실시간 Igr 검출을 위한 센서 모듈의 제작 및 신뢰성 평가에 관한 연구 (A Study on the Fabrication of the Sensor Module for the Detection of Resistive Leakage Current (Igr) in Real Time and Its Reliability Evaluation)

  • 이병설;최충석
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.28-34
    • /
    • 2018
  • The purpose of this study is to fabricate a sensor module to detect the resistive leakage current (Igr) in real time that occurs to low voltage electric lines and to verify its reliability. In the case of the developed sensor module, wires are inserted into the zero current transformer (ZCT) and current transformer (CT) in advance and then the branch line is connected to the circuit breaker. The measurement result of the resistance of the distribution panel equipped with the developed sensor module shows that the resistance is $0.151m{\Omega}$ between the R and R phases, $0.169m{\Omega}$ between the S and S phases, and $0.178m{\Omega}$ between the T and T phases, respectively. The insulation resistance measured at AC 500 V and 1,000 V is $0.08m{\Omega}$ between the R, S, T and N phases, respectively. Then, the insulation resistance measured at DC 500 V is $83.3G{\Omega}$ between the R, S, T and G terminal, respectively. In addition, the applied withstanding voltage is AC 220 V/380 V/440 V and it was found that characteristics between all phases are good. This study measured the standby power by installing the developed sensor module at the rear of the MCCB and switching the circuit breaker on sequentially. The standby power is 1.350 W when one circuit breaker is turned on, 1.690 W when 2 circuit breakers are turned on, and 4.371 W when 10 circuit breakers are turned on. This study also verified the reliability of the standby power of the distribution panel equipped with the developed sensor module using the Minitab Program (Minitab PGM). Since the analysis shows the statistical average of 1.34627 in the reliable range of normal distribution, standard deviation of 0.001874, AD of 0.554, and P value of 0.140, it is found that the distribution panel equipped with the developed sensor module has high reliability.

유전 및 압전특성에 따른 LCD Backlight용 압전 트랜스포머의 출력전력특성 (Output Power characteristics of the Piezoelectric Transformer for LCO Backlight with Piezoelectric and Piezoelectric Properties)

  • 민석규;류주현;정회승;홍재일;윤현상;손은영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.852-856
    • /
    • 2000
  • In this paper, we investigated the output power, step-up ratio and efficiency properties of piezoelectric transformer with dielectric and piezoelectric characteristics of manufactured ceramics. The piezoelectric transformers with $2.0$\times$10$\times$48[$mm^3$] size were fabricated and its electrical properties were measured. When output power of 6W was constantly maintained, T2 piezoelectric transformer showed the minimum temperature rise of $9(^{\circ}C)$ at $150(K\Omega)$ load resistance. However, T1 piezoelecric transformer showed the temperature rise of $7.2(^{\circ}C)$ at $200(K\Omega)$ load resistance. The 6[w] CCFL (Cold Cathode Fluorescent Lamp) was successfully driven by T1 and T2 piezoelectric transformer but, its temperature rise $\Delta$T[$^{\circ}C)$] was generated more than $20(^{\circ}C)$. It is concluded that we have to design the piezoelectric transformers so that its output impedance correspond to the load impeadance, including any stray capacitance.

  • PDF

The Counting Processes that the Number of Events in [0,t] has Generalized Poisson Distribution

  • Park, Jeong-Hyun
    • Journal of the Korean Data and Information Science Society
    • /
    • 제7권2호
    • /
    • pp.273-281
    • /
    • 1996
  • It is derived that conditions of counting process ($\{N(t){\mid}t\;{\geq}\;0\}$) in which the number of events in time interval [0, t] has a (n, n+1)-generalized Poisson distribution with parameters (${\theta}t,\;{\lambda}$) and a generalized inflated Poisson distribution with parameters (${\{\lambda}t,\;{\omega}\}$.

  • PDF

H형(形) 강(鋼) 보의 횡좌굴(橫挫屈)에 관(關)한 연구(硏究) (A Study On Lateral Buckling Of H-Section Steel Beams)

  • 김석중
    • 산업기술연구
    • /
    • 제4권
    • /
    • pp.29-35
    • /
    • 1984
  • Buckling is a significant behavior to be considered whenever we design steel structures. In the case of H-shape beams, the lateral buckling occured by bending moment must be considered. Because of the lateral buckling of H-shape beams, the bending strength of the beams are determined by the lateral buckling stress instead of the allowable bending stress. Lateral buckling stress equation, consisting of two terms, i. e. ${\sigma}_{cr}({\nu},{\omega})={\sqrt{[{\sigma}_{cr}({\nu})]^2+[{\sigma}_{cr}({\omega})]^2}}$ has been using, but for the practical purpose of use the following equations are using two, i. e. ${\sigma}_{cr}({\nu})={\frac{0.65E}{{\ell}_h/A_f}}$, ${\sigma}_{cr}({\omega})={\frac{{\pi}^2E}{({\ell}_b/i_b)^2}}$. When we use the above equations, the results are different according to the shape of beam section, and they a re rather complex. In this study lateral buckling stress equation is derived, and the proposed formula$({\sigma}_{cr}(t))$ is compared with above mentioned two basic and practical equations. To verify the proposed formula experimentaly, 16H-shape beams which have different slender ratios arc tested by applying pure bending momet. Through the experiments the buckling behavior of H-shape beams is clarified, and the results shows that the proposed formula$({\sigma}_{cr}(t))$ is accurate enough for practical purpose.

