• 제목/요약/키워드: x-ray film

검색결과 2,293건 처리시간 0.035초

Transport parameters in a-Se:As films for digital X-ray conversion material using the moving-photocarrier-grating technique

  • Park, Chang-Hee;Kim, Jeong-Bae;Kim, Jae-Hyung;Nam, Sang-Hee
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.305-306
    • /
    • 2005
  • The effects of As addition In amorphous selenium (a-Se) films for digital X-ray conversion material have been studied using the moving photocarrier grating (MPG) technique We have found an increase in hole drift mobility and recombination lifetime, especially when 0.3% As is added into a-Se film, whereas electron mobility decreases with As addition due to the defect density. The transport properties for As doped a-Se films obtained by using MPG technique have been compared with X-ray sensitivity for a-Se:As X-ray device. The fabricated a-Se (0.3%As) based X-ray detector exhibited the highest X-ray sensitivity of 5 samples.

  • PDF

X-선 산란을 이용한$SnO_{2}$ 박막의 결정구조 정밀화 (Crystal Structure Refinement of $SnO_{2}$ Thin Film Using X-ray Scattering)

  • 김용일;남승훈;박종서
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1939-1943
    • /
    • 2003
  • The precise structural analysis of $SnO_{2}$ thin film, which was prepared by PECVD and thickness 2400 ${\AA}$, was tried to do the structural refinement using X -ray diffraction data. The observed diffraction patterns of $SnO_{2}$ thin film had the strongly preferred orientation effect. WIMV method was used to correct the preferred orientation effect. The final weighted R-factor, $R_{WD}$ was 7.92 %. The lattice parameters, a = b == 4.7366(1) ${\AA}$ and c = 3.1937(1) ${\AA}$, were almost in accordance with ones of $SnO_{2}$ powder.

  • PDF

R. F. Sputter법으로 성장된 AIN 완충층이 GaN 박막결함에 미치는 영향 (Effect of AIN Buffers by R. F. Sputter on Defects of GaN Thin films)

  • 이민수
    • 한국전기전자재료학회논문지
    • /
    • 제17권5호
    • /
    • pp.497-501
    • /
    • 2004
  • The crystal structure of the GaN film on the AIN buffer layer grown by R. F sputtering with different thickness has been studied using X-ray scattering and transmission electron microscopy(TEM). The interface roughness between the AIN buffer layer and the epitaxial GaN film, due to crossover from planar to island grains, produced edge dislocations. The strain, coming from lattice mismatch between the AIN buffer layer and the epitaxial GaN film, produced screw dislocations. The density of the edge and screw dislocation propagating from the interface between the GaN film and the AIN buffer layer affected the electric resistance of GaN film.

Unveiling the direct conversion X-ray sensing potential of Brucinium benzilate and N-acetylglcyine

  • T. Prakash;C. Karnan;N. Kanagathara;R.R. Karthieka;B.S. Ajith Kumar;M. Prabhaharan
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2190-2194
    • /
    • 2024
  • The study investigates the dose-dependent direct X-ray sensing characteristics of Brucinium benzilate (BB) and N-acetylglycine (NAG) organic crystals. BB and NAG were prepared as a slurry and deposited as a thick film on a patterned metal electrode. The X-ray induced photocurrent response was examined for various exposure doses using an intraoral pulsed 70 keV X-ray machine connected to a source meter. Subsequently, the morphological properties and thickness of the thick films were analyzed using scanning electron microscopy (SEM). At a photon energy of 70 keV, the attenuation coefficient values for NAG and BB crystals were determined to be approximately 0.181 and 0.178 cm2/g, respectively. The X-ray stopping power of the crystals was measured using a suniray-2 X-ray imaging system. To evaluate the responsiveness of the sensors, the photocurrent sensitivity and noise equivalent dose rate (NED) were calculated for both thick films. The findings demonstrated a noteworthy capability of sensing low doses (mGy), thereby suggesting the potential application of these organic materials in X-ray sensor development.

근관 파일의 인지도 평가시 세 가지 디지털 방사선영상시스템의 비교 (Comparison of three digital radiographic imaging systems for the visibility of endodontic files)

  • 박종원;김은경;한원정
    • Imaging Science in Dentistry
    • /
    • 제34권3호
    • /
    • pp.145-150
    • /
    • 2004
  • Purpose: To compare three digital radiographic imaging sensors by evaluating the visibility of endodontic file tips with interobserver reproducibility and assessing subjectively the clarity of images in comparison with the x-ray film images. Materials and Methods: Forty-five extracted sound premolars were used for this study. Fifteen plaster blocks were made with three premolars each and #8, 10, 15 K-flexofiles were inserted into the root canal of premolars. They were radiographically exposed using periapical x-ray films (Kodak Insight Dental film, Eastmann Kodak company, Rochester, USA), Digora imaging plates (Soredex-Orion Co., Helsinki, Finland), CDX 2000HQ sensors (Biomedisys Co., Seoul, Korea), and CDR sensors (Schick Inc., Long Island, USA). The visibility of endodontic files was evaluated with interobserver reproducibility, which was calculated as the standard deviations of X, Y coordinates of endodontic file tips measured on digital images by three oral and maxillofacial radiologists. The clarity of images was assessed subjectively using 3 grades, i.e. plus, equal, and minus in comparison with the conventional x-ray film images. Results: Interobserver reproducibility of endodontic file tips was the highest in CDR sensor (p < 0.05) only except at Y coordinates of #15 file. In the subjective assessment of the image clarity, the plus grade was the most frequent in CDR sensor at all size of endodontic file (p < 0.05). Conclusion : CDR sensor was the most superior to the other sensors, CDX 2000HQ sensor and Digora imaging plate in the evaluation of interobserver reproducibility of endodontic file tip and subjective assessment of image clarity.

