• Title/Summary/Keyword: $SF_6$ Mixture Gas

Search Result 88, Processing Time 0.024 seconds

Analysis of AC Breakdown Voltage accoding to epoxy thickness of Composite Insulation for Dry-Air/Epoxy under non-uniform electric field (불평등전계에서의 건조공기/에폭시 복합절연물의 에폭시 두께에 따른 AC 파괴전압 분석)

  • Heo, Jun;Lee, Seung-Su;Lim, Kee-Joe;Jung, Hae-Eun;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.113-114
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

Analysis of AC Breakdown Voltage of Composite Insulation for Dry-Air/Epoxy (건조공기/에폭시 복합절연물의 AC 파괴전압 분석)

  • Heo, Jun;Lee, Seung-Su;Lim, Kee-Joe;Jung, Hae-Eun;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.289-290
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

50% Flashover Voltage and V-t Characteristics for $SF_6-N_2$ Mixtures under Positive & Negative Ligtning Impulse Voltage ($SF_6-N_2$ 혼합가스의 정.부극성 뇌충격전압에 대한 50% FOV와 V-t 특성)

  • Song, W.P.;Kim, J.D.;Koh, H.S.;Kim, D.O.;Kwon, Y.H.;Cho, K.B.;Lee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.300-303
    • /
    • 1991
  • Sulphur-hexafluoride has extensively been used as an insulating gas of electric power equipment in substation for its high dielectric strength, non-toixity and non-flammable properties. But it is very expensive and is liquidizable under the condition of low temperature and high pressure. And it is very sensible to the locally high electric field strength. To resolve these problems, we studied 50% FOV and V-t characteristics of $SF_6-N_2$ mixtures under positive and negative lightning impulses using a 25mm rod-plane gap. 50% FOV of $SF_6-N_2$ 50% mixture was about 85% of pure $SF_6$ and it was known that $SF_6-N_2$ mixtures can be used as an economic substitution insulating gas for $SF_6$.

  • PDF

The Phase Transition and the Surface Flashover Characteristics of $SF_6$ ($SF_6$의 상전이에 따른 연면방전특성)

  • Choi, Eun-Hyeok;Lee, Jung-Hwan;Park, He-Rir;Jang, Seung-Ho;Woo, Sung-Hun;Park, Kwang-Seo;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.267-269
    • /
    • 2009
  • In this paper, insulations characteristics by temperature changes($+10{\sim}-60[^{\circ}C]$) of $SF_6$ 9as in the experimental chamber were studied. From this result, The breakdown characteristics classify the gas & liquid coexisted stage of voltage value increases & much deviation and the $V_B$ low stage as the interior of chamber gets filled with mixture of $SF_6$ that are not liquefacted and remaining air which couldn't be ventilated. In addition the ability of insulation of liquid $SF_6$ was higher than that of the highly pressurized $SF_6$ gas. In this research, we want to provide the base data on designing insulation of high-temperature superconductor and the cryogenic equipments by investigating the insulation characteristics of $SF_6$.

  • PDF

Distribution Function and Drift Velocities in Mixtures of SF6 and Ar (SF6-Ar 혼합기체의 전자분포함수와 이동속도)

  • Kim, Sang-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.146-150
    • /
    • 2010
  • Distribution Function and Drift velocities for electrons in $SF_6$-Ar mixtures gases used by MCS-BEq algorithm has been analysed over the E/N range 30~300[Td] by a two term Boltzmann equation and by a Monte Carlo simulation using a set of electron cross sections determined by other authors, experimentally the electron swarm parameters for 0.2[%] and 0.5[%] $SF_6$-Ar mixtures were measured by time-of-flight method. The results obtained in this work will provide valuable information on the fundamental behaviors of electrons in weakly ionized gases and the role of electron attachment in the choice of better gases and unitary gas dielectrics or electro negative components in dielectric gas mixtures. The results show that the deduced electron drift velocities agree reasonably well with theoretical for a rang of E/N values.

Analysis of electron transport properties in $SF_6$+He mixture gas used by MCS-BE (MCS-BE에 의한 $SF_6$+He 혼합기체의 전자수송특성 해석)

  • 하설철;송병두;유회영;김상남;백승권
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.359-364
    • /
    • 2000
  • The paper describes the electron transport characteristics in SP$_{6}$+He gas calculated E/N values 0.1~700[Td] by the Monte Carlos simulation and Boltzmann equation method using a set of electron collision cross sections determined by the authors and the values of electron swarm parameters obtained by TOF method. This study gained the values of the electron swarm parameters such as the electron drift velocity the electron ionization or attachment coefficients longitudinal and transverse diffusion coefficients for SF$_{6}$+He gas at a range of E/N.E/N.

