• Title/Summary/Keyword: '-고'

Search Result 45,380, Processing Time 0.061 seconds

Compressive Strength and Chloride Permeability of High Strength Concrete according to the Variety of Mineral Admixtures (광물질혼화재 종류별 고강도콘크리트의 압축강도 및 촉진 염소이온침투 특성)

  • Moon Han-Young;Kim Byoung-Kwon
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.407-414
    • /
    • 2004
  • The purpose of this study is to evaluate the ability to resist chloride ions penetration of the concrete structure under marine environment in south-east asia especially. In this study, high strength concrete(HSC) with various combination of ordinary portland cement(OPC), blast-furnace slag(SG) and silica fume(SF) are cured 23 and $35^{\circ}C$ considering the site weather, and are cured in water for 3, 7 or 56 days respectively. And to investigate the fundamental properties and the resistance of chloride penetration of various HSC, setting time, slump flow, compressive strength, void and ASTM C 1202 test were conducted. Test results show that the compressive strength of HSC is similar regardless of SG replacement ratio and total charge passed of chloride is the smallest at 40% replacement of SG. The compressive strength of G4FS HSC is, besides, outstandingly high at early age compare with other HSC, but the compressive strength of G4F HSC, which is vary according to curing temperature and condition, most high at the age after 7 days. Total passed charge of HSC get larger in the order G4FS

Sevoflurane Insufflation Sedation for the Dental Treatment of a Patient with Pulmonary Arterial Hypertension : A Case Report (폐동맥 고혈압 환자의 치과치료에서 세보플루란 흡입 진정의 사용 : 증례보고)

  • Chi, Seongin;Kim, Seungoh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.1
    • /
    • pp.75-79
    • /
    • 2015
  • Pulmonary arterial hypertension (PAH) is a common complication of Congenital heart defects (CHD) with left-to-right shunts, and PAH with increased pulmonary vascular resistance (PVR) is associated with considerable morbidity and mortality. General anesthesia (GA) can be life-threatening in patients with PAH, because the positive pressure ventilation during GA increases pulmonary arterial pressure and decreases pulmonary blood flow. This may also lead to hypoxia. Therefore, spontaneous ventilation may be safer than positive pressure ventilation in patients with PAH. A five-year-old male child, weighing 11 kg, with medical history showing a total correction of Tetralogy of Fallot (TOF) in 2009 and ongoing treatment with hypertension (HTN) medicine since 2007, visited the Dankook University Dental Hospital. He had multiple dental caries, and the treatment was completed under sevoflurane insufflation sedation via nasal cannula. The patient remained sedated throughout the operation while maintaining normal vital signs and spontaneous respiration. In conclusion, sevoflurane insufflation sedation may be a safer alternative to GA for the dental treatment of patients with PAH.

Multiple Xanthomatosis in Familiar Hypercholesterolemia Patient - A case report - (가족성 고콜레스테롤혈증 환자에서의 다발성 황색종 - 1례 보고 -)

  • Rhee, Seung-Koo;Lee, Hwa-Sung;Moon, Chan-Woong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2000
  • We experienced the case of familiar hypercholesterolemia with multiple xanthomas which was treated by combined surgical and medical therapy. He was 26-year-old male patient of familiar hypercholesterolemia with multiple xanthomas in 22 sites on whole body, and was treated by 17 surgical excisions of the xanthomas and by medical therapy of the hypercholesterolemia. There was a normal healing process of the surgical wounds. Continual postoperative medical therapy of the hypercholesterolemia was done. There was no recurrence of the symptoms during more than 13 months of follow-up. But the serum level of the cholesterol was not lowered significantly, so we are treating him with drug therapy. Familial hypercholesterolemia is caused by a specific disorder of lipid metabolism, and is characterized by increased LDL cholesterol, tendon xanthomas, coronary disease associated with autosomal dominant transmission. Xanthomas usually appear in the second decade of life with familiar hypercholesterolemia which may have high risk for premature coronary atherosclerosis, which might be prevented with early diagnosis and medical treatment. So, orthopedic surgeons do not only excise the xanthomatosis surgically but also can diagnose the underlying hypercholesterolemia.

