• 제목/요약/키워드: $PM_{10}$ concentrations

검색결과 2,173건 처리시간 0.031초

대기오염과 실내 거주자의 활동도가 교실 내부의 입자 크기별 먼지 농도에 미치는 영향 (The Effect of Outdoor Air and Indoor Human Activity on Mass Concentrations of Size-Selective Particulate in Classrooms)

  • 최상준
    • 한국환경보건학회지
    • /
    • 제34권2호
    • /
    • pp.137-147
    • /
    • 2008
  • This study evaluated the effects of the human activity and outdoor air on concentrations of size-selective particulate matters (PM) by conducting a realtime measurement in classrooms and on roofs at 4 elementary schools, 3 middle schools and 3 high schools in Incheon City. PM concentrations featured repetitive pattern of increasing during break time (including lunch hours) and cleaning time while decreasing during class hours. This trend was more prominent with inhalable PM and PM10 than fine PMs (PM2.5, PM1.0). The indoor/outdoor (I/O) ratio of inhalable PM and PM10 exceeded 1 while that of fine PMs was close to or below 1. The PM2.5 (out)/PM10 (out) ratio stood at 0.59 (${\pm}0.16$) and the PM2.5 (in)/PM10 (in) ratio was 0.29 (${\pm}0.09$), suggesting that occupant activity had a greater effect upon coarse particles (PM10-PM2.5) than upon fine particles (PM2.5, PM1.0). The correlations between the indoor and the outdoor PM concentrations showed a stronger positive correlation for fine particles than that of coarse particles. The linear regression analysis of PM concentrations indoor and outdoor indicated a higher determinant coefficient ($r^2>0.9$), and consistency for fine particles than in case of coarse particles. In conclusion, the results of this study suggest that the indoor coarse particle concentration is more attributed to occupant activity and the indoor fine particle concentration is more influenced by outdoor air pollution.

서울시 미세먼지 농도의 지역적 특성파악을 위한 연구 - 구별 분포 특성 및 차량등록대수와의 관계 - (Understanding on Regional Characteristics of Particular Matter in Seoul - Distribution of Concentration in Borough Spatial Area and Relation with the Number of Registered Vehicles -)

  • 박종길;최윤정;정우식
    • 한국환경과학회지
    • /
    • 제26권1호
    • /
    • pp.55-65
    • /
    • 2017
  • Average concentration of PM in Seoul metropolitan area satisfied the Korean air quality standard in 2010. Furthermore, concentration of PM in all boroughs across Seoul met the air environment standard in 2012. $PM_{10}$ concentration was relatively higher in center of Seoul in comparison to the rest, while $PM_{2.5}$ concentration showed exactly the contrary result. We analyzed the effect that PM emissions from vehicles would have on PM concentrations across Seoul. The results showed that average annual PM concentration recently decreased in Seoul although the number of vehicles registered annually continued its upward trend. By contrast, average fine dust concentrations in Seoul showed a decline which suggested that correlation between annual average PM concentrations and number of registered vehicles remained low. However, year-on-year vehicle registration rate recently showed a declining tendency in the same way as the trend of changes in average PM concentrations. Particularly, the upward trend in annual average PM concentrations in 2002 and 2007 was consistent with the increase in vehicle registration rate, suggesting that vehicle registration rate was closely associated with changes in PM concentrations.

제주 고산 조대입자와 미세입자의 질량, 질산염, 황산염 변화와 고농도 특성 (Source Signature of Mass, Nitrate and Sulfate in Supermicron and Submicron Aerosols at Gosan Superstation on Jeju Island)

