• Title/Summary/Keyword: 감마 지수

Search Result 82, Processing Time 0.027 seconds

The Relative Effectiveness of Various Radiation Sources on the Resistivity Change in n-Type Silicon

  • Jung, Wun
    • Nuclear Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.91-101
    • /
    • 1969
  • Resistivity changes of n-type float-zone silicon crystals with 6.4$\times$10$^{14}$ to 1.25$\times$10$^{17}$ phosphorus atoms/㎤ due to irradiation by (1) 1 MeV electrons, (2) two types of research reactors, and (3) $Co^{60}$ ${\gamma}$-ray sources were investigated. The results were analyzed on the basis of a simple exponential formula derived by Buehler. While the formula gave a fair fit in the low fluence range in most cases, the deviation was quite appreciable in the case of 1 MeV electron irradiation, and a linear change gave better fit in some cases. The large change in the carrier removal rate in electron-irradiated samples in the high fluence range was analyzed in detail in terms of the Fermi level cross-over of the defect levels. Based on the damage constants evaluated from the initial portion of data where the formula was applicable, the relative effectiveness of various radiation sources in causing the resistivity change in n-type silicon was compared. The TRIGA Mark II reactor neutrons, for example, were found to be about 40 times more effective than 1 MeV electrons. The dependence of the damage constant on the initial carrier concentration was also examined. The physical basis of the exponential law and the effect of the Fermi level cross-over of the defect levels on the resistivity change in the high fluence ranges are discussed.

  • PDF

Comparison of the Serum Gamma-Glutamyl Transferase and Serum Uric Acid Levels according to the Obesity Types Based upon on the Body Mass Index in Korean Men (성인 남성에서 체질량지수로 분류한 비만 유형에 따른 혈청 감마 글루타밀 전이효소와 혈청 요산농도의 차이 비교)

  • Shin, Kyung A
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.50-56
    • /
    • 2019
  • This study examined the relationship between the serum GGT (gamma-glutamyl transferase) and uric acid level in obese male adults. A total of 14,283 adult males aged 20 years or more, who visited the health examination center of Gyeonggi Regional General Hospital from January 2017 to August 2018 and underwent a physical examination, were enrolled in this study. The obesity criteria were defined by the Asia-Pacific regional standards. Abdominal obesity was defined as a male waist circumference of more than 90 cm. An increase in the serum uric acid and serum CGT levels of the male subjects was defined as 7.0 mg/dL or more and 56 IU/L or more, respectively. The results showed that the serum GGT and uric acid levels were higher in the overweight and obese groups than in the normal weight group. In the obese group, the serum GGT and uric acid were significantly higher in the patients with abdominal obesity. On the other hand, there was no difference compared to the low body weight group. The overweight and obesity groups showed a higher risk of elevated serum GGT and hyperuricemia than the normal weight group, but a low body weight did not affect the serum GGT elevation and hyperuricemia. Overall, the serum GGT and uric acid levels are useful for evaluating overweight and obesity in adult males.

Effects of γ-Irradiation from Cobalt-60 on Immunogenicity of Eimeria tenella (Cobalt-60 γ-선 조사가 Eimeria tenella 의 면역원성에 미치는 영향)

  • Youn, Hee-jeong;Kang, Yung-bai;Jang, Du-hwan
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.657-664
    • /
    • 1993
  • To reveal the immunogenicity of ${\gamma}-irradiated$ E tenella and its progeny, a series of experiments on the effects of Cobalt-to ${\gamma}-irradiation$ was performed. The SPF chickens inoculated with diffenrt doses of inoculum were challenged with $1{\times}10^5$ oocysts of virulent E tenella. The levels of 100 Gy ${\gamma}-irradiation$ from $^{60}Co$ and of inoculum with $1{\times}10^4$ oocysts were recognized as proper as immunogen by comparison of survival rates, body weight gains, blood in feces and lesion scores in the chickens. In these trials of challenge with virulent E tenella after inoculation with $1{\times}10^4$ oocysts of the ${\gamma}-irradiated$ E tenella and its progeny, the survival rates of the chickens challenged with the virulent E tenella after immunization with the 1st and the 3rd progeny groups of ${\gamma}-irradiated$ E tenella oocysts were higher(l00%) than that(87.0%) of the challenged control group. The signs of blood in feces and the lesion scores were seen markedly lower with the ourput of the smaller number of oocysts, i.e. OPG 103,900 and 25,800 in the groups of the 1st and the 3rd progeny, respectively, than those(OPG 1,658,900) of the challenged control group. The body weight gains of the 1st and the 3rd progeny groups, the 1st week and the 2nd week after challenge, were higher (2.6g and 155.4g, 11.6g and 168.9g respectively) than those(-85.8g and 63.6g, respectively) of the challenged control group, and the feed conversion ratios(FCR 3.28 and 2.96) of the 1st and the 3rd progeny groups were lower than that(FCR 5.60) of the groups challenged control group. The anticoccidial indices(70.5 and 93.9) of the groups challenged with the virulent oocysts of E tenella after immunization with the 1st and the 3rd progeny of the ${\gamma}-irradiated$ E tenella were significantly higher than that (ACI -81.9) of the challenged control group. It was thought that the immunogenicity of ${\gamma}-irradiated$ E tenella would be increase according to increase the number of generation passaged in chicken. That might be because of increasing the pathogenicity of ${\gamma}-irradiated$ E tenella according to increase the number of generation passaged in chicken.