  • PDF

Clinical Correlates of Subcortical Hyperintensities on Magnetic Resonance Imaging in Patients with Bipolar Disorder : Preliminary Study (양극성장애 환자의 뇌자기공명영상에서 보이는 피질하 고신호광도의 임상적 상관변수에 관한 예비적 연구)

  • Yoon, Dae Hyun;Kwon, Jun Soo;Han, Moon Hee;Chang, Kee Hyun
    • Korean Journal of Biological Psychiatry
    • /
    • v.4 no.1
    • /
    • pp.60-66
    • /
    • 1997
  • Objective : Accumulating evidence suggests a greater number of subcortical hyperintensities in the brain of patients with bipolar disorder. We studied the Clinical correlates of subcortical hyperintensities on magnetic resonance imaging in patients with Bipolar Disorder : Methods : Magnetic resonance images of the brain were obtained for 32 patients with bipolar disorder. The presence and location of hyperintensities were assessed. We compared clinical variables between patients with subcortical hyperintensities and patients without them. Results : Seven patients(21.8%) had subcortical hyperintensities, but among 8 patients who were 40 years or older, 5 patients(62%) had them. Age and age at onset of patients with subcortical hyperintensities were significantly older than patients without them. Psychotic symptoms were more frequent in patients with hyperintensities. Patients without hyperintensities had more familial loadings. Conclusion : Given the limitations of the study, our results should be seen as preliminary. This study, however, provides preliminary evidence supporting the notion that the onset, clinical feature and course of some bipolar disorders of late onset may be determined by underlying subcortical abnormalities, with such abnormalities being the consequence of factors related to aging or neurodegeneration(such as impaired cerebral circulation) rather than genetic factors which predispose to early-onset bipolar disorders.

  • PDF

Comparing Laboratory Responses of Engineered Emulsified Asphalt and Foamed Asphalt Mixtures for Cold In-place Recycling Pavement (현장 상온 재생 아스팔트 포장을 위한 고점착 유화 아스팔트 혼합물과 폼드 아스팔트 혼합물의 반응특성 비교)

  • Kim, Yong-Joo Thomas;Lee, Ho-Sin David
    • International Journal of Highway Engineering
    • /
    • v.12 no.1
    • /
    • pp.79-86
    • /
    • 2010
  • Cold in-place recycling (CIR) using emulsified asphalt or foamed asphalt has become a more common practice in rehabilitating the existing asphalt pavement due to its cost effectiveness and the conservation of paving materials. As CIR continues to evolve, the engineered emulsified asphalt was developed to improve the field performances such as coating, raveling, retained stability value and curing time. The main objective of this research is to compare the laboratory responses of the engineered emulsified asphalt (CIR-EE) mixtures against the foamed asphalt (CIR-foam) mixtures using the reclaimed asphalt pavement (RAP)materials collected from the CIR project on U.S. 20 Highway in Iowa. Based on the visual observation of laboratory specimens, the engineered emulsified asphalt coated the RAP materials better than the foamed asphalt because the foamed asphalt is to create a mastic mixture structure rather than coating RAP materials. Given the same compaction effort, CIR-EE specimens exhibited lesser density than CIR-foam specimens. Both Marshall stability and indirect tensile strength of CIR-EE specimens were about same as those of CIR-foam specimens. However, Marshall stability and indirect tensile strength of the vacuum-saturated wet specimens of CIR-EE mixtures were higher than those of CIR-foam mixtures. After four hours of curing in the room temperature, the CIR-EE specimens showed less raveling than the CIR-foam specimens. On the basis of test results, it can be concluded that the CIR-EE mixtures is less susceptible to moisture and more raveling resistant than CIR-foam mixtures.

Structural Design Requirements and Safety Evaluation Criteria of the Spent Nuclear Fuel Disposal Canister for Deep Geological Deposition (심지층 고준위폐기물 처분용기에 대한 설계요구조건 및 구조안전성 평가기준)

