• Title/Summary/Keyword: x-y table

Search Result 325, Processing Time 0.025 seconds

A Convergence Study on the Contamination and Disinfection of General X-ray generator Practical Equipment (일반촬영 실습 장비의 오염 및 소독에 관한 융합적 연구)

  • Park, Gyu-Tae;Kim, Dong-Heun;Park, Sang-Hee;Jung, Won-Hee;Kim, So-Yeon;Hong, Hee-Jin;Son, Na-Ra;Nam, Seoul-Hee;Han, Man-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 2020
  • It is going to select one X-ray generating device for diagnosis in a radiography laboratory at K university in Gangwon-do to detect bacteria on the surface contamination of tables, IP cassettes, and lead gowns for medical radiation shielding and to inform students of the need for proper disinfection control and hand hygiene. Then disinfection was carried out with tissue, tissue cleaner and 70% alchol and immediately collected with sterile cotton swabs to assess the contamination distribution status and disinfection effects of the surface. The results of measuring the degree of contamination on the surface showed that the largest number of bacteria were detected in Apron, and the evaluation of the disinfection effects according to surface contamination showed a noticeable effect at 70% Alcohol in IP Cassette, and the disinfection effect was the same for Apron. Therefore, in order to prevent bacterial infections among students, basic hand washing and regular disinfection should be performed before the practice to prevent infection.

Comparative Analysis of Absorption Doses between Exposed and Unexposed Area on Major Organs During CT Scan (전산화 단층촬영시 주선속내 외의 주요장기 흡수선량 비교분석)

  • 사정호;서태석;최보영;정규회
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.59-71
    • /
    • 2000
  • It is possible to obtain a fast CT scan during breath holding with spiral technique. But the risk of radiation is increased due to detailed and repeated scans. However, the limitation of X-ray doses is not fully specified on CT, yet. Therefore, the purpose of the present study is to define the limitation of X-ray doses on CT The CT unit was somatom plus 4. Alderson Rando phantom, Solenoid water phantom, TLD, and reader were used. For determining adequate position and size of organs, the measurement of distance(${\pm}$2mm) from the midline of vertebral body was performed in 40 women(20~40 years). On the brain scan for 8:8(8mm slice thickness, 8mm/sec movement velocity of the table) and 10:10(10mm slice thickness, 10mm/sec movement velocity of the table) methods, the absorption doses of exposed area of the 10:10 were slightly higher than those of 8:8. The doses of unexposed uterus were negligible on the brain scan for both 8:8 and 10:10. On the chest scan for 8:8, 8:10(8mm slice thickness, 10mm/sec movement velocity of the table), 10:10, 10:12(10mm slice thickness, 12mm/sec movement velocity of the table) and 10:15(10mm slice thickness, 15mm/sec movement velocity of the table) methods, 8:8 method of the absorption doses of exposure area was the most highest and 10:15 method was the most lowest. The absorption doses of 8:10 method was relatively lower than those of the other methods. In conclusion, the 8:10 method is the most suitable to give a low radiation burden to patient without distorting image quality.

  • PDF

Experimental Study for Phase-contrast X-ray Imaging Based on a Single Antiscatter Grid and a Polychromatic X-ray Source (단일 비산란 그리드 및 다색광 x-선원 기반 위상대조 x-선 영상화 실험 연구)

  • Park, Yeonok;Cho, Hyosung;Lim, Hyunwoo;Je, Uikyu;Park, Chulkyu;Cho, Heemoon;Kim, Kyuseok;Kim, Guna;Park, Soyoung
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.215-222
    • /
    • 2015
  • In this work, we performed a proof-of-concept experiment for phase-contrast x-ray imaging (PCXI) based on a single antiscatter grid and a polychromatic x-ray source. We established a table-top setup which consists of a focused-linear grid having a strip density of 200 lines/inch, a microfocus x-ray tube having a focal-spot size of about $5{\mu}m$, and a CMOS-type flat-panel detector having a pixel size of $48{\mu}m$. By using our prototype PCXI system and the Fourier demodulation technique, we successfully obtained attenuation, scattering, and differential phase-contrast images of improved visibility from the raw images of several selected samples at x-ray tube conditions of $90kV_p$ and 0.1 mAs. Further, fusion image (e.g., the attenuation+the scattering) may have an advantage in displaying details of the sample's structures that are not clearly visible in the conventional attenuation image. Our experimental results indicate that single-grid-based approach seems a useful method for PCXI with great simplicity and minimal requirements on the setup alignment.