  • PDF

Surface Discharge Characteristics of Teflon Resin in Environment-Friendly Insulation Gas (친환경 절연가스중 Teflon수지의 연면방전특성)

  • Lee, Jung-Hwan;Park, He-Rie;Choi, Eun-Hyeok;Jang, Seong-Ho;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.121-127
    • /
    • 2009
  • This paper reviews a basic data of the surface discharge characteristics for tefton resin in not only pure $N_2$, $N_2:O_2$(80[%]:20[%], I-Air) and $N_2:O_2$(60[%]:40[%]) mixture gas as environment-friendly insulation Gas also $SF_6$. Used electrodes are Knife to Knife. With the changing distance of electrodes and pressure, we can find it, surface discharge voltages and surface dielectric strengths, respectively. Surface discharge Voltages of I-Air are more higher than the other $N_2/O_2$ mixture gases. Moreover, we can obtain that the surface dielectric strengths of $SF_6$ are two times about I-Air, approximately.

Raman Spectroscopy and Molecular Modeling Study on the CH4 and SF6 Mixture Gas Hydrate Growth Behavior (라만 분광학과 분자모델링을 이용한 메탄 및 육불화황 혼합 가스 하이드레이트 성장 거동 연구)

  • Lim, Jun-Heok;Lee, Ju Dong;Park, Sung Soo;Eom, Ki Heon;Won, Yong Sun
    • Clean Technology
    • /
    • v.19 no.4
    • /
    • pp.476-480
    • /
    • 2013
  • The growth behavior of $CH_4$ and $SF_6$ mixture gas hydrate has been investigated by a combined approach of Raman spectroscopy and molecular modeling. Raman spectroscopy results presented that when $CH_4$ is used only, $CH_4$ guest molecule is inserted first into the large cavity of the host structure built by $H_2O$ molecules and then into the small cavity to stabilize the whole gas hydrate structure. In the other hand, when $SF_6$ is mixed together, $SF_6$ is favored over (or competing with) $CH_4$ in being inserted into the large cavity and the small cavity still prefers $CH_4$ insertion. The calculations of binding energies clearly supported this. While $SF_6$ has a binding energy of -26.9 kcal/mol a little lower than -24.2 kcal/mol of $CH_4$ in the large cavity, $SF_6$ and $CH_4$ has 1.2 kcal/mol and -22.0 kcal/mol, respectively, in the small cavity. It indicates that the sizable $SF_6$ is not preferred in the small cavity but has a relative energetic advantage over $CH_4$ in the large cavity.

Breakdown Characteristics of $SF_6-N_2$ Mixtures under Uniform and Non uniform Electricc Field (평등/불평등 전계에서 $SF_6-N_2$ 혼합가스의 절연파괴 특성연구)

  • Seo, C.S.;Lee, J.S.;Kim, J.T.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2299-2301
    • /
    • 1999
  • In this work, experimental investigation was carried out for the breakdown characteristics of $SF_6$, $N_2$ and their mixtures under the uniform and non-uniform electric field, by use of HVAC and standard impulse testing voltages, as a function of different gas pressures from 1 atm to 5 atm. The results show that the dielectric strength of the $SF_6$ mixed in $N_2$ was significantly increased at its portion of 10%, which might imply that the optimum mixture of $SF_6$ for the HV switch gear could be proposed to be 10%.

  • PDF

Study on the Gas Separation of Carbon Molecular Sieve (CMS) Membrane for Recovering the Perfluorocompound Gases from the Electronics Industry (전자산업 배출 불화가스 회수를 위한 탄소분자체 분리막의 기체분리 연구)

  • Jeong, Su Jung;Lim, Joo Hwan;Han, Sang Hoon;Koh, Hyung Chul;Ha, Seong Yong
    • Membrane Journal
    • /
    • v.26 no.3
    • /
    • pp.220-228
    • /
    • 2016
  • Carbon molecular sieve (CMS) hollow fiber membranes were prepared by carbonizing a polyimide precursor manufactured by non-solvent induced phase separation process. Gas separation performance of CMS hollow fiber membrane was investigated on the effect of three carbonization conditions. CMS membrane with the highest gas separation performance was obtained at the pyrolysis temperature of $250-450^{\circ}C$: $N_2$, $SF_6$, and $CF_4$ permeance were 20, 0.32, 0.48 GPU, respectively, and $N_2/SF_6$ and $N_2/CF_4$ selectivities were 62 and 42, respectively. In the $SF_6/CF_4/N_2$ mixture gas test, when the stage cut was 0.2, the recovery ratio of $SF_6$ and $CF_4$ was over 99% and 98%. $SF_6$ concentration ratio was 4.5 times higher than the $SF_6$ concentration at the feed side. From the results, it was concluded that CMS membrane was one of the promising membranes for recovery Perfluorocompound gases process.