  • Kwon, Young-Joo;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.229-238
    • /
    • 2007
  • In this paper, structural design requirements and safety evaluation criteria of the spent nuclear fuel disposal canister are studied for deep geological deposition. Since the spent nuclear fuel disposal canister emits high temperature heats and much radiation, its careful treatment is required. For that, a long term(usually 10,000 years) safe repository for the spent nuclear fuel disposal canister should be secured. Usually this repository is expected to locate at a depth of 500m underground. The canister which is designed for the spent nuclear fuel disposal in a deep repository in the crystalline bedrock is a solid structure with cast iron insert, corrosion resistant overpack and lid and bottom, and entails an evenly distributed load of hydrostatic pressure from underground water and high pressure from swelling of bentonite buffer. Hence, the canister must be designed to withstand these high pressure loads. If the canister is not designed for all possible external loads combinations, structural defects such as plastic deformations, cracks, and buckling etc. may occur in the canister during depositing it in the deep repository. Therefore, various structural analyses must be performed to predict these structural problems like plastic deformations, cracks, and buckling. Structural safety evaluation criteria of the canister are studied and defined for the validity of the canister design prior to the structural analysis of the canister. And structural design requirements(variables) which affect the structural safety evaluation criteria should be discussed and defined clearly. Hence this paper presents the structural design requirements(variables) and safety evaluation criteria of the spent nuclear fuel disposal canister.

  • PDF

A Investigation on Inelastic Lateral-Torsional Buckling Strength of I-Beam with Load Height Effects (하중고 효과가 비탄성 I형보의 횡-비틀림 좌굴거동에 미치는 영향 고찰)

  • Park, Yi Seul;Yoo, Sang Ryang;Oh, Jeong Jae;Park, Jong Sup
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.155-155
    • /
    • 2011
  • 일반적으로 I형 보에 횡하중이 작용하는 경우, 횡 변위와 함께 회전을 동반하는 횡-비틀림 좌굴(Lateral-Torsional Buckling)이 발생하게 된다. 이러한 I형 보의 탄성 및 비탄성 횡-비틀림 좌굴에 대한 해석적 이론적 연구는 이미 많은 연구자들에 의해 수행되었다(Timoshenko 등, 1961; Galambos, 1963; Lindner, 1974; Trahair, 1993). I형 보의 비지지 길이 내 하중이 작용할 때 모멘트 구배계수(Cb)는 하중이 부재 단면에 작용하는 위치에 따라 달라지게 되는데 이를 하중고 효과(Load Height Effects)라고 한다. 탄성 영역 내 비지지길이가 존재하는 I형 보의 하중고 효과를 고려한 모멘트 구배계수 제안식은 Nethercot & Rockey(1971)에 의해 연구된 바 있다. 또한 Helwig 등(1997)은 Nethercot & Rockey(1971)의 제안식을 간략화 하여 탄성 영역 내 비지지길이가 존재하는 I형 보의 하중고 효과를 고려한 모멘트 구배계수식을 제안하였다. 그러나 현재까지 진행 된 하중고 효과에 대한 연구는 탄성 영역 내 비지지 길이가 존재하는 I형 보에 대한 제안식이며 현재까지 비탄성 영역 내 비지지 길이를 갖는 I형 보의 하중고 효과에 대한 연구는 진행된 바 없다. 본 연구는 비탄성 영역 내 비지지 길이가 존재하는 I형 보의 하중고 효과를 고려한 비탄성 횡-비틀림 좌굴강도에 대한 연구를 수행하였다. 하중조건으로는 집중하중 과 등분포 하중을 적용시켰으며, 비선형 횡-비틀림 좌굴 해석을 위해 잔류응력 및 초기변형을 고려하였다. Pi와 Trahair(1995)이 고려한 단순직선분포를 잔류응력으로 가정하였으며, 국내 I형강 표준 치수 허용치(현대제철, 2006)에 근거하여 부재 길이의 0.1%를 초기 최대 횡 변위로 적용하여 초기제작오차로 고려하였다. 유한요소해석결과를 바탕으로 Nethercot & Rockey(1971)와 Helwig 등(1997)의 연구내용을 바탕으로 범용구조해석 프로그램(ABAQUS, 2007)을 이용하여 비탄성 영역 내 존재하는 I형보의 횡-비틀림 좌굴강도를 산정하였다. 유한요소해석결과를 바탕으로 Nethercot & Rockey(1971)및 Helwig 등(1997)의 모멘트구배계수 제안식과 비교 분석 하였고 회기분석프로그램 MINITAB(2006)을 이용하여 비탄성 영역 내 비지지길이가 존재하는 I형보의 하중고 효과를 고려한 모멘트구배계수식을 개발 제안하였다. 본 연구에서 개발된 제안식은 경제적이고 합리적인 휨부재 강도평가에 적극 활용될 수 있으며, 비탄성 영역내 I형보의 횡-비틀림 좌굴강도 및 휨강도 연구에 널리 활용될 것이다.

