• Title/Summary/Keyword: $TcpCO_2$

Search Result 52, Processing Time 0.029 seconds

Synthesis of Hydroxyapatite Powders by Homogeneous Precipitation Method and Their Thermal Changes (균일침전법을 이용항 Hydroxyapatite 분말의 제조 및 가열변화)

  • Lee, Jin-Ho;Park, Hoon;Kim, Chang-Eun
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.1
    • /
    • pp.7-16
    • /
    • 1996
  • ${CO_3}^{2-}$ containing whisker-like hydroxyapatite powders were synthesized byhomogeneous precipitation method using urea, Dicalcium phosphate anhdrate[DCPA; $CaHPO_4$] and octacalcium phosphate [OCP; $Ca_8H_2(PO_4_)6\cdot5H_20$]were obtained as precursors and they transformed to high crystalline hydroxyapatites at pH 5.62, and 6.54 respectively. According to the condition of the final pH in the solutions for the solution products and urea contents OCP was remained. When the solution product of $Ca^{2-}$ and ${PO_4}^{3-}$ was $1.5\times 10^4$[$mM^2$] and the content of urea was 0.25 mol.$dm^{-3}$ well crystallized whisker-like hydroxyapatite tens of micrometer in length was obtained. By heat treatment DCPA and OCP were decomposed into $\beta$-tricalcium phosphate [$\beta$-TCP ; $\beta$-$Ca_3{PO_4}_2$] and $\beta$-dicalcium phosphate [$\beta$-DCP ;$\beta$-$Ca_2P_2O_4}_2$]. And well-crystallized hydroxyapatite was partially decomposed into $\beta$-TCP at $800^{\circ}C$.

  • PDF

A study on the street security light management system using Zigbee network (지그비 통신망을 이용한 보안등 관제 시스템에 관한 연구)

  • Jeon, Joong Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.430-436
    • /
    • 2014
  • This paper relates to the study about the street security light management system. The purpose of the wireless remote management system is to manage street security lights efficiently. The system is composed of three components like light controller, CDMA gateway and web based remote management server. The zigbee solution is adopted to make local wireless network between street security lights. The CDMA network is used for the wireless communication between street security light controller and the remote control center. The gateway to interconnect zigbee network and CDMA was designed with low power 32 bits Cortex M3 micro-controller. For the data communication between the management server and the gateway, SMS and socket based TCP streaming is used. The management server sends SMS to the gateway to deliver light control and management requests, and the gateway replies with the light controllers report via TCP streaming. By using both SMS and TCP streaming communication, it was verified that simple cost effective management is possible for street security lights. We tried real test for 95 street security lights in real environment during two months and analyzed the practical possibility for mass supply.

Synthesis and characterization of silicon ion substituted biphasic calcium phosphate (실리콘 이온이 첨가된 biphasic calcium phosphate의 합성 및 특성평가)

  • Song, Chang-Weon;Kim, Tae-Wan;Kim, Dong-Hyun;Park, Hong-Chae;Yoon, Seog-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.5
    • /
    • pp.243-248
    • /
    • 2010
  • Si-substituted biphasic calcium phosphates (Si-BCP) were prepared by co-precipitation method. X-ray diffraction and fourier transform infrared spectroscopy were used to characterize the structure of Si-BCP powders. The Si-BCP powders with various Ca/(P+Si) molar ratio were carried out on structural change of hydroxyapatite (HAp) and ${\beta}$-tricalcium phosphate ($\ss$-TCP). The in-vitro bioactivity of the Si-BCP powders was determined by immersing the powders in SBF solution, after that observing the chemical composition and morphology change by X-ray diffraction, scanning electron microscope and energy dispersive spectroscopy.

Non-invasive Transcutaneous pCO2 Gas Monitoring System for Arterial Blood Gas Analysis

  • Bang, Hyang-Yi;Kang, Byoung-Ho;Eum, Nyeon-Sik;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.311-316
    • /
    • 2011
  • Monitoring the carbon dioxide concentration in arterial blood is vital for the evaluation and prevention of pulmonary disease. Yet, domestic pure arterial blood carbon dioxide sensor technologies are not being developed, instead all sensors are imported. In this paper, we develop a real time monitoring system for arterial blood partial pressure of carbon dioxide($pCO_2$) gas from the wrist by using a carbon micro-heater. The micro-heater was fabricated with a thickness of 0.3 ${\mu}m$ in order to collect the carbon dioxide under the skin. The micro-heater has been designed to perform temperature compensation in order to prevent damage to the skin. Two clinical trials of the system were undertaken. As a result, we demonstrated that a portable, transcutaneous carbon dioxide analysis($TcpCO_2$) device produced domestically is possible. In addition, this system reduced the analysis time significantly. Carbon films could reduce the unit price of these sensors by replacing the gold film used in foreign models. Also, we developed a real time monitoring system which can be used with optical biosensors for medical diagnostics as well as gas sensors for environmental monitoring.