  • PDF

웨이블렛 변환에 의한 파형 해석 (Waveform Analysis Using Wavelet Transform)

  • 김희준
    • 자원환경지질
    • /
    • 제28권5호
    • /
    • pp.527-533
    • /
    • 1995
  • A disadvantage of Fourier analysis is that frequency information can only be extracted for the complete duration of a signal f(t). Since the Fourier transform integral extends over all time, from $-{\infty}$ to $+{\infty}$), the information it provides arises from an average over the whole length of the signal. If there is a local oscillation representing a particular feature, this will contribute to the calculated Fourier transform $F({\omega})$, but its location on the time axis will be lost There is no way of knowing whether the value of $F({\omega})$ at a particular ${\omega}$ derives from frequencies present throughout the life of f(t) or during just one or a few selected periods. This disadvantage is overcome in wavelet analysis which provides an alternative way of breaking a signal down into its constituent parts. The main advantage of the wavelet transform over the conventional Fourier transform is that it can not only provide the combined temporal and spectral features of the signal, but can also localize the target information in the time-frequency domain simultaneously. The wavelet transform distinguishes itself from Short Time Fourier Transform for time-frequency analysis in that it has a zoom-in and zoom-out capability.

  • PDF

Optimal Sputtering Parameters of Transparent Conducting ITO Films Deposited on PET SUbstates

  • Kim, Hyun-Hoo;Shin, Sung-ho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제1권2호
    • /
    • pp.23-27
    • /
    • 2000
  • Indium in oxide(ITO) films have been deposited on PET and glass substrates by DC reactive magnetron sputtering without post-deposition thermal treatment, The high quality for microstructure, electrical and optical properties of the as-deposited ITO films on unheated substrates is dominated by the sputtering parameters, The influence of the working gas pressure, DC power and oxygen partial pressure has been systematically investigated, The lowest DC power, and oxygen partial pressure has been systematically investigated, The lowest resistivity of ITO films deposited on PET substrates was 6$\times$10$^{-4}$ $\Omega$cm. It has been obtained at a working pressure of 3 mTorr and DC power of 30 W. The sheet resistance and optical transmittance of these film were 22 $\Omega$/square and 84% respectively. The best values of figures of merit for the electrical and optical characteristics such as T/ $R_{sh}$ and $T^{10}$ / $R_{sh}$ are approximately 38.1 and 7.95($\times$10$^{-3}$ $\Omega$$^{-1}$ ), respectively.

  • PDF

Effect of $Ca^{2+}-channel$ Blockers on Norepinephrine Release in the Rat Hippocampal Slice and Synaptosome

  • Kim, Suk-Won;Jung, Kyu-Yong;Choi, Bong-Kyu
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제6권2호
    • /
    • pp.87-91
    • /
    • 2002
  • The aim of this study was to investigate the role of $Ca^{2+}-channel$ blockers in norepinephrine (NE) release from rat hippocampus. Slices and synaptosomes were incubated with $[^3H]-NE$ and the releases of the labelled products were evoked by 25 mM KCl stimulation. Nifedipine, diltiazem, nicardipine, flunarizine and pimozide did not affect the evoked and basal release of NE in the slice. But, diltiazem, nicardipine and flunarizine decreased the evoked NE release with a dose-related manner without any change of the basal release from synaptosomes. Also, a large dose of pimozide produced modest decrement of NE release. ${\omega}-conotoxin$ (CTx) GVIA decreased the evoked NE release in a dose-dependent manner without changing the basal release. And ${\omega}-CTxMVIIC$ decreased the evoked NE release in the synaoptosomes without any effect in the slice, but the effect of decrement was far less than that of ${\omega}-CTxGVIA.$ In interaction experiments with ${\omega}-CTxGVIA,\;{\omega}-CTxMVIIC$ slightly potentiated the effect of ${\omega}-CTxGVIA$ on NE release in the slice and synaptosomal preparations. These results suggest that the NE release in the rat hippocampus is mediated mainly by N-type $Ca^{2+}-channels,$ and that other types such as L-, T- and/or P/Q-type $Ca^{2+}-channels$ could also be participate in this process.