• 제목/요약/키워드: wiring

검색결과 517건 처리시간 0.034초

구내통신의 배선구조와 광대역 전기적 특성 (The structrue and wideband electrical characteristics of premises telecommunicatin wiring)

  • 이강식;김창락;류명주;서태석
    • 한국통신학회논문지
    • /
    • 제23권9A호
    • /
    • pp.2165-2172
    • /
    • 1998
  • Existing premises telecommucation wiring ad been installed for efficient telephone service. But premises wiring is currently ready to be reused as media for wideband digital services and Fiber-to-the-curb architecture. Electrical properties of premises wiring link have not characateized above frequencies for voice service. Accurte measurement of these characteristics are exssential for studies fof wideband ditital transmission system. On the other hand, the transmission qualities of premises wiring have been known to be worst in telecommunications access networks. So the knowledge of premises wiring sturucture as well as electrical properties is needed to improve the performance of premises wiring. In this paper, the structure of premises wiring is described in detail and electrical characteristics (characteristic impedance, SRL, attnuation, NEXT) about premises cables and stelecommucations link of representative apartment complex sare measured and naalyzed ove r16MHz range which is UTP Cat3 bandwidth.

  • PDF

PCB 디자인 시뮬레이터 구현에 관한 연구 (A Study on Implementation for the PCB Design Simulator)

  • 김현호;우경환;이천희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.296-296
    • /
    • 2000
  • This paper describes the features of a transmission line and a wiring, and a design rule based on a demanded condition for a wiring. Like as the simulation of a circuit, by tracking the wiring path among parts that are disposed on PCB, we analyze the feature of the corresponding wiring using the design formula and rule. We implement a signal integrity simulator, which is capable of electrical and electronic simulation for the feature of a wiring signal and the corresponding signal, and the results are demonstrated.

  • PDF

시기별 Wiring 처리가 '신고' 배의 과실품질 및 수체 내 탄수화물과 무기성분에 미치는 영향 (Effects of Seasonal Wiring Treatments on Fruit Quality, Carbohydrates, and Mineral Nutrients of 'Niitaka' (Pyrus pyrifolia Nakai) Pear Trees)

  • 서인호;송장훈;서호진
    • 한국유기농업학회지
    • /
    • 제27권1호
    • /
    • pp.33-44
    • /
    • 2019
  • 본 연구는 배 주요재배 품종인 신고를 이용하여 생장조절제인 지베렐린과 환상박피 효과를 대체 할 수 있는 재배기술을 개발하고자 수행하였다. ${\Phi}3.0mm$인 철사를 사용하여 시기별로 만개 후 70, 80, 90, 110, 130일에 주간에 wiring 처리 후 과실품질 및 수확 후 저장성에 미치는 영향에 대하여 조사하였다. 과실의 과중과 당함량을 조사한 결과 처리시기가 늦은 만개 후 110일 처리구가 다른 처리구와 비교해서 높은 증진 효과를 나타냈으며 처리시기가 빠를수록 낮은 결과를 나타냈다. 산함량은 wiring 처리구가 무처리구보다 낮은 함량을 보였고, 경도는 처리구간 유의적인 차이는 나타나지 않았다. 과피 착색은 무처리구에서 가장 낮은 L값을 보였으나 처리 간 유의적인 차이는 보이지 않았다. 만개 후 110일과 130일 처리구에서 a값이 가장 높게 나타났는데 이는 wiring 처리가 과실의 숙기에 영향을 미치는 것으로 판단된다. 수확 후 저장 60일, 90일 후 과중 변화는 만개 후 110일 처리구에서 가장 낮은 감모율을 보였으며, 당함량과 산함량, 경도는 처리구간 유의적인 차이가 없었다. 저장 기간 중 과실의 밝기를 나타내는 L값은 모든 처리구에서 유의적인 차이가 나타나지 않았으나 a값을 조사한 결과 90, 110일 처리구가 다른 처리구보다 높게 조사되어 처리시기에 따라 a값이 다르게 나타났다. 꽃눈의 생체중과 크기는 처리구간 유의적인 차이는 나타나지 않았다. 꽃눈의 무기성분 함량은 만개 후 80일 처리구에서 K (0.63%)과 Mg (0.31%) 함량이 가장 높았고, Ca과 P의 함량은 처리간 유의적인 차이는 없었다. 잎 내 K 함량은 만개 130일 처리구(0.76%)와 무처리구에서 (0.78%) 함량이 낮았고, Ca과 P의 함량은 처리간 유의적인 차이는 없었다. wiring 처리시기가 늦어짐에 따라 꽃눈의 탄수화물 함량은 곡선형의 상관관계를 보였고 잎의 탄수화물과는 부의 상관관계가 관찰되었다.