  • 임세희;이미혜;이강웅;강경식
    • 대기
    • /
    • 제20권3호
    • /
    • pp.221-228
    • /
    • 2010
  • Aerosol particles with different size-cuts ($PM_{10}$, $PM_{2.5}$, and $PM_{1.0}$) were collected at Gosan Superstation on Jeju Island from August 2007 to June 2008. Mean concentrations of $PM_{10}$, $PM_{2.5}$ and $PM_{1.0}$ were $29.28{\mu}gm^{-3}$, $17.83{\mu}gm^{-3}$, and $14.30{\mu}gm^{-3}$, respectively. Soluble ions comprised 45.7%, 53.9%, and 60.3% of the total mass of $PM_{10}$, $PM_{2.5}$, and $PM_{1.0}$, respectively. While sulfate was the most dominant species of fine mode ($PM_{1.0}$), nitrate was enriched in coarse mode ($PM_{1.0-10}$). When the concentrations of coarse mode particles were greatly increased, nitrate tended to be enhanced in coarse mode with high calcium but low sulfate concentrations. During the high $PM_{1.0}$ events, however, nitrate was increased with sulfate at fine mode. Particularly, nitrate concentrations were substantially enhanced during high particle episodes, leading high ratios of nitrate to sulfate in air under northwest wind during wintertime. On the other hand, the levels of nitrate were lower than those of sulfate at average particle concentrations. The backward air mass trajectories indicated that nitrate concentrations were elevated in air arriving Gosan passing through Santung peninsula or near South Korea.

봄철 황사 전후 산악연안도시, 강릉시에서 PM1, PM2.5, PM10의 농도비교 (Comparison of PM1, PM2.5, PM10 Concentrations in a Mountainous Coastal City, Gangneung Before and After the Yellow Dust Event in Spring)

  • 최효
    • 한국환경과학회지
    • /
    • 제17권6호
    • /
    • pp.633-645
    • /
    • 2008
  • In order to investigate the variations and corelation among $PM_{10},\;PM_{2.5}\;and\;PM_1$ concentrations, the hourly concentrations of each particle sizes of 300nm to $20{\mu}m$ at a city, Gangneung in the eastern mountainous coast of Korean peninsula have been measured by GRIMM aerosol sampler-1107 from March 7 to 17, 2004. Before the influence of the Yellow Dust event from China toward the city, $PM_{10},\;PM_{2.5}\;and\;PM_1$, concentrations near the ground of the city were very low less than $35.97{\mu}g/m^3,\;22.33{\mu}g/m^3\;and\;16.77{\mu}g/m^3$, with little variations. Under the partial influence of the dust transport from the China on March 9, they increased to $87.08{\mu}g/m^3,\;56.55{\mu}g/m^3\;and\;51.62{\mu}g/m^3$. $PM_{10}$ concentration was 1.5 times higher than $PM_{2.5}$ and 1.85 times higher than $PM_1$. Ratio of $(PM_{10}-PM_{2.5})/PM_{2.5}$ had a maximum value of 1.49 with an averaged 0.5 and one of $(PM_{2.5}-PM_1)/PM_1$ had a maximum value of 0.4 with an averaged 0.25. $PM_{10}\;and\;PM_{2.5}$ concentrations were largely influenced by particles smaller than $2.5{\mu}m\;and\;1{\mu}m$ particle sizes, respectively. During the dust event from the afternoon of March 10 until 1200 LST, March 14, $PM_{10},\;PM_{2.5}\;and\;PM_1$ concentrations reached $343.53{\mu}g/m^3,\;105{\mu}g/m^3\;and\;60{\mu}g/m^3$, indicating the $PM_{10}$ concentration being 3.3 times higher than $PM_{2.5}$ and 5.97 times higher than $PM_1$. Ratio of $(PM_{10}-PM_{2.5})/PM_{2.5}$ had a maximum value of 7.82 with an averaged 3.5 and one of $(PM_{2.5}-PM_1)/PM_1$, had a maximum value of 2.8 with an averaged 1.5, showing $PM_{10}\;and\;PM_{2.5}$ concentrations largely influenced by particles greater than $2.5{\mu}m\;and\;1{\mu}m$ particle sizes, respectively. After the dust event, the most of PM concentrations became below $100{\mu}g/m^3$, except of 0900LST, March 15, showing the gradual decrease of their concentrations. Ratio of $(PM_{10}-PM_{2.5})/PM_{2.5}$ had a maximum value of 3.75 with an averaged 1.6 and one of $(PM_{2.5}-PM_1)/PM_1$ had a maximum value of 1.5 with an averaged 0.8, showing the $PM_{10}$ concentration largely influenced by corse particles than $2.5{\mu}m$ and the $PM_{2.5}$ by fine particles smaller than $1{\mu}m$, respectively. Before the dust event, correlation coefficients between $PM_{10},\;PM_{2.5}\;and\;PM_1$, were 0.89, 0.99 and 0.82, respectively, and during the dust event, the coefficients were 0.71, 0.94 and 0.44. After the dust event, the coefficients were 0.90, 0.99 and 0.85. For whole period, the coefficients were 0.54, 0.95 and 0.28, respectively.

