• Title/Summary/Keyword: $k_0$ factor

Search Result 12,167, Processing Time 0.044 seconds

Estimation of Load Characteristic Factor Considering The Load Pattern and Seasonal Characteristic for Consumer (수용가의 형태와 계절별 특성을 고려한 부하특성계수 재 산정)

  • Hwang, H.M.;Jang, S.I.;Kim, K.H.;Kim, J.E.;Rho, D.S.;Jeong, I.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.450-453
    • /
    • 2003
  • This paper presents the estimation on Load Characteristic Factor(k) which is considered to load pattern and seasonal characteristic of consumer. We can calculate the loss of distribution networks through the equation composing of Load Factor(LF), Loss Load Factor(LLF) and load characteristic factor(k). This equation is similar to the method of Regulator-General Victoria, Australia. Generally, the conventional method for calculating the distribution losses uses k with a constant value from 0.1 to 0.3. However, the k which is a relationship between LF and LLF can be varied by load pattern and seasonal characteristics. It is necessary to estimate the k according to load characteristics. This paper shows the result for recalculating k using the KEPCO's SOMAS data measured in distribution networks.

  • PDF

Association of quality of dental care service on the level of patient satisfaction (치과의료서비스의 질과 환자만족도와의 연관성)

  • Lee, Hyang-Nim;Shim, Hyung-Sun;Kim, Ga-Young
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.383-393
    • /
    • 2011
  • Objectives : This study has been undertaken for the purpose of finding out what influence is made by the dental care service provided to patients by the dental clinics to the level of patient satisfaction to provide the base data for developing and improving the dental care service of dental hygienist. Methods : The survey was undertaken for 500 patients visiting 18 dental clinics in City G and the questionnaire was undertaken for two weeks in May 2010, and 473 copies were analyzed with the exception of the questionnaires with many omissions in the response. Results : 1. Distribution of the level of satisfaction for patient had the dentist factor which was highest in the dentist factor for 4.43 at the age of 60s (p<0.05). and in sole proprietorship for 4.49 (p<0.01). treatment procedure factor which was highest in sole proprietorship for 4.16 (p<0.001). environment of dental clinic factor which was highest at the age of 60 years or older for 4.36 (p<0.05) and in sole proprietorship for 4.14 (p<0.01). 2. Evaluation on the quality of the dental care service of dental hygienist had the kindness of dental hygienists which was highest at the age of 60 years or older for 4.40(p<0.001), knowledge factor of dental hygienist which was highest for 4.34 at the age of 60 years or older (p<0.05) and highest 4.27 for visit dentists(p<0.001) and the patient management and other factor was highest at the age of 60s for 4.47 (p<0.05), and in sole proprietorship for 4.28 (p<0.05). 3. Factors influencing on the level of satisfaction for patient. The level of satisfaction for patient was higher for higher evaluation of the dentist quality (p<0.001), for feeling convenient in treatment procedure and use (p<0.01), for feeling kindness of the dental hygienist (p<0.01), and for higher evaluation in patient management and other management activities of the dental hygienist (p<0.001). Conclusions : In order to heighten the level of satisfaction for patient, it would be necessary to strengthen the kindness and patient management aspect on the patients of the dental hygienist, and it would require to heighten the quality of dentist as patients recognize and heighten the treatment procedure and service convenience of dental clinics.

Comparative Analysis of KoMCI 2004 and KCI 2004 Impact Factors (KoMCI(Korean Medical Citation Index)와 KCI(Korea Citation Index)의 2004년도 영향력지표값 비교분석)

  • Sun, Huh;Lee, Choon-Shil
    • Journal of Information Management
    • /
    • v.36 no.3
    • /
    • pp.183-193
    • /
    • 2005
  • Korean Academy of Medical Sciences began developing Korean Medical Citaton Index(KoMCI) database in 2002, and has announced the impact factors of Korean medical journals published since 2000. In July 2005, Korea Research Foundation also announced the KCI impact factor of journals covering all subject areas for the 2003 and 2004. We compared the impact factor(IF), impact factor excluding self-citation(ZIF), and self-citation impact factor(SIF) of KoMCI 2004 and KCI 2004 in order to disclose why there is such a great difference in the values of impact factors between two databases. Out of 72 medical journals in both database, 59 journals were compared after excluding the missing data in KCI. Mean IF of KoMCI 2004 was 0.2 and that of KCI 2004 was 0.03(p=0.0000). Mean ZIF of KoMCI was 0.06 and that of KCI was 0.01(p=0.000). Mean SIF of KoMCI was 0.139 and that of KCI was 0.02(p=0.0000). We presumed that the major difference in the impact factor values was originated from the fact that KCI does not control the authority of journal names cited in the references. We strongly recommend that it is necessary to control the authority especially if Korea Research Foundation wants to ensure the validity and reliability of KCI data in the evaluation of korean journals.

