemangeum Lake, which causes abnormal growth of algae, using the Carlson index. Eutrophication characteristics of Saemangeum Lake were analyzed. For the study, water quality surveys were conducted at 7 stations in Saemangeum Lake every month in 2021. The concentration of Chl.a was slightly higher in the Mankyeong water system in winter, and slightly higher in the Dongjin water system in spring and summer, but overall, except for some periods, the concentration was similar to or lower than the lake water quality environmental standard of class 3. COD showed water quality similar to or above the lake quality environmental standard of grade 4 in both the Mankyeong and Dongjin water systems in the summer and Autumn. TOC concentrations were within lake water quality standard 3 at all sites. Total phosphorus concentrations exceeded the lake water quality standard of Class 4 and were higher in January and August after rainfall. In the correlation analysis between water quality factors, the correlation of organic matter, total phosphorus, and total nitrogen to salinity was relatively high. This reflected the water quality characteristics of freshwater, brackish water, and seawater areas due to seawater inflow through the drainage gate and freshwater inflow through upstream rivers. According to the characteristics of eutrophication fluctuations in Saemangeum Lake by trophic state index, the indices of Chl.a, SD, and TN showed water quality in the early stage of eutrophication, while the TP index showed a severe eutrophication state. The magnitude of the eutrophication index among water quality components was TSI(TP) > TSI(TN) > TSI(SD) > TSI(CHL) in all water systems. Quadrant analysis of the deviation of TSI(CHL) from TSI(TP) and TSI(SD) on a two-dimensional plane showed that there was no limiting effect of total phosphorus on algal growth in all water systems. In addition, the factors af ecting light attenuation appeared to be dominated by small particulate matter from outside sources.

On the vibration influence to the running power plant facilities when the foundation excavated of the cautious blasting works. (노천굴착에서 발파진동의 크기를 감량 시키기 위한 정밀파실험식)

  • Huh Ginn
    • Explosives and Blasting
    • /
    • v.9 no.1
    • /
    • pp.3-13
    • /
    • 1991
  • The cautious blasting works had been used with emulsion explosion electric M/S delay caps. Drill depth was from 3m to 6m with Crawler Drill ${\phi}70mm$ on the calcalious sand stone (soft -modelate -semi hard Rock). The total numbers of test blast were 88. Scale distance were induced 15.52-60.32. It was applied to propagation Law in blasting vibration as follows. Propagtion Law in Blasting Vibration $V=K(\frac{D}{W^b})^n$ were V : Peak partical velocity(cm/sec) D : Distance between explosion and recording sites(m) W : Maximum charge per delay-period of eight milliseconds or more (kg) K : Ground transmission constant, empirically determind on the Rocks, Explosive and drilling pattern ets. b : Charge exponents n : Reduced exponents where the quantity $\frac{D}{W^b}$ is known as the scale distance. Above equation is worked by the U.S Bureau of Mines to determine peak particle velocity. The propagation Law can be catagorized in three groups. Cubic root Scaling charge per delay Square root Scaling of charge per delay Site-specific Scaling of charge Per delay Plots of peak particle velocity versus distoance were made on log-log coordinates. The data are grouped by test and P.P.V. The linear grouping of the data permits their representation by an equation of the form ; $V=K(\frac{D}{W^{\frac{1}{3}})^{-n}$ The value of K(41 or 124) and n(1.41 or 1.66) were determined for each set of data by the method of least squores. Statistical tests showed that a common slope, n, could be used for all data of a given components. Charge and reduction exponents carried out by multiple regressional analysis. It's divided into under loom over loom distance because the frequency is verified by the distance from blast site. Empirical equation of cautious blasting vibration is as follows. Over 30m ------- under l00m ${\cdots\cdots\cdots}{\;}41(D/sqrt[2]{W})^{-1.41}{\;}{\cdots\cdots\cdots\cdots\cdots}{\;}A$ Over 100m ${\cdots\cdots\cdots\cdots\cdots}{\;}121(D/sqrt[3]{W})^{-1.66}{\;}{\cdots\cdots\cdots\cdots\cdots}{\;}B$ where ; V is peak particle velocity In cm / sec D is distance in m and W, maximLlm charge weight per day in kg K value on the above equation has to be more specified for further understaring about the effect of explosives, Rock strength. And Drilling pattern on the vibration levels, it is necessary to carry out more tests.