  • PDF

Development of the auto leveling mechanism for side-by-side refrigerator doors (양문형 냉장고 도어의 자동 단차 맞춤 메커니즘 개발)

  • Weng, Lei;Yun, Jae-Deuk;Jung, Yoong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3165-3174
    • /
    • 2012
  • Recently the increasingly common large refrigerator is the side by side(SBS) refrigerator whose freezing chamber and refrigerating chamber are set side by side. But one of the biggest dissatisfaction of customers about SBS refrigerator is that the two doors don't meet the same height when they are closed. It is called door height difference(DHD). The main cause of DHD is the unevenness of floor on which a refrigerator is placed or the cabinet deformation caused by long time use. When the DHD is confirmed, the customer or maintenance personnel use wrench to adjust the support screw to make the refrigerator to reach the horizontal position. But for big refrigerator, it is not only difficult for women and old people who don't have enough force to adjust it, but also inappropriate to require customers to do this job. In order to resolve this problem, this research proposes a new mechanism which can detect the DHD and adjust two doors to the same height automatically. The adjustment would be completed during opening and closing the doors, avoid needing hard operation with wrench by hand.

The Fluidity of High Flowing Concrete According to the Component Ratio of Superplasticizer (고성능감수제 구성비율에 따른 고유동콘크리트의 유동특성)

  • Kim Moo-Han;Kim Yong-Ro;Kim Jae-Hwan;Ho Jang-Jong;Lee Tae-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.147-154
    • /
    • 2004
  • It is the aim of this study to propose the fundamental data for the establishment of the application and qualify standard of the mixed type superplasticizer after investigating and comparing the fluidity of high flowing concrete according to the component ratio of superplasticizer such as naphthalene sulfonated and melamine sulfonated. The results of this study were shown as the followings; 1) The fluidity and adsorption ratio of cement-paste were improved according to the increasing of naphthalene sulfonated component ratio, and apparent viscosity of cement-paste was improved according to the Increasing of melamine sulfonated component ratio. 2) In case of using the granulated blast-furnace slag, the fluidity of cement-paste was considerably good and the adsorption ratio was decreased and in case of using fly-ash, the apparent viscosity and adsorption ratio of cement-paste were improved. 3) The dispersive capacity performance of concrete can be improved by means of the increasing of naphthalene sulfonated component ratio. Also the viscosity and early strength can be improved by means of the increasing of melamine sulfonated component ratio.

Mix Design of High Performance Concrete Using Maximum Density Theory (최대 밀도 이론을 이용한 고성능콘크리트의 배합 설계)

  • Lee, Seung-Han;Jung, Yong-Wook
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.377-383
    • /
    • 2007
  • In recent years the field application of high performance concrete has been increased to improve the quality and reliability of concrete structures. The mix design of the high performance concrete includes the 2 set-off mixture theory of mortar and coarse aggregate and that of paste and aggregate. The 2 set-off mixture theory of mortar and coarse aggregate has a problem of having to determine its value through repeated experiments in applying the rheological characteristics of mortar. The 2 set-off mixture theory of paste and aggregate has never been applied to high performance concrete since it doesn't take into account the relationship between optimum fine aggregate ratio and unit volume of powder nor does it consider the critical aggregate volume ratio. As the mixture theory of these high performance concretes, unlike that of general concrete, focuses on flowability and charge-ability, it does not consider intensity features in mix design also, the unit quantity of the materials used is determined by trial and error method in the same way as general concrete. This study is designed to reduce the frequency of trial and error by accurately calculating the optimum fine aggregate ratio, which makes it possible to minimize the aperture of aggregate in use by introducing the maximum density theory to the mix design of high performance concrete. Also, it is intended to propose a simple and reasonable mix design for high performance concrete meeting the requirements for both intensity and flowability. The mix design proposed in this study may reduce trial and error and conveniently produce high performance concrete which has self-chargeability by using more than the minimum unit volume of powder and optimum fine aggregate with minimum porosity.