Quality Control of Upper Gastrointestinal Series(UGIS) by The Image Quality Evaluation Table of Korea and Japan (한.일 화질평가표에 의한 우리나라 위장조영검사의 품질관리)

  • Oh, Hye-Kyong;Kim, Jung-Min;Kim, Chang-Gyun;Park, Young-Seon;Seon, Jong-Ryul;Choi, In-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.277-285
    • /
    • 2011
  • To determine the quality control of UGIS, we acquired 105 patients sampling image at 21 general screening centers. The results of image quality evaluation table containing two countries's UGIS showed that the mean of image qualified education table of our country was 73.3 and the standard error was 4.49; In addition, 19 organizations of 21 general screening centers were given appropriate judgement. The average of image qualified education table of Japan was 58 and the standard error was 4.45. Only 8 organizations were given appropriate judgement. Although we made the image quality evaluation tables with same images, there were many differences in the result of two tables. We figured out the problem about the description of whole stomach and photograph skills. Furthermore, we analysed the situation of the UGIS at each general screening center with the acquired images. The biggest problem of the UGIS of our country was that the procedures were performed without clear medical methods. Methods of UGIS were different at every 21 general screening centers, and most of them did not take exam of anterior surface of stomach of the UGIS. In addition, some general screening centers did not include mucosal relief method or esophagography which is required to include in the image qualified education table of our country. Because polisography is used in the same body position, the problem occured about indiscreet exposure dose of patients. Therefore we have to make an effort to get X-ray images which have enough diagnosis information by the quality control of UGIS.

Electrochemical Measurement of Salt Content in Soysauce and Margarine (간장 및 마가린중의 식염함량의 전기화학적 측정법)

  • Lee, Jong-Hyeok;Lee, Byeong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.105-108
    • /
    • 1993
  • A new devised conductivity meter was used in the rapid and convenient determination of salt contents of soysauce and margarine. The equation $(1){\sim}(5)$ was set up between the electric conductivity (x) for 100 times diluted solution of soysauce and the salt contents (y). y=0.083x-1.253 $(at\;15^{\circ}C)$ (1) y=0.077x-2.062 $(at\;20^{\circ}C)$ (2) y=0.071x-2.686 $(at\;25^{\circ}C)$ (3) y=0.066x-3.153 $(at\;30^{\circ}C)$ (4) y=0.062x-3.522 $(at\;35^{\circ}C)$ (5) y=(-0.001139t+0.0999)x+(-0.126t+0.557) $(temperature\;range;\;15{\sim}35^{\circ}C)$ (6) y=salt contents [%], x=conductivity $[{\mu}{\Omega}^{-1}{\cdot}cm^{-1}]$, $t=temp.\;[^{\circ}C]$. The salt contents could be estimated by the equation $(1){\sim}(6)$ and the measured conductivity. The estimated salt contents agreed with that determined by conventional method within 0.27[%] as salt contents. For margarine, the equation (7) was setup between the conductivity (x) and the salt contents (y) y=0.00266x+0.057 $(at\;20^{\circ}C)$ (7) y=salt contents [%], x=conductivity $[{\mu}{\Omega}^{-1}{\cdot}cm^{-1}]$ The salt contents estimated with the equation (7) and the measured condutivity agreed with that determined by conventional method within 0.028[%] as salt contents. The electric conductivity obtained with conductivity meter could be a valuable criteria salt contents test of Korean soysauce and margarine determining in a few second or minute by handy compact portable meter.

  • PDF

A Review of Relationship Between Level of Fertility and Contraceptive Prevalence in Korea: Some Implication for Policy Suggestion (최근의 피임실천수준과 출산력추이에 관한 고찰 -몇가지 정책적 제언을 중심으로-)