  • PDF

Measurement of the Noise Parameters of On-Wafer Type DUTs Using 8-Port Network (8-포트회로망을 이용한 온-웨이퍼형 DUT의 잡음파라미터 측정)

  • Lee, Dong-Hyun;Ahmed, Abdule-Rahman;Lee, Sung-Woo;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.8
    • /
    • pp.808-820
    • /
    • 2014
  • In this paper, we fabricated two on-wafer type DUT(Device-Under-Test)s; a 10-dB attenuator and an amplifier using commercially available MMIC and we proposed the measurement method of the noise parameters for the two fabricated DUTs. Since the 10-dB attenuator DUT is a passive device, its noise parameters can be accurately determined when its S-parameters are measured. In the case of the amplifier DUT, its noise parameters are available in the datasheet. Hence, the measured noise parameters using the proposed method can be assessed by comparing with the known noise parameters. The noise parameter measurement method having been presented by the authors requires the S-parameters of the 8-port network used in the measurement and limited to coaxial type DUTs. When on-wafer probes are included in the 8-port network, the 8-port S-parameters requires the measurements with different kinds of connectors. In this paper, we obtained the 8-port S-parameters using the Smart-Cal function in the network analyzer. The measured noise parameters shows about ${\pm}0.2dB$ fluctuations for $NF_{min}$. Other noise parameters with the frequency change show good agreement with the expected results.

A Modeling Study on the AVO and Complex Trace Analyses of the Fracture Bone Reflection (파쇄대 반사에너지의 AVO 및 복소트레이스 분석에 관한 모형연구)

  • Han Soo-Hyung;Kim Ji-Soo;Ha Hee-Sang;Min Dong-Joo
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.1
    • /
    • pp.33-42
    • /
    • 1999
  • AVO and complex trace analyses mainly used to characterize natural gas reservoir were tested in this paper for a possible application to detection of major geological discontinuities such as fracture zones. The test data used in this study were calculated by utilizing a viscoelastic numerical program which was based on the generalized Maxwell body for a horizontal fracture model. In AVO analysis of a horizontal fracture zone, p-wave reflection appears to be variant depending upon the acoustic-impedence contrast and the offset distance. The fracture zone is also effectively clarified both in gradient stack and range-limited stack in which fracture zone reflection is attenuated with the increasing offset distance. In complex attribute plots (instantaneous amplitude, frequency, and phase), the top and bottom of the fracture Tone are characterized by a zone of strong amplitudes and an event of the same phase. Low frequency characteristics appear at the fracture zone and the underneath. Amplitude attenuation and waveform dispersion are dependent on Q-contrast between the fracture zone and the surrounding media. They were properly compensated by optimum inverse Q-filtering.

  • PDF

Robust 1D inversion of large towed geo-electric array datasets used for hydrogeological studies (수리지질학 연구에 이용되는 대규모 끄는 방식 전기비저항 배열 자료의 1 차원 강력한 역산)

  • Allen, David;Merrick, Noel
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.1
    • /
    • pp.50-59
    • /
    • 2007
  • The advent of towed geo-electrical array surveying on water and land has resulted in datasets of magnitude approaching that of airborne electromagnetic surveying and most suited to 1D inversion. Robustness and complete automation is essential if processing and reliable interpretation of such data is to be viable. Sharp boundaries such as river beds and the top of saline aquifers must be resolved so use of smoothness constraints must be minimised. Suitable inversion algorithms must intelligently handle low signal-to-noise ratio data if conductive basement, that attenuates signal, is not to be misrepresented. A noise-level aware inversion algorithm that operates with one elastic thickness layer per electrode configuration has been coded. The noise-level aware inversion identifies if conductive basement has attenuated signal levels so that they are below noise level, and models conductive basement where appropriate. Layers in the initial models are distributed to span the effective depths of each of the geo-electric array quadrupoles. The algorithm works optimally on data collected using geo-electric arrays with an approximately exponential distribution of quadrupole effective depths. Inversion of data from arrays with linear electrodes, used to reduce contact resistance, and capacitive-line antennae is plausible. This paper demonstrates the effectiveness of the algorithm using theoretical examples and an example from a salt interception scheme on the Murray River, Australia.

