• Title/Summary/Keyword: worst-case analysis

Search Result 294, Processing Time 0.029 seconds

Analysis on Coexistence between Unlicensed Wireless Device based on 802.11ah and LTE User Equipment (802.11ah 기반 비면허 무선기기와 LTE 단말기 간 공존 분석)

  • Lee, Il-Kyoo;Park, Yeon-Gyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.11
    • /
    • pp.2015-2021
    • /
    • 2017
  • Recently, a lot of attention is fallen to IoT(Internet of Things) for hyper-connected society and the number of unlicensed wireless device has been increasing. Thus, this paper analyzed the impact of unlicensed wireless device on the basis of 802.11ah on licensed LTE user equipment in 900 MHz frequency band for efficient frequency use. As the interference analysis method, Minimum Coupling Loss (MCL) method and Monte Carlo (MC) method were used. In case of one interferer, minimum separation distance between interferer and victim was calculated as about 22 m through the MCL method under the assumption of the worst case. The maximum number of interferer to meet the interference probability of 5% below within a cell radius of the victim was computed as about 3000 by using MC method based on statistical technique. The analysis method and results in this paper are expected to be used for the coexistence between unlicensed wireless device and licensed wireless device.

Critical earthquake input energy to connected building structures using impulse input

  • Fukumoto, Yoshiyuki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • v.9 no.6
    • /
    • pp.1133-1152
    • /
    • 2015
  • A frequency-domain method is developed for evaluating the earthquake input energy to two building structures connected by viscous dampers. It is shown that the earthquake input energies to respective building structures and viscous connecting dampers can be defined as works done by the boundary forces between the subsystems on their corresponding displacements. It is demonstrated that the proposed energy transfer function is very useful for clear understanding of dependence of energy consumption ratios in respective buildings and connecting viscous dampers on their properties. It can be shown that the area of the energy transfer function for the total system is constant regardless of natural period and damping ratio because the constant Fourier amplitude of the input acceleration, relating directly the area of the energy transfer function to the input energy, indicates the Dirac delta function and only an initial velocity (kinetic energy) is given in this case. Owing to the constant area property of the energy transfer functions, the total input energy to the overall system including both buildings and connecting viscous dampers is approximately constant regardless of the quantity of connecting viscous dampers. This property leads to an advantageous feature that, if the energy consumption in the connecting viscous dampers increases, the input energies to the buildings can be reduced drastically. For the worst case analysis, critical excitation problems with respect to the impulse interval for double impulse (simplification of pulse-type impulsive ground motion) and multiple impulses (simplification of long-duration ground motion) are considered and their solutions are provided.

A Case Study of Hospital Business Analysis (병원경영분석에 관한 사례연구)

  • Lee, Eun-Hyung;Jung, Key-Sun;Do, Key-Hyun;Kim, Young-Bae
    • Korea Journal of Hospital Management
    • /
    • v.17 no.1
    • /
    • pp.79-112
    • /
    • 2012
  • The purpose of this study is to examine the differences of profitability based on the analysis of business and medical service performances of four hospitals in Incheon area with similar size. and to compare hospitals with the best and the worst performances and analyze the factors behind the differences. The differences could be caused by differences in medical service statistics, number of staff, and financial results, etc. The data was acquired through the homepage of the National Tax Service(financial statements for the fiscal year 2009) and the Medical Record Association of Incheon(medical service statistics for the years 2008 and 2009) along with questionnaire survey to the hospitals(personnel data for the year 2009). The results of the study are as follows. Medical profits to medical revenues ratio for the hospitals(referred as Hospital A, B, C, and D) shows, in order, C(8.2%), A(8.0%), B(7.8%), and D(7.4%). However, net income to medical revenues ratio shows otherwise: C(8.5%), D(5.8%), A(3.0%), and B(0.6%). Hospital B shows a high medical profit to revenue ratio but the lowest net income to revenue ratio due to large interest expenses. The leverage ratio of Hospital B is the highest (419.6%), resulting in a very low interest coverage ratio(1.1). On the other hand, Hospital C shows favorable results in both profit ratios, with 8.2% and 8.5% each. Hospital C has the lowest leverage ratio(53.0%) and the highest interest coverage ratio(34.9). Therefore, the results show Hospital C has the best performance while Hospital B the worst. The two hospitals(B and C) show similar results in certain areas and big differences in other areas. The area that has the biggest influence on financial results turns out leverage ratio. Hospital B shows 'very good' to 'good' results in terms of medical service statistics in general. However, the leverage ratio is too high and the liquidity ratio too low, resulting in a very low profit ratio. The results of this study have some limitations in terms of generalization as only four hospitals in Incheon area were selected for the study, resulting in a deficiency in the representativeness of the sample. Further studies with bigger sample size and deeper analysis are expected in this area.

