DOI QR코드

DOI QR Code

Automatic Sterilization Reading Device Using Biological Indicator Study of Fluorescence Emission Charateristics According to Incident UV Light Amount

생물학적 표시기를 이용한 멸균 자동 판독장치의 UV 광량에 따른 형광 방출 특성 연구

  • Hyeok Song ;
  • Woo-Cheol Lee (Dept. Biomedical, Eng, Eulji University)
  • 송혁 (을지대학교 대학원 생체의과학융합학과) ;
  • 이우철 (을지대학교 대학원 생체의과학융합학과)
  • Received : 2024.08.22
  • Accepted : 2024.10.12
  • Published : 2024.10.31

Abstract

In the study of the fluorescence detection characteristics of the UV light intensity control function for automatic reading sterilization devices, the fluorescent medium of the biological indicator meets the spore bacteria, causing a fluorescence reaction. We try to find certain characteristics by measuring the characteristics of the detected amount of fluorescence while adjusting the intensity. Research to find the appropriate intensity of UV light for automatic reading sterilization devices aims to increase the accuracy of biological indicators and increase the accuracy of reading through appropriate UV light intensity over time.

멸균 자동 판독장치를 위한 UV 광량 세기 조절 기능의 형광 방출 특성 연구는 생물학적 표시기의 형광 배지와 아포균이 만나서, 형광 반응을 일으키게 되는데, 신속하게 판독하기 위해 형광 배지와 아포균에 섞여있는 곳에 UV 광량 세기를 조절해 주면서 형광 방출되는 양의 특성을 측정하면서 일정한 특성을 찾아낸다. 기존에는 UV의 광량을 고려하지 않고 형광 방출 특성을 연구했다면, 멸균 자동 판독장치를 위한 적절한 UV 광량의 세기를 찾아내는 연구는 생물학적 표시기의 감도 특성을 높여주고, 시간이 지나서도 적절한 UV 광량 세기를 통해서 판독의 정확성을 높인다.

Keywords

References

  1. S. Lee, M. Shim, S. Kim and G. Kim, Principles and Practice of Sterilization, Hyunmunsa: 2004, pp.186~196.
  2. Y. Kim, G. Lee, and Y. Kim, "Miniature Fluorescence Detection System for Protein Chip," The Korean Institute of Electrical Engineers, 2002, pp.254~256. doi.org/10.1117/12.583281
  3. K. Cho, J. Seo and S. Choi, "Design of a customizable fluorescence detection system for fluorescently labeled tumor cells," Biomedical Engineering Frontiers, vol. 23, no. 3, 2019, pp261~266 doi/10.34133/bmef.0005
  4. C. Lee, "Trends and Development Directions of Fluorescence Detection Technology", Korea Institute of Science and Technology Information Technical report. 2021. doi: 10.3389/fonc.2024.1383798
  5. J. Michelle, O. Nancy, Infection Control & Hospital Epideniology, Cambridge University Press: 02 January 2015.
  6. S. Chae, E. Kim and H. Jang, "Safety Assessment of an Intrinsic Fluorescence Method for Monitoring Lactic Acid Bacteria," The Korean Journal of Community Living Science, vol. 30, no. 3, 2019, pp327-339. doi: 10.1016/j.ajic.2013.09.015
  7. C. Choi, Color Management Lecture, Mijinsa: 2021, pp.87-89.
  8. C. Phillip, "Evaluation of a new rapid readout biological Indicator for use in 132℃ and 135℃ vacuum-assisted steam sterilization cycles," American Journal of Infection Control, vol. 42, no. 2, 2014, pp17-21. doi: 10.1016/j.ajic.2013.09.015
  9. D. Jameson, Introduction to fluorescence, Taylor & Francis: 2014, pp191~213.
  10. B. Fraser, C. Murphy and F. Bunting, Color Management, Vase: 2009, pp.25-62.