Estimation of ambient PM10 and PM2.5 concentrations in Seoul, South Korea, using empirical models based on MODIS and Landsat 8 OLI imagery

  • Lee, Peter Sang-Hoon;Park, Jincheol;Seo, Jung-young
    • 농업과학연구
    • /
    • 제47권1호
    • /
    • pp.59-66
    • /
    • 2020
  • Particulate matter (PM) is regarded as a major threat to public health and safety in urban areas. Despite a variety of efforts to systemically monitor the distribution of PM, the limited amount of sampling sites may not provide sufficient coverage over the areas where the monitoring stations are not located in close proximity. This study examined the capacity of using remotely sensed data to estimate the PM10 and PM2.5 concentrations in Seoul, South Korea. Multiple linear regression models were developed using the multispectral band data from the Moderate-resolution imaging spectro-radiometer equipped on Terra (MODIS) and Operational Land Imager equipped on Landsat 8 (Landsat 8) and meteorological parameters. Compared to MODIS-derived models (r2 = 0.25 for PM10, r2 = 0.30 for PM2.5), the Landsat 8-derived models showed improved model reliabilities (r2 = 0.17 to 0.57 for PM10, r2 = 0.47 to 0.71 for PM2.5). Landsat 8 model-derived PM concentration and ground-truth PM measurements were cross-validated to each other to examine the capability of the models for estimating the PM concentration. The modeled PM concentrations showed a stronger correlation to PM10 (r = 0.41 to 0.75) than to PM2.5 (r = 0.14 to 0.82). Overall, the results indicate that Landsat 8-derived models were more suitable in estimating the PM concentrations. Despite the day-to-day fluctuation in the model reliability, several models showed strong correspondences of the modeled PM concentrations to the PM measurements.

고정배출원의 먼지 크기별 (PM, PM10, PM2.5) 배출 특성 연구 (The Characterization of PM, PM10, and PM2.5 from Stationary Sources)

  • 김종호;황인조
    • 한국대기환경학회지
    • /
    • 제32권6호
    • /
    • pp.603-612
    • /
    • 2016
  • The objective of this study was to estimate the emission characteristics for PM, $PM_{10}$, and $PM_{2.5}$ in the various stationary sources. The particulate matters collected in the various stationary sources such as power plants (Coal and B-C oil), incinerators(municipal and industrial waste), and glass furnaces. The PM and $PM_{10}$, PM and $PM_{2.5}$, $PM_{10}$ and $PM_{2.5}$ samples were collected using the cyclone type $PM_{10}$, $PM_{2.5}$ samplers and 30 species(19 inorganic species, 9 ionic species, OC and EC) were analyzed by ICP, IC, and TOR/IMPROVE methods. The mass concentrations of PM, $PM_{10}$, $PM_{2.5}$ from nine stationary sources ranged $0.63{\sim}9.58mg/Sm^3$, $0.26{\sim}7.47mg/Sm^3$ and $0.13{\sim}6.34mg/Sm^3$, respectively. The level of $PM_{10}$, $PM_{2.5}$ portion in PM calculated 0.63~0.99, 0.38~0.94, respectively. In the case of emission trend for species, power plant showed high concentrations for Al, Mg, Na, Si, V and $SO_4{^{2-}}$, respectively. Also, Ca, Fe, K, Si, $Cl^-$, and $K^+$ showed high in incinerator. In the case of glass furnace, Na, Pb, K, Si, $Na^+$ and $SO_4{^{2-}}$ represented high concentrations. Power plant showed higher EC/OC concentrations than other sampling sites. These results suggest the possible role for complement establishment process of emission inventory and emission management for PM.

