• Title/Summary/Keyword: $m_v$ method

Search Result 2,701, Processing Time 0.033 seconds

Determination of carvedilol in human plasma by high-performance liquid chromatography

  • Lee, Jung-Ae;Lee, Ye-Rie;Kim, Ho-Hyun;Lee, Hee-Joo;Lee, Kyung-Ryul
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.220.1-220.1
    • /
    • 2003
  • A sensitive and selective liquid chromatographic method for the determination of carvedilol in human plasma was developed and validated. Analytes were separated on a XTerra C18 column with acetonitrile-methanol-30 mM KH$_2$PO$_4$ (pH 2.5) (20 : 20 : 60, v/v/v), as mobile phase. One mL plasma were pipetted into glass tubes and spiked with 0.05 mL of internal standard solution. After adding 7 mL of diethyl ether, the plasma sample was then shacked for 15 min. A centrifuged upper layer was back-extracted with 150 uL of 0.05 M sulfuric acid. (omitted)

  • PDF

Effects of Noradrenaline on the Membrane Potential of Prostatic Neuroendocrine Cells of Rat

  • Kim, Jun-Hee;Shin, Sun-Young;Uhm, Dae-Yong;Kim, Sung-Joon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.1
    • /
    • pp.47-52
    • /
    • 2003
  • The prostate gland contains numerous neuroendocrine cells that are believed to influence the function of the prostate gland. Our recent study demonstrated the expression of both ${\alpha}1$- and ${\alpha}2$-ARs, signaling the release of stored $Ca^{2+}$ and the inhibition of N-type $Ca^{2+}$ channels, respectively, in rat prostate neuroendocrine cells (RPNECs). In this study, the effects of NA on the resting membrane potential (RMP) of RPNECs were investigated using a whole-cell patch clamp method. Fresh RPNECs were dissociated from the ventral lobe of rat prostate and identified from its characteristic shape; round or oval shape with dark cytoplasm. Under zero-current clamp conditions with KCl pipette solution, the resting membrane potential (RMP) of RPNECs was between -35 mV and -85 mV. In those RPNECs with relatively hyperpolarized RMP (<-60 mV), the application of noradrenaline (NA, $1{\mu}M$) depolarized the membrane to around -40 mV. In contrast, the RPNECs with relatively depolarized RMP (>-45 mV) showed a transient hyperpolarization and subsequent fluctuation at around -40 mV on application of NA. Under voltage clamp conditions (holding voltage, -40 mV) with CsCl pipette solution, NA evoked a slight inward current (<-20 pA). NA induced a sharp increase of cytosolic $Ca^{2+}$ concentration ($[Ca^{2+}]_c$), measured by the fura-2 fluorescence, and the voltage clamp study showed the presence of charybdotoxin-sensitive $Ca^{2+}$-activated $K^+$ currents. In summary, adrenergic stimulation induced either depolarization or hyperpolarization of RPNECs, depending on the initial level of RMP. The inward current evoked by NA and the $Ca^{2+}$-activated $K^+$ current might partly explain the depolarization and hyperpolarization, respectively.

Method development and validation of spectrophotometric and RP-HPLC methods for simultaneous estimation of spironolactone and furosemide in bulk and combined tablet dosage forms

  • Chavan, Rohankumar R.;Bhinge, Somnath D.;Bhutkar, Mangesh A.;Randive, Dheeraj S.;Salunkhe, Vijay R.
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.212-224
    • /
    • 2021
  • The intent of the present work was to develop a simple, sensitive, accurate, precise, rapid and economical UV- spectrophotometric and reverse phase high pressure liquid chromatographic method for the simultaneous estimation of Spironolactone and Furosemide in bulk and combined tablet dosage forms. UV-Spectrophotometry was carried out by simultaneous equation method using 0.02 M potassium dihydrogen phosphate buffer pH 3.5: Acetonitrile (50:50) v/v as a solvent. The linearity range was 2-14 ㎍ mL-1 for Spironolactone and Furosemide with a correlation coefficient > 0.99. The chromatographic separation was achieved on 250 mm × 4.6 mm, hypersil BDS C18 column with particle size 5 ㎛, by using an isocratic mixture of 0.02 M potassium dihydrogen phosphate buffer pH 3.5: Acetonitrile: tert butyl methyl ether (49:50:1) v/v/v as a solvent at a flow rate of 1 mL min-1 and UV detection was carried out at 254 nm. The retention time were observed to be 3.666 and 6.661 minutes for Furosemide and Spironolactone respectively. The two developed methods were validated according to the ICH guidelines for accuracy, precision, linearity, LOD, LOQ and were found to be within the limits. It can be concluded that these two methods could be successfully used for the simultaneous estimation of Spironolactone and Furosemide in bulk and combined tablet dosage forms.

