• Title/Summary/Keyword: $Z_2$

Search Result 7,101, Processing Time 0.036 seconds

Phospholipids from Bombycis corpus and Their Neurotrophic Effects

  • Kwon, Hak-Cheol;Jung, I-Yeon;Cho, Se-Yeon;Cho, Ock-Ryun;Yang, Min-Cheol;Lee, Sung-Ok;Hur, Jin-Young;Kim, Sun-Yeou;Yang, Jong-Beom;Lee, Kang-Ro
    • Archives of Pharmacal Research
    • /
    • v.26 no.6
    • /
    • pp.471-477
    • /
    • 2003
  • Three phospholipids (4-6) and three aromatic amines (1-3) were obtained from the methanol extract of Bombycis corpus. Based on spectral data, their structures have been elucidated as nicotiamide (1), cytidine (2), adenine (3), 1-Ο-(9Z-octadecenoyl)-2-Ο-(8Z,11Z-octadecadienoyl)-sn-glycero-3-phosphorylcholine (4), 1,2-di-Ο-hexadecanoyl-sn-glycero-3-phosphorylcholine (5) and 1,2-di-Ο-9Z-octadecenoyl-sn-glycero-3-phosphorylcholine (6). We examined the effects of compounds on synthesis of NGF in cultured astrocytes. By RT-PCR analysis, expresison of NGF mRNA in astrocytes cultured in serum-starvation increased after the addition of phospholipid (10 $\mu$M). The NGF content in the culture medium was significantly increased by compound 5, compared with the control value. These results suggest that three phospholipid compounds isolated from the methanol extract of Bombycis corpus may exert neurotrophic effects by stimulation of NGF synthesis in astrocytes.

A Study on the Output Voltage and Efficiency of the Single-Phase Z-Source Inverters According to Duty Ratio (듀티 비에 따른 단상 Z-소스 인버터의 효율과 출력 전압에 관한 연구)

  • Hong, Seung-Pyo;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.8-19
    • /
    • 2011
  • This paper was compared for the output voltage and efficiency of the single-phase Z-source inverter(ZSI) according to shoot through duty ratio D. The eight single-phase ZSI in this study are typical ZSI, Embedded ZSI(EZSI), Improved ZSI(IZSI), Quasi ZSI(QZSI), Series ZSI, Trans ZSI(TSI), Switched inductor ZSI(SL-ZSI) and Extended boost ZSI (exZSI). The eight ZSI are divided into two Groups. ; Group-1 which is ZSI with the ordinary voltage boost factor B, and Group-2 which is ZSI with the maximum voltage boost factor B. For the execution of the proposed study, the PSIM simulation was achieved under the condition of input DC voltage=150[V] of ZSI, load =30[${\Omega}$] and 60[Hz] output filter. The output voltage and efficiency of each ZSI were calculated within the limits of D=0.1~0.4. As a result, the output peak voltage of Group-2 was suddenly increased in a specified duty ratio D, and its efficiency was rapidly decreased. On the contrary, Group-1 shown the output and efficiency characteristics without sudden change compared to Group-2 despite the duty ratio increase. The efficiency of the Group-2 was sharply declined at duty ratio D of the most output voltage, but, in case of Group-1, the efficiency was slightly declined. Finally, the input DC current of ZSI with DCM and CCM was discussed.

Generation of a 3D Artificial Joint Surface and Characterization of Its Roughness (삼차원 인공 절리면의 생성과 이에 대한 거칠기 특성 평가)

  • Choi, Seung-Beum;Lee, Sudeuk;Jeon, Seokwon
    • Tunnel and Underground Space
    • /
    • v.26 no.6
    • /
    • pp.516-523
    • /
    • 2016
  • Roughness of a joint surface is one of the most important parameters that affects the mechanical and hydraulic behavior of rock mass. Therefore, various studies on making constitutive model and/or roughness quantification have been conducted in experimental and empirical manners. Advances in recent 3D printing technology can be utilized to generate a joint surface with a specific roughness. In this study, a reliable technique to generate a rough joint surface was introduced and its quantitative assessment was made. Random midpoint displacement method was applied to generate a joint surface and the distribution of $Z_2$ was investigated to assess its roughness. As a result, a certain roughness can be embodied by controlling input parameters and furthermore it was able to generate a joint surface with specific roughness anisotropy.

