• Title/Summary/Keyword: $CO_2$ supply

Search Result 768, Processing Time 0.026 seconds

Unit-Rectangle Exposure Method for Advanced Through-put in Electron-Beam Direct Writing Lithography (전자선 직접묘사에서 Through-put이 향상된 단위 矩形묘사방법)

  • Park, Sun-Woo;Kim, Chul-Ju
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.112-117
    • /
    • 1989
  • This paper describes to the unit rectangle EB direct writing lithography method using SEM. This method has the constant exposure time to any rectangle pattern. In order to change the EB current according to various rectangle size for the constant exposure time, the supply current of condenser lens in controlled by BITMAP-IV CAD system. By this method, the resizing procedure of density pattern area is not needed to pattern data conversion, and the through-put ofr exposure is increased about 172 times compared with the unit scan exposure method.

  • PDF

A Study on the Design and Realization of the VHF Transmitter for Air Traffic Control (항공관제용 VHF대역 송신기 설계 및 구현에 관한 연구)

  • Park, Wook-Ki;Kang, Suk-Youb;Park, Hyo-Dal
    • Journal of Advanced Navigation Technology
    • /
    • v.9 no.2
    • /
    • pp.121-130
    • /
    • 2005
  • In this paper, we designed and fabricated the VHF wireless transmitter for air traffic control. Fundamental performance of the investigated wireless transmitter is designed and fabricated to satisfy existing commercial wireless transmitter specification for air traffic control. 25 W and 50 W of output power can be generated by changing the power amplification part only. It is based on transmitting voice communication using AM modulation. Investigated wireless transmitter for air traffic control consists of four module parts: power supply, control, low power transmission and power amplification. We designed 1W transmitter to operate without power amplification part. It can be used properly in a basic component of CNS/ATM.

  • PDF

Strength properties of non-cement board for drying shrinkage control using industrial by-products (산업부산물을 활용한 건조수축 제어용 무시멘트 보드의 강도특성)

  • Park, Ju-Hwa;Pyeon, Su-Jeong;Lee, Dong-Hoon;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.228-229
    • /
    • 2018
  • In the construction industry, we have set goals such as reduction of greenhouse gas emissions and reduction of energy use. In particular, reduction of CO2 emissions in the concrete manufacturing process, reduction of industrial waste and industrial wastes into concrete The zero-emission level of reuse as a resource is under review. On the other hand, the cost of stone is expensive due to small quantity production of domestic stone production in order, it is difficult to carry and construct with heavy material, and it takes long time to construct. In order to solve the shortage of supply and demand of natural stone, various kinds of stone powder, artificial stone made by putting stone texture on the surface of mortar or concrete, fiber reinforced plate, tiles and the like are increasingly used. In this study, the artificial stone using slag and recycled aggregate instead of natural stone was fabricated and the strength characteristics were evaluated for its applicability and feasibility.

  • PDF

Determining Appropriate Capacity on Installing Photovoltaic System at Deteriorated Educational Facilities

  • Lhee, Sang Choon;Choi, Young Joon;Choi, Yool
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.23-29
    • /
    • 2014
  • With high acknowledgements of environmental conservation and energy saving, many architectural technologies using renewable energy have been recently applied at buildings which take about 20% of total energy consumption. Among renewable energy sources, the photovoltaic is considered as the most highly potential one due to advantages of infiniteness and cleanliness. Also, projects to install renewable energy systems have been continuously performed at deteriorated educational facilities as energy efficient remodeling projects or green school projects by the Korean government. This paper proposes appropriate capacities by school level on installing photovoltaic systems at deteriorated school buildings, based on the balance of annual electricity power demand and supply between buildings and systems. Using the Visual DOE program and Merit program, the appropriate installment capacity of photovoltaic system turned out be 40kWp at elementary school building and 60kWp at middle and high ones. In addition, annual energy use proved to be reduced by 20.2% at elementary school, 26.9% at middle school, and 21.0% at high school by installing photovoltaic systems with the appropriate capacities.