Synthesis of a New α-Dioxime Derivative and Its Application for Selective Homogeneous Liquid-Liquid Extraction of Cu(II) into a Microdroplet Followed by Direct GFAAS Determination

  • Ghiasvand, A. R.;Shadabi, S.;Kakanejadifard, A.;Khajehkoolaki, A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.5
    • /
    • pp.781-785
    • /
    • 2005
  • A fast and reliable method for the selective separation and preconcentration of $Cu^{2+}$ ions using homogeneous liquid-liquid extraction was developed. A new $\alpha$-dioxime derivative (2H-1,4-benzothioazine-2,3(4H)dionedioxime, Dioxime I) was synthesized and investigated as a suitable selective complexing ligand for $Cu^{2+}$ ions. Zonyl FSA (FSA) was applied as a phase-separator agent under the slightly acidic pH conditions. Under the optimal experimental conditions ([FSA] = 3.2% w/v, [THF] = 19.5% v/v, [Dioxime I] = 1.9 ${\times}\;10^{-3}$ M, and pH = 4.7), 10 ${\mu}g\;of\;Cu^{2+}$ in 5.2 mL aqueous phase could be extracted quantitatively into 80 $\mu$L of the sedimented phase. The maximum concentration factor was 65-fold. The limit of detection of the proposed method was 0.005 ng $mL^{-1}$. The reproducibility of the proposed method, on the 10 replicate measurements, was 1.3%. The influence of the pH, type and volume of the water-miscible organic solvent, concentration of FSA, concentration of the complexing ligand and the effect of different diverse ions on the extraction and determination of $Cu^{2+}$ ions were investigated. The proposed method was applied to the extraction and determination of $Cu^{2+}$ ion in different synthetic and natural water samples.

Study on Sensory Papillae of Metagonimus yokogawai Cercaria (Metagonimus yokogawai 세르카리아의 감각유두에 관한 연구)

  • 김재진;민득영소진탁
    • Parasites, Hosts and Diseases
    • /
    • v.22 no.1
    • /
    • pp.11-20
    • /
    • 1984
  • A number of studies on the papillae of cercariae of trematodes reported that the papillar patterns (or chaetotaxy) of cercariae might be an excellent method to attain better understanding of the digenetic trematodes (Richard, 1971 ; Short and Cartrett, 1973; Bayssade-Dufour, 1979) . The present study was aimed to determine the number, distribution pattern and structure of the sensory papillae of Metagonimus yokogawai cercariae, and to elucidate the chaetotaxy of this digenetic trematode. M. yokogawai cercariae were pipetted from a vial in which infected snails (Semisulcospira libertina) had been kept for 3 hours. The snails were collected from an endemic area of M. yokogawai, Boseong river in west-southern part of Korea. Observations of papillae were based on light microscopy of those stained with silver nitrate, and on scanning electron microscopy The results are summarized as follows: 1, All papillae observed were uniciliated. 2. Cilia in anterior tip were shorter than the others in other portions. 3. The body papillae were arranged in essentially symmetrical patterns, Total number of the papillae was 126(63 pairs) in average; anterior tip 40(20 pairs), ventral 20(10 pairs), lateral 42(21 pairs), and caudal 8(4 pairs). 4. The chaetotany of M. yokogawai cercaria was: Ci cycle ($3+3C_{I}V,{\;}2+2C_{I}L,{\;}2+3C_{I}D),{\;}C_{II}{\;}cycle(2C_{II}V,{\;}1C_{II}L,{\;}2C_{II}D),{\;}C_{lll}{\;}cycle{\;}(1+lC_{III}V,{\;}1C_{IlI}L),{\;}C_{IV}{\;}cycle{\;}(1C_{IV}V,{\;}IC_{lV}L){\;}in{\;}cephalic{\;}region:{\;}A_I(1A_{IV}V,{\;}1+2A_{I}L,{\;}1A_{I}D),{\;}A_{II}(1A_{II}V,{\;}1+3A_{II}L,{\;}1A_{II}D),{\;}A_{III}(1A_{III}V,{\;}1+1A_{III}L,{\;}1A_{III}D){\;}and{\;}A_{IV}(1A_{IV}V,{\;}2A_{IV}L)$ in antacetabular region: $1M_{I}V{\;}and{\;}2M_{I}L$ in median: $1+1P_{I}L,{\;}1P_{II}L,{\;}1P_{II}D,{\;}1P_{III}L,{\;}1P_{IV}L{\;}and{\;}1P_{IV}D$ in postacetabular region: 2-2-2-2 in caudal region.

  • PDF

On-state resistance secreasing effect of mim antifuse by re-programming method (재 프로그래밍 방법에 의한 MIM ANTIFUSE의 온저항 감소 효과)

  • 임원택;이상기;김용주;이창효;권오경
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.3
    • /
    • pp.194-199
    • /
    • 1997
  • We fabricated MIM (Metal-Insulator-Metal) antifuses with Al/a-Si/Mo structure and then examined the I-V characteristics and on-state resistance distribution of antifuses. The leakage current of antifuses is below $1Pa/{\mu}m^2$, and programming voltage lies within 10 to 11 V. After programming, on-resistance of antifuses is mostly 10-20$\Omega$ and 20% of these have above 100$\Omega$. In order to reduce on-resistance and the deviation of this distribution, we tried to inject current again into already programed antifuses (we call this re-programming method). From this method, the resistance of antifuses with above 100Ω can be reduced to below 50$\Omega$. When antifuses are programmed by re-programming method, these antifuses have more uniform and lower on-resistance than programmed with one-pulse.