옥내배선 길이에 따른 단락 특성의 실험적 연구 (An Experimental Study on Short Circuit Characteristics by the Interior Wiring Length)

  • 송재용;김진표;조영진;최돈묵;오부열;길경석
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.38-42
    • /
    • 2012
  • This paper describes electrical fire on residential environment such as apartment and detached house caused by defect of interior wiring. We carried out experimental study on short circuit characteristics by the interior wiring length. We were measured arc current, arc energy and interrupting time of earth leakage current circuit breaker(ELB), when an interior wiring break out short circuit in residential environment. From the experiment results, the longer of the interior wiring, the magnitude of arc current decreased and the interrupting time of ELB increased. When applied the A maker's ELB, the strength of arc current and interrupting time of ELB was 254 A and 245 ms respectively at 30 m interior wiring length. In 3 m interior wiring length, arc current and interrupting time was 716 A and 4.24 ms respectively. Arc energy was dependent on the magnitude of arc current and the interrupting time of ELB, the longer the interrupting time, arc energy increasing. In this paper, minimum arc energy was 277 J using C maker's ELB and 3 m interior wiring length(arc current 283 A, interrupting time of breaker 6.28 ms). Therefore in the residential environment, short circuit caused by defect of the interior wiring lead to electrical fire.

The Role of a Wiring Model in Switching Cell Transients: the PiN Diode Turn-off Case

  • Jedidi, Atef;Garrab, Hatem;Morel, Herve;Besbes, Kamel
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.561-569
    • /
    • 2017
  • Power converter design requires simulation accuracy. In addition to the requirement of accurate models of power semiconductor devices, this paper highlights the role of considering a very good description of the converter circuit layout for an accurate simulation of its electrical behavior. This paper considers a simple experimental circuit including one switching cell where a MOSFET transistor controls the diode under test. The turn-off transients of the diode are captured, over which the circuit wiring has a major influence. This paper investigates the necessity for accurate modeling of the experimental test circuit wiring and the MOSFET transistor. It shows that a simple wiring inductance as the circuit wiring representation is insufficient. An adequate model and identification of the model parameters are then discussed. Results are validated through experimental and simulation results.

차량용 와이어링 하네스 개선을 위한 브릿지 커넥터 개발에 관한 연구 (A Study of Bridge Connector Development on Wiring Harness Improvement in Vehicles)

  • 류수욱;박경석
    • 한국기계가공학회지
    • /
    • 제9권2호
    • /
    • pp.66-72
    • /
    • 2010
  • Recently a large number of electronic control devices are abruptly increasing in vehicles as the electronic industry advances. Also the number of wiring harnesses and complexity of wiring is proportionally increased to the devices. A newly developed connector named bridge connector is introduced in this study for the purpose of the wiring structure changes. A wiring structure among distributed control systems by using serial communication is proposed with the bridge connector in this paper. The bridge connector contains a auto-recovery fuse made by PTC thermistor material for the protection of the over-currents on local control devices. The auto-recovery function of the fuse is needed for the maintenance free system in the distributed controls. The PTC fuse characteristics organized in this study is tested and the results are showed in detail for the real application.