Seismic Performance of Circular RC Bridge Columns with Longitudinal Steel Connection Details (축방향철근 연결상세에 따른 철근콘크리트 원형교각의 내진성능)

  • Lee Jae-Hoon;Son Hyeok-Soo;Ko Seong-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.249-260
    • /
    • 2004
  • The longitudinal steel connection of reinforced concrete bridge column is sometimes practically unavoidable, however the current Korean bridge design specifications have no special provisions about lap-splices of longitudinal steel. This paper reports experimental results of a research program investigating the seismic performance of circular RC bridge columns with respect to longitudinal steel connection detailing. Twenty-one circular column specimens were tested under quasi-static test. The columns with the entire longitudinal steel lap-spliced within plastic hinge region show relatively sudden strength degradation and low ductility than the columns with continuous longitudinal steel and the columns with half of longitudinal steel lap-spliced. However, the seismic performance of the column with mechanically connected longitudinal steel is similar to that of the column with continuous longitudinal steel. The final objectives of this study are to suggest appropriate longitudinal reinforcement connection details for the limited ductility design concept and to provide quantitative reference data and tendency for performance or damage assessment based on the performance levels such as cracking, yielding, collapse, etc. Ultimate displacement/drift ratio, displacement ductility, response modification factor, equivalent viscous damping ratio, residual deformation index, and effective stiffness are investigated and discussed in this paper.

레일레이 입사각에서 Schoch 변위가 액체/고체 경계면으로부터 후방산란되는 초음파 에너지에 미치는 영향

  • Lee Jeong-Ki;Kim H. C.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.409-416
    • /
    • 1999
  • 액체/고체 경계면에 레일레이각으로 초음파 pulse를 입사시키면 입사된 에너지의 상당 부분이 고체쪽으로 침투여 표면으로부터 약 1.5 파장 깊이 정도까지 에너지 분포를 가지고 고체 표면을 따라 전파하는 레일레 이파로 전환되며, 이러한 입사각에서는 기하학적인 거울 반사가 일어나지 않고 반사파의 중심이 Schoch 변위만큼 전방으로 이동되고, 또 입사 방향으로 후반 산란되는 초음파의 신호가 급격히 증가하는 현상이 관찰된다. 만일 고체에서 초음파의 감쇠가 산란에 의해 크게 영향을 받고, 레일레이각에서 고체 쪽으로 침투한 에너지의크기를 $E_0$라고 하면, 고체 표면과 표면 근처를 전파하는 레일레이파의 산란파 에너지, $E_S$는 Schoch 변위, ${\Delta}_S$와 산란에 의한 감쇠계수 ${\alpha}_S$에 비례하는 관계가 있음을 이론적으로 구하였다. 입사 방향으로 후방산란되는 초음파는 산란파의 일부이므로 후방산란 초음파 에너지, E_{Bs}도 이와 같은 관계를 가진다. 그러므로, 레일레이각으로 입사된 초음파의 후방산란 에너지, $E_{B_S}$ 산란체(e.g. grain)의 평균 크기, D와 주파수 f와는 레일레이 산란 영역과 Stochastic 산란 영역에 대해 각각 $E_{B_S}\;\propto\;D^{3}f^{3}$$E_{B_S}\;\propto\;D\;f$인 관계를 가지는 것으로 얻어졌다. 이것은 액체/고체 경계면에서 레일레이각으로 입사되어 레일레이파로 전환된 초음파가 다시 액체로 그 에너지를 누설하여 그 산란 영역이 Schoch 변위 내에서 일어나기 때문이며, 이러한 영향에 의해서일반적인 산란에서의 주파수 의존성과는 달리 각 산란 영역에서 그 지수는 1씩 작은 값을 갖는다.향에 따라 음장변화가 크게 다를 것이 예상되므로 이를 규명하기 위해서는 궁극적으로 3차원적인 음장분포 연구가 필요하다. 음향센서를 해저면에 매설할 경우 수충의 수온변화와 센서 주변의 수온변화 사이에는 어느 정도의 시간지연이 존재하게 되므로 이에 대한 영향을 규명하는 것도 센서의 성능예측을 위해서 필요하리라 사료된다.가지는 심부 가스의 개발 성공률을 증가시키기 위하여 심부 가스가 존재하는 지역의 지질학적 부존 환경 및 조성상의 특성과 생산시 소요되는 생산비용을 심도에 따라 분석하고 생산에 수반되는 기술적 문제점들을 정리하였으며 마지막으로 향후 요구되는 연구 분야들을 제시하였다. 또한 참고로 현재 심부 가스의 경우 미국이 연구 개발 측면에서 가장 활발한 활동을 전개하고 있으며 그 결과 다수의 신뢰성 있는 자료들을 확보하고 있으므로 본 논문은 USGS와 Gas Research Institute(GRI)에서 제시한 자료에 근거하였다.ऀĀ耀Ā삱?⨀؀Ā Ā?⨀ጀĀ耀Ā?돀ꢘ?⨀硩?⨀ႎ?⨀?⨀넆돐쁖잖⨀쁖잖⨀/ࠐ?⨀焆덐瀆倆Āⶇ퍟ⶇ퍟ĀĀĀĀ磀鲕좗?⨀肤?⨀⁅Ⴅ?⨀쀃잖⨀䣙熸ጁ↏?⨀

