• Title/Summary/Keyword: ${99m}^Tc$

Search Result 1,347, Processing Time 0.03 seconds

Incidental Visualization of Thyroid Gland on Bone Scan Caused by Graves' Hyperthyroidism (뼈 스캔상 우연히 발견된 그레이브스 갑상선기능항진증에서 갑상선의 섭취증가)

  • Sohn, Myung-Hee;Jeong, Hwan-Jeong;Kim, Dong-Wook;Lim, Seok-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.154-155
    • /
    • 2009
  • A 45-year-old man presented with fatigue and weight loss underwent a Tc-99m MDP bone scan because of increased serum alkaline phosphatase. Delayed images at 4 hours demonstrated diffuse increased activity throughout both lobes of the thyroid in the absence of activity of the stomach and salivary glands. Thyroid laboratory indices and a Tc-99m pertechnetate thyroid scan suggested Graves' hyperthyroidism.

$^{99m}Tc-Tin$ Colloid Uptake Ratio of Femoral Head in Healthy Korean (정상 한국인 대퇴골두의 $^{99m}Tc-Tin$ Colloid 섭취율)

  • Zhi, Won-Hee;Sohn, Hyung-Sun;Kim, Choon-Yul;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.215-218
    • /
    • 1989
  • Tc-99m-tin colloid distribution in the hip is studied in 76 patients with no hepatic and hip disorder, because knowledge of normal uptake pattern in the hip is important in evaluation of femoral head vasculature after a fracture. The uptake in femoral head is decreased or disappeared with increasing age due to conversion of red marrow to white marrow.

  • PDF

The Role of Scintimammography in the Diagnosis of Breast Cancer (유방암 진단에서 유방스캔의 역할)

  • Kim, In-Ju
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.213-223
    • /
    • 2001
  • Breast cancer accounts for the higher proportion of cancer related deaths among women, and the incidence of this malignant disease is still increasing. The commonly used screening method is mammography. However, mammography has the drawback of low specificity in differentiating malignant and benign breast diseases. To overcome this low specificity of mammography, scintimammography using various radiopharmaceuticals such as Thallium-201, Tc-99m MIBI, Tc-99m tetrofosmin and Tc-99m MDP was introduced and now actively under the investigation. Several studios have shown that high sensitivity and specificity in detection of primary breast cancer and axillary lymph node metastases using these radiopharmaceuticals. Scintimammography may play important roles in the diagnosis of primary breast cancer, evaluation of the patients with high risk, determining axillary lymph node metastasis, evaluation of the response to chemotherapy, determining the extent of disease, and surveillance of local recurrence. In the future, we should investigate the prognostic role of scintimammography after treatment of breast cancer patients and cost-effectiveness of scintimammography in the detection of primary breast cancer.

  • PDF

Early Diagnosis of Acute Osteomyelitis by TC-99m Pyrophosphate Bone Imaging (Tc-99m Pyrophosphate-골(骨)스캔에 의한 급성골수염(急性骨髓炎)의 조기진단(早期診斷))

  • Kim, Choon-Yul;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.13 no.1_2
    • /
    • pp.55-60
    • /
    • 1979
  • The radiographic diagnosis of osteomyelitis can be suspected early with deep soft tissue swelling, but the actual bone changes of osteomyelitis may be delayed as long as 10 to 14 days after onset or may be totally aborted by antibiotic therapy. Recognition of osteomyelitis by bone imaging is far more rapid than by conventional radiographic examination and can be used on admission to establish the diagnosis. Ten patients suspected of having early, acute osteomyelitis were studied by TC-99m Pyrophosphate bone imaging. Radiographs taken at the same time were all negative. Of these 9 patients showed positive bone images. The bone imaging provides a safe, accurate, noninvasive technique for the early diagnosis of osteomyelitis.

  • PDF

A Case of Hepatoma with Hot Uptake of $^{99m}Tc$-DISIDA to Spleen (원발성 간암환자에서 관찰된 $^{99m}Tc$-DISIDA의 비장 섭취 1예)

  • Lee, Ye-Bong;Kim, Sung-Jin;Park, Eun-Hwi;Bang, In-Sook;Kim, Heung-Joo;Yun, Sung-Chul;Lee, Won-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.140-143
    • /
    • 1993
  • We report a case of hepatoma which had a suggested splenic metastasis in a 64 year-old male patient. Hepatoma proved by abdominal CT (Computed Tomography) and considerable accumulation of $^{99m}Tc$-DISIDA was noted in a enlarged spleen. We suggests the splenic uptake of the radionuclide corresponded to the diffuse metastasis of hepatoma to spleen.