Ag 인쇄배선과 이종재료기판과의 접합계면 (Interfacial Microstructures between Ag Wiring Layers and Various Substrates)

  • 김근수;;허석환
    • Journal of Welding and Joining
    • /
    • 제29권5호
    • /
    • pp.90-94
    • /
    • 2011
  • Ag metallic particles from nano-scale to submicron-scale are combined with organic solvent to provide fine circuits and interconnection. Ink-jet printing with Ag nano particle inks demonstrated the potentials of the new printed electronics technology. The bonding at the interface between the Ag wiring layer and the various substrates is very important. In this study, the details of interfaces in Ag wiring are investigated primarily by microstructure observation. By adjusting the materials and sintering conditions, nicely formed interfaces between Ag wiring and Cu, Au or organic substrates are achieved. In contrast, transmission electron microscope (TEM) image clearly shows interface debonding between Ag wiring and Sn substrate. Sn oxides are formed on the surface of the Sn plating. The formation of these is a root cause of the interface debonding.

주두골(肘頭骨) 골절치료(骨折治療)에 있어 Tension Band Wiring의 효과 (The Effect of Tension Band Wiring in the Treatment of the Olecranon Fracture)

  • 인주철;안종철;김세동;안면환;서재성
    • Journal of Yeungnam Medical Science
    • /
    • 제2권1호
    • /
    • pp.59-63
    • /
    • 1985
  • 저자들은 tension band wiring을 이용하여 주두골골절을 치료하여 그 결과를 분석하여 tension band wiring이 주두골골절의 치료에 매우 효과적이란 결론을 얻었기에 보고하는 바이다.

  • PDF

BIPV시스템 시공 및 프레임 성능저하를 고려한 배선처리방안 제시에 관한 연구 (A Study on the Wiring Plan Considering Construction and Frame Performance Degradation of BIPV System)

  • 오민석;김기철
    • 한국태양에너지학회 논문집
    • /
    • 제38권4호
    • /
    • pp.33-42
    • /
    • 2018
  • In the application of the BIPV system, it is expected that the workability is lowered due to the difficulty in securing the space for wiring in the frame and the performance of the frame due to the wiring hole processing is lowered. Therefore, In this study, we propose a method to improve the wiring of the inner space of the BIPV frame, and through the simulation evaluation process, the thermal and condensation performance are secured by complementing the problems caused by the hole machining, and the time and effort required for BIPV construction are reduced. For this purpose, a wiring treatment method using a flange insertion tube was proposed, and the thermal and condensation performance was evaluated through simulation analysis.

항공기 배선 결함 식별을 위한 TDR(시간영역 반사계) 활용 적합성 (Validation on Usability of Time Domain Reflectometer for Identifying Defected Aircraft Wiring)

  • 김수웅;이장룡
    • 한국항행학회논문지
    • /
    • 제24권3호
    • /
    • pp.205-211
    • /
    • 2020
  • 배선 결함은 안전한 항공기 운항에 커다란 영향을 미친다. 그러나 배선 결함의 고장탐구 과정은 광범위하고 복잡한 배선 시스템과 설치 위치 때문에 매우 어렵다. 최근 국내 항공사에 배선 결함 고장탐구를 효과적으로 할 수 있게 해주는 시간영역 반사계(TDR; time domain refelectometer) 장비가 소개되었다. 하지만 TDR의 효과와 유용성이 검증되지 않아 대부분의 항공사 정비 부서에서 TDR은 실질적으로 거의 사용되고 있지 않다. 본 연구는 TDR이 항공기 배선에서 결함의 위치 및 유형을 식별하여 문제 해결에 적용될 수 있는지 여부를 결정하기 위해 수행되었다. 실제 항공기에 적용되는 다양한 전선 및 연결부품을 이용한 여러 실험 계획을 수립하여 관찰된 실험 결과를 장비 운용 가이드에서 제공된 데이터와 비교하였다. 실험 결과, 양쪽의 데이터가 유사함을 볼 수 있었으며 TDR은 실제 항공기 배선 결함 고장탐구시 활용 적합성이 있음을 확인하였다.