• Title/Summary/Keyword: 간 초음파영상

Search Result 232, Processing Time 0.056 seconds

US Attenuation Imaging for the Evaluation and Diagnosis of Fatty Liver Disease (지방간 질환 진단을 위한 초음파 감쇠 영상 평가)

  • Seung Jun Lee;Youe Ree Kim;Young Hwan Lee;Kwon-Ha Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.666-675
    • /
    • 2023
  • Purpose This study aimed to determine whether the attenuation coefficient (AC) from attenuation imaging (ATI) was correlated with visual US assessment in patients with hepatic steatosis. Moreover, it aimed to assess whether the patient's blood chemistry results and CT attenuation were correlated with AC. Materials and Methods Patients who underwent abdominal US with ATI between April 2018 and December 2018 were included in this study. Patients with chronic liver disease or cirrhosis were excluded. The correlation between AC and other parameters, such as visual US assessment, blood chemistry results, liver attenuation, and liver-to-spleen (L/S) ratio, were analyzed. AC values according to visual US assessment grades were compared using analysis of variance. Results A total of 161 patients were included in this study. The correlation coefficient between US assessment and AC was 0.814 (p < 0.001). The mean AC values for the normal, mild, moderate, and severe grades were 0.56, 0.66, 0.74, and 0.85, respectively (p < 0.001). Alanine aminotransferase levels were significantly correlated with AC (r = 0.317, p < 0.001). The correlation coefficients between liver attenuation and AC and between L/S ratio and AC were -0.702 and -0.626, respectively (p < 0.001). Conclusion Visual US assessment and AC showed a strong positive correlation with the discriminative value between the groups. Computed tomography attenuation and AC showed a strong negative correlation.

The Convergence Study on the Effects of Three Pelvic Floor Muscle Excercise on Thickness of Pelvic Floor Muscle and Abdominal Muscles (골반바닥근 운동방법이 골반바닥근과 몸통근육의 근두께에 미치는 영향에 대한 융합적 연구)

  • Kang, Si-Eun;Shim, Jae-Hoon;Choung, Sung-Dae
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.1
    • /
    • pp.105-111
    • /
    • 2016
  • The purpose of this study was to investigate effects of three pelvic floor muscle (PFM) exercises on the thickness of PFM and transverse abdominal muscle (TrA), the internal oblique muscle, and the external oblique muscle. The PFM and trunk muscles were measured using ultrasonography in 4 conditions.rest, conventional PFM contraction (Ex A), PFM contraction with hip adductor contraction (Ex B), and PFM contraction with real-time ultrasound imaging (Ex C). The thickness of PFM in Ex C showed a significantly more decrease compared to rest and others (all comparisons, p<.05). The thickness of TrA in Ex C showed a significantly more increase compared to rest and others (all comparisons, p<.05). This study would recommend the use of PFM contraction with real-time ultrasonographic imaging to improve women's incontinence.

Adaptive quantization for effective data-rate reduction in ultrafast ultrasound imaging (초고속 초음파 영상의 효과적인 데이터율 저감을 위한 적응 양자화)

  • Doyoung Jang;Heechul Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.422-428
    • /
    • 2023
  • Ultrafast ultrasound imaging has been applied to various imaging approaches, including shear wave elastography, ultrafast Doppler, and super-resolution imaging. However, these methods are still challenging in real-time implementation for three Dimension (3D) or portable applications because of their massive data rate required. In this paper, we proposed an adaptive quantization method that effectively reduces the data rate of large Radio Frequency (RF) data. In soft tissue, ultrasound backscatter signals require a high dynamic range, and thus typical quantization used in the current systems uses the quantization level of 10 bits to 14 bits. To alleviate the quantization level to expand the application of ultrafast ultrasound imaging, this study proposed a depth-sectional quantization approach that reduces the quantization errors. For quantitative evaluation, Field II simulations, phantom experiments, and in vivo imaging were conducted and CNR, spatial resolution, and SSIM values were compared with the proposed method and fixed quantization method. We demonstrated that our proposed method is capable of effectively reducing the quantization level down to 3-bit while minimizing the image quality degradation.