A System Development for Remotely Controlling Windows and Doors in Mobile Environment (모바일 환경에서의 원격 창호 관제시스템 개발)

  • Cho, Yong-Hyun;Ryu, Sung-Won;Ahn, Kyung-Gyu
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.4
    • /
    • pp.334-341
    • /
    • 2015
  • This paper develops a new system for remotely monitoring and controlling the windows and doors in mobile environment. We design and implement the opening and shutting unit, the gateway, and the control server system, respectively. The opening and shutting unit consists of the driver using DC motor and the motion controller which monitors the state and transfers the control information. The gateway supports TCP/IP and CDMA protocol, which is the interface of wire and wireless communication for transferring the current state and control information. The control server consists of the program to store and process the control information, the middleware to support the processing of various state message, and DB for monitoring the state and remotely controlling the system. Especially, an application software and the Web-based user interface have also been developed to support the mobile environment. The operation performances, environment influences, driving persistences, and operation failure ratio, which are based on PC and smart-phone, have been tested in 2 authorized agencies. The test results show that the developed system has a superior performance.

Clinical Outcomes of Arthroscopic Rotator Cuff Repair Using Poly Lactic-co-glycolic Acid Plus β-tricalcium Phosphate Biocomposite Suture Anchors

  • Chung, Seok Won;Oh, Kyung-Soo;Kang, Sung Jin;Yoon, Jong Pil;Kim, Joon Yub
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.1
    • /
    • pp.22-29
    • /
    • 2018
  • Background: This study is performed to evaluate anchor-related outcomes and complications after arthroscopic rotator cuff repair using 30% ${\beta}$-tricalcium phosphate (${\beta}$-TCP) with 70% poly lactic-co-glycolic acid (PLGA) biocomposite suture anchors. Methods: A total of 78 patients (mean age, $61.3{\pm}6.9years$) who underwent arthroscopic medium-to-large full-thickness rotator cuff tear repair were enrolled. The technique employed 30% ${\beta}$-TCP with 70% PLGA biocomposite suture anchors at the medial row (38 patients, Healix $BR^{TM}$ anchor [Healix group]; 40 patients, Fixone anchor B [Fixone group]). The radiologic outcomes (including perianchor cyst formation or bone substitution) and anatomical outcomes of the healing failure rate were evaluated using magnetic resonance imaging at least 6 months after surgery, the pain visual analogue scale at 3, 6 months, and final follow-up visit, and American Shoulder and Elbow Surgeons scores at least 1 year postoperatively. Anchor-related complications were also evaluated. Results: The perianchor cyst formation incidence was similar for both groups (60.5%, Healix group; 60.0%, Fixone group; p=0.967), although severe perianchor cyst incidence was slightly lower in the Fixone group (15.0%) than in the Healix group (21.1%). There was no occurrence of anchor absorption and bone substitution. No differences were observed in the healing failure rate (13.2%, Healix group; 15.0%, Fixone group; p=0.815) and functional outcome between groups (all p>0.05). Anchor breakage occurred in 5 patients (2 Healix anchors and 3 Fixone anchors); however, there were no major anchor-related complications in either group. Conclusions: No differences were observed in the clinical outcomes of the Healix and Fixone groups, neither were there any accompanying major anchor-related complications.

Fabrication and Cell Culturing on Carbon Nanofibers/Nanoparticles Reinforced Membranes for Bone-Tissue Regeneration

  • Deng, Xu Liang;Yang, Xiao Ping
    • Carbon letters
    • /
    • v.13 no.3
    • /
    • pp.139-150
    • /
    • 2012
  • Poly-L-lactic acid (PLLA), PLLA/hydroxyapatite (HA), PLLA/multiwalled carbon nanotubes (MWNTs)/HA, PLLA/trifluoroethanol (TFE), PLLA/gelatin, and carbon nanofibers (CNFs)/${\beta}$-tricalcium phosphate (${\beta}$-TCP) composite membranes (scaffolds) were fabricated by electrospinning and their morphologies, and mechanical properties were characterized for use in bone tissue regeneration/guided tissue regeneration. MWNTs and HA nanoparticles were well distributed in the membranes and the degradation characteristics were improved. PLLA/MWNTs/HA membranes enhanced the adhesion and proliferation of periodontal ligament cells (PDLCs) by 30% and inhibited the adhesion of gingival epithelial cells by 30%. Osteoblast-like MG-63 cells on the randomly fiber oriented PLLA/TEF membrane showed irregular forms, while the cells exhibited shuttle-like shapes on the parallel fiber oriented membrane. Classical supersaturated simulated body fluids were modified by $CO_2$ bubbling and applied to promote the biomineralization of the PLLA/gelatin membrane; this resulted in predictions of bone bonding bioactivity of the substrates. The ${\beta}$-TCP membranes exhibit good biocompatibility, have an effect on PDLC growth comparable to that of pure CNF membrane, and can be applied as scaffolds for bone tissue regeneration.

