• Title/Summary/Keyword: 가열파이프

Search Result 35, Processing Time 0.021 seconds

Experimental Investigation of Flow Assurance due to Heating Method in Offshore Pipeline (해양플랜트 파이프라인 가열방식에 따른 유동 안정성 실험 연구)

  • Sohn, Sangho;Park, Jaebum;Lee, Jungho
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.1
    • /
    • pp.45-53
    • /
    • 2015
  • The fact that gas hydrate and/or paraffin wax is frequently plugged in offshore pipeline has been become very significant for offshore piepline flow assurance. An active electrical heating along pipeline has adapted in resolving flow assurance problem like as gas hydrate and wax plugging. This study represents a novel internal-swirled heater which was designed and fabricated for more effective heating and thermal mixing through pipeline. The internal-swirled heater suggested in this study shows higher thermal mixing performances than the conventional external-traced heater.

Critical Heat Flux and Working Fluid Quantity in Thermosiphon Heat Pipe (써모싸이폰 히트파이프에서 열수송한계와 최적작동유체 주입량에 관한 연구)

  • 이기우
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.10a
    • /
    • pp.193-208
    • /
    • 1998
  • 본 논문에서는 써모싸이폰식 히트파이프의 열수송한계와 작동유체의 주입량이 파이프의 직경, 가열량 및 증발부와 응축부의 길이비 등에 따라 변화하므로 이러한 인자에 따른 적정 작동유체의 주입량과 가열량의 한계에 대해 고찰하였다. 특히 각종 전자부품의 냉각에 사용되는 히트파이프가 써모사이폰식이므로 사용작동유체에 대해 가열량에 따라 파이프의 직경예측이 가능토록 열수송한계특성에 대해 검토하고, 싸이리스터용은 증발부와 응축부의 길이비 변동이 심하므로 작동유체의 주입량이 중요한 성능인자로 작용하므로 길이비에 따른 작동유체의 주입량범위에 대해 기술하였다. 그리고 최적의 작동유체범위와 히트파이프의 증발열전달계수 및 응축열전달계수에 대한 실험으로부터 성능자료를 도출하여 이론해석과 비교검토하였다.

  • PDF

Innovative Transient Thermal Gradient Control to Prevent Early Aged Cracking of Massive Concrete (매스콘크리트의 열경사 조절에 의한 수화열과 온도균열의 방지)

  • Kim, Seong-Soo;Cho, Tae-Jun;Lee, Jeong-Bae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.164-172
    • /
    • 2008
  • The heat of hydration for early aged mass concrete induces high temperature with the hydration. Control of the temperature difference across a section is an effective strategy to minimize the hydration heat induced cracks for the structures where internal restraint is dominant. The current prevention methods for hydration cracking show some limitations for the control of thermal gradients, and these limitations could make micro and macro cracks in surface and core of concrete. Especially cooling methods can decrease the increasing hydration temperature, but it can not prevent the problem while decreasing temperature. Consequently heating pipes are added simultaneously with the cooling pipes in order to control the temperature gradients between core and surface of the concrete, followed by the finite element analysis (FEA). Based on the FEA, the proposed method using cooling pipe and heating pipes together has been found to be an effective alternative in thermal gradient control, in terms of controlling temperature induced cracks significantly.

Heat transfer characteristics of the heat pipe using simplified heat transfer model (단순 열전달 모델을 이용한 히트파이프의 열전달 성능특성에 관한 연구)

  • Seo, Jae-Hyeong;Bang, Yu-Ma;Seo, Lee-Soo;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.15-20
    • /
    • 2015
  • The objective of this study was to examine numerically the heat transfer and flow characteristics of the heat pipe with a wick using the simplified heat transfer model to enhance the cooling effects of high heat flux devices and minimizing the energy consumption for electric vehicles. The heat pipe with a wick was analyzed using commercial software with COMSOL and water was used as the working fluid. The velocity and temperature characteristics of the heat pipe were simulated numerically along the heat pipe and the local and average Nusselt numbers were calculated. As a result, the driving force occurred because of the temperature difference between the hot side and the cold side. The heat transfer of the heat pipe occurred from the hot side to the cold side and increased toward the center position. In addition, the average Nusselt numbers were 1.88 for the hot side and 0.1 for the cold side, and the maximum Nusselt number was 4.47 for the hot side and 0.7 for the cold side.

Development of Pipe-Inserted Cast Die for Press Forming Process Using Ansys and LabView (Ansys와 LabView를 이용한 프레스 성형용 파이프 인서트 주조금형 개발)

  • Lho, Tae-Jung;Choi, Hyeon-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3559-3566
    • /
    • 2009
  • Heating and cooling plate are separately used for heating and cooling cast dies for footwear parts. However, this has a disadvantage that it takes a long time to manufacture footwear parts etc.. In the present study, the pipe-inserted cast die for press forming process was proposed to substitute heating and cooling plate. The temperature distribution on the pipe-inserted cast die was analyzed by numerical work using a FEM. And its temperature was measured by LabView. A manufacturing by the pipe-inserted cast die for press forming process was effectively verified, especially in a productivity.