Clinical Efficacy of Real-Time Sonoelastography for the Follow-Up of Congenital Sternocleidomastoid Muscle Torticollis (선천성 근육성 사경의 추적검사에서 실시간 탄성초음파 검사의 임상적 유용성)

  • Mi ri Jeong;In Sook Lee;Yong Beom Shin;You Seon Song;Sekyoung Park;Jong Woon Song;Jin Il Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.176-189
    • /
    • 2020
  • Purpose To evaluate the clinical efficacy of real-time sonoelastography (RTS) for the follow-up of congenital muscular torticollis, based on measurements of muscle elasticity. Materials and Methods Thirty-four infants (23 male, 11 female) with congenital sternocleidomastoid (SCM) muscle torticollis underwent ultrasonography and elastography between November 2012 and December 2014. We evaluated the thickness, morphology (mass-like, fusiform, or overall thickened shape), and echogenicity of the SCM muscle on grayscale images and color patterns (homogeneous blue, mixed green < 50% and ≥ 50%, and green to red) on elastography. Strain ratios were measured using Q-lab software. A clinician classified the degree of neck rotation and side flexion deficits using a 5-point grade system based on angles of neck rotation and side flexion. Correlations between the ultrasonography and clinical findings were evaluated by statistical analysis. Results Twenty-two infants had right and 12 had left SCM torticollis, respectively. Linear regression analysis showed that involved/contralateral SCM thickness differences, morphology, elasticity color scores, and strain ratios of the affected SCM muscles were significantly correlated with neck rotation and side flexion deficit scores (p < 0.05). The elasticity color score of the affected SCM muscle was the most significant factor. Conclusion RTS might provide a reliable means for evaluating and monitoring congenital muscular torticollis.

GLCM Algorithm Image Analysis of Nonalcoholic Fatty Liver and Focal Fat Sparing Zone in the Ultrasonography (초음파검사에서 비알콜성 지방간과 국소지방회피영역에 대한 GLCM Algorithm 영상분석)

  • Cho, Jin-Young;Ye, Soo-Young
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.205-211
    • /
    • 2017
  • There is a need for aggressive diagnosis and treatment in middle-aged and high-risk individuals who are more likely to progress from nonalcoholic fatty liver to hepatitis. In this study, nonalcoholic fatty liver was divided into severe, moderate, and severe, and classified by quantitative method using computer analysis of GLCM algorithm. The purpose of this study was to evaluate the characteristics of ultrasound images in the local fat avoidance region. Normal, mild, moderate, severe fatty liver, and focal fat sparing area, 80 cases, respectively. Among the parameters of the GLCM algorithm, the values of the Autocorrelation, Square of the deviation, Sum of averages and Sum of variances with high recognition rate of the liver ultrasound image were calculated. The average recognition rate of the GLCM algorithm was 97.5%. The result of local fat avoidance image analysis showed the most similar value to the normal parenchyma. Ultrasonography can be easily accessed by primary screening, but there may be differences in the accuracy of the test method or the correspondence of results depending on proficiency. GLCM algorithm was applied to quantitatively classify the degree of fatty liver. Local fat avoidance region was similar to normal parenchyma, so it could be predicted to be homogeneous liver parenchyma without fat deposition. We believe that GLCM computer image analysis will provide important information for differentiating not only fatty liver but also other lesions.

Evaluation of Stage of Liver Fibrosis by Ultrasonography : Based on Pathologic Results of Biopsy (초음파검사를 통한 간 섬유화 병기단계 평가 : 조직검사결과 기준으로)

  • An, Hyun;Lee, Hyo-Yeong;Im, In Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.547-555
    • /
    • 2019
  • The purpose of this study was to evaluate the usefulness of routine liver ultrasonography on the basis of the scoring system according to the morphological parameters of liver ultrasound images and the histopathological results of liver biopsy. The morphological parameters of the liver through ultrasonography were divided into liver surface, liver edge and liver parenchyma. Pathologic results of liver biopsy were classified as mild fibrosis(F1), significant fibrosis(F2), severe fibrosis(F3), and cirrhosis(F4). In conclusion, routine ultrasound examination showed a sensitive predictive factor for fibrosis with mild fibrosis (F1) to severe fibrosis (F3) were liver edge>liver parenchyma>liver surface. However, the predictive factors for detecting cirrhosis (F4) were liver parenchyma>liver surface>liver edge. The use of three variable combinations rather than individual variables in routine ultrasonography may be useful in evaluating the degree and progress of liver fibrosis.