  • PDF

Development $K_d({\lambda})$ and Visibility Algorithm for Ocean Color Sensor Around the Central Coasts of the Yellow Sea (황해 중부 연안 해역에서의 해색센서용 하향 확산 감쇠계수 및 수중시계 추정 알고리즘 개발)

  • Min, Jee-Eun;Ahn, Yu-Hwan;Lee, Kyu-Sung;Ryu, Joo-Hyung
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.4
    • /
    • pp.311-321
    • /
    • 2007
  • The diffuse attenuation coefficient for down-welling irradiance $K_d({\lambda})$, which is the propagation of down-welling irradiance at wavelength ${\lambda}$ from surface to a depth (z) in the ocean, and underwater visibility are important optical parameters for ocean studies. There have been several studies on $K_d({\lambda})$ and underwater visibility around the world, but only a few studies have focused on these properties in the Korean sea. Therefore, in the present study, we studied $K_d({\lambda})$ and underwater visibility around the coastal area of the Yellow Sea, and developed $K_d({\lambda})$ and underwater visibility algorithms for ocean color satellite sensor. For this research we conducted a field campaign around the Yellow Sea from $19{\sim}22$ September, 2006 and there we obtained a set of ocean optical and environmental data. From these datasets the $K_d({\lambda})$ and underwater visibility algorithms were empirically derived and compared with the existing NASA SeaWiFS $K_d({\lambda})$ algorithm and NRL (Naval Research Laboratory) underwater visibility algorithm. Such comparisons over a turbid area showed small difference in the $K_d({\lambda})$ algorithm and constants of our result for underwater visibility algorithm showed slightly higher values.

A study on the standard for determining airborne sound insulation performance of sound barrier panels (방음판의 음향투과손실 측정규격에 관한 연구)

  • Oh, Yang Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.302-311
    • /
    • 2022
  • Sound barrier walls are one of the most effective alternatives for reducing environmental noise on roads and railways in the city center. The insertion loss of the sound barrier against road traffic noise is the sum of the sound transmission loss, sound absorption loss, and sound energy reduction due to the diffraction attenuation of the sound barrier. The sound transmission loss of the sound barrier is one of the important factors that determine the insertion loss of the sound barrier and is a basic indicator that determines the performance of the sound barrier. Nevertheless, there is not a separate standard in Korea for measuring the acoustic transmission loss of sound barrier panels. There are only a few conditions in KS F 4770 series that stipulates on the general material of sound barrier panels. This thesis examines the necessity of the acoustic transmission loss measurement and evaluation standards of sound barrier walls, and seeks a measurement method in a free sound field (anechoic chamber) sound receiving room considering the characteristics of sound barrier walls installed in external spaces, unlike indoor building materials. In addition, a single number evaluation method using a reference spectrum was proposed so that the sound insulation effect according to various installation places such as roadside or railroad side can be easily displayed.

Ground Vibration Tests of SmartUAV Airframe Structure (스마트무인기 기체구조물 지상진동시험)

  • Jeon, Byoung-Hee;Kang, Hui-Won;Lee, Jung-Jin;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.5
    • /
    • pp.482-489
    • /
    • 2010
  • This paper describes the test procedure, instrumentation, verification methodology and the results of the ground vibration test(GVT) and force vibration test(FVT) of the SmartUAV aircraft to estimate experimentally dynamic characteristics of the aircraft. Bungee cords are used to emulate free-free boundary conditions of the test aircraft. The SmartUAV is excited by three shakers and one-hundred frequency response functions(FRF's) is measured. The FRF's are reduced and analyzed to identify the dynamics parameters of the SmartUAV. To extract modal parameters of the SmartUAV such as, natural frequencies and damping ratios, the poly-reference least square complex exponential method is used in the time domain. The mode shape coefficients are estimated with the least squares frequency domain method to identify the vibration modes. The FVT was performed by fixed sine frequency with three shakers on the x, y and z direction and vibration characteristics of structures and detail equipments are measured.