A Study on the Thermal Response Characteristics of Snow Removing Facilities using Heat Pipe (히트파이프식 제설설비의 열응답 특성에 관한 연구)

  • Lee, Yong-Soo;Jang, Yeong-Suk
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.45-56
    • /
    • 1997
  • The purpose of this research was to study the characteristics of heat transfer of snow removing facilities using heat pipe by experimental method. Heat pipes was constructed a flexible tube connected between evaporator and condenser ends for altitude adjustment of evaporator and it was constituted an internal diameter of 25.4mm, a length of 950mm for heating section and a length of 6000mm for condenser section with copper material for closed system. The results showed that the effect of heat transfer was increased when inclination angle and inlet temperature of heating water increased. Wall temperature response by inclined angle $4.5^{\circ}c-9^{\circ}c$ and working fluid amount 0.96 from to 1.3 times of evaporator volume were better than those of other working fluid and angle.

  • PDF

Program for Process and System Design of Continuous Sterilizer (연속살균 공정 및 장치 설계 프로그램 개발)

  • 김형욱;홍지향;고학균
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.395-400
    • /
    • 2002
  • 지역농가, 농협 단위로 그 지역에서 생산되는 특산물을 직접 살균 가공할 수 있는 연속살균공정과 장치를 설계할 수 있는 프로그램을 웹프로그래밍 언어의 일종인 JSP와 자바를 이용하여 개발하였다. 식품의 산성도 및 물리적 특성과 미생물의 내열특성 등 공정을 설계하는 데 필요한 전문적인 정보를 데이터베이스로 구축하여 사용자가 식품의 특성에 대해 자세하게 모르더라도 쉽게 식품의 살균공정을 설계할 수 있었다. 연속살균장치를 구성하고 있는 부분은 크게 열교환기와 가열유지관, 펌프이며, 이에 대한 설계를 장치 설계 프로그램에서 하였다. 열교환기, 가열유지관등의 설계는 장치의 생산량 및 가격등을 결정하는 주요 요소이며, 살균장치의 성능을 결정짓는 주요한 인자가 된다. 연속살균공정을 설계하는 데 필요한 인자는 식품의 pH특성, 식품의 종류이며, 입력된 값을 이용하여 데이터베이스 내에서 살균할 미생물의 종류와 미생물의 내열특성을 찾아 살균공정을 계산하게 된다. 프로그램을 통해 살균가능한 온도와 시간을 출력한다. 연속살균장치 설계 프로그램의 입력인자는 식품의 살균온도, 식품의 생산량, 열교환기에 사용할 열매체의 종류이며, 프로그램 내에서 열교환기의 전열계수, 식품을 살균온도가지 가열하는 데 걸리는 시간등이 계산되며, 결과값으로 열교환기의 특성 및 파이프의 구경과 길이, 펌프의 용량, 단열관의 구경과 길이가 출력된다. 살균 장치 중 열교환기의 설계에 사용되는 스테인레스 파이프를 국내에서 사용되는 규격별로 데이터베이스화하였으며, 파이프 제작업체 48개 업체, 펌프 제작업체 54개(국내 15개 업체, 미국 39개 업체), 열교환기 제작업체 13개업체(국내 13개 업체)에 대해서 데이터베이스를 구축하여 프로그램을 사용해 설계된 장치를 사용자가 쉽게 제작할 수 있도록 하였다. 공정설계프로그램을 통해 설계된 공정은 데이터베이스에 저장이 되며 장치설계프로그램에서 쉽게 이전에 설계했던 공정을 이용할 수 있도록 하여 공정 설계와 장치설계를 연계하도록 하였다.

  • PDF

Experimental Study on the Characteristics of Air Heating Vaporizer at Different Season (계절 변화에 대한 공기 가열식 기화기의 특성에 관한 실험적 연구)

  • Eldwin, D.;Lee, Y.H.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.2
    • /
    • pp.12-19
    • /
    • 2007
  • 현재, 육지에서 필요한 천연 가스 (NG)의 얻기 위한 방법으로 공기 가열식 기화기의 사용이 증가하고 있다. 특히, 파이프라인에 의해 도달될 수 없는 거리가 멀리 떨어진 소외된 지역까지 보낼 수 있기 때문에 소형 위성기지의 역할은 대단히 중요하다고 할 수 있다. 소형 위성기지의 LNG는 인수기지에서 탱크로리를 이용하여 배달되고 그 후에 위성기지에서 기화과정을 통하여 각 수요처로 보내어진다. 공기 가열식 기화기는 LNG 인수기지 외의 소형 위성기지 단위에서 최근 많이 개발되고 사용되고 있는 기화기의 종류 중 하나라고 할 수 있다1). 효율적인 공기 가열식 기화기를 개발하기 위하여, 핀이 없는 경우와 핀이 8개이고 핀의 길이가 55 mm인 공기 가열식 기화기를 사용하여 실험을 진행하였고 그리고 나서 두 가지 유형의 기화기를 비교하였다. 실험조건은 기화기의 길이 변화와 여러 가지 주위 조건(온도, 습도, 풍속)을 변화하였다. 실험에 적용된 주위 온도는 각 계절별 온도와 동일한 온도를 적용하였다. 본 실험에서 나타내고자 한 공기가열식 기화기의 주요 특성은 각 계절별 조건에 따른 입구 측과 출구 측의 온도차를 비교하는 것이다. 액화천연가스(LNG)를 가지고 실험을 하는 것은 위험성이 있어 특성이 비슷하면서 안전한 $LN_2$를 사용하여 실험을 진행하여 핀을 가지는 기화기가 핀이 없는 기화기보다는 좋다는 결과를 확인할 수 있었다.

  • PDF