Implementation of a backend system for real-time intravascular ultrasound imaging (실시간 혈관내초음파 영상을 위한 후단부 시스템 구현)

  • Park, Jun-Won;Moon, Ju-Young;Lee, Junsu;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.215-222
    • /
    • 2018
  • This paper reports the development and performance evaluation of a backend system for real-time IVUS (Intravascular Ultrasound) imaging. The developed backend system was designed to minimize the amount of logic and memory usage by means of efficient LUTs (Look-up Tables), and it was implemented in a single FPGA (Field Programmable Gate Array) without using external memory. This makes it possible to implement the backend system that is less expensive, smaller, and lighter. The accuracy of the backend system implemented was evaluated by comparing the output of the FPGA with the result computed using a MATLAB program implemented in the same way as the VHDL (VHSIC Hardware Description Language) code. Based on the result of ex-vivo experiment using rabbit artery, the developed backend system was found to be suitable for real-time intravascular ultrasound imaging.

A Parametric Imaging Technique for Characterizing Focal Liver Lesions in Contrast-Enhanced Ultrasound (간 병변 분석을 위한 조영증강 초음파 데이터의 영상화기법)

  • Park, So-Jeong;Sung, Myung-Chul;Lee, Seung-Kang;Kim, Ho-Joon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.369-372
    • /
    • 2012
  • 조영증강 의료 초음파 영상에서 조영제의 확산효과에 대한 분석은 간질환과 연관된 각종 병변을 검출하고 분석하는 과정에서 매우 유용한 정보를 제공한다. 본 연구에서는 초음파 영상에서 조영제의 확산 패턴을 분석하고 이를 영상화하는 방법을 제안한다. 이 과정에서 부수적으로 호흡에 의한 흔들림 현상을 보정하고 노이즈의 영향을 극복할 수 있는 방법론을 고찰한다. 호흡주기에 따른 모멘텀 요소를 고려한 ROI 추적 기법은 측정과정에서의 흔들림과 노이즈에 의한 오류를 최소화 할 수 있게 한다. 조영제의 확산 단계에 따라 서로 다른 노이즈 비율을 고려하여 동적 가중치를 할당하는 방법으로써 흔들림을 보정하였으며, 조영제의 전이 시간과 패턴을 분석하고 그 특성을 분류함으로써 간 병변 분석을 위한 효과적인 영상화기법을 구현하였다. 또한 생성된 영상에서 노이즈를 제거하고 영상을 개선하는 방법으로서 MRF 기반의 최적화 알고리즘을 적용하는 영상 개선 기법을 제시한다.

Image Magnification using Fuzzy Method for Ultrasound Image of Abdominal Muscles (복부 초음파 영상에서의 퍼지 기법을 이용한 영상 확대)

  • Kim, Kwang-Baek;Lee, Hae-Jung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.4
    • /
    • pp.23-28
    • /
    • 2011
  • Ultrasound images for the abdominal muscles are complicated enough to have difficulty in interpreting their results. For better interpretation, magnifying the original image is necessary but its magnified image could be deteriorated and suffer from information loss. Thus, in this paper, we propose a magnifying method that reduces the gap between the original image and the magnified one in quality using a fuzzy method with weights for its brightness and interpolation. The proposed method extracts information of pixels in magnified image that have most similar characteristics of the original one by applying fuzzy membership function. In the process, the difference in the brightness between pixels of the magnified image and the original one using bilinear interpolation method and the weight value using the interpolation from multiplied values of four pixels are supplied to the fuzzy membership function. In this experiment, the proposed method reduces the cloudy phenomenon appears commonly compared to the bilinear interpolation method among those qualitative issues of image interpretation.

A GPU-based Filter Algorithm for Noise Improvement in Realtime Ultrasound Images (실시간 초음파 영상에서 노이즈 개선을 위한 GPU 기반의 필터 알고리즘)

  • Cho, Young-Bok;Woo, Sung-Hee
    • Journal of Digital Contents Society
    • /
    • v.19 no.6
    • /
    • pp.1207-1212
    • /
    • 2018
  • The ultrasound image uses ultrasonic pulses to receive the reflected waves and construct an image necessary for diagnosis. At this time, when the signal becomes weak, noise is generated and a slight difference in brightness occurs. In addition, fluctuation of image due to breathing phenomenon, which is the characteristic of ultrasound image, and change of motion in real time occurs. Such a noise is difficult to recognize and diagnose visually in the analysis process. In this paper, morphological features are automatically extracted by using image processing technique on ultrasound acquired images. In this paper, we implemented a GPU - based fast filter using a cloud big data processing platform for image processing. In applying the GPU - based high - performance filter, the algorithm was run with performance 4.7 times faster than CPU - based and the PSNR was 37.2dB, which is very similar to the original.