다단입자채집기와 입자계수기 자료를 이용한 서울 에어러솔 밀도 계산 (Aerosol Density Determined Using Micro-orifice Uniform Deposit Impactor and Aerosol Dust Monitors Data at Seoul)

  • 김정은;이해영
    • 한국대기환경학회지
    • /
    • 제26권3호
    • /
    • pp.298-304
    • /
    • 2010
  • In order to calculate the aerosol bulk densities of $PM_{1.0}$ and $PM_{10}$, aerosol mass and number concentrations were measured for the period of December 2008~April 2009. $PM_{1.0}$ and $PM_{10}$ mass concentrations were measured using a cascade impactor (Micro-Orifice Uniform Deposit Impactor, MOUDI) while their volume concentrations were calculated based on number concentrations from an environmental dust monitor (EDM). Normal aerosol size distribution fitting functions were retrieved for number size distribution since aerosols < $2.5{\mu}m$ were measured from the EDM. Strong correlation was found between $PM_{1.0}$ mass and volume concentrations obtained with a $R^2$ of 0.95. The calculated average bulk densities of $PM_{1.0}$ and $PM_{10}$ were $1.97{\pm}0.33g/cm^3$ and $2.15{\pm}0.18g/cm^3$, respectively.

산란광 광량 적산시 Digital Dust Indicator에 의한 도서관과 학생회관내 $PM_{10}$ 농도의 일변화 (Diurnal Variation of $PM_{10}$ Concentrations in Library and Student Buildings using Scattering Light Integrated Type Digital Dust Indicator)

  • 김만구;권영진;정영림
    • 한국대기환경학회지
    • /
    • 제13권2호
    • /
    • pp.115-122
    • /
    • 1997
  • Diurnal variation of $PM_{10}$ concentration was investigated for 24 sites in library including reading room, bookstock room, lobby, office and so on, and 9 sites in student building at Kangwon National University using scattering light integrated type digital dust indicator. The dimensional conversion factors for mass concentrations (K) were determined by comparing between the $PM_{10}$ concentrations collected by $PM_{10}$ hig volume air sampler and the digital dust indicator. The dimensional conversion factor (K) was 3.33 for indoor air in this experiment. The highest concentrations were 649 $\mug/m^3$/day for smoking room in the library and 242 $\mug/m^3$/day for circle room in the student building. Most of spaces in the library except a office and bookstock rooms were over 150 $\mug/m^3$/day of $PM_{10}$ concentrations and 6 indoor spaces were over the guideline for indoor air quality in student building except a health center and two restaurants. Therefore, it should be required to make an improvement on the indoor air quaility for public facilities in the university buildings.

  • PDF

Relationship between Peripheral Plasma Inhibin and Progesterone Concentrations in Sahiwal Cattle (Bos Indicus) and Murrah Buffaloes (Bubalus bubalis)

