Ultimate Behavior of GFRP Shell Structure Stiffened by Steel Pipe Ring

강관링으로 보강된 GFRP 쉘구조의 극한 거동

  • Kim, In Gyu (School of Civil Engineering, Chungbuk National University) ;
  • Lim, Seung Hyun (School of Civil Engineering, Chungbuk National University) ;
  • Kim, Sung Bo (School of Civil Engineering, Chungbuk National University)
  • 김인규 (충북대학교 토목공학부) ;
  • 임승현 (충북대학교 토목공학부) ;
  • 김성보 (충북대학교 토목공학부)
  • Received : 2014.05.12
  • Accepted : 2014.05.28
  • Published : 2014.06.27

Abstract

The experiment and FE analysis of ultimate behavior of GFRP cylindrical shell structure stiffened by steel pipe ring instead of rectangular cross-section ring was presented. Four kinds of test models were designed and flexural failure experiment was performed to investigate ultimate behavior characteristic according to the size of cross section of steel pipe ring and diameter of GFRP shell. Material properties of specimens were experimented by bending, tensile and compressive test. Displacements and strains were measured to evaluate failure behavior of steel pipe ring and GFRP shell structure. The experimental results were compared with the FEA results by commercial program ABAQUS. It is observed that GFRP shell structure stiffened by steel ring have enough ductility to bending failure, and an increase of bending rigidity of steel ring is very effective to increase of failure strength of GFRP shell structure.

원형 강관으로 보강된 GFRP 재질의 원통형 쉘구조에 대한 극한 휨 실험 및 범용 유한요소해석 프로그램인 ABAQUS를 사용한 전산해석을 수행하였다. 개인하수처리 시설의 설계 기준에서 제시된 직사각형 단면형상의 GFRP 재질의 보강링이 적용된 설계기준을 바탕으로 원형 강관 보강링에 대한 단면 재료 특성이 반영된 식을 검토하여 설계하였다. 보강링의 단면, GFRP 본체의 직경과 두께에 의한 극한 거동 특성을 분석하기 위하여 총 4개의 시험체를 설계 제작하여 집중하중 정적재하 시험을 수행하였다. 실험결과 강관 보강링이 사용된 GFRP 쉘구조는 휨파괴가 발생할 때까지 충분한 연성도를 가지고 있으며, 강관 보강링의 휨강성 증가에 따른 전체 구조물의 강도증진이 효과적임을 확인하였다.

Keywords

References

  1. 장효주, 이장훈, 강선홍(2010) 개인하수처리시설의 제도 개선에 관한 연구, 상하수도학회지, 대한상하수도학회, 제24권, 제1호, pp.33-40. Jang, H.J., Lee, J.H., and Kang, S.H. (2010) Research Papers : The System Improvement of the Individual Sewage Treatment System, Journal of Korean Society of Water and Wastewater, KSWW, Vol.24 No.1, pp.33-40 (in Koean).
  2. 환경부(2013) 개인하수처리시설 제조제품의 구조.재질 및 성능 기준 제55조. Ministry of Environment (2013) Standard of Structural and Material Performance of Underground Septic Tank, Code of sewerage 55 (in Korean).
  3. 김홍택, 권혁준, 윤명준, 윤순종, 한연진(2010) 수치해석을 통한 지중매설된 GFRP관의 적용성 평가, 한국지반환경공학회논문집, 한국지반환경공학회, 제11권, 제8호, pp.73-82. Kim, H.T., Kwon, H.J., Yoon, M.J., Yoon, S.J., and Han, Y.J. (2010) Verification of Applicability of Buried GFRP Pipe Through Numerical Analysis, Journal of Korean Geo-Environmental Society, KGES, Vol.11, No.8, pp.73-82 (in Korean).
  4. 한택희, 서주형, 염응준, 강영종(2006) 리브로 보강되니 GFRP 관로의 탄성 좌굴거동 특성, 한국강구조학회논문집, 한국강구조학회, 제18권, 제6호, pp.737-745 Han, T.H., Seo, J.H., Youm, E.J., and Kang, Y.J. (2006) Elastic Behavior Characteristics of GFRP Pipe Reinforced Ribs, Journal of Korean Society of Steel Construction, KSSC, Vol.18, No.6, pp.737-745 (in Korean).
  5. 김성보, 조광제(2013) 원통형 GFRP 개인하수 처리시설의 극한 거동에 대한 매개변수해석, 대한토목학회논문집A, 대한토목학회, 제33권, 제4호, pp.1337-1347. Kim, S.B. and Cho, K.J. (2013) Parametric Analysis on Ultimate Behavior of Cylindrical GFRP Septic Tank, Journal of Korean Society of Civil Engineers, KSCE, Vol.33, No.4, pp.1337-1347 (in Korean). https://doi.org/10.12652/Ksce.2013.33.4.1337
  6. 류재호, 박세호, 주영규, 김상대(2011) GFRP를 이용한 경량합성바닥의 휨성능에 대한 실험적 평가, 한국강구조학회논문집, 한국강구조학회, 제23권, 제1호, pp.125-135 Ryu, J.H., Park, S.H., Ju, Y.K., and Kim, S.D. (2011) An Experimental Evaluation on Flexural Performance of Light-Weight Void Composite Floor using GFRP, Journal of Korean Society of Steel Construction, KSSC, Vol.23, No.1, pp.125-135 (in Korean).
  7. 지효선(2012) GFRP 슬래브 교량의 장기성능 평가, 한국강구조학회논문집, 한국강구조학회, 제24권, 제3호, pp.349-360. Ji, H.S. (2013) Long-Term Performance Evaluation of a GFRP Slab Bridge, Journal of Korean Society of Steel Construction, KSSC, Vol.24, No.3, pp.349-360 (in Korean). https://doi.org/10.7781/kjoss.2012.24.3.349
  8. 손병직, 지효선(2013) GFRP 복합소재 바닥판의 간편해석법, 한국강구조학회 논문집, 한국강구조학회, 제25권, 제4호, pp.359-368 Son, B.J. and Ji, H.S. (2013) A Simplified Analysis Method of GFRP Composites Deck, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.4, pp.359-368 (in Korean). https://doi.org/10.7781/kjoss.2013.25.4.359
  9. Kabir, M.Z. and Sief, A.E. (2010) Lateral-Torsional Buckling of Retrofitted Steel I-Beams Using FRP Sheets, Sharif University of Technology, Sharif University, Vol.17, No.4, pp.262-272.
  10. Damatty, A.A., El, Abushagur, M., and Youssef, M.A. (2003) Experimental and Analytical Investigation of Steel Beams Rehabilitated Using GFRP Sheets, Steel & Composite Structures: an international journal, TECHNOPRESS, Vol.3, No.6, pp.421-438. https://doi.org/10.12989/scs.2003.3.6.421
  11. ABAQUS (2010) ABAQUS/CAE User's Manual Version 6.10, H. K&S Inc.
  12. Ramberg, W. and Osgood, W.R. (1943) Description of Stress-Strain Curves by Three Parameters. Technical note No.908, National Advisory Committee For Aeronautics, Washington DC.

Cited by