Improvement of Bending Performances by Sloped Finger-Joint Method in Pinus densiflora S. et Z. (I) (경사핑거접합법에 의한 소나무재의 휨강도성능개량 (I))

  • Byeon, Hee-Seop;Park, Han-Min;Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.61-67
    • /
    • 1997
  • The bending performances of sloped finger-joints in Pinus densiflora S. et Z. were tested in order to improve the strength properties of finger-joint Sloped finger-cut pieces were jointed with four kinds of adhesives(resorcinol-phenol, oilic urethane, polyvinyl acetate, and polyvinyl-acryl acetate resin). The slope ratios of finger joints were 0, 0.5, 1.0, 2.0. The MOE, MOR and defletion to maximum load in bending of sloped finger-joints and solid wood specimen were measured. The results were: 1. The efficiencies of MOE to finger and sloped finger-joints were 82% or greater in every kind of adhesives except polyvinyl-acryl acetate resin adhesive and there were some effect of slope on the MOE in a sloped finger-joint for polyvinyl-acryl acetate and oilic urethane resin adhesives. 2. The effects of slope on the MOR to sloped finger-joints were showed in every kind of adhesive, because the efficiencies of MOR increased with increasing slope ratio in sloped finger-joints. The efficiencies of MOR to slope ratios of 0 and 2.0 ranged 43~65% and 76~82%, respectively. There was almost no effect of the kinds of adhesives on the MOR to the slope ratio of 2.0. 3. It was found impossible to estimate the bending strength of sloped finger-jointed Pinus densiflora S. et Z. by using MOE. The correlation coefficient(0.124) between MOE and MOR was very low and not significant at 5% level.

  • PDF

Sensitivity Analysis of Polarimetric Observations by Two Different Pulse Lengths of Dual-Polarization Weather Radar (펄스길이에 따른 이중편파변수의 민감도 분석)

  • Lee, Jeong-Eun;Jung, Sung-Hwa;Kim, Jong-Seong;Jang, KunIl
    • Atmosphere
    • /
    • v.29 no.2
    • /
    • pp.197-211
    • /
    • 2019
  • The observational sensitivity of dual-polarization weather radar was quantitatively analyzed by using two different pulse widths. For this purpose, test radar scan strategy which consisted of consecutive radar scan using long (LP: $2{\mu}s$) and short (SP: $1{\mu}s$) pulses at the same elevation angle was employed. The test scan strategy was conducted at three operational S-band dual-polarization radars (KSN, JNI, and GSN) of Korea Meteorological Administration (KMA). First, the minimum detectable reflectivity (MDR) was analyzed as a function of range using large data set of reflectivity ($Z_H$) obtained from JNI and GSN radars. The MDR of LP was as much as 7~22 dB smaller than that of SP. The LP could measure $Z_H$ greater than 0 dBZ within the maximum observational range of 240 km. Secondly, polarimetric observations and the spatial extent of radar echo between two pulses were compared. The cross-polar correlation coefficient (${\rho}_{hv}$) from LP was greater than that from SP at weak reflectivity (0~20 dBZ). The ratio of $Z_H$ (> 0 dBZ) and ${\rho}_{hv}$(> 0.95) bin to total bin calculated from LP were greater than those from SP (maximum 7.1% and 13.2%). Thirdly, the frequency of $Z_H$ (FOR) during three precipitation events was analyzed. The FOR of LP was greater than that of SP, and the difference in FOR between them increased with increasing range. We conclude that the use of LP can enhance the sensitivity of polarimetric observations and is more suitable for detecting weak echoes.