  • PDF

Growth of HgCdTe thin film by the hot-wall epitaxy method (Hot-wall epitaxy 방법에 의한 HgCdTe 박막 성장)

  • 최규상;정태수
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.4
    • /
    • pp.406-410
    • /
    • 2000
  • Using the hot-wall epitaxy method, we grew a $Hg_{1-x}Cd_xTe$ (MCT) thin film in-situ after growing (111) CdTe of 9 $mu \textrm{m}$ as a buffer layer. The value of FWHM of double crystal x-ray diffraction rocking curve was 125 arcsec and the surface morphology was clean with a small roughness of 10 nm. From measuring the photocurrent of the grown MCT thin film, the maximum peak wavelength and the cut-off wavelength were 1.1050 $\mu\textrm{m}$ (1.1220 eV) and 1.2632 $\mu\textrm{m}$ (0.9815 eV), respectively. This peak wavelength corresponds to the peak of the band gap due to the intrinsic transition of the photoconductor. Therefore, the MCT thin film could be used as the photoconducting detector sensing a near-IR wavelength band from 1.0 to 1.6 $\mu\textrm{m}$.

  • PDF

Study on electrical properties of photoconductors for radiation detector application based on liquid crystal (액정 기반 방사선 검출기 적용을 위한 광도전체의 전기적 특성 연구)

  • Kang, Sang-Sik;Choi, Young-Zoon;Lee, Mi-Hyun;Kim, Hyun-Hee;No, Si-Chul;Cho, Kyu-Suck;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.27-30
    • /
    • 2010
  • A X-ray optical modulator measures x-ray dose using optical transmissivity ratio change of the liquid crystal cell. To apply in this optical modulator, we made photoconductor films and compared electrical properties of this films in this study. Photoconductors are deposited on ITO glass with $200{\mu}m$ using the percipitation method and print method. I-V test was conducted to alalyze electrical properties of this films and measured darkcurrent and SNR was acquired using the measured dark current and sensitivity. As a result of this measurements, $HgI_2$ film made by precipitation method is lower(about 40%) darkcurrent than $HgI_2$ films made by precipitation method and sensitivity is two times greater than print method. And we knew that $HgI_2$ films were also 10~25 times greater SNR at $1v/{\mu}m$ than $PbI_2$, PbO, CdTe film made by precipitation method. This results suggest that $HgI_2$ films made by precipitation method has improved characteristics of x-ray dose meter by applying in x-ray optical modulator.

Characteristics of a Planar Multijunction Thermal Converter (평면형 다중접합 열전변환기의 특성)

  • Jo, Hyeon-Deok;Kim, Jin-Seop;Lee, Jong-Hyeon;Lee, Jeong-Hui;Park, Se-Il;Gwon, Seong-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.10
    • /
    • pp.699-705
    • /
    • 2001
  • Six types of planar thermal converters from TC 1 to TC 6 were designed and fabricated for the purpose of being used as practical standards to alternating current. The respective voltage responses in air and in a vacuum of TC 6, which has the smallest thermal loss, were about 4.03mV/mW and about 6.38 mV/mW. Thermal time constant of TC 6, which has also the smallest heater thermal inertia, was about 8 ms. The respective variations of AC-DC voltage and current transfer errors from sample to sample, which were measured by FRDC(fast reversed DC) method, were about $\pm$0.41 ~$\pm$0.85 ppm and about $\pm$0.15~$\pm$1.16 ppm in the frequent range of 40 Hz~10 KHz with appling 1 V and 5 mA rms sine waves to the converters. All converters investigated exhibited sufficiently low AC-DC transfer errors to be used as practical standards.

  • PDF

The comparisons of three scatter correction methods using Monte Carlo simulation (몬테카를로 시뮬레이션을 이용한 산란보정 방법들에 대한 비교)

  • 봉정균;김희중;이종두;권수일
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.73-81
    • /
    • 1999
  • Scatter correction for single photon emission computed tomography (SPECT) plays an important role to improve image quality and quantitation. The purpose of this study was to investigate three scatter correction methods using Monte Carlo simulation. Point source and Jaszack phantom filled with Tc-99m were simulated by Monte Carlo code, SIMIND. For scatter correction, we applied three methods, Compton window (CW) method, triple window (TW) method, and dual photopeak window (DPW) method. Point sources located at various depths along the center line within a 20-cm phantom were simulated to calculate the window ratios and corresponding scatter fractions by evaluating the polynomial coefficients for DPW method. Energy windows were located in W$_1$=92-125 keV, W$_2$=124-126 keV, W$_3$=136-140 keV, W$_4$=140-141 keV, and W$_{5}$=154-156 keV. The results showed that in Jaszack phantom with cold sphere and hot sphere, the TW gave the closest contrast and percentage recovery to the ideal image, respectively, while CW overestimated and DPW underestimated the contrast of ideal one. All three scatter correction methods showed an improved image contrast. In conclusion, scatter correction is essential for improving image contrast and accurate quantification. The choice of scatter correction method should be made on the basis of accuracies and ease of implementation.

  • PDF