T helper cell subsets and related cytokines in infertile women undergoing in vitro fertilization before and after seminal plasma exposure

  • Azad, Marziyeh;Keshtgar, Sara;Jahromi, Bahia Namavar;Kanannejad, Zahra;Gharesi-Fard, Behrouz
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.44 no.4
    • /
    • pp.214-223
    • /
    • 2017
  • Objective: In vitro fertilization (IVF) is a well-known method for the treatment of infertility. The present study aimed to compare the differences between infertile women with successful and unsuccessful IVF outcomes regarding the expression of T helper (Th) cell transcription factors and a group of related cytokines before and after exposure to their husbands' seminal plasma. Methods: This study was performed on 19 couples with unexplained infertility undergoing IVF treatment. Among the studied group, nine and 10 couples had successful and unsuccessful IVF outcomes, respectively. This study was carried out using real-time polymerase chain reaction. Results: Before seminal plasma exposure, the expression levels of T-bet (p< 0.007), $interferon-{\gamma}$ (p= 0.013), and tumor necrosis factor $(TNF)-{\alpha}$ (p= 0.017) were higher in the infertile women with IVF failure than in those with successful IVF outcomes, while those of GATA3 (p< 0.001), Foxp3 (p= 0.001), and interleukin (IL)-35 (p< 0.003) were lower. After seminal exposure, the expression of T-bet (p= 0.02), Rorc (p< 0.001), $TNF-{\alpha}$ (p= 0.001), Foxp3 (p= 0.02), and $interferon-{\gamma}$ (p= 0.001) increased in the unsuccessful IVF group, while the expression of Foxp3 (p= 0.02), Rorc (p< 0.001), IL-23 (p= 0.04), IL-17 (p= 0.02), IL-6 (p< 0.001), transforming growth $factor-{\beta}$ (p= 0.01), and IL-35 (p< 0.001) increased in the successful IVF group. Conclusion: In summary, IVF failure was associated with imbalanced Th1/Th2/Th17/Treg responses. Moreover, our results show that seminal plasma might have a positive effect on IVF outcomes via changes in peripheral blood T cell subsets.

An Analytical Study on the Slope Safety Factor Considering Various Conditions (다양한 조건을 고려한 사면안전율에 관한 해석적 연구)

  • Park, Choon-Sik;Ahn, Sang-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.5
    • /
    • pp.31-41
    • /
    • 2019
  • This paper demonstrates safety factor for effective planning at initial stage by utilizing results on changes of safety factor according to various conditions of slop and examines impacts of factors that affect slope safety factors as well. Firstly, it describes shear strength which satisfies minimum allowable safety factor: 1.20 depending on height and slope. As the height increases by 5.0 m, the safety factors decrease by 0.04 while it tends to consistently reduce by approximately 20%, 30% and 40% after height goes to 10.0 m. As slope reduces by about 0.3, the safety factors increases by 0.4, which shows the rate of safety factors on slope grows by about 10%, 20% and 30% on lowering slope. When cohesion goes up by 10.0 kPa the safety factors increases by around 40% respectably while the angle of internal friction grows by $5^{\circ}$, it increases by about 8%. The rate of safety factors is identified as $Fs=3.86H^{-0.59}$, Fs = 0.43 s, Fs = 0.04 c, $Fs=0.02{\phi}$ depending on height, slope and shear strength. The safety factor with rainfall infiltration tends to increase by 18% compared to the condition of saturated surface on earth.

Piezoelectric and Dielectric Characteristics of $NaKNbO_3$ ceramics according to the poling condition (분극조건에 따른 무연 $NaKNbO_3$ 세라믹스의 압전 및 유전 특성)

  • Lee, Sang-Ho;Yoo, Ju-Hyun;Lee, Kab-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.157-159
    • /
    • 2005
  • In this study, in order to develop Pb-free piezoelectric ceramics, $[Li_{0.04}(Na_{0.44}K_{0.52)-(Nb_{0.86}Ta_{0.10}Sb_{0.04})]O_3$ ceramics were fabricated by conventional mixed oxide method and their piezoelectric characteristics were investigated according to the poling condition. The transition temperature from orthorhombic phase to tetragonal phase observed at $93[^{\circ}C]$ and Curie temperature was $346[^{\circ}C]$. At $50[^{\circ}C]$ poling temperature, dielectric constant, electromecha nical coupling factor kp, piezoelectric $d_{33}$ const ant, coercive field Ec, remanant polarization Pr and mechanical quality factor Qm showed the optimum value of 737, 0.45, 209[pC/N], 1l.34[kV/cm], $7.14[{\mu}C/cm^2]$ and 205, respectively.

  • PDF

High-Temperature Electrical Transport and Thermoelectric Properties of La0.75Ba0.25MnO3 Ceramics (고온에서의 La0.75Ba0.25MnO3 세라믹스의 전기전도 및 열전특성)

  • Jung, Woo-Hwan
    • Korean Journal of Materials Research
    • /
    • v.18 no.4
    • /
    • pp.175-180
    • /
    • 2008
  • In this study, the thermoelectric power and resistivity of the perovskite manganite $La_{0.75}Ba_{0.25}MnO_3$ were investigated in the temperature range 300K-1200K. The electrical resistivity and thermoelectric power indicate a transport mechanism dominated by adiabatic small-polaron hopping. The power factor increases from $2{\times}10^{-6}W/mK^2$ to $1{\times}10^{-5}W/mK^2$ as to the temperature increases from 400K to 1200K, which indicates that the compound is highly feasible as a thermoelectric material at high temperatures.

