• 제목/요약/키워드: $LN_2$(Liquid Nitrogen)

검색결과 146건 처리시간 0.023초

Double Pancake Coil형 고온초전도 변압기의 전기적 절연 특성 (Dielectric Insulation Properties of Double Pancake Coil Type HTS Transformer)

  • 백승명;정종만;이현수;한철수;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제16권2호
    • /
    • pp.151-156
    • /
    • 2003
  • High temperature superconductor can only be applied against an engineering specofication that has to be determined for each particular application form the design requirements for economic viability and for operation margins in service. However, in order to realize the HTS transformer, it is necessary to establish the high voltage insulation technique in cryogenic temperature. Therefore, the composite insulation of double pancake coil type transformer are described and AC breakdown voltage characteristics of liquid nitrogen(LN$_2$) under HTS pancake coil electrode made by Bi-2223/Ag are studied. The Breakdown of LN$_2$ is dominated electrode shape and distance. The influence of pressure on breakdown voltage is discussed with th different electrode. For the electrical insulation design of turn-to-turn insulation for the HTS transformer, we tested breakdown strength of insulation sheet under varying pressure. And we investigated surface flashover properties of LN$_2$ and complex conition of cryogenic gaseous nitrogen(CGN$_2$) obove a LN$_2$ surface. The surface voltage of GFRP was measured as a function of thickness and electrode distance in LN$_2$ and complex condition of CGN$_2$ above a LN$_2$ surface. this research presented information of electrical insulation design for double pancake coil(DPC) type HTS transformer.

Double Pancake Coil형 고온초전도 변압기의 전기적 절연 설계를 위한 절연파괴 특성 (Breakdown Properties for Electrical Insulation Design of Double Pancake Coil Type HTS Transformer)

  • 백승명;정종만;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.52-57
    • /
    • 2002
  • High temperature superconductors can only be applied against an engineering specification that has to be determined for each particular application form the design requirements for economic viability and for operation margins in service. However, in order to realize the HTS transformer, it is necessary to establish the high voltage insulation technique in cryogenic temperature. Therefore, the composite insulation of double pancake coil type transformer are described and ac breakdown voltage characteristics of liquid nitrogen($LN_{2}$) under HITS pancake coil electrode made by Bi-2223/Ag are studied. Breakdown in $LN_{2}$ is dominated electrode shape and distance. And we investigated AC breakdown properties of $LN_{2}$ and complex conition of cryogenic gaseous nitrogen($CGN_{2}$) obove a $LN_{2}$ surface. Also, the surface voltage of GFRP was measured as a function of thickness and electrode distance in $LN_{2}$ and complex condition of $CGN_{2}$ above a $LN_{2}$ surface. This research presented information of electrical insulation design for double pancake coil type HTS transformer.

  • PDF

극저온 전력케이블을 액체질소에 대한 방전특성에 관한 연구 (A study on the discharge characteristics of liquid nitrogen using at cryogenic cable)

  • 이현동;주재현;박원주;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1996년도 추계학술발표회논문집
    • /
    • pp.125-129
    • /
    • 1996
  • This study describes that electrical breakdown of liquid nitrogen which is influenced with bubble has been investigated as liquid nitrogen is used coolant of high temperature(T/sub c/) superconductivity. In order to investigate breakdown of liquid nitrogen, we formed electrode system of parallel and vertical configuration toward gravitutional direction. In case of changing with electrode configuration of equal electrode and gap spacing in uniform and nonuniform electric field bubble behavior is changed. In result of that, breakdown voltage is changed. Therefore, this study proved that electrode configuration must be formed the smallest existing probability of bubble between two electrodes in order to increase breakdown strength of liquid nitrogen at atmosphere pressure.

  • PDF

액체질소 중 FRP의 절연파괴 및 연면방전 특성 연구 (Breakdown and Surface Flashover Characteristics of FRP in $LN_2$)

  • 정종만;백승명;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.119-123
    • /
    • 2002
  • In this study, we discussed the characteristics of breakdown and surface flashover of FRP in L$N_2$ for applying it to spacer of a superconducting power equipment. Fiberglass reinforced plastic(FRP) has high breakdown puncture strength and has high mechanical strength. So the research of its dielectric properties have been conducted in liquid nitrogen($LN_2$). We measured breakdown voltage of FRP and distinguished four types of surface flashover along solid insulator with arrangement of electrodes and measured the surface flashover voltages of each types of electrode arrangement. The type of a electrode set at the back of the insulator showed the worst dielectric property. The property of surface flashover depending on pressure was tested.

THERMAL SYSTEM DESIGN FOR A LARGE SPACE $SIMULATOR(\Phi8m\;\times\;L10m)$

  • Moon Guee-Won;Cho Chang-Lae;Cho Hyokjin;Lee Sang-Hoon;Seo Hee-Jun;Choi Seok-Weon
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.281-284
    • /
    • 2004
  • According to the National Space Program of Korea, KARI (Korea Aerospace Research Institute) has been developing a large space simulator (working dimension; $\Phi8m\;\times\;L10m$) to verify the performance of future large satellites under the space environment conditions. Especially, a very low temperature condition of space will be simulated by shrouds covering the inside surface of the vessel. The surface of shrouds will be cooled down to 17K by liquid nitrogen (LN2) from ambient temperature and hence, an optimal LN2 circulation system design is necessary to remove gaseous nitrogen (GN2) sufficiently and maintain the shrouds at the LN2 temperature.