  • PDF

Comparison treatment planning with the measured change the dose of each Junction section according to the error of setup CSI Treatment with Conventional, IMRT, VMAT (Conventional, IMRT, VMAT을 이용한 CSI 치료시, Setup 오차에 따른 각 Junction부의 선량변화측정을 통한 치료계획 비교)

  • Lee, Ho Jin;Jeon, Chang Woo;Ahn, Bum Suk;Yu, Sook Hyeon;Park, So Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.217-224
    • /
    • 2014
  • Purpose : Conventional, IMRT, at CSI treatment with VMAT, this study compare the treatment plan with dose changes measured at Junction field according to the error of Setup. Materials and Methods : This study established Conventional, the IMRT, VMAT treatment planning for CSI therapy using the Eclipse 10.0 (Eclipse10.0, Varian, USA) and chose person in Seoul National University Hospital. Verification plan was also created to apply IMRT QA phantom for each treatment plan to the film measurements. At this time, the error of Setup was applied to the 2, 4, 6mm respectively with the head and foot direction. ("+" direction of the head, "-" means that the foot direction.) Using IMRT QA Phantom and EBT2 film, was investigated by placing the error of Setup for each Junction. We check the consistency of the measured Film and plan dose distribution by gamma index (Gamma index, ${\gamma}$). In addition, we compared the error of Setup by the dose distribution, and analyzing the uniformity of the dose distribution within the target by calculating the Homogeneity Index (HI). Results : It was figured out that 90.49%-gamma index we obtained with film is agreement with film scan score and dose distribution of treatment plan. Also, depend on the dose distribution on distance, if we make the error of Setup 2, 4, 6mm in the head direction, it showed that 3.1, 4.5, 8.1 at $^*Diff$(%) of Conventional, 1.1, 3.5, 6.3 at IMRT, and 1.6, 2.5, 5.7 at VMAT. In the same way, if we make the error of Setup 2, 4, 6mm in the foot direction, it showed that -1.6, -2.8, -4.4 at $^*Diff$(%) of Conventional, -0.9, -1.6, -2.9 at IMRT, and -0.5, -2.2, -2.5 at VMAT. Homogeneity Index(HI)s are 1.216 at Conventional, 1.095 at IMRT and 1.069 at VMAT. Discussion and Conclusion : The dose-change depend on the error of Setup at the CSI RT(radiation therapy) using IMRT and VMAT which have advantages, Dose homogeneity and the gradual dose gradients on the Junction part is lower than that of Conventional CSI RT. This a little change of dose means that there is less danger on patients despite of the error of Setup generated at the CSI RT.

The Radioprotection Effect of Protaetia Brevitarsis Larvae Extracts on the Reproductive in Female Rats Irradiated Gamma Ray (감마선에 조사된 암컷 흰쥐의 생식기관에 대한 흰점박이꽃무지 유충 추출물의 방사선 방호효과)

  • Jeong, Geun-Woo;Joung, Do-Young;Kim, Chang-Ju;Lee, Ji-Eun;Jeong, Sang-Hyun;Kim, Hee-Jin;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.247-255
    • /
    • 2021
  • The purpose of this study was to examine the radiation protection effect of protaetia brevitarsis larvae extracts known as antioxidant food. In this study 90 female rats were clssified in to 5 groups: NC Group, PBE Group, IR Group, PBE+IR Group and IR+PBE Group. In IR Group, 7 Gy of Co-60 gamma ray was irradiated to SD rat and protaetia brevitarsis larvae extracts were administered orally at 200 mg/kg once a day for 14 days. And then on the 1 day, 7 days, 21 days later after irradiation, changes in blood cell component, superoxide dismutase(SOD) activity, spleen index, histopathological evaluation of the ovary and uterus were observed. As a result, the PBE+IR Group (p<0.01, p<0.05) and IR+PBE Group (p<0.01, p<0.01) showed a significantly radiation protection than the IR Group in lymphocyte and red blood cell on the 21 days. It was also confirmed that SOD activity of PBE+IR Group (p<0.01) and IR+PBE Group (p<0.01) was significantly increased than the IR Group. In spleen index, PBE+IR Group (p<0.05) and IR+PBE Group (p<0.01) showed a significantly recovery than the IR Group. In histopathological observation, PBE+IR Group in the ovary and PBE+IR, IR+PBE Group in the uterus showed less inflammatory reactions of cystoplasm than the IR Group. Based on These results, It is judged that protaetia brevitarsis larvae Extracts have radiation protection effect against blood and reproductive. It is expected to be useful for research of radiation protection agent.

