• Title/Summary/Keyword: $^{152}Eu$

Search Result 48, Processing Time 0.026 seconds

Study on Development of Embedded Source Depth Assessment Method Using Gamma Spectrum Ratio (감마선 스펙트럼 비율을 이용한 매립 선원의 깊이 평가 방법론 개발 연구)

  • Kim, Jun-Ha;Cheong, Jea-Hak;Hong, Sang-Bum;Seo, Bum-Kyung;Lee, Byung Chae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.1
    • /
    • pp.51-62
    • /
    • 2020
  • This study was conducted to develop a method for depth assessment of embedded sources using gamma-spectrum ratio and for the evaluation of field applicability. To this end, Peak to Compton and Peak to valley ratio changes were evaluated according to 137Cs, 60Co, 152Eu point source depth using HPGe detector and MCNP simulation. The effects of measurement distance of PTV and PTC methods were evaluated. Using the results, the source depth assessment equation using the PTC and PTV methods was derived based on the detection distance of 50 cm. In addition, the sensitivity of detection distance changes was assessed when using PTV and PTC methods, and error increased by 3 to 4 cm when detection distance decreased by 20 cm based on 50 cm. However, it was confirmed that if the detection distance was increased to 100 cm, the effects of detection distance were small. And PTV and PTC methods were compared with the two distance measurement method which evaluates the depth of source by the change of net peak counting rate according to the detection distance. As a result of source depth assessment, the PTV and PTC showed a maximum error of 1.87 cm and the two distance measurement method showed maximum error of 2.69 cm. The results of the experiment confirmed that the accuracy of the PTV and PTC methods was higher than two distance measurement. In addition, Sensitivity evaluation by horizontal position error of source has maximum error of less than 25.59 cm for the two distance measurement method. On the other hand, PTV and PTC method showed high accuracy with maximum error of less than 8.04 cm. In addition, the PTC method has lowest standard deviation for the same time measurement, which is expected to enable rapid measurement.

Comparison of the Correction Methods for Gamma Ray Attenuation in the Radioactive Waste Drum Assay (방사성폐기물드럼 핵종분석에서 감마선 감쇠보정 방법들의 비교 평가)

  • Ji Young-Yong;Ryu Young-Gerl;Kwak Kyoung-Kil;Kang Duck-Won;Kim Ki-Hong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.275-284
    • /
    • 2006
  • In the measurement of gamma rays emitted from the nuclide in the radioactive waste drum, to analyze the nuclide concentration accurately, it is necessary to use the proper calibration standards and to correct for the attenuation of the gamma rays. Two drums having a different density were used to analyze the nuclide concentration inside the drum in this study. After carrying out the system calibration, we measured the gamma rays emitted from the standard source inside the model drum with changing the distance between the drum and the detector. The measured values were corrected with the three kinds of gamma attenuation correction methode, as a results, the error was less than 10 % in the low density drum and less than 25 % in the high density drum. The measured activity in the short distance was more accruable than in the long distance. The transmission correction for the mass attenuation showed good results(very Low error) compared to the mean density and the differential peak correction method.

  • PDF

Heavy Metal Contents in Soils and Vegetables in the Plastic Film House (시설재배지(施設栽培地) 토양(土壤) 및 채소류중(菜蔬類中) 중금속함량(重金屬含量) 조사(調査))

  • Jung, Goo-Bok;Jung, Ki-Yeol;Cho, Guk-Hyun;Jung, Beung-Gan;Kim, Kyu-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.2
    • /
    • pp.152-160
    • /
    • 1997
  • In order to monitor the content of heavy metals of soil and vegetable in the plastic film house, five hundred and twenty two soil, and 147 vegetable samples grown under plastic film house were collected for the analysis of heavy metals. The average contents of Cd, Cu, Pb, Zn and As in surface soil were 0.208, 3.69, 2.49, 23.3 and 0.65mg/kg, respectively. Cu and Zn contents of the soil were higher than those values measured for upland soils in 1989, however, these contents were lower than "Countermeasure values" (Cd:4, Cu:125, Pb:300, and As:15mg/kg in soil) for soil contamination indicators described in Soil Environmental Conservation Act of Korea(1996). The contents of Cd, Cu and Zn increased with increasing years of cultivation. The contents of Cd, Cu, and Zn in soils received pig manure compost were higher than those received the poultry or barn yard manure compost. The average contents of Cd, Cu, Pb, Zn and As in fresh vegetable plants ranged from 0.015 to 0.047, 0.341 to 0.802, 0.080 to 0.356, 1.08 to 8.04 and 0.021 to 0.059mg/kg, respectively.

