• Title/Summary/Keyword: 간극이론

Search Result 188, Processing Time 0.03 seconds

Analysis of Wave Velocity for Temperature Propagation in a Mechanical Face Seal (기계평면 시일에서 온도전파를 위한 파속도의 이론적해석)

  • 김청균
    • Tribology and Lubricants
    • /
    • v.3 no.2
    • /
    • pp.64-67
    • /
    • 1987
  • 미끄럼 운동에 의하여 미세한 시일링 간극에 열이 발생할 때 어떠한 빠르기로 발생된 열이 재질 내부로 전파되는가를 속도의 개념으로 이론적 해석을 하였다. 발생된 마찰열이 시일재질 내부로 전파되는 속도는 불안정한 온도의 파장에 의하여 커다란 영향을 받고 있다.

Method for the Evaluation of Strength Parameter from the Void Ratio of Decomposed Granite Soil after Compaction Using Preconsolidation Theory (선행압축이론을 이용한 화강풍화토의 다짐 후의 간극비로부터 지반강도정수 추정 방법)

  • Ham, Tae-Gew
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.6
    • /
    • pp.89-99
    • /
    • 2009
  • In order to clarify the relation between the physical properties and the strength parameters of compaction materials and to develop a method for evaluating the strength parameters required for design from the physical indices including void ratio and dry density, compaction test, one-dimensional compression test, and exhausted-drained triaxial compression test were carried out with decomposed granite soils. The test results showed that the specimens became over-consolidated by compaction and the increase of the strength parameters of the specimens by the increase of the compaction energy could be verified quantitatively. A method for the evaluation of strength parameters from the void ratio of soil after compaction using preconsolidation theory which evaluates over-consolidation of materials was developed and its engineering applicability was tested for verification.

Permeability Reduction of Soil Filters due to Physical Clogging (물리적 폐색으로 인한 흙필터의 투수능 저하)

  • ;;;;Reddi, L. N.
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.1
    • /
    • pp.15-24
    • /
    • 2001
  • 흙필터는 일반적으로 침식이나 파이핑으로부터 지반 구조물을 보호하기 위하여 사용된다. 세립자들이 유동하여 필터에 퇴적하는 폐색현상이 발생하는 경우, 간극수압이 증가하고 이로 인해 지반구조물의 불안정을 유발시키게 된다. 미세입자의 유동에 의한 폐색현상은 옹벽의 뒤채움재에 설치한 필터, 흙댐의 저부에 설치된 필터, 그리고 터널의 라이닝 뒤에 설치한 필터 등에서 발생할 수 있다. 폐색현상은 필터의 투수능을 저하시켜 배수능력에 상당한 위험을 초래할 수 있다. 본 연구에서는 필터의 폐색으로 인한 투수능 저하 정도를 실험을 통해 관찰하고 이론적인 모델을 통해 정량화 시키고자 하였다. 일정한 농도의 현탁액이 필터로 유입되는 분리형 실험과 현장상태를 모사하는 흙-필터 시스템의 결합형 실험을 통해 투수능의 저하현상이 압력 제어조건과 유량 제어조건에서 관찰되었고, 서로 비교 분석되었다. 미세입자가 통과하는 필터의 간극을 모세관으로 가정한 후 모세관에서 유체의 흐름 원리를 이용하여 물리적인 폐색에 의해 발생하는 투수능 저하현상을 이론적인 모델로 구성하였다. 일반적으로 투수능은 1/10 수준으로 감소되었으며, 분리형 실험에 의한 결과와 이론적인 모델의 결과는 잘 일치하였다. 또한, 결합형 실험결과와 분리형 실험결과가 비교적 잘 일치하여 투수능 저하예측은 분리형 실험이나 이론적 모델에 의하여 가능하리라 판단되었다.

  • PDF

Analysis of Mechanical Face Seals for Design Purpose Geometric Effects on sealing Gap (설계목적을 위한 기계 평면 시일의 해석 제1보:시일링 간극에 대한 기하학적 영향에 관하여)

  • 김청균
    • Tribology and Lubricants
    • /
    • v.6 no.1
    • /
    • pp.89-98
    • /
    • 1990
  • 시일의 접촉면이 경사지고, 정현파형이 존재하며 코닝이 있는 경우에 대한 해석을 하였다. 또한 시일링 간극에 존재하는 유체는 비압축성 점성유체이다. 이러한 요소들을 고려한 레이놀즈 방정식의 일반해를 구하기 위하여 멱급수 근사이론을 이용하여 압력분포를 구하였고, 이 결과를 이용하여 시일의 누설 유동량 및 마찰 토오크를 해석하였다. 계산 결과에 의하면 시일 접촉면의 표면파형이나 코닝에 비하여 경사정도가 시일의 성능에 커다란 영향을 주고 있음을 보여주고 있다.