Improvement in efficiency and privacy on BCP public key cryptosystem (효율성과 사용자의 프라이버시가 개선된 BCP 공개키 암호시스템)

  • Youn Taek-Young;Park Young-Ho;Lim Jong In
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.15 no.6
    • /
    • pp.81-92
    • /
    • 2005
  • A novel public key cryptosystem that provides a double decryption mechanism is proposed at Asiacrypt '03 by Bresson, Catalano and Pointcheval based on the scheme proposed by Clamor and Shoup at Eurocrypt '02. Previous double decryrtion scheme is designed based on $Z_n^2$ where n=pq for two primes p,q. In this paper, we propose an efficient public key scheme with double decryption mechanism based on $Z_p^2_q$ for two primes p,q. Our scheme is more efficient an the previous schemes. Moreover, we review the previous schemes in a privacy point of view and propose a privacy enhanced double decryption scheme.

Follow-up Results of Z-plate Fixation in the Thoracolumbar Burst Fracture (흉요추 방출성 압박골절의 Z-plate를 이용한 고정술후 추적검사 결과)

  • Shim, Byeoung-Su;Kim, Keun-Su;Lee, Jung-Chung
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.6
    • /
    • pp.763-771
    • /
    • 2000
  • Objectives : Thoracolumbar burst fractures(TBLF) result in not only compressive deformity of vertebral body but also spinal cord compression by bony fragments. Many thoracolumbar burst fractures demand both anterior decompression and intervertebral fusion. Most of spinal surgeons use anterior instrumentation for anteior intervertebral bony fusion. The use of Z-plate has been increased recently, however there has been only a few reports regarding its clinical long-term strength. We studied nineteen patients with TBLF to find out the long-term stability of Z-plate. Methods : We have operated 19 patients from March 1996 to August 1998. They were treated with anterior decompression through either a transthoracic, retroperitoneal extrapleural or retroperitoneal approach. Retropulsed bony fragments were removed completely by corpectomy. Iliac bone graft was used for interbody fusion in all of the cases. They were evaluated by plain X-ray films including flexion and extention lateral films. Cobbs angle was used to evaluate kyphotic and lateral wedging deformity. Results : Burst fractured sites were T11 in two, three T12, nine L1, and five L2. Mean follow-up duration was fifteen months. Preoperative average kyphotic angle was 23.7 degree. Immediate postoperative kyphotic angle was 10.2 degree. Follow-up resluts of average kyphotic angles revealed 14 degrees. Four patients(21%), including two spinal 3-column injury, showed increasement of kyphotic angle more than 5 degree or breakage of intrumentation. Two patients showed the difference of kyphotic angle more than 3 degree. Five patients(26%) revealed lateral wedging deformity more than 3 degrees. Postoperative complications were two meralgia parestheticas, one pulmonary atelectasis and two donor site infections. Four of the eight patients, who initially showed incomplete spinal cord deficits, were nerologically improved by Frankel's grade. Conclusion : Z-plate fixation and iliac bone graft after anterior decompression in thoracolumbar burst fractures is a safe and easy method. Immediate postoperative results revealed excellent correction of posttraumatic kyphosis, but long-term follow-up evalution showed insufficient strength. Therefore we believe that use of Z-plate should be carefully decided, especially in the case of large lumbar fracture or 3-column injury.

  • PDF

A NEW METHOD TO MEASURE THE LINEAR POLYMERIZATION SHRINKAGE OF COMPOSITES USING A PARTICLE TRACKING METHOD WITH COMPUTER VISION (컴퓨터 시각과 입자 추적 방법을 이용한 복합레진의 선형중합수축 측정의 새로운 방법)