  • PDF

Incidental Detection of a Pseudoaneurysm at an Amputation Stump in a Tc-99m HMPAO labeled Leukocyte Scan (Tc-99m HMPAO 표지 백혈구스캔상 대퇴 절주에서 우연히 발견된 가성동맥류)

  • Sohn, Myung-Hee;Jeong, Hwan-Jeong;Lim, Seok-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.337-338
    • /
    • 2007
  • A 20-year-old man underwent a Tc-99m HMPAO labeled leukocyte scan for the evaluation of an infection at the stump of an AK amputation, which was conducted due to an open communicated fracture of the left lower leg. Blood-flow and blood-pool images demonstrated a pseudoaneurysm with a focus of intense activity medial to the stump, and centered within a large photopenic defect by surrounding hematoma. Delayed image obtained at 3 hours post-injection showed persistent intense and slight increased activity, Contrast angiography confirmed the presence of a pseudoaneurysm arising from a branch of the left superficial femoral artery.

Radiopharmceutical Factors in the Prepartion of $^{99m}Tc-HMPAO$ Images of the Brain (뇌스캔용 $^{99m}Tc-HM-PAO$의 방사성 동위원소표지에 영향을 미치는 인자에 대한 연구)

  • Yeom, Mi-Kyoung;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.117-121
    • /
    • 1991
  • Technetium-99m-hexamethylpropyleneamine oxime $(^{99m}Tc-HM-PAO)$ is a neutral-lipophilic chelate which is used for scanning cerebral blood flow. The labeling efficiencies of $^{99m}Tc-HM-PAO$ is known to be sensitive to the amount of pertechnetate added and the quality of the pertechnetate. Because of these factors, the manufacture recommends that HM-PAO kits be reconstituted with a maximum of 30 mCi pertechnetate which was eluted <4 hr earlier from a generator which had been eluted < 24 hr previously. So we measured the labelling efficiencies and the decomposition rate constant according to the amount of pertechnetate added, the volume of pertechnette added, and generator in-growth time. We used the 3-system chromatographic methods (paper & ITLC-SG chromatography) which analyzed the labelling efficiencies of the $^{99m}Tc-HM-PAO$. There was no significant difference in labelling efficiencies between variable pertechnetate acitvities added. ($39.9{\pm}4.9\;mCi:\;87.8{\pm}5.1\;(%)$, $60.8{\pm}5.0\;mCi:\;90.7{\pm}2.2\;(%)$, $79.0{\pm}6.0\;mCi:\;86.8{\pm}3.9\;(%)$, $106.6{\pm}11.6\;mCi:\;87.7{\pm}1.2\;(%)$, p>0.05) No significant difference in labelling efficiencies were found between pertechnetate of 4ml and 5ml. (4ml : $89.1{\pm}3.2(%)$, 5ml: $87.3{\pm}4.0(%)$, p>0.05). There was no difference between 1-6 and 10-48 hr of generator in-growth time. (1-6 hr: $87.8{\pm}4.0(%)$, 10-48 hr: $89.6{\pm}1.6(%)$, p>0.05) The mean value of decomposition rate constant was $0.196{\pm}0.097\;(hr^{-1})$, and there were no difference according to the amount of pertecnetate added and the volume of pertecnetate added, ($39.9{\pm}4.9\;mCi:\;0.208{\pm}0.059\;(hr^{-1})$, $60.8{\pm}5.0\;mCi:\;0.191{\pm}0.100\;(hr^{-1})$ $79.0{\pm}6.0\;mCi:\;0.192{\pm}0.118\;(hr^{-1})$, $106.6{\pm}11.6\;mCi:\;0.212{\pm}0.030\;(hr^{-1})$, p>0.05, 4 ml: $0.200{\pm}0.074\;(hr^{-1})$, Sml: $0.193{\pm}0.115\;(hr^{-1})$, p>0.05). In the case of using the first eluate, the labelling efficiency of $^{99m}Tc-HM-PAO$ W3S 82.1%. These data suggest that there were no significant alteration in labelling efficiency of $^{99m}Tc-HM-PAO$ according to the considerable range of pertechnetate activities and volume added, and generator in-growth time. Also, it was shown that one vial of HM-PAO kit supplied the $^{99m}Tc-HM-PAO$ which was used for 3-4 patients.

  • PDF

Tc-99m MAG3 SPECT on Transplanted Kidney (이식 신장에서 시행한 Tc-99m MAG3 SPECT)