Rice Yield Estimation Using Sentinel-2 Satellite Imagery, Rainfall and Soil Data (Sentinel-2 위성영상과 강우 및 토양자료를 활용한 벼 수량 추정)

  • KIM, Kyoung-Seop;CHOUNG, Yun-Jae;JUN, Byong-Woon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.25 no.1
    • /
    • pp.133-149
    • /
    • 2022
  • Existing domestic studies on estimating rice yield were mainly implemented at the level of cities and counties in the entire nation using MODIS satellite images with low spatial resolution. Unlike previous studies, this study tried to estimate rice yield at the level of eup-myon-dong in Gimje-si, Jeollabuk-do using Sentinel-2 satellite images with medium spatial resolution, rainfall and soil data, and then to evaluate its accuracy. Five vegetation indices such as NDVI, LAI, EVI2, MCARI1 and MCARI2 derived from Sentinel-2 images of August 1, 2018 for Gimje-si, Jeollabuk-do, rainfall and paddy soil-type data were aggregated by the level of eup-myon-dong and then rice yield was estimated with gamma generalized linear model, an expanded variant of multi-variate regression analysis to solve the non-normality problem of dependent variable. In the rice yield model finally developed, EVI2, rainfall days in September, and saline soils ratio were used as significant independent variables. The coefficient of determination representing the model fit was 0.68 and the RMSE for showing the model accuracy was 62.29kg/10a. This model estimated the total rice production in Gimje-si in 2018 to be 96,914.6M/T, which was very close to 94,470.3M/T the actual amount specified in the Statistical Yearbook with an error of 0.46%. Also, the rice production per unit area of Gimje-si was amounted to 552kg/10a, which was almost consistent with 550kg/10a of the statistical data. This result is similar to that of the previous studies and it demonstrated that the rice yield can be estimated using Sentinel-2 satellite images at the level of cities and counties or smaller districts in Korea.

Comparison of Radiation Adaptive Responses in Peripheral Lymphocytes of Patients Undergoing Tc-99m MDP and Tc-99m DTPA Scintigraphies (Tc-99m MDP와 Tc-99m DTPA 신티그라피를 시행한 환자의 말초혈액 림프구에서 유도되는 방사선 적응반응의 비교)

  • Bom, Hee-Seung;Li, Ming-Hao;Min, Jung-Jun;Kwon, An-Sung;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.252-259
    • /
    • 2000
  • Purpose: The purpose of this study was to compare the radiation adaptive response (RAR) in peripheral lymphocytes (PL) of patients induced by Tc-99m MDP and Tc-99m DTPA scintigraphies. Materials and Methods: Lymphocytes from 45 patients (25 males, 20 females, mean age $44{\pm}18$ years) were collected before and after scintigraphies using 740 MBq Tc-99m MDP (n=22) or Tc-99m DTPA (n=23). Lymphocytes from 20 controls (12 males, 8 females, mean age $43{\pm}7$ years) were also collected. They were exposed to challenge dose of 2 Gy ${\gamma}-rays$ using a Cs-137 cell irradiator Number of ring-form (R) and dicentric (D) chromosomes was counted under the light microscope. From them a representative score, Ydr, was calculated as Ydr=(D+R)/cells. Adaptation index (AI) was defined as difference of Ydr between unconditioned and conditioned lymphocytes. Ydr was also measured after an administration of cycloheximide (CHM), a protein synthesis inhibitor, before challenge dose. Results: RAR was induced in both groups of patients. CHM abolished the adaptive response in both groups. AI of Tc-99m MDP group was significantly higher than that of Tc-99m BTPA group. Conclusion: Tc-99m MDP induced RAR was more prominent than those induced by Tc-99m DTPA.