  • PDF

Bacillus oryzicola sp. nov., an Endophytic Bacterium Isolated from the Roots of Rice with Antimicrobial, Plant Growth Promoting, and Systemic Resistance Inducing Activities in Rice

  • Chung, Eu Jin;Hossain, Mohammad Tofajjal;Khan, Ajmal;Kim, Kyung Hyun;Jeon, Che Ok;Chung, Young Ryun
    • The Plant Pathology Journal
    • /
    • v.31 no.2
    • /
    • pp.152-164
    • /
    • 2015
  • Biological control of major rice diseases has been attempted in several rice-growing countries in Asia during the last few decades and its application using antagonistic bacteria has proved to be somewhat successful for controlling various fungal diseases in field trials. Two novel endophytic Bacillus species, designated strains YC7007 and $YC7010^T$, with antimicrobial, plant growth-promoting, and systemic resistance-inducing activities were isolated from the roots of rice in paddy fields at Jinju, Korea, and their multifunctional activities were analyzed. Strain YC7007 inhibited mycelial growth of major rice fungal pathogens strongly in vitro. Bacterial blight and panicle blight caused by Xanthomonas oryzae pv. oryzae (KACC 10208) and Burkholderia glumae (KACC 44022), respectively, were also suppressed effectively by drenching a bacterial suspension ($10^7cfu/ml$) of strain YC7007 on the rhizosphere of rice. Additionally, strain YC7007 promoted the growth of rice seedlings with higher germination rates and more tillers than the untreated control. The taxonomic position of the strains was also investigated. Phylogenetic analyses based on 16S rRNA gene sequences indicated that both strains belong to the genus Bacillus, with high similarity to the closely related strains, Bacillus siamensis KACC $15859^T$ (99.67%), Bacillus methylotrophicus KACC $13105^T$ (99.65%), Bacillus amyloliquefaciens subsp. plantarum KACC $17177^T$ (99.60%), and Bacillus tequilensis KACC $15944^T$ (99.45%). The DNA-DNA relatedness value between strain $YC7010^T$ and the most closely related strain, B. siamensis KACC $15859^T$ was $50.4{\pm}3.5%$, but it was $91.5{\pm}11.0%$ between two strains YC7007 and $YC7010^T$, indicating the same species. The major fatty acids of two strains were anteiso-$C_{15:0}$ and iso $C_{15:0}$. Both strains contained MK-7 as a major respiratory quinone system. The G+C contents of the genomic DNA of two strains were 50.5 mol% and 51.2 mol%, respectively. Based on these polyphasic studies, the two strains YC7007 and $YC7010^T$ represent novel species of the genus Bacillus, for which the name Bacillus oryzicola sp. nov. is proposed. The type strain is $YC7010^T$ (= KACC $18228^T$). Taken together, our findings suggest that novel endophytic Bacillus strains can be used for the biological control of rice diseases.

Monitoring of Micro Noxious Chemicals Caused by Fiber and Chemistry Industrial Wastewater on the Nakdong River Water System (낙동강 수계의 섬유 및 화학 산업폐수로부터 발생하는 미량유해화학물질의 모니터링)

  • Kim Man-Il;Kang Mee-A
    • The Journal of Engineering Geology
    • /
    • v.16 no.2 s.48
    • /
    • pp.145-152
    • /
    • 2006
  • Industry development caused numerical and quantitative increase of noxious chemical substances that contain risk assessment in water resources. For use of efficient water resources a pre-treatment of contaminant source which is flowed in water resources is recognized in essential process. Therefore, the discharged water quality from discharged company began to control contaminant by total amount of pollutant in domestic. However, to estimate closely chemical substances it is not proved up to now, monitoring is very important. This study achieved a monitoring of micro noxious chemical substance by fiber and chemistry industrial wastewater inflow to examine risk assessment of the water system of Nakdong river. Chloroform was measured highest among volatile organic compounds (VOCs) that the results of water quality of influent and effluent are detected from 7 companies of study area. The other side, because measured value of detected chloroform is indefinite detection level in the same company, it is difficulty in management of water quality. However it may not be much effects of the water system of Nakdong river because these company's effluent is high treatment efficiency of chloroform (more than 88%) in sewage treatment plant. On the other hand, in the investigated results for the European Union specified priority substance that is detected to relationship influent and effluent from fiber/chemistry associated industries, these substances were not detected and domestic data was hardly referred. Therefore, data construction of continuous monitoring about this water quality may have to be achieved certainly to utilize as country policy.

The Use of Multilevel Model to Evaluate the Risk Factors for Porcine Reproductive and Respiratory Syndrome in Swine Herds (다층모형을 이용한 국내 양돈농가의 돼지생식기호흡기증후군 위험요인 분석)