  • PDF

A RFID Tag Anti-Collision Algorithm Using 4-Bit Pattern Slot Allocation Method (4비트 패턴에 따른 슬롯 할당 기법을 이용한 RFID 태그 충돌 방지 알고리즘)

  • Kim, Young Back;Kim, Sung Soo;Chung, Kyung Ho;Ahn, Kwang Seon
    • Journal of Internet Computing and Services
    • /
    • v.14 no.4
    • /
    • pp.25-33
    • /
    • 2013
  • The procedure of the arbitration which is the tag collision is essential because the multiple tags response simultaneously in the same frequency to the request of the Reader. This procedure is known as Anti-collision and it is a key technology in the RFID system. In this paper, we propose the 4-Bit Pattern Slot Allocation(4-BPSA) algorithm for the high-speed identification of the multiple tags. The proposed algorithm is based on the tree algorithm using the time slot and identify the tag quickly and efficiently through accurate prediction using the a slot as a 4-bit pattern according to the slot allocation scheme. Through mathematical performance analysis, We proved that the 4-BPSA is an O(n) algorithm by analyzing the worst-case time complexity and the performance of the 4-BPSA is improved compared to existing algorithms. In addition, we verified that the 4-BPSA is performed the average 0.7 times the query per the Tag through MATLAB simulation experiments with performance evaluation of the algorithm and the 4-BPSA ensure stable performance regardless of the number of the tags.

Energy Balance and Power Performance Analysis for Satellite in Low Earth Orbit

  • Jang, Sung-Soo;Kim, Sung-Hoon;Lee, Sang-Ryool;Choi, Jae-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.3
    • /
    • pp.253-262
    • /
    • 2010
  • The electrical power system (EPS) of Korean satellites in low-earth-orbit is designed to achieve energy balance based on a one-orbit mission scenario. This means that the battery has to be fully charged at the end of a one-orbit mission. To provide the maximum solar array (SA) power generation, the peak power tracking (PPT) method has been developed for a spacecraft power system. The PPT is operated by a software algorithm, which tracks the peak power of the SA and ensures the battery is fully charged in one orbit. The EPS should be designed to avoid the stress of electronics in order to handle the main bus power from the SA power. This paper summarizes the results of energy balance to achieve optimal power sizing and the actual trend analysis of EPS performance in orbit. It describes the results of required power for the satellite operation in the worst power conditions at the end-of-life, the methods and input data used in the energy balance, and the case study of energy balance analyses for the normal operation in orbit. Both 10:35 AM and 10:50 AM crossing times are considered, so the power performance in each case is analyzed with the satellite roll maneuver according to the payload operation concept. In addition, the data transmission to the Korea Ground Station during eclipse is investigated at the local-time-ascending-node of 11:00 AM to assess the greatest battery depth-of-discharge in normal operation.

The Case Analysis through Fire Simulation FDS and Evacuation Simulation Pathfinder (화재 시뮬레이션 FDS와 피난시뮬레이션 Pathfinder 사례분석)

  • Kim, Jong Yoon;Jeon, Yong Han
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.6
    • /
    • pp.253-260
    • /
    • 2015
  • In this study, using the FDS as the fire simulation and evacuation simulations of the Pathfinder, set the main control room of the building to the fire point fire safety assessment studies were carried out. At first the quantitative result such as distribution of visibility as time passing, distribution of temperature, distribution of CO density produced results using fire-simulation and evacuation-simulation was carried out based on the result that produced the final safety evaluation result as being calculated of evacuation time. As the risk increased with the distribution of visibility at the result of fire-simulation, evacuation-simulation was carried out using the result. Finally the result was made 127.9 sec that everyone could evacuate. The numerical results are analyzed in case of the places in the building required safe egress time for safety a as the analysis to be no more than available safe egress time was analyzed to be secured. The results of this safety evaluation represent that more smooth evacuation safety performance can be secured by linking the event of fire firefighting equipment as a result of simulating the worst conditions.