A Prediction of Hybrid Ventilation System Performance in Apartment House (공동주택 하이브리드(Hybrid) 환기시스템의 성능예측)

  • Hwang, Ji-Hyeon;Oh, Chang-Yong;Choi, Hung-Won;Kim, Moo-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.33-38
    • /
    • 2005
  • A hybrid ventilation system was introduced to predict the ventilation performance of the apartments. This ventilation system was composed of the natural supply-air inlet and the forced exhaust-air outlet. Analysis was conducted by CFD technique and was performed on three ventilating flow rates; 30, 60, 120 $m^3/h$. As the results, residents feel comfortable thermally and in air flow conditions for 60 $m^3/h$. But the case of 30 $m^3/h$ shows 1100ppm of $CO_2$ concentration due to the deficient of air flow rate. In the case of 120 $m^3/h$, however, residents feel uncomfortable thermally and in air currents. In this study the energy saving for space heating is also an important factor. A detailed prediction for more complicated whole apartment space will be investigated in the future.

  • PDF

A Study on the Flow Characteristic for Changing of Flow Region of the Motor Inserted Oil Pump (내부 유로 변경에 따른 전동기 일체형 유압펌프 내부의 유동특성에 관한 연구)

  • Choi, Y.H.;Lee, T.K.;Lee, Y.W.
    • Journal of Power System Engineering
    • /
    • v.16 no.5
    • /
    • pp.26-31
    • /
    • 2012
  • A numerical study has been carried out to investigate the heat and mass transfer of an oil pumping system with a variable shape of the housing using the CFD method. Especially, the electric motor and the pump combined together, accomplishes a research about the oil supplying system. In this study, the temperature and velocity distribution of the oil pumping system by varying the flow rate of supplying oil have been investigated. The temperature changes with each five conditions(flow rate of supply oil : 2, 4, 8, 12, and 16 liter/min) have also been studied. The numerical results show that the exhaust temperature decreases as the flow rate of the supplying oil increases. It also reveals that the temperatures change differently with the housing shape.

Conceptual Design Strategy of Renewable Energy Application for Building Certification and Mandatory System (신재생에너지설비 건물설치 의무화 및 인증제를 고려한 용량설계 방안)

  • Lee, Kyoung-Ho;Lee, Dong-Won;Kown, Hyeok-Min;Lee, Chang-Jun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.99-104
    • /
    • 2011
  • This paper describes a design strategy at conceptual design stage using RETScreen software tool for building application of renewable energy resources. Currently, government and public buildings are required to adopt renewable energy systems with a minimum requirement for the amount of renewable energy supply. Meanwhile, there is a certificate program for private office buildings to enhance propagation of renewable energy systems. When considering application of renewable energy systems to a building, it is worthwhile developing a method to determine optimal design sizes of renewable energy systems. In the paper, a design strategy is introduced with a couple of case studies to determine optimal capacities of each renewable energy system in a building and suggest to use the method to evaluate the system for the building certificate program and the mandatory renewable target program. Objective functions considered in the study are initial system cost and reduction of CO2 emissions from the system. In the optimization study, it is assumed that solar thermal collectors are installed to satisfy solar fraction of 60%. Other renewable energy systems such as ground-source heat pump, solar PV and non-renewable systems such as electric chiller and gas-fired boiler are sized using an optimal sizing method with RETScreen suggested the authors previously.