Estimation of Discharge Current Waveshapes in Short Gap Discharge by One Antennal Method (1 안테나 법에 의한 미소 간극의 방전 전류파형 추정)

  • 김기채;이광식;이동인
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.499-505
    • /
    • 1998
  • This paper presents the method for an estimation of discharge current waveshapes in short gap discharge by a radiated electromagnetic field. The method of currentwaveform estimation described is using the one antenna method(single field method) with a measured electric or magnetic fields at given field point by a time domain antenna. In order to verify the availability of the estimated theory, the discharge current waveshape estimation was performed by one antenna method using the measured electric fields of Wilson & Ma and compared with experiments.

  • PDF

A Study on the Effect of a Gap in Measurement of Underwater Transmission Loss by Pulse Tube (펄스 튜브를 이용한 수중 전달 손실 측정에서 간극이 미치는 영향에 대한 고찰)

  • Seo, Yun-Ho;Kim, Sang-Ryul;Kim, Jae-Seung;Byun, Yang-Heon;Seo, Youngsoo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.3
    • /
    • pp.192-199
    • /
    • 2015
  • There is a gap between the inner wall of a pulse tube and an underwater acoustic material when the measurement for transmission loss by the pulse tube is carried out. In this paper, the effect, which is caused by the gap, for the measurement of transmission loss is analyzed. Transmission coefficient is derived from the ratio of the pressures between front and rear of the gap. Then, transmission loss for specimen with a gap is obtained by combining the transmission coefficients of the gap and specimen. The results of experiment and simulation for a specimen of stainless steel with 10 mm thickness are compared in order to evaluate the simulation model. Finally, simulations with respect to the gap size and transmission loss of a specimen are performed to analyze and evaluate the effect of the gap in measurement of transmission loss.

Porous Medium Theory in Consolidation (다공체 이론과 입밀해석)

  • Seo, Young-Kyo
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.108-112
    • /
    • 2002
  • 다공체 이론은 간극수압 및 토질입자 및 간극수의 상호 작용을 포함하는 여러 가지 지반관련 문제의 이해에 있어 매우 중요하다. 이러한 상호작용은 토질강도 및 변형에 중요한 영향을 미친다. 본 논문은 다공체 이론(porous medium theory)의 일반식 및 구성모델을 제시하고 그에 따른 유한요소 공식을 유도하였다. 압밀 예제로서 이러한 모델의 정확도를 검증하였다.

  • PDF

Behavior of cement-based permeation grouting in cohesionless soil considering clogging phenomena (폐색효과를 고려한 사질토의 시멘트 침투 그라우팅 거동 특성)

  • Seo, Jong-Woo;Lee, In-Mo;Kim, Byung-Kyu;Kwon, Young-Sam
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.485-500
    • /
    • 2018
  • The behavior of cement-based permeation grouting is divided into three different groups depending on the grain size distribution of the soils: (1) zone of cement-based permeation grouting not feasible; (2) zone of cement-based permeation grouting feasible; and (3) zone in which an accelerating agent should be added to limit the penetration depth. In the cement-based permeation grouting feasible zone, the concept of a representative pore radius was proposed. The ratios of the representative pore radius to the mean pore radius were obtained by performing laboratory test and comparing with clogging theory; these values were in the range of 1.07 and 1.35 depending on the grain size distribution of the soils. In addition, a functional relationship between the lumped parameter (${\theta}$), the representative pore radius and the w/c ratio were derived by comparing and matching experimental results with predictions from theory. In the zone in which the accelerating agent should be added, the controlling process of gel time to limit the penetration depth was experimentally verified. The test results matched well with those obtained from theory utilizing the developed grout penetration program on condition that the viscosity increasing tendency of grout suspension with time is properly taken into account.

Estimating the Coefficient of Consolidation of Marine Clay Using Piezocone Penetration Tests (피에조 콘 시험을 이용한 점성토의 압밀계수 추정)

  • 박용원;구남실;이상익
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.311-320
    • /
    • 2003
  • The coefficient of consolidation of clay deposit is one of the most important properties in the design of ground improvement. The in-situ value of $c_h$ is generally estimated by pore pressure dissipation using piezocone. Many researchers have suggested theoretical formula for its estimation. This study attempts to find out the validity of the existing theoretical formula in Korea and to find out the characteristics of $c_h$ related to the mechanical properties of clay. Piezocone tests and laboratory tests were performed at the site of pilot project of ground improvement at Yangsan-Mulgeum, Gyeongnam. Comparison of the estimated values of $c_h$using piezocone tests results and those from laboratory consolidation tests are carried out. Results show that Torstensson(cylindrical cavity theory) and Teh & Houlsby solutions derive similar values of $c_h$. And $c_h$ from oedometer test shows values similar to the above two methods. The value from either of the above two methods[Torstensson(cylindrical) or Teh & Houlsby] is recommended to be used as $c_h$.