  • Mondal, S.;Prakash, B.S.;Palta, P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권1호
    • /
    • pp.6-10
    • /
    • 2003
  • The present study investigated peripheral plasma immunoreactive inhibin (ir-inhibin) concentrations in relation to the stage of oestrous cycle and progesterone concentrations in cycling Sahiwal cattle (Bos indicus) and Murrah buffaloes (Bubalus bubalis). Blood samples were collected once daily for thirty-two consecutive days from cattle and buffaloes (5 each) during winter months of January and February. Mean (${\pm}$S.E.M.) plasma ir-inhibin concentrations ranged from $0.40{\pm}0.01$ to $0.59{\pm}0.03ng/ml$ in cattle and from $0.29{\pm}0.03$ to $0.52{\pm}0.05ng/ml$ in buffaloes. In cattle, ir-inhibin concentrations increased from $0.47{\pm}0.07ng/ml$ on day -4 (day 0=day of oestrus) to reach a maximum value of $0.59{\pm}0.03ng/ml$ on day -2. Thereafter, ir-inhibin concentrations showed a decline to reach a low of $0.40{\pm}0.01ng/ml$ on day 11 of the oestrous cycle. In buffaloes, ir-inhibin concentrations increased from $0.38{\pm}0.04 ng/ml$ on day -4 to reach a maximum concentration of $0.52{\pm}0.05ng/ml$ on day -2. Ir-inhibin concentrations then declined to reach a low of $0.29{\pm}0.03ng/ml on day 9 of the cycle. In both cattle and buffaloes, ir-inhibin concentrations which were lowest ($0.43{\pm}0.02$ and $0.34{\pm}0.02ng/ml$, respectively) during the mid-luteal phase of the oestrous cycle increased (p<0.05) to $0.52{\pm}0.03$ and $0.44{\pm}0.04ng/ml$, respectively, during the late luteal phase, and then further to the highest value of $0.53{\pm}0.02$ and $0.49{\pm}0.04ng/ml$, respectively, during the perioestrus phase, following which these declined to $0.50{\pm}0.02$ and $0.39{\pm}0.03ng/ml$, respectively, during the early luteal phase. The variations in peripheral plasma ir-inhibin profile in both the species appear to be related to the changes in characteristics of follicular populations during the oestrous cycle. Peripheral plasma ir-inhibin concentrations were negatively correlated with progesterone concentrations in cattle (r=-0.51, p<0.01) and buffaloes (r=-0.30, p<0.01) indicating that the corpus luteum is not a source of peripheral ir-inhibin in these species.

PSCF 모델을 활용한 부산지역 PM10의 발생원 추정 (Estimation of PM10 source locations in Busan using PSCF model)

  • 도우곤;정우식
    • 한국환경과학회지
    • /
    • 제24권6호
    • /
    • pp.793-806
    • /
    • 2015
  • The purpose of this study is to find out the air flow patterns affecting the PM10 concentration in Busan and the potential sources within each trajectory pattern. The synoptic air flow trajectories are classified into four clusters by HYSPLIT model and the potential sources of PM10 are estimated by PSCF model for each cluster from 2008 to 2012. The potential source locations of PM10 are compared with the distribution of PM10 anthropogenic emissions in east Asia developed in 2006 for the NASA INTEX-B mission. The annual mean concentrations of PM10 in Busan decreased from $51ug/m^3$ in 2008 to $43ug/m^3$ in 2012. The monthly mean concentrations of PM10 were high during a spring season, March to May and low during a summer season, August and September. The cluster2 composed of the air trajectories from the eastern China to Busan through the west sea showed the highest frequency, 44 %. The cluster1 composed of the air trajectories from the inner Mongolia region to Busan through the northeast area of China showed the second high frequency, 26 %. The cluster3 and 4 were composed of the trajectories originated in the southeast sea and the east sea of Busan respectively and showed low frequencies. The concentrations of in each cluster were $47ug/m^3$ in cluster1, $56ug/m^3$ in cluster2, $42ug/m^3$ in cluster3 and $37ug/m^3$ in cluster4. From these results, it was proved that the cluster1 and 2 composed of the trajectories originated in the east and northeast area of China were the causes of high PM10 concentrations in Busan. The results of PSCF and CWT model showed that the potential sources of the high PM10 concentrations were the areas of the around Mongolia and the eastern China having high emissions of PM10 from Beijing, Hebei to Shanghai through Shandong, Jiangsu.