  • Ryu, Jong-Gul;Kim, Soon;Zeon, Seok-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.519-526
    • /
    • 1999
  • Purpose: This study was designed to evaluate the usefulness of a technetium-99m mercaptoacetyltriglycine (Tc-99m MAG3) single photon emission computed tomography (SPECT) performed on transplanted kidney. Materials and Methods: Thirty renal transplant patients were included in this study. Planar scan was performed for 30 minutes using 555 MBq Tc-99m MAG3. A post-voiding SPECT scan was acquired on the third, seventh, fourteenth and twenty eighth day after transplantation. Results: SPECT scan showed interpretable image quality in 26 of 30 patients (86.7%) and 84 in 120 scans (70%). Fourteen of 26 patients with interpretable SPECT image showed decreased or increased radioactivity, but only 5 had abnormal findings on the planar scan. Focal SPECT defects were seen in allografts with normal function (n=3), acute tubular necrosis (n=3), and acute rejection (n=2). The defects are thought to reflect focally underperfused renal parenchyme or, in normal allografts, an artifact from uneven radioactivity distribution. Four of 10 patients with renal arterial variation showed focally decreased radioactivity and SPECT helped guide funker studies that confirmed the exact cause. Five of 10 patients with acute tubular necrosis or acute rejection showed focally decreased radioactivity, but its relation to the patients' clinical course was not clear. Focally increased radioactivity was observed in 5 allografts with normal function and 1 with double ureter in which local clearance delay was observed. Conclusion: Tc-99m MAG3 SPECT renal scan can detect additional focal abnormalities compared to planar scan. Further study is necessary to elucidate the exact clinical significance of the SPECT findings.

  • PDF

Relationship between the Expression of Sodium Iodide Symporter and the Findings of $^{99m}Tc-MIBI$ Scintimammography in the Primary Breast Cancer (원발성 유방암에서 Sodium Iodide Symporter의 발현과 $^{99m}Tc-MIBI$ 유방스캔의 관계)

  • Seok, Ju-Won;Kim, Seong-Jang;Kwak, Hi-Suk;Lee, Chang-Hun;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.325-332
    • /
    • 2002
  • Purpose: Human Na+/I- symporter (hNIS) is known to be expressed in many tissues other than thyroid gland. The breast cancer cells are one of them and the possibility of radioiodine therapy in treatment of the breast cancer may be suggested. We investigated the expression rate of hNIS and the relationship between the expression of hNIS and the finding of 99mTc-MIBI scintimammographv in the breast cancer Materials and Methods: Surgically proved 56 patients with breast cancer were the subjects of this study The expression of hNIS were evaluated by immunohistochemistry and the results were compared to the findings of 99m7c-MIBI scintimammography. Results: Overall expression rate of hNIS was 41.1% in 56 patients. According to the pathologic diagnosis, it was 42.9% in 49 patients with invasive ductal carcinoma and 28.6% in the 7 patients with ductal carcinoma in situ. The expression rate of hNIS in the 41 cases with a focal increased uptake at he breast lesion on 99m7c-MIBI sointimammogram was 31.7%. That in the 15 cases without any abnormal uptake on the scan was significantly higher(65.7%, p<0.05). Conclusion: The expression rate of hNIS in the patients with breast cancer was not so high. The rate was higher in the patients with no increased uptake at the breast lesion on 99m7c-MIBI scintimammography.

The Effects of Diagnostic Radiology Image on Radiopharmaceutical Testing (방사성의약품 검사 시 진단(CT)영상에 미치는 영향)

  • Lee, Eun-Hye;Lee, Ye-Seul;Kim, Gha-Jung;Choi, Jun-Gu
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.113-117
    • /
    • 2010
  • This research attempts to qualitatively evaluate the intensity change by radiopharmaceuticals and obtain computed tomography using phantom injected with various nuclide. Cylindrical phantom is used for comparing and analysing the effect on diagnosis image during radiopharmaceuticals inspection. Inside of the phantom, water is injected and computed tomography image is scanned. During nuclear medicine invitro, frequently used radiopharmaceuticals, $^{99m}TcO_4$ 20 mCi and $^{18}F$ 14 mCi, is diluted in the water phantom and scanned in the same method. Traverse image obtained by CT scan is divided into six traverse image in the same slice of each scanned image. CT-number(HU) value of 10 measuring point is measured in 2 cm interval based on the center of the phantom. Measured HU value, based on the water phantom, is compared with the image after injecting $^{99m}TcO_4$ and $^{18}F$. Average scale of water is 2.8~1.6 HU, $^{99m}TcO_4$ is 3.0~1.6 HU and $^{18}F$ is 1.2~0 HU. Average of water is $2.3{\pm}0.17$ HU, $^{99m}TcO_4$ is $2.2{\pm}0.85$ HU and F-18 is $0.7{\pm}0.95$ HU. Based on water, reduced value of about 0.1 HU and about 0.5 HU is acquired from $^{99m}TcO_4$ and F-18. Radionuclide used in nuclear medicine inspection utilizes 100~200 KeV energy and obtains image through scintillation camera and PET-CT utilizes 511 KeV positron annihilation energy to obtain image. What we learned from this research is that gamma rays from these energies used in CT scan for diagnosis purpose or radioactive therapy plan can change the intensity of the image. The nuclear medicine inspection for reducing the effect of emitted gamma ray diagnosis image should be obtained after a period of time considering half-life which would be reduced distortion or changed in image.

  • PDF