• Title/Summary/Keyword: wiring

Search Result 517, Processing Time 0.025 seconds

The structrue and wideband electrical characteristics of premises telecommunicatin wiring (구내통신의 배선구조와 광대역 전기적 특성)

  • 이강식;김창락;류명주;서태석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.9A
    • /
    • pp.2165-2172
    • /
    • 1998
  • Existing premises telecommucation wiring ad been installed for efficient telephone service. But premises wiring is currently ready to be reused as media for wideband digital services and Fiber-to-the-curb architecture. Electrical properties of premises wiring link have not characateized above frequencies for voice service. Accurte measurement of these characteristics are exssential for studies fof wideband ditital transmission system. On the other hand, the transmission qualities of premises wiring have been known to be worst in telecommunications access networks. So the knowledge of premises wiring sturucture as well as electrical properties is needed to improve the performance of premises wiring. In this paper, the structure of premises wiring is described in detail and electrical characteristics (characteristic impedance, SRL, attnuation, NEXT) about premises cables and stelecommucations link of representative apartment complex sare measured and naalyzed ove r16MHz range which is UTP Cat3 bandwidth.

  • PDF

A Study on Implementation for the PCB Design Simulator (PCB 디자인 시뮬레이터 구현에 관한 연구)

  • 김현호;우경환;이천희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.296-296
    • /
    • 2000
  • This paper describes the features of a transmission line and a wiring, and a design rule based on a demanded condition for a wiring. Like as the simulation of a circuit, by tracking the wiring path among parts that are disposed on PCB, we analyze the feature of the corresponding wiring using the design formula and rule. We implement a signal integrity simulator, which is capable of electrical and electronic simulation for the feature of a wiring signal and the corresponding signal, and the results are demonstrated.

  • PDF

Effects of Seasonal Wiring Treatments on Fruit Quality, Carbohydrates, and Mineral Nutrients of 'Niitaka' (Pyrus pyrifolia Nakai) Pear Trees (시기별 Wiring 처리가 '신고' 배의 과실품질 및 수체 내 탄수화물과 무기성분에 미치는 영향)

  • Seo, In-Ho;Song, Jang-Hoon;Seo, Ho-Jin
    • Korean Journal of Organic Agriculture
    • /
    • v.27 no.1
    • /
    • pp.33-44
    • /
    • 2019
  • This study was initiated to find possibility of substitute of gibberellin acid and to prevent negative girdling effect such as slow growth of 'Niitaka' (Pyrus pyrifolia Nakai) trees, a major pear cultivar, at harvest and at 60-, 90-, and 120-d after storage. Seasonal wiring with 3.0-mm-diameter were applied on the main branch at 70, 80, 90, 110, and 130 days after full bloom (DAF) to compare the fruit quality and storability. Fruit weight and sugar contents were the greatly increased by the wiring treatment at 110 DAF, with the lowest values observed for the wiring at 70 DAF. All the wiring treatments reduced fruit acidity but did not affect fruit firmness. a-value on fruit skin was the highest for wiring at 110 DAF and 130 DAF, advancing fruit ripening. The lowest fruit weight loss was occurred at wiring at 110 DAF. a-value on fruit skin was the highest for wiring at 90 DAF and 110 DAF. Wiring at 80 DAF the most increased floral bud diameter, resulting in the lowest L:D ratio of 1.74 observed. As for the mineral nutrients concentrations of floral buds, the concentration of K (0.63%) and Mg (0.31%) were the highest after 80 DAF wiring treatment, whereas Ca and P concentrations did not differ among treatment plots. The leaf K concentrations was the highest in the 130-day wiring treatment (0.76%) and in the control plot (0.78%), whereas there was no significant difference in the concentrations of either Ca or P among treatment plots. Short periods of wiring increased foliar Mg concentrations. In floral buds, carbohydrates showed a tendency for accumulating at a lower concentrations (7.75%) after 70 DAF wiring treatment, which was a relatively short treatment period. On the other hand, the carbohydrate concentrations in leaves showed a tendency for accumulating at lower concentrations after 130 DAF wiring treatment (2.51%), which is a long treatment period, and in the control plot (2.43%). Wiring increased the size and sugar content of fruits, and influenced fruit storability. For the wiring treatment period was delayed, the carbohydrate concentration in flower buds showed curvilinear correlation and the negative correlation with the carbohydrate in leaf tissue.

An Experimental Study on Short Circuit Characteristics by the Interior Wiring Length (옥내배선 길이에 따른 단락 특성의 실험적 연구)

  • Song, J.Y.;Kim, J.P.;Cho, Y.J.;Choi, D.M.;Oh, B.Y.;Kil, G.S.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.4
    • /
    • pp.38-42
    • /
    • 2012
  • This paper describes electrical fire on residential environment such as apartment and detached house caused by defect of interior wiring. We carried out experimental study on short circuit characteristics by the interior wiring length. We were measured arc current, arc energy and interrupting time of earth leakage current circuit breaker(ELB), when an interior wiring break out short circuit in residential environment. From the experiment results, the longer of the interior wiring, the magnitude of arc current decreased and the interrupting time of ELB increased. When applied the A maker's ELB, the strength of arc current and interrupting time of ELB was 254 A and 245 ms respectively at 30 m interior wiring length. In 3 m interior wiring length, arc current and interrupting time was 716 A and 4.24 ms respectively. Arc energy was dependent on the magnitude of arc current and the interrupting time of ELB, the longer the interrupting time, arc energy increasing. In this paper, minimum arc energy was 277 J using C maker's ELB and 3 m interior wiring length(arc current 283 A, interrupting time of breaker 6.28 ms). Therefore in the residential environment, short circuit caused by defect of the interior wiring lead to electrical fire.

