• 제목/요약/키워드: x-ray fluorescence

Search Result 417, Processing Time 0.033 seconds

Manjang Cave of Twinrock Composition obtained by Fundamen Parameter Method in X-Ray Fluorescence Spectrometry (Fundamental Parameter 법에 의한 만장굴 용암 석주의 형광X선분석)

  • SAWA, ISAO
    • Journal of the Speleological Society of Korea
    • /
    • v.21 no.22
    • /
    • pp.17-56
    • /
    • 1990
  • Cheju Island, which was formed by volcanic activity, is an oval in its shape with the major axis of 80km and the minor axis of 40km. The island holds in its heart Mt. Hanla rising 1,950m above the sea. Petrological study of this volcanic island has been made actively by Sang-Man Lee, Chong-Kwan won and Moon-Won Lee. The chronological measurements of the island by Chong-Kwan Won and Moon-Won Lee showed that it is composed of Sanbangsan trachytes and Backlokdam trachytes(25,000 year ago). These reports are based on the chemical analysis and the rediometric chronological measurements on the ground. However, there has been no reports about the inside of caves. We made an (composition) analysis of the inside of Manjang Cave by the fundamental parameter method in X-ray fluorescence spectrometry. The fundamental parameter method in X-ray fluorescence spectrometry is nondestructive analysis, and it enables us to make the values processed by a computer. The results obtained by this methods are as follows : SiO$_2$(49%), $Al_2$O$_3$(17%), Fe$_2$O$_3$(13%), CaO(8.1%), MgO(5.5%), Na$_2$O(3.6%), TiO$_2$(2.1%), $K_2$O(0.86%), P$_2$O$_{5}$(0.28%), and MnO(0.20%), respectively. The data obtained by the fundamental parameter method in X-ray fluorescence was compared with the data provided by Chong-Kwan and Moon-Won Lee. Our measurement was made by K-Ar-method in cooperation with T.ITAYA. The samples are of 30,000~420,000 year ago. The composition of the values of our underground analysis with the existing values obtained by the analyses on the ground produced new data about Cheju volcanic island.d.

  • PDF

The Determination of Rare Earth Oxides by X-Ray Fluorescence Spectrometry Using Empirical Coefficient Method (실험계수법을 이용한 희토류산화물의 X-선 형광분광분석)

  • Young Man Kim;Beom Suk Choi;Sun Tae Kim;Chong Wook Lee
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.64-70
    • /
    • 1987
  • Rare earth elements including Y and Th in the monazite were separated and determined by X-ray fluorescence spectrometry. The matrix effects among the rare earth elements were simultaneously corrected by means of empirical coefficient method. The values of the coefficients were quite dependent on the number of the standards. However, the different set of coefficients led to the same results. The analytical results corrected by the present method agreed with those by the inductively coupled plasma spectrometry.

  • PDF

Determination of Microamounts of Copper by Fluorescence X-Ray Analysis (형광 X-선 분석에 의한 미량 구리의 정량)

  • Choi Won-hyung;Kim Chan-ho
    • Journal of the Korean Chemical Society
    • /
    • v.16 no.6
    • /
    • pp.373-377
    • /
    • 1972
  • The analytical conditions for the fluorescence X-ray determination of small amount of cupper in solution were established. Copper in solution was extracted by diethyldithiocarbamate ethyl acetate and adsorbed by zinc powder. After drying, it was pressed to tablet under the pressure of $250Kg/cm^2.$$K_{\alpha}2(2{\theta}_{LiF} = 45.08^{\circ})$. The limit of detection was estimated to be about $10{\mu}g$ by the method of standard addition with an error of 10 %.

  • PDF

Low-level Determinations of Uranium and Thorium in Geologic Samples by X-ray Fluorescence (x-선 형광분석기톨 이용한 지질시료 중 우라늄과 토륨의 미량분석)

  • Park, Yong Joon;Kim, Jung Suk;Choi, Kwang Soon;Suh, Moo Yul
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.20-25
    • /
    • 1996
  • Trace levels of uranium and thorium in geologic samples are determined rapidly by a direct wavelength-dispersive X-ray fluorescence method. Relative intensity of scattered tube radiation was used as an internal standard to compensate for variations in instrumental operating characteristics. U and Th can be determined within a precision of ${\pm}10%$ and accuracy of ${\pm}15%$ or less with measuring times of 50 seconds for Th and 400 seconds for U, respectively. The results of XRF analysis were in good agreement with those of other methods such as nutron activation analysis and inductively coupled plasma atomic emission spectrometry.

  • PDF

Identification of natural colored diamonds using UV fluorescent and X-ray Lang images (UV 형광과 X-선 Lang 표면이미지를 이용한 천연유색다이아몬드의 감별 연구)

  • Kim, Jun-Hwan;Ha, Jun-Seok;Kim, Ki-Hoon;Song, Oh-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3540-3545
    • /
    • 2009
  • Due to recent development of high temperature high pressure(HTHP) diamond synthetic and treatment technology, we need to identify the natural diamonds fast, reliable, and economically. We proposed using new method of UV fluorescence and X-ray Lang topography imaging for distinguishing one synthetic diamond from four natural colored diamonds. We observe unique local stress field uneven image in synthetic diamond using UV fluorescence and Lang topography characterization, while uniform images in natural diamonds. Especially, X-ray Lang method offered the better identification power with better high resolution on stress field images.

The Allosteric Transition of the Chaperonin GroEL from Escherichia coli as Studied by Solution X-Ray Scattering

  • Kuwajima Kunihiro;Inobe Tomonao;Arai Munehito
    • Macromolecular Research
    • /
    • v.14 no.2
    • /
    • pp.166-172
    • /
    • 2006
  • This is a short review article of our recent studies on the ATP-induced, allosteric conformational transition of the chaperonin GroEL complex by solution X-ray scattering. We used synchrotron X-ray scattering with a two-dimensional, charge-coupled, device-based X-ray detector to study (1) the specificity of the chaperonin GroEL for its ligand that induced the allosteric transition, and (2) the identification of the allosteric transition of GroEL in its complicated kinetics induced by ATP. Due to the dramatically increased sensitivity of the X-ray scattering technique based on the use of the two dimensional X-ray detector and synchrotron radiation, different allosteric conformational states of GroEL populated under different conditions were clearly distinguished from each other. It was concluded that solution X-ray scattering is an extremely powerful tool for investigating the equilibrium and kinetics of cooperative conformational transitions of oligomeric protein complex, especially when combined with other spectroscopic techniques such as fluorescence spectroscopy.