  • PDF

Industry safety characteristic of Prismatic EDLCs (각형 전기이중층 커패시터의 산업 안전성)

  • 김경민;장인영;강안수
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.05a
    • /
    • pp.247-257
    • /
    • 2004
  • Electrodes were fabricated based on activated carbon powder BP-20, conducting agent such as Super P, vapor grown carbon fiber (VGCF) and acetylene black (AB), and the mixed binders of flexible poly(vinylidenefluoridehexafluoropropylene) [P(VdF-co-HFP)] and cross linking dispersion agent of polyvinylpyrrolidone (PVP) to increase mechanical strength. According to impedance measurement of the electrode with the addition of conducting agent, we found that it was possible to charge rapidly by the fast steady-state current convergence due to low equivalent series resistance (AC-ESR, fast charge transfer rate at interface between electrode and electrolyte and low RC time constant. The self-discharge of unit cell showed that diffusion process was controlled by the ion concentration difference of initial electrolyte due to the characteristics of Electric Double Layer Capacitor (EDLC) charged by ion adsorption in the beginning, but this by current leakage through the double-layer at the electrode/electrolyte interface had a minor effect and voltages of curves were remained constant regardless of electrode material. We found that the 2.3V/230F grade EDLC would be applied to industrial safety usage such as uninterrupted power supply (UPS) because of the constant DC-ESR by IR drop regardless of discharge current.

  • PDF

A Study on the As Low As Reasonably Practicable (ALARP)-Concept Risk Assessment of Silane in Semiconductor and LCD Process (반도체/LCD 제조공정에서의 Silane에 대한 ALARP개념의 화재 폭발 위험성평가에 관한 연구)

  • Lee, Joong-Hee;Hwang, Seong-Min;Woo, In-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.93-98
    • /
    • 2010
  • 본 연구에서는, 반도체, LCD 공정에서 금속막을 증착하기 위하여 PECVD장비에 화재, 폭발 위험성과 독성을 가진 Silane가스를 사용하게 되는 장비인 gas cabinet, pipeline, VMB(Valve manifold box), MFC(mass flow controller)장비 등, 전반적인 시스템에 대하여 영국 HES의 ALARP개념을 도입하여 위험성 평가를 실시하여 문제점을 도출하고 대책을 강구 하는데 목적이 있고, 여러 가지 문제점중 절대적으로 수용 할 수 없는 Critical Risk로는 Gas Cylinder를 사용하여 Silane을 공급하고자 할 때에는 필히 Gas Cabinet을 사용하여 공급하여야 하고, Tube Trailer를 사용하여 공급하고자 할 때에는 필수적으로 Purge System을 갖추어 공급하여야 한다. 선택적으로 수용할 수 있는 High, Medium Risk로는 Gas Cylinder 또는 Tube Trailer를 사용하여 Silane을 공급하고자 할 때는 Inlet 부분에 RFO(Resticted Flow Orifice)를 설치하여 사용하고 Gas Supply Room에는 CO2소화설비를 적용하지 말고 Water Mist등 물 분무설비를 적용하여야한다.

The Effect on the Combustion and Emission Characteristics of HCNG Engine According to the High Purity Hydrogen Contents (고순도 수소함량에 따른 HCNG 연소특성 및 배출가스 영향 평가)

  • Lee, Jong-Tae;Lim, Yun-Sung;Kim, Hyung-Jun;Lee, Seong-Wook;Lee, Jang-Hoon;Kim, Jong-Geu
    • Journal of ILASS-Korea
    • /
    • v.17 no.3
    • /
    • pp.152-157
    • /
    • 2012
  • This investigation decribes the effect of the combustion and emission characteristics of HCNG engine according to the high purity hydrogen contents. The HCNG fuel was made by the mixture with a high purity hydrogen ($H_2$) and a natural gas. The test vehicle was applied to the bi-fuel (Gasoline and CNG) system and this system was modified from the fuel supply and fuel tank. In addition, the three premixed HCNG fuels with mixed rate of 10, 20 and 30% of hydrogen were used to maintain the safety. In order to analyze the combustion characteristics of HCNG and CNG, the fuel was injected in the combustor with constant volume. The exhaust emission from light duty vehicle with bi-fuel system was analyzed by a chassis dynamometer and emission analyzer. From these results, the reduction rate of NOx emission increased in the HCNG fuel and emission amount of THC and CO shows a similar level with CNG fuel. This study can be utilized the basic data for the development of a new business plans related with HCNG engines.