  • PDF

Stress Dependence of Thermal Stability of Nickel Silicide for Nano MOSFETs

  • Zhang, Ying-Ying;Lee, Won-Jae;Zhong, Zhun;Li, Shi-Guang;Jung, Soon-Yen;Lee, Ga-Won;Wang, Jin-Suk;Lee, Hi-Deok;Lim, Sung-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.110-114
    • /
    • 2007
  • Dependence of the thermal stability of nickel silicide on the film stress of inter layer dielectric (ILD) layer has been investigated in this study and silicon nitride $(Si_3N_4)$ layer is used as an ILD layer. Nickel silicide was formed with a one-step rapid thermal process at $500^{\circ}C$ for 30 sec. $2000{\AA}$ thick $Si_3N_4$ layer was deposited using plasma enhanced chemical vapor deposition after the formation of Ni silicide and its stress was split from compressive stress to tensile stress by controlling the power of power sources. Stress level of each stress type was also split for thorough analysis. It is found that the thermal stability of nickel silicide strongly depends on the stress type as well as the stress level induced by the $Si_3N_4$ layer. In the case of high compressive stress, silicide agglomeration and its phase transformation from the low-resistivity nickel mono-silicide to the high-resistivity nickel di-silicide are retarded, and hence the thermal stability is obviously improved a lot. However, in the case of high tensile stress, the thermal stability shows the worst case among the stressed cases.

원격측정명령처리기 성능검증모델 개발

  • Kim, Joong-Pyo;Koo, Cheol-Hea;Choi, Jae-Dong;Chae, Jong-Won;Kim, Jung-Hoon;Koo, Ja-Chun
    • Aerospace Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.86-94
    • /
    • 2005
  • This paper shows the results of design, analysis, manufacturing and test performed to develop the CTU(Command Telemetry Unit) EQM(Engineering Qualification Model). According to the key requirement specifications, the logics and circuits of each board are designed. In order to validate designs, some worst case, part stress, reliability, FMECA, radiation environment and launch environment analyses are performed. After manufacturing and assembling all boards, all functions of CTU EQM are verified through the functional test, environmental test and ETB test.

  • PDF

Dynamic Analysis on the Construction of the Innovative City (혁신도시 건설에 관한 동태적 분석)

  • Lee, Man-Hyung;Kim, Yeon-Sik;Kim, Mi-Sung;Hong, Sung-Ho
    • Korean System Dynamics Review
    • /
    • v.8 no.2
    • /
    • pp.141-173
    • /
    • 2007
  • In Korean context, the innovative cities imply new towns or urban clusters in the Non Capital Regions, all of which would accommodate the relocated Capital based public organizations. The central government-initiated innovative cities have provoked pros and cons towards their effectiveness and efficacy for the balanced territorial development. From a broader prospective, this paper firstly examines the current status quo of the innovative cities. Based on their master plans, it analyzes physical and non physical factors which would exert significant impact on the innovative cities. Secondly, it pays attention to how key factors strengthen or weaken their behavioral patterns in terms of dynamic location and implementation policies of the innovative cities. Using System dynamics approaches, it sets up couples of scenarios, categorizing between supporting and opposing arguments towards the innovative cities. Lastly, after divulging systematic structure of the innovative cities, it proposes a series of practical alternatives which would contribute to minimizing unexpected side effects or unwanted social cost in the long run. In order to guarantee reinforcing structure of the innovative cities, the paper suggests that QOL (quality of life) variables, which would require continuous investment in the social infrastructure, are pivotal in achieving original goals of the innovative cities. Otherwise, the innovative cities would not be innovative per se. In the worst case, they might be degraded into the unpopular ghost towns.

  • PDF

Geographical Analysis on Network Reliability of Public Transportation Systems:A Case Study of Subway Network System in Seoul (대중 교통망의 네트워크 신뢰도에 관한 지리학적 분석 -서울시 지하철망을 대상으로-)

  • Kim, Hyun
    • Journal of the Korean Geographical Society
    • /
    • v.44 no.2
    • /
    • pp.187-205
    • /
    • 2009
  • Failures on network components of a public transportation system can give rise to the severe degradation of entire system functionality. This paper aims at exploring how potential failures can affect the system flows and reliability of subway network systems in Metropolitan Seoul. To evaluate the range of impacts of disruptions, this research employs a probabilistic approach, network reliability. Network reliability measures the network resiliency and probability of flow loss under a variety of simulated disruptions of critical network components, transfer stations in subway system. By identifying the best and worst scenarios associated with geographical impact, as well as evaluating the criticality of transfer stations, this research presents some insights for protecting current subways systems.