• Title/Summary/Keyword: xenon radiation

Search Result 26, Processing Time 0.024 seconds

Optical Characterization of a High-Flux Solar Thermal Simulator (고집광 태양열 시뮬레이터의 광학 특성 평가)

  • Chai, Kwan-Kyo;Lee, Hyun-Jin;Yoon, Hwan-Ki;Kim, Jong-Kyu;Kang, Yong-Heack;Lee, Sung-Wook
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.65-71
    • /
    • 2015
  • A solar thermal simulator is suitable for indoor experiments of solar receivers and reactors when solar insolation and weather conditions are not favorable. Moreover, due to the easy control of electric power input, the solar thermal simulator allows the adjustment of power input incident on solar receivers and reactors and thus the implementation of accurate experiments. We manufactured a solar simulator, which is comprised of three sets of a xenon lamp and an elliptical reflector. In order to serve as a test facility, optical characterization of the solar simulator via radiation heat flux measurement is a critical prerequisite. We applied the flux mapping method to measuring the heat flux distribution of the three lamps. We presented the measurement results in terms of the heat flux distribution, the peak heat flux, the power distribution, the maximum power, and the efficiency for electric power conversion into radiation power. Characterization results show that our solar simulator provides the peak heat flux of $3,019kW/m^2$, the maximum power of 16.9 kW, and the conversion efficiency of 45%, additionally with a 10% operation margin for output increase.

Biphasic Mechanical Responses of Rat Thoracic Aorta to Irradiation with $250{\sim}500\;nm$ Light (돼지 관상동맥 및 흰쥐 흉부대동맥에서 자외선 및 가시광선 조사시 파장에 따른 기계적 반응과 Cyclic GMP의 농도변화)

  • Kook, Hyun
    • The Korean Journal of Pharmacology
    • /
    • v.31 no.3
    • /
    • pp.285-290
    • /
    • 1995
  • This study was undertaken to define the varying responses of vascular smooth muscle to different wavelengths of ultraviolet radiation and to relate them to the changes in cyclic GMP contents. The ring preparations of rat thoracic aorta with intact or removed endothelium were irradiated with the ultraviolet or visible light (UVR) of wavelengths in step of 10 nm between 250 and 500 nm from xenon lamp of a spectrofluorometer, and the changes in vascular tension were recorded. For cyclic GMP assay, the preparations, pretreated with phenylephrine as in the tension experinents, were frozen after irradiation and homogenated in trichloroacetic acid. The supernatant was extracted with ether and the cyclic GMP contents were measured with radioimmunoassay. In the endothelium-intact preparations, biphasic responses, vasoconstriction (UVR-contraction) followed by vasodilatation (UVR-dilatation), were observed. The maximal UVR-contraction was observed at 320 nm, while the maximal vasodilatation was elicited at 420 nm. In the endothelium-removed rings, however, only vasodilatation was observed, with the maximal vasodilatation taking place at 370 nm. The cyclic GMP contents were not affected by the Irradiation with 320 nm for 30 sec or 1 min in the endothelium-intact preparations, while it was significantly increased by 380 and 420 nm. In the endothelium-removed preparations, UVR of 370 nm markedly increased the cyclic GMP contents. The present study indicates that the increase in cyclic GMP is closely related to vasodilatation induced by UVR of 420 nm in the endothelium-intact or 370 nm in the denuded preparations, whereas it is not involved in the vasoconstriction induced by UVR of 320 nm in the intact rings, and the mechanism leading to UVR-contraction remains to be clarified. These observations suggest that nitric oxide-cyclic GMP system is closely related to the UVR-dilatation in rat aortic preparation, while it is not involved in the UVR contraction.

  • PDF

Comparison of Lung Ventilation Scan Using Technegas and $^{99m}Tc-DTPA$ Aerosol (Technegas 환기스캔과 $^{99m}Tc-DTPA$ Aerosol 스캔의 비교)

  • Choi, Yoon-Ho;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Keun-Youl;Koh, Chang-Soon;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.237-243
    • /
    • 1990
  • Pulmonary embolism demands rapid and accurate diagnosis. And ventilation imaging has greatly improved the diagnostic accuracy of pulmonary embolism in addition to perfusion imaging. Agents currently used include xenon-133, krypton-81m and technetium-99m radioaerosols. However radioactive gases are compromised by availability and cost for krypton-81m, radiation dose, gamma energy and non?physiologic behaviour for xenon-133. Radioaerosols of technetium-99m componds are rapidly cleared from the lung after inhalation, and their relative low effeciency (specific radioactivity) and wide distribution of particle sizes make them also suboptimum. A new ventilation agent, Technegas is a suspension of structured graphite ellipsoids with diameter below 20nm, labelled with $^{99m}Tc$ in a carrier gas of Argon. This report describes the authors' clinical experience with Technegas. This is the first reported clinical study of this agent in Korea. A comparison of Technegas and $^{99m}Tc-DTPA$ aerosol was performed in 12 patients with various pulmonary diseases such as COPD, pulmonary tuberculosis and pleural effusion. All patients were studied with $^{99m}Tc-DTPA$ aerosol inhalation and Technegas ventilation. In both studies image quality was assessed (1) semiquantitatively by scoring bronchial and gastric activity, (2) subjectively by direct visual comparison of peripheral lung images and (3) quantitatively by computing the peripheral penetration index(PI) for each lungs. The bronchial activites were seen in 7 out of 12 cases with $^{99m}Tc-DTPA$ aerosol and in 5/12 with Technegas. The gastric activities were seen in 5/12 and 1/12 cases respectively. The average values of PI were 61.26% with $^{99m}Tc-DTPA$ aerosol and 69.20% with Technegas (p>0.05). Using $^{99m}Tc-DTPA$ aerosol, COPD patients showed deposition in the central airways with poor visualization of the peripheral areas of the lungs. In Technegas studies these phenomena were less prominent, and the examination is well tolerated by pateients and requires only a minimum of patient cooperation. With superiority of easy availability and handling, better physical characteristics and favorable Image quality, Technegas is a Promising agent for lung ventilation scanning.