A Study on Advertising Expressive Factors of Fashion Products on Brand Equity -Focused on Mediate Role of Brand Personality- (패션제품 광고표현요소와 브랜드 자산에 관한 연구 -브랜드 개성의 매개효과를 중심으로-)

  • Lee, Seung-Hee;Chang, Yoon-Kyung;Park, Soo-Kyeong
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.11
    • /
    • pp.1659-1668
    • /
    • 2008
  • The purpose of this study was to examine the impact of advertising expressive factors on brand equity and to investigate the role of brand personality as a factor mediate variable. The subject used for this study were 352 female university students. The data was analyzed by descriptive analysis, correlation analysis and confirmatory factor analysis using SPSS program and Amos program. As the result, model fit index showed $X^2$=57.824, df=19, GFI=0.969, CFI=0.959, NFI=0.942, and RMSEA=0.076, providing good model fit. Out of the advertising expressive factors, sophistication and model preference factors gave impact on brand personality. Also, among advertising expressive factors, novelty, sophistication, model preference, information factors affected brand equity. Finally, brand personality influenced on brand equity. Brand equity was affected directly by advertising expressive factors. It was also affected by brand personality which is a mediate factor between advertising expressive factors and brand equity. The results of this study would provide advertising strategy for fashion brand.

Importance of convection during physical vapor transport of Hg2Cl2 in the presence of Kr under environments of high gravitational accelerations

  • Kim, Geug-Tae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Special attention in the role of convection in vapor crystal growth has been paid since some single crystals under high gravity acceleration of $10g_0$ appear considerably larger than those under normal gravity acceleration ($1g_0$). With increasing the gravity acceleration from $1g_0$ up to $10g_0$, the total molar flux for ${\Delta}T$ = 30 K increases by a factor of 4, while for ${\Delta}T$ = 90, by a factor of 3. The maximum molar fluxes for three different gravity levels of $1g_0$, $4g_0$ and $10g_0$, appear approximately in the neighborhood of y = 0.5 cm, and the molar fluxes show asymmetrical patterns, which indicate the occurrence of either one single or more than one convective cell. As the gravitational level is enhanced form $1g_0$ up to $10g_0$, the intensity of convection is increased significantly through the maximum molar fluxes for ${\Delta}T$ = 30 K and 90 K. At $10g_0$, the maximum total molar flux is nearly invariant for for ${\Delta}T$ = 30 K and 90 K. The total molar flux increases with increasing the gravity acceleration, for $1g_0{\leq}g_y{\leq}10g_0$, and decreases with increasing the partial pressure of component B, a noble gas called as Kr (Krypton), $P_B$. The ${{\mid}U{\mid}}_{max}$ is directly proportional to the gravity acceleration for 20 Torr $P_B{\leq}300$ Torr. As the partial pressure of $P_B$ (Torr) decreases from 300 Torr to 20 Torr, the slopes of the ${{\mid}U{\mid}}_{max}s$ versus the gravity accelerations increase from 0.29 sec to 0.54 sec, i.e. by a factor of 2. The total molar flux of $Hg_2Cl_2$ is first order exponentially decayed with increasing the partial pressure of component B, $P_B$ (Torr) from 20 Torr up to 300 Torr.

Characteristics of PAN-PZI Ceramics with $BaCO_3$Addition ($BaCO_3$ 첨가량에 따른 PAN-PZT계 세라믹스의 특성)

  • 박타리;이동균;최지원;김현재;윤석진;조봉희;고태국
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.981-984
    • /
    • 2001
  • The piezoelectric properties of 0.05pb(A $l_{0.5}$N $b_{0.5}$) $O_3$-0.95Pb(Z $r_{0.52}$ $Ti_{0.48}$) $O_3$+0.7wt%N $b_2$ $O_{5}$ +0.5wt%Mn $O_2$ceramics with the additives of BaC $O_3$were investigated. For the additions of BaC $O_3$, the dielectric constant ($\varepsilon$$^{T}$ $_{33}$ ), the piezoelectric constant ( $d_{33}$ ), the electromechanical coupling factor ( $k_{p}$ ), and . the mechanical quality factor ( $Q_{m}$ ) were increased, but dielectric loss (tan$\delta$) was decreased. The highest piezoelectric properties and dielectric properties were observed at the sintered temperature of 120$0^{\circ}C$ and 0.4 wt% of BaC $O_3$, and the properties of $d_{33}$ , $k_{p}$ , and $Q_{m}$ were 339(x10$^{-12}$ C/N), 59% and 1754, respectively.vely.y.y.

  • PDF