  • 고갑석
    • Korea journal of population studies
    • /
    • v.8 no.2
    • /
    • pp.79-92
    • /
    • 1985
  • Fertility has been declined since 1966 (see Table 1). This fertility reduction was duely caused by age at first marriage, induced abortion and contraceptive practice which has been largely increased in recent years. Although tbe proximate determinant such as induced abortion, age at marriage and breastfeeding can and do have an effect on fertility, the principal cause of the reduction in fertility in Korea during the fertility transition can be supported by correlation between level of fertility and contraceptive prevalence (See Fig. 4). Taking a regression equation between fertility (TER. Y) and prevalence level (X), the total fertility rate in 1984 was estimated as 1.9 and 2.1 based on lenear and expotential function shown as follow; $Y_1$=5.709-0.0549 X and $Y_2$_______80________ 1+e2.433+0.017X ($R^2$=O. 93) ($R^2$=0. 96) Where $Y_1$ and $Y_2$ denote total fertility rates obtained through two equations respectivelly. The peak of contraceptive prevalence was assumdd as 80 percent which is almost upper limit in human society. On the other hand, an observed value of 1984 fertility level obtained from five month period shows 2.1 which is coincident with logistic fitting after the adjustment of response error assumed around 10 to 20 percent, At any rate, fertility of Korean women will have been reached replacement level (2.1) by 1985.Thus policy for family planning program must be reviewed toward the direction of integrated approach particularly with MCH program inasmuch as fertility in Korea has already shown population replacement level that require more good quality of service in family planning and their There must be an advanced level of fertility in Korea because wide use of contraception and induced life abortion and age at marriage will effect modern fertility which shows up and down trend between 2.1 and 1.5 in general.

  • PDF

A Study on software Development for Control Application of Microprocessors (마이크로프로세써의 제어 응용을 위한 소프트웨어 개발에 관한 연구)

  • 이태원
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.6
    • /
    • pp.66-78
    • /
    • 1978
  • An assembly package program is developed for a computerize4 operation of a drilling machine system utilizing a microprocessor. Different drilling instruction requires merely the input of different sets of input data. To make pulse motors to follow their input pulse trains with fidelity, an optimum start-stop rate matrix is proposed, whose elements are determined according to the pulse motor torque and the load inertia of the mechanical system composed of a workpiece and a worktable.

  • PDF

High Speed and Accuracy Control of Timing Belt System for SFFS of Office (오피스용 3 차원 실물 복제기를 위한 타이밍 벨트 시스템의 고속.고 정밀 제어)

  • 이현정;김정수;이민철;김동수;이원희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.339-342
    • /
    • 2004
  • The x-y table of the SFFS to move a printer head must be the system that has a high speed and accuracy. So we propose the SMCSPO algorithm on the timing belt system. The major contribution is the design of a robust observer for the state and the perturbation of the timing belt system, which is combined with a robust controller. The control performance of the proposed algorithm is compared with PD control by the experiments. The results of SMCSPO algorithm showed more accuracy and better performance than PD control. Therefore we may apply the algorithms to a high speed and accuracy control for SFFS.

  • PDF

Performance of Built-in Capacitance Type Transducer of a Magnetic Bearing System (캐패시턴스형 센서가 내장된 자기베어링 시스템의 작동성능에 관한 연구)

  • 장인배;한동철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2082-2088
    • /
    • 1995
  • In this paper, we designed and fabricated the magnetic bearings and built-in type cylindrical capacitive transducers for improving the vibration characteristics of rotating shaft. The eddy current and magnetic field from the electromagnet of the bearing don't affect the measuring signal of the capacitive type transducers so that it is possible to locate the capacitive sensor plates around the magnetic bearing poles and can improve the spillover problem which is induced by the noncollocation of the sensors and actuators. According to the sensitivity calibration schemes using a X-Y table, the cylindrical capacitive transducers have a good linearities in the .+-.70.mu.m range from the geometric center of the sensor plates. The measured results also show high displacement sensitivities of the sensors. According to the performance test of the magnetic bearing which is controlled by the analog PD controllers, we found that the built-in capacitive transducer system successfully measures the journal displacement in the magnetic field and therefore the magnetic bearing system supports the rotating shaft up to 12,000 rpm.

A study on robustness of automatic seam tracking system (용접선 자동추적장치의 강인성에 관한 연구)

  • 강희신;조택동;양상민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.775-778
    • /
    • 1996
  • In this research, the robustness of a seam tracking for the automatic welding system is studied. The laser displacement sensor is used as a seam finder. X-Y moving table drived by ac servo motor controls the position and velocity of the torch-and-sensor part. However, dc servo motor is used to control the position and velocity of the torch. The sensor locates ahead of torch to preview the weld line, and brings about the inaccuracy on the torch tracking. To enhance the robustness on this system against the influence of disturbances and model uncertainty, H$\_$.inf./ control is applied to the angular motion of torch. The simulation shows that the tracking accuracy improved significantly. Also, experimental results give a good performance of H$\_$.inf./ control strategy to the automatic seam tracking system for the welding.

  • PDF