  • Kim, Eu-Tteum;Lee, Kyoung-Ki;Kim, Seong-Hee;Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.34 no.2
    • /
    • pp.140-145
    • /
    • 2017
  • The goal of this study was to investigate risk factors associated with porcine reproductive and respiratory syndrome (PRRS) in pig farms in the Republic of Korea using logistic regression and a multilevel model. A cross-sectional study was applied to 305 pig farms with a questionnaire-based interview by veterinarians between March 2014 and February 2015. The questionnaire comprised eight categories: proximity to neighbors, disinfection, visitors, vehicles, insecticides, wild animals, gilts, and feeding. In total, 61 questions in eight categories related to pig farm biosecurity were investigated. Farms were classified as PRRS stable or unstable based on the results of an antibody test and PCR. For univariate analysis, keeping production records with computers (OR = 0.283, 95% CI = 0.056 - 1.425), accredited farm with no use of antibiotics (OR = 0.412, 95% CI = 0.134 - 1.269), reviewing health record of semen prior to purchasing (OR = 0.492, 95% CI = 0.152 - 1.589), complete isolation of runt pigs (OR = 0.264, 95% CI = 0.084 - 0.829), compulsory registering for visitors (OR = 0.424, 95% CI = 0.111 - 1.612), keeping records of insecticide history (OR = 0.406, 95% CI = 0.089 - 1.846), routine on-farm monitoring by veterinarians (OR = 0.314, 95% CI = 0.069 - 1.423), and use of on-farm checklist for biosecurity monitoring (OR = 0.313, 95% CI = 0.063 - 1.553) were found to decrease the probability of PRRS infection. Multivariate and multilevel analysis revealed only two factors, complete isolation of runt pigs (OR = 0.165, 95% CI = 0.045 - 0.602 and OR = 0.208, 95% CI = 0.055 - 0.782) and compulsory registering for visitors (OR = 0.106, 95% CI = 0.017 - 0.655 and OR = 0.119, 95% CI = 0.017 - 0.809) were found to decrease the probability of PRRS infection. The intracluster correlation coefficient of a province for multilevel model was 0.05. The results of this study might facilitate biosecurity measures for individual farms to reduce the probability of PRRS infection.

A Study on the Self-absorption Correction Method of HPGe Gamma Spectrocopy Analysis System Using Check Source (Check Source를 이용한 HPGe감마핵종분석시스템의 자체흡수 보정방법 연구)

  • Jeong-Soo, Park;Hyo-Jin, Lim;Hyun-Soo, Seo;Da-bin, Jang;Myoung-Joon, Kim;Sang-Bok, Lee;Sung-Min, Ahn
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.523-529
    • /
    • 2022
  • Gamma spectroscopy analysis is widely used for radioactivity analysis, and various factors are required for radioactivity calculations. Among the factors, K3 for each sample significantly influences the results. The previous methods of correcting the self-absorption effect include a computational simulation method and a method that requires making a CRM(certified reference material) identical to the sample medium. However, the above methods have limitations when used in small institutions because they require specialized program utilization skills or high manufacturing costs and large facilities. The aim of this study is to develop a method that can be easily and rapidly applied to radioactivity analysis. After filling the beaker with water, we placed the radiation source in a uniform position and used the measured value as the benchmark. Next, a correction factor was derived based on the difference in the radiation source count of the benchmark and the identically measured sample. For the radiation source, Eu-152, which emits a broad range of energy within the measurement range of gamma rays, and Cs-134 and Cs-137, which are indicator nuclides in environmental radiation analysis, were used. The sample was selected within the density range of 0.26-2.11 g/cm3, and the correction factor was derived by calculating the count difference of each sample compared to the reference value of water. This study presents a faster and more convenient method than the existing research methods for determining the self-absorption effect correction, which has become increasingly necessary.

Diameter of Autologous Four Strand Hamstring Tendon for Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술을 위해 채취한 네 가닥 자가 슬괵건의 직경)

  • Choi, Jun-Weon;Han, Sang-Ho;Kim, Eu-Gene;Kim, Jong-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.148-152
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the distribution of the diameter of four strand autologous hamstring tendon and to identify the factors related to the diameter. Materials and Methods: Between December 2004 and July 2006, 66 patients underwent anterior cruciate ligament reconstruction using autologous hamstring tendon. Sixty one patients were male and the other 5 patients were female. Both semitendinosus and gracilis tendon were harvested in every case. Harvested two tendons were folded once together to create a four strand double loop graft and were passed through cylindrical sizer to measure their diameter. Parameters such as sex, age, height and weight were analyzed for their correlation with the diameter of the graft. Results: The diameter of the graft ranged from 6 mm to 10 mm. The graft with the diameter of 8 mm was most common and the average diameter of all the grafts was $7.85{\pm}0.92mm$. Seven patients (10.6%) had a graft with the diameter of 6 mm, which is considered too thin to be ideal one. No statistically significant correlation was found between age of the patient and the diameter of the graft. However, the diameter of the graft was significantly correlated with sex, height and weight of the patient. Female patients had a significant tendency to have thinner hamstring tendons. Both small height and light weight of the patients were correlated with thinner hamstring tendons significantly. Conclusion: Sex, height and weight of the patients were the factors that had a statistically significant correlation with the diameter of the graft. Being aware of the risk factors related with harvesting exceedingly thin hamstring tendon prior to anterior cruciate ligament reconstruction, one can utilize wide range of options in selecting an optimal graft.

  • PDF