  • PDF

Fabrication of Ionization Chamber to Measure the Burnup of Spent Fuel (사용후핵연료 연소도 측정을 위한 이온 챔버 제작)

  • Park, Se-Hwan;Eom, Sung-Ho;Shin, Hee-Sung;Lim, Hye-In;Ha, Jang-Ho;Kim, Han-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.21-25
    • /
    • 2010
  • Burnup of spent fuel should be determined accurately for the safety control of spent fuel. Especially, it is necessary to measure the burnup profile along the nuclear fuel axis. In the present work, an ionization chamber was designed and fabricated to measure the gamma ray profile inside the guide tube of spent fuel. The ionization chamber was composed of three parts; induction part, gas-inlet part, and sensor part. The sensor part had two electrodes; cathode and anode. A guide electrode was considered in the ionization chamber design to make the ionization chamber to be inserted easily into the guide tube. Pure gas (argon and xenon) was inserted into the ionization chamber, and the leakage current and saturation curve were measured to determine the operation characteristics of the ionization chamber. The gamma ray radiation was also measured in relatively high dose environment. The gamma ray profile of the spent fuel will be measured with the ionization chamber.

A Study on the UV-cut Properties of Cotton Fabrics Treated with UV-absorber (자외선 흡수제 처리 면직물의 소비성능 개선(제1보) - 자외선 차단성능에 관한 연구 -)

  • 강미정;권영아
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.5
    • /
    • pp.925-932
    • /
    • 2001
  • The influence of ultraviolet(UV)-ray in sun light on human skin has been noted. Textiles can provide protection against harmful UV-radiation. Normally UV-absorbing finishes are used to get better protection. The purpose of this study is to evaluate the UV-cut properties of cotton fabrics treated with UV-absorber. 2,2-dihydroxy-4,4-dimethoxbenzophenone, as UV-absorber was applied to 100% cotton fabric. Reagents added in finishing solution were Triton X-100, polyethylene glycol 400, and $MgCl_2{\cdot}6H_2O$, and C.I. Direct Red 81. Both untreated and treated cotton fabrics were exposed to a xenon arc lamp for 20 and 80 hours. UV absorption spectra of finishing solutions and UV transmission spectra of fabrics were measured by the UV/VIS spectrophotometer. The results of this study can be summarized as follows. The results of this study can be summarized as follows. Absorption and the related transmission spectra were modified in a controlled way with UV-absorber. Absorption effect of UV-absorber was improved by adding Triton X-100, PEG 400, and $MgCl_2{\cdot}6H_2O$ in finishing solution. The UV absorption of finishing solution was in the following order: U/D/T/P/M>D/T/P/M> D/T> D/P, D>U/T/P/M>U/T>T/P/M>T. The UV transmittance of cotton fabrics was remarkably decreased by the application of UV-absorber and additives. The UV-cut properties were most improved by the application of U/D/T/P/M.

  • PDF

Resistance to Weathering with Materials for Fisheries Facilities 2. Photodegradation of Plastic Materials for Floatation Unit (수산 시설용 재료의 내후성에 관한 연구 2. 부력재용 플라스틱 재료의 내후성)

  • 김태호
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.140-146
    • /
    • 2001
  • In order to analyze the photodegradation of plastic materials for floats or frames of fisheries facilities, weathering experiment on 3 kinds of plastic materials like high density PE of Korea(KHDPE) and Norway(NHDPE) and high strength PVC(Hi-PVC) was carried out during 900 hours exposure by using xenon light source of weather-Ometer. The results obtained are as follows; With increasing of ultraviolet radiation(UVR) time, a remarkable losses in the mechanical properties of each specimen were observed except for the remaining strain of HDPE materials. As NHDPE lost almost 15% of its initial tensile stress during a 900 hours exposure followed by KHDPE 12% and Hi-PVC 6%. In addition, the remaining tensile stress RS(kg/$mm^2$) decreases almost linearly with the lapse of exposure time to light Y(Year) and the empirical equations of each specimen computed as follows; KHDPE : RS=2.6769-0.0003Y($r^2$=0.63) Hi-PVC : RS=5.3470-0.0003Y($r^2$=0.91) NHDPE : RS=2.4929-0.0004Y($r^2$=0.97) It was observed by scanning electron microscope that all specimens with UVR time had started to decompose and had bubbled areas and small holes.

  • PDF