The Role of a Wiring Model in Switching Cell Transients: the PiN Diode Turn-off Case

  • Jedidi, Atef;Garrab, Hatem;Morel, Herve;Besbes, Kamel
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.561-569
    • /
    • 2017
  • Power converter design requires simulation accuracy. In addition to the requirement of accurate models of power semiconductor devices, this paper highlights the role of considering a very good description of the converter circuit layout for an accurate simulation of its electrical behavior. This paper considers a simple experimental circuit including one switching cell where a MOSFET transistor controls the diode under test. The turn-off transients of the diode are captured, over which the circuit wiring has a major influence. This paper investigates the necessity for accurate modeling of the experimental test circuit wiring and the MOSFET transistor. It shows that a simple wiring inductance as the circuit wiring representation is insufficient. An adequate model and identification of the model parameters are then discussed. Results are validated through experimental and simulation results.

A Study of Bridge Connector Development on Wiring Harness Improvement in Vehicles (차량용 와이어링 하네스 개선을 위한 브릿지 커넥터 개발에 관한 연구)

  • Ryu, Su-uk;Park, Kyoung-Seok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.2
    • /
    • pp.66-72
    • /
    • 2010
  • Recently a large number of electronic control devices are abruptly increasing in vehicles as the electronic industry advances. Also the number of wiring harnesses and complexity of wiring is proportionally increased to the devices. A newly developed connector named bridge connector is introduced in this study for the purpose of the wiring structure changes. A wiring structure among distributed control systems by using serial communication is proposed with the bridge connector in this paper. The bridge connector contains a auto-recovery fuse made by PTC thermistor material for the protection of the over-currents on local control devices. The auto-recovery function of the fuse is needed for the maintenance free system in the distributed controls. The PTC fuse characteristics organized in this study is tested and the results are showed in detail for the real application.

Interfacial Microstructures between Ag Wiring Layers and Various Substrates (Ag 인쇄배선과 이종재료기판과의 접합계면)

  • Kim, Keun-Soo;Suganuma, Katsuaki;Huh, Seok-Hwan
    • Journal of Welding and Joining
    • /
    • v.29 no.5
    • /
    • pp.90-94
    • /
    • 2011
  • Ag metallic particles from nano-scale to submicron-scale are combined with organic solvent to provide fine circuits and interconnection. Ink-jet printing with Ag nano particle inks demonstrated the potentials of the new printed electronics technology. The bonding at the interface between the Ag wiring layer and the various substrates is very important. In this study, the details of interfaces in Ag wiring are investigated primarily by microstructure observation. By adjusting the materials and sintering conditions, nicely formed interfaces between Ag wiring and Cu, Au or organic substrates are achieved. In contrast, transmission electron microscope (TEM) image clearly shows interface debonding between Ag wiring and Sn substrate. Sn oxides are formed on the surface of the Sn plating. The formation of these is a root cause of the interface debonding.

The Effect of Tension Band Wiring in the Treatment of the Olecranon Fracture (주두골(肘頭骨) 골절치료(骨折治療)에 있어 Tension Band Wiring의 효과)

  • Ihin, Joo-Chul;Ahn, Jong-Chul;Kim, Sae-Dong;Ahn, Myun-Whan;Seo, Jae-Sung
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.59-63
    • /
    • 1985
  • Treatment of olecranon fractures by prolonged immobilization often results in limited elbow motion. With the use of tension band wiring, anatomical reduction was obtainable, and only a short period of immobilization was needed. We reviewed the cases of 17 patients who underwent surgical treatment of the olecranon fracture. All patients were treated by tension band wiring. In the over-all series, we were able to obtain 53 per cent excellent, 30 per cent good, and 17 per cent fair results.

  • PDF

A Study on the Wiring Plan Considering Construction and Frame Performance Degradation of BIPV System (BIPV시스템 시공 및 프레임 성능저하를 고려한 배선처리방안 제시에 관한 연구)

  • Oh, Min-Seok;Kim, Gi-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.4
    • /
    • pp.33-42
    • /
    • 2018
  • In the application of the BIPV system, it is expected that the workability is lowered due to the difficulty in securing the space for wiring in the frame and the performance of the frame due to the wiring hole processing is lowered. Therefore, In this study, we propose a method to improve the wiring of the inner space of the BIPV frame, and through the simulation evaluation process, the thermal and condensation performance are secured by complementing the problems caused by the hole machining, and the time and effort required for BIPV construction are reduced. For this purpose, a wiring treatment method using a flange insertion tube was proposed, and the thermal and condensation performance was evaluated through simulation analysis.

Validation on Usability of Time Domain Reflectometer for Identifying Defected Aircraft Wiring (항공기 배선 결함 식별을 위한 TDR(시간영역 반사계) 활용 적합성)

  • Kim, Su-Woong;Lee, Jang-Ryong
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.3
    • /
    • pp.205-211
    • /
    • 2020
  • Wiring defect is a major concern for safe aircraft operations. However, troubleshooting process of a wiring defect is very difficult due to extensive and complex wiring system and installed location. Recently, time domain reflectometer (TDR) equipment that enables effective defected wiring troubleshooting has been introduced. Unfortunately, TDRs have not practically adopted by most of airlines' maintenance departments because the effectiveness and usefulness of TDRs have not been verified. This study was conducted to verify if TDRs can identify the location and type of defected aircraft wiring, and whether they can be applied for troubleshooting purposes. Experimental plan was established by using various wires and connections applied to actual aircraft and the observed results were compared with the TDR operation guide. The usability of the TDR in actual aircraft wiring defect detection may be acceptable as the experimental results showed similar results to the TDR operation guide.