  • PDF

Determination of Appropriate Sampling Frequency and Time of Multiple Blood Sampling Dual Exponential Method with $^{99m}Tc$-DTPA for Calculating GFR (사구체여과율 계산을 위한 $^{99m}Tc$-DTPA를 이용한 다중 채혈 이중지수법의 적정 채혈 횟수 및 시간의 선정)

  • Kim, Chung-Ho;O, Joo-Hyun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • Purpose: To determine appropriate sampling frequency and time of multiple blood sampling dual exponential method with $^{99m}Tc$-DTPA for calculating glomerular filtration rate (GFR). Materials & Methods: Thirty four patients were included in this study. Three mCi of $^{99m}Tc$-DTPA was intravenously injected and blood sampling at 9 different times, 5ml each, were done. Using the radioactivity of serum, measured by gamma counter, the GFR was calculated using dual exponential method and corrected with the body surface area. Using spontaneously chosen 2 data points of serum radioactivity, 15 collections of 2-sample GFR were calculated. And 10 collections of 3-sample GFR and 12 collections of 4-sample GFR were also calculated. Using the 9-sample GFR as a reference value, degree of agreement was analyzed with Kendall's $\tau$ correlation coefficients, mean difference and standard deviation. Results: Although some of the 2-sample GFR showed high correlation coefficient, over or underestimation had evolved as the renal function change. The 10-120-240 min 3-sample GFR showed a high correlation coefficient (${\tau}=0.93$), minimal difference ($Mean{\pm}SD=-1.784{\pm}3.972$), and no over or underestimation as the renal function changed. The 4-sample GFR showed no better accuracy than the 3-sample GFR. Conclusions: In the wide spectrum of renal function, the 10-120-240 min 3-sample GFC could be the best choice for estimating the patients' renal function.

Development of the Monte Carlo Simulation Radiation Dose Assessment Procedure for NORM added Consumer Adhere·Non-Adhere Product based on ICRP 103 (ICRP 103 권고기반의 밀착형·비밀착형 가공제품 사용으로 인한 몬테칼로 전산모사 피폭선량 평가체계 개발)

  • Go, Ho-Jung;Noh, Siwan;Lee, Jae-Ho;Yeom, Yeon-Soo;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Radiation exposure to humans can be caused by the gamma rays emitted from natural radioactive elements(such as uranium, thorium and potassium and any of their decay products) of Naturally Occurring Radioactive Materials(NORM) or Technologically Enhanced Naturally Occurring Radioactive Materials(TENORM) added consumer products. In this study, assume that activity of radioactive elements is $^{238}U$, $^{235}U$, $^{232}Th$ $1Bq{\cdot}g^{-1}$, $^{40}K$ $10Bq{\cdot}g^{-1}$ and the gamma rays emitted from these natural radioactive elements radioactive equilibrium state. In this study, reflected End-User circumstances and evaluated annual exposure dose for products based on ICRP reference voxel phantoms and ICRP Recommendation 103 using the Monte Carlo Method. The consumer products classified according to the adhere to the skin(bracelet, necklace, belt-wrist, belt-ankle, belt-knee, moxa stone) or not(gypsum board, anion wallpaper, anion paint), and Geometric Modeling was reflected in Republic of Korea "Residential Living Trend-distributions and Design Guidelines For Common Types of Household.", was designed the Room model($3m{\times}4m{\times}2.8m$, a closed room, conservatively) and the ICRP reference phantom's 3D segmentation and modeling. The end-user's usage time assume that "Development and Application of Korean Exposure Factors." or conservatively 24 hours; in case of unknown. In this study, the results of the effective dose were 0.00003 ~ 0.47636 mSv per year and were confirmed the meaning of necessary for geometric modeling to ICRP reference phantoms through the equivalent dose rate of belt products.

Option Pricing Models with Drift and Jumps under L$\acute{e}$vy processes : Beyond the Gerber-Shiu Model (L$\acute{e}$vy과정 하에서 추세와 도약이 있는 경우 옵션가격결정모형 : Gerber-Shiu 모형을 중심으로)

  • Cho, Seung-Mo;Lee, Phil-Sang
    • The Korean Journal of Financial Management
    • /
    • v.24 no.4
    • /
    • pp.1-43
    • /
    • 2007
  • The traditional Black-Scholes model for option pricing is based on the assumption that the log-return of the underlying asset follows a Brownian motion. But this assumption has been criticized for being unrealistic. Thus, for the last 20 years, many attempts have been made to adopt different stochastic processes to derive new option pricing models. The option pricing models based on L$\acute{e}$vy processes are being actively studied originating from the Gerber-Shiu model driven by H. U. Gerber and E. S. W. Shiu in 1994. In 2004, G. H. L. Cheang derived an option pricing model under multiple L$\acute{e}$vy processes, enabling us to adopt drift and jumps to the Gerber-Shiu model, while Gerber and Shiu derived their model under one L$\acute{e}$vy process. We derive the Gerber-Shiu model which includes drift and jumps under L$\acute{e}$vy processes. By adopting a Gamma distribution, we expand the Heston model which was driven in 1993 to include jumps. Then, using KOSPI200 index option data, we analyze the price-fitting performance of our model compared to that of the Black-Scholes model. It shows that our model shows a better price-fitting performance.

  • PDF