  • PDF

가열장치를 구비한 부착형 탄소발열체 X선 촬영대 고안 (Design for Adhesive Carbon Heating Element X-ray Table with an Attached Heating Device)

  • 송종남;김응곤
    • 한국방사선학회논문지
    • /
    • 제9권3호
    • /
    • pp.131-137
    • /
    • 2015
  • 본 연구의 목적은 기존에 사용 중인 X선 발생장치의 촬영대를 따뜻하게 가열하면서도 X선 감약이 적은 탄소나노튜브(carbon nano tube, CNT) 발열체를 사용하여 가열장치를 구비한 X선 발생장치용 부착형 촬영대의 고안 및 설계를 하고자 한다. 고안된 제품의 구성은 부착형 탄소발열체 촬영대로서 기존 X선 촬영대, 탄소나노튜브 면상발열체, 전극선, 난연 처방된 보호필름과 바닥필름으로 구성되어 있다. 본 고안 제품의 특징과 장점은 냉기(冷氣)를 느끼는 촬영대에서 환의를 착용하고 검사를 받는 환자에게 온화한 느낌과 안전감을 제공하고 심적인 불안감을 해소하여 검사에 도움을 줄 수 있기 때문에 임상 적용을 적극 권장하는 바이다.

미세혈관 조영술에 의한 미세혈관 문합후의 혈류재개에 대한 실험적 연구 (An Experimental Study Microvascular Patency by Micro-Arteriography Using Dental X-ray and Film)

  • 정필훈
    • 대한치과의사협회지
    • /
    • 제23권1호통권188호
    • /
    • pp.73-81
    • /
    • 1985
  • In the assessment of patency of a small vessel anastomosis, micro-arteriography using dental X-ray and film was used as a method of testing the patency of arterial anastomoses in the rat. Micro-arteriography could lead to an objective evaluation of the patency in End-to-End and End-to Side anastomoses. The method used in this study is easily accessible for Oral and Maxillo-facial surgeon to practice the microvascular anastomosis, and requires materials available in every dental clinic.

  • PDF

상업용 Black Chrome 태양선택 흡수면의 특성 (Characterization of a Commercial Black Chrome Solar Coating)

  • 이길동;최영희;오정무
    • 태양에너지
    • /
    • 제7권2호
    • /
    • pp.65-73
    • /
    • 1987
  • Microstructural basis for the thermal degradation of electrodeposited black chrome "solar-L-foil" heated in air has been investigated using scanning electron microscopy, energy dispersive x-ray analysis, X-ray diffraction techniques and UV-VIS-NIR spectre-photometer. Experimental result, the change in the shape of the particle comprising the film from their initial needle like structure to a more spherical shape with an oxide after 1hr annealing at $600^{\circ}C$ has been observed. The effect is to degrade solar absorptance of the thin film.

  • PDF

Thermal Transitions of the Drawn Film of a Nylon 6/Layered Silicate Nanocomposite

  • Park Soo-Young;Cho Yang-Hwan
    • Macromolecular Research
    • /
    • 제13권2호
    • /
    • pp.156-161
    • /
    • 2005
  • The thermal transitions of a nylon 6/layered silicate nanocomposite were studied by differential scanning calorimetry and in-situ synchrotron X-ray diffraction. The drawn film of the nylon 6/layered silicate nanocomposite typically showed three endotherms in the DSC thermogram; a very broad endotherm at $\sim120^{\circ}C(T_{1})$, a double-melting endotherm at $\sim215^{\circ}C(T_{2})$, and a high temperature endotherm at $\sim240^{\circ}C(T_{3})$. The drawn film of the nylon 6/ layered silicate nanocomposite was comprised of a mixture of the $\alpha and \gamma$ forms, with $the \alpha form$ being generated by drawing the pressed film having $the \gamma form$. The melting and crystallization of the crystals were observed at the above thermal transitions during the heating experiment performed at the Pohang X-ray synchrotron radiation source (4C2). The newly generated form was meta-stable and melted $at {\sim}T_{1}$. The double-melting $at {\sim}T_{2}$ was due to the exothermic crystallization of $the \alpha form$ during the main endothermic melting of $the \gamma form$. $The \alpha form$ crystallized $at {\sim}T_{2}$ and melted $at {\sim}T_{3}$.