Exhaust Gas Analysis System (배출가스 검사시스템)

  • Kim, Gwan-Hyung;Oh, Am-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.544-545
    • /
    • 2015
  • 오늘날 자동차에서 배출되는 유해 가스로 인한 지구 온난화를 막기 위하여 많은 환경규제를 받고 있다. 때문에 대부분의 국가들은 출시되는 자동차나 운행 중인 자동차에 대하여 배출가스 검사를 의무적으로 실시하여 배출가스에 의한 대기오염을 줄일 수 있도록 법제화하고 있다. 본 논문에서는 "배출가스 검사/진단시스템" 개발에 대한 고찰을 통하여 배출가스, RPM, 소음을 측정할 수 있는 MCU(micro controller unit) 기반의 데이터 계측기에 대한 설계방안을 제시하고자 한다. 또한, MCU를 기반으로 배출가스(HC, CO, CO2 등) 데이터 확보를 위한 광학 필터처리 기술 및 신호처리 알고리즘을 검토하였다. 자동차의 RPM을 측정할 수 있는 알고리즘에 대한 검토와 배출가스 및 소음을 측정할 수 있는 알고리즘을 개발하여 RS-485, TCP/IP 기반으로 데이터를 전송할 수 있는 배출가스 검사시스템을 제시하고자 한다.

  • PDF

Bioactivity behavior of Si and Mg ion-substituted biphasic calcium phosphate powders (Si 및 Mg 이온이 교환된 biphasic calcium phosphate 분말의 생체활성 거동)

  • Kim, Tae-Wan;Kim, Dong-Hyun;Jin, Hyeong-Ho;Lee, Heon-Soo;Park, Hong-Chae;Yoon, Seog-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.2
    • /
    • pp.92-98
    • /
    • 2012
  • The co-precipitation technique has been applied to synthesize biphasic calcium phosphate (BCP). $Ca(NO_3)_2{\cdot}4H_2O$, $(NH_4)_2HPO_4$, TEOS and $Mg(NO_3)_2{\cdot}6H_2O$ as the starting materials was used. After the heat treatment of powder crystalline phases HAp and ${\beta}$-TCP analysis showed a mixed phase. The overall spectra appear to have mainly two modes corresponding to characteristic $PO^{3-}_4$ and $OH^-$ groups. After immersion in Hanks' Balanced Salt Solution (HBSS) for 1 week a precipitation started to be formed with individual small granules on the specimen surface. An MTT assay indicated that ionic substituted BCP powders had no cytotoxic effects on MG-63 cells, and that they have good biocompatibility.

Effects of Gas Chemistries on Poly-Si Plasma Etching with I-Line and DUV Resist (I-Line과 DUV Resist에서 Poly-Si 플라즈마 식각시 미치는 개스의 영향)

  • 신기수;김재영
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.2
    • /
    • pp.155-160
    • /
    • 1998
  • It is necessary to use Arc layer and DUV resist to define 0.25 $\mu \textrm{m}$ line and space for 256 MDRAM devices. Poly-Si etching with Arc layer and different resists has been performed in a TCP-9408 etcher with variation of gas chemistries; $Cl_2/O_2, Cl_2/N_2, Cl_2$/HBr . DUV resist causes more positive etch profile and CD gain compared to I-line resist because the sidewall passivation is more stimulated by increasing polymerization through the loss of resist. When Arc layer is applied, CD hain also increases due to the polymeric mask formed after thching Arc layer. From the point of gas chemistry effects, the etch profile and CD gain is not improved using $Cl_2/O_2$ gas, since polymerization is accelerated in this gas. however, the vertical profile and less CD gain is obtained using $Cl_2$/HBr gas. Furthermore, HBr gas is very effective to suppress the difference of profile and CD variation between dense pattern and isolated pattern by minimizing non-uniformity of side wall passivation with pattern density.

  • PDF