  • Lee, In-Bog;Min, Sun-Hong;Seo, Deog-Gyu;Kim, Sun-Young;Kwon, Young-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.180-187
    • /
    • 2010
  • Since the introduction of restorative dental composites, their physical properties have been significantly improved. However, polymerization shrinkage is still a major drawback. Many efforts have been made to develop a low shrinking composite, and silorane-based composites have recently been introduced into the market. In addition, many different methods have been developed to measure the polymerization shrinkage. In this study, we developed a new method to measure the linear polymerization shrinkage of composites without direct contact to a specimen using a particle tracking method with computer vision. The shrinkage kinetics of a commercial silorane-based composite (P90) and two conventional methacrylate-based composites (Z250 and Z350) were investigated and compared. The results were as follows: 1. The linear shrinkage of composites was 0.33-1.41%. Shrinkage was lowest for the silorane-based (P90) composite, and highest for the flowable Z350 composite. 2. The new instrument was able to measure the true linear shrinkage of composites in real time without sensitivity to the specimen preparation and geometry.

Composition and Activity of the Asiatic Leafroller, Archippus breviplicanus(Lepidoptera: Tortricidae) Sex Pheromone at Apple Orchards in Korea (사과원에서의 사과무늬잎말이나방(Archippus breviplicanus)의 성페로몬 조성과 활성)

  • 정충렬;한경식;정진교;최경희;이순원;부경생
    • Korean journal of applied entomology
    • /
    • v.40 no.3
    • /
    • pp.219-226
    • /
    • 2001
  • To identity the composition and ratio of the sex pheromone in the asiatic leafroller, Archippus breviplicanus (Walsingham), which is a major pest on apple leaves, and to develop a monitoring system using this sex pheromone, abdominal tips of their virgin female during the calling period were extracted and analysed. The GC/GC-MS analysis revealed the following three compounds; (E)11-tetradecenyl acetate (E11-14: Ac), (Z)11-tetradecenyl acetate (Z11-14: Ac), and tetradecyl acetate(14: Ac) with the ratio of 56:22:22. Electroantennogram (EAG) assay was also conducted to examine biological activity of the components. The three components evoked significantly higher responses than hexane or air but there was no significant differences between the mixtures made by components. Field trapping experiments for determining the optimum blend, seasonal fluctuation and the optimum amount for male attracting were carried out over 4 years from 1997 to 2000. Although male moths were attracted to 8:2 and 7:3 between E11-14: Ac and Z11-14: Ac, their 7:3 blend was found to be the most effective. Archippus breviplicanus appears to occur three times a year in Korea. The optimum amount for monitoring was found to be 1mg per trap. 14: Ac, the third component, did not show synergistic effect on male moth attraction.

  • PDF

Distribution of Magnetic Field Depending on the Current in the μ-turn Coil to Capture Red Blood Cells (적혈구 포획용 미크론 크기 코일에 흐르는 전류의 크기에 따른 자기장 분포 특성)

  • Lee, Won-Hyung;Chung, Hyun-Jun;Kim, Nu-Ri;Park, Ji-Soo;Lee, Sang-Suk;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.5
    • /
    • pp.162-168
    • /
    • 2015
  • The ${\mu}$-turn coil having a width of ${\mu}m$ on the GMR-SV (giant magnetoresistance-spin valve) device based on the antiferromagnetic IrMn layer was fabricated by using the optical lithography process. In the case of GMR-SV film and GMR-SV device, the magnetoresistance ratios and the magnetic sensitivities are 4.4%, 2.0%/Oe and 1.6 %, 0.1%/Oe, respectively. In the y-z plane the distribution of magnetic field of GMR-SV device and $10{\mu}$-turns coil which put under the several magnetic bead(MB)s with a diameter of $1{\mu}m$ attached to RBC (red blood cell) was analyzed by the computer simulation using the finite element method. When the AC currents of 20 kHz from 0.1 mA to 10.0 mA flow to the 10 turns ${\mu}$-coil, the magnetic field at the position of $z=0{\mu}m$ at the center of coil was calculated from $30.1{\mu}T$ to $3060{\mu}T$ in proportion to the current. The magnetic field at the position of $z=10{\mu}m$ was decreased to one-sixth of that of $z=0{\mu}m$. It was confirmed that the $10{\mu}$-turn coil having enough magnitude of magnetic field for the capture of RBC is possible to use as a biosensor for the detection of magnetic beads attached to RBC.