  • PDF

대기압하의 액체질소중 전극배치에 따른 고체유전체 표면의 연면방전 및 Tracking현상 (The Characteristics of Tracking Phenomena and Surface Discharge Using Various Types of Electrode Arrangement in LN2 at the Atmospheric Pressure)

  • 박광서;신호영;최병주;박원주;이광식
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.49-55
    • /
    • 2003
  • 본 논문에서는 고온 초전도체의 냉매로서 주목받고 있는 액체질소 중에서 고체절연물 표면의 연면 방전과 트래킹 현상에 관하여 연구하였다 액체질소중 연면 방전에 많은 영향을 주는 기포 효과를 연구하기 위해 Knife형태의 전극과 평판형태의 전극을 사용하여 A-mod, B-mode, C-mode의 전극배치형태를 각각 구성하였다. 본 실험의 결과는 향후 연구되고 개발될 초전도·극저온 전력설비의 절연설계의 기초 데이터를 제공할수 있다고 판단된다.

컴퓨터 시스템에 의한 대기압하(大氣壓下)에서 액체질소($LN_2$)의 방전특성측정(放電特性測定) (Measurement of the discharge characteristics of liquid nitrogen at atmospheric pressure by personal computer system)

  • 주재현;이영근;김상구;전영주;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1530-1532
    • /
    • 1994
  • This paper describes the discharge characteristics of liquid nitrogen for plane-plane, needle-plane electrode at variation of gap spacing at atmospheric pressure. The important results obtained from this study are as follows. (1) Breakdown voltage of $LN_2$ for needle-plane electrode is higher than that of for plane-plane electrode and discharge duration tine is longer with increase of gap spacing at atmospheric pressure. (2) The formation of bubbles by evaporation is observed in spite of non-applying source at atmospheric pressure and the creation of corona confirmed for plane-plane electrode results from the bubbles. (3) The applied voltage-discharge magnitude( V-Q) characteristics of $LN_2$ showed hysteresis and the discharge magnitude decreasing and corona voltage increasing proportional to the pulse per second at atmospheric pressure.

  • PDF

대기압하의 액체질소중 전극배치에 따른 고체유전체 표면의 연면방전 및 Tracking현상 (The Characteristics of Tracking Phenomena and Surface Discharge Using Various Types of Electrode Arrangement in $LN_{2}$ at the Atmospheric Pressure)

  • 박경태;신호영;박광서;최병주;이광식;이동인
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.114-118
    • /
    • 2002
  • This paper were investigated discharge characteristics in the Liquid Nitrogen($LN_{2}$) noticed as a cooling medium of high temperature superconductor, and the characteristics of surface discharge and tracking phenomena on the solid insulators of cryocable. In order to investigate the bubbles which have much influence on electric surface discharge in Liquid Nitrogen, knife type electrode and plane electrode was formed oppositely with mode A and B, C configuration. It is considered that these result are fundamental data for electric insulation design of superconductivity and cryogenic application machinery which will be studied and developed in the future.

  • PDF

대기압하에서 액체질소(LN2)방전특성에 관한 연구 (A study on the discharge characteristics of liquid nitrogen at atmospheric pressure)

  • 이영근;주재현;김상구;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1993년도 추계학술발표회논문집
    • /
    • pp.58-62
    • /
    • 1993
  • This paper shows the discharge characteristics of liquid nitrogen under plane to plane electrode, needle to plance electrode, inserting teflon insulator in plane to plane electrode at atmospheric pressure. The main experimental device of this paper is cryostat. The important results obtained from this study are sa follows. Breakdown voltage of LN2 under N-P electrode is higher than that of under P-P electrode at atmospheric pressure. Breakdown duration time is longer with increase of electode gap under the P-P, N-P electrodes. The formation of bubbles by evaporation is observed in spite of non-applying source at atmospheric pressure and the creation of corona confirmed. Breakdown voltage and breakdown duration time are in proportion to increase of diameter in case of inserting teflon insulator. Partial discharge characteristics of thickness 0.5[mm] is that 채굼 voltage of teflon insulator rose with increase of diameter in each [pps].

  • PDF

고온초전도 기기응용을 위한 모의 퀜치 환경에서 액체질소의 절연파괴 특성 (Electrical Breakdown characteristics of $LN_2$ under simulated Quenching conditions for application of HTS apparatus)

  • 백승명;정종만;이정원;곽동순;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.187-191
    • /
    • 2002
  • The characteristics of Electrical breakdown liquid nitrogen($LN_2$) were studied under simulated Quenching conditions for application of HTS apparatus. The experimental results for various quench condition revealed that the breakdown voltage of $LN_2$ with bubble flow velocity and gap spacing, Also, it did a electric field and potential distribution interpreting at the liquid nitrogen when the bubble existed, The plots of equipotential lines for three cases are also shown.

  • PDF