• 제목/요약/키워드: wire localization

검색결과 23건 처리시간 0.027초

Applicability of Radioguided Occult Lesion Localization for Non-Palpable Benign Breast Lesions, Comparison with Wire Localization, a Clinical Trial

  • Alikhassi, Afsaneh;Saeed, Farzanefar;Abbasi, Mehrshad;Omranipour, Ramesh;Mahmoodzadeh, Habibollah;Najafi, Massoome;Gity, Masoumeh;Kheradmand, Ali
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권7호
    • /
    • pp.3185-3190
    • /
    • 2016
  • Background: This study was designed to compare radioguided versus routine wire localization of nonpalpable non-malignant breast lesions in terms of efficacy for complete excision, ease of use, time saving, and cosmetic outcome. Materials and Methods: Patients with non-palpable breast masses and non-malignant core biopsy results who were candidates for complete surgical lumpectomy were enrolled and randomly assigned to radioguided or wire localization groups. Radiologic, surgical, and pathologic data were collected and analyzed to determine the difficulty and duration of each procedure, ease of use, accuracy, and cosmetic outcomes. Results: This prospective randomized study included 60 patients, randomly divided into wire guided localization (WGL) or radioguided occult lesion localization (ROLL) groups. The mean duration of localization under ultrasound guidance was shorter in the ROLL group (14.4 min) than in the WGL group (16.5 min) (p<0.001). The ROLL method was significantly easier for radiologists (p=0.0001). The mean duration of the surgical procedure was 22.6 min (${\pm}10.3min$) for ROLL and 23.6 min (${\pm}9.6min$) for WGL (p=0.6), a non-significant difference. Radiography of the surgical specimens showed 100% lesion excision with clear margins, as proved by pathologic examination, with both techniques. The surgical specimens were slightly heavier in the ROLL group, but the difference was not significant (p=0.06). Conclusions: The ROLL technique provides effective, fast, and simple localization and excision of non-palpable non-malignant breast lesions.

MRI-guided Wire Localization Open Biopsy is Safe and Effective for Suspicious Cancer on Breast MRI

  • Wang, Hai-Yi;Zhao, Yu-Nian;Wu, Jian-Zhong;Wang, Zheng;Tang, Jing-Hai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권5호
    • /
    • pp.1715-1718
    • /
    • 2015
  • Background: Magnetic resonance imaging of breast, reported to be a high sensitivity of 94% to 100%, is the most sensitive method for detection of breast cancer. The purpose of this study was to investigate our clinical experience in MRI-guided breast lesion wire localization in Chinese women. Materials and Methods: A total of 44 patients with 46 lesions undergoing MRI-guided breast lesion localization were prospectively entered into this study between November 2013 and September 2014. Samples were collected using a 1.5-T magnet with a special MR biopsy positioning frame device. We evaluated clinical lesion characteristics on pre-biopsy MRI, pathologic results, and dynamic curve type baseline analysis. Results: Of the total of 46 wire localization excision biopsied lesions carried out in 44 female patients, pathology revealed fourteen malignancies (14/46, 30.4%) and thirty-two benign lesions (32/46, 69.6%). All lesions were successfully localized followed by excision biopsy and assessed for morphologic features highly suggestive of malignancy according to the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) category of MRI (C4a=18, C4b=17, C4c=8,C5=3). Of 46 lesions, 37 were masses and 9 were non-mass enhancement lesions. Thirty-two lesions showed a continuous kinetics curve, 11 were plateau and 3 were washout. Conclusions: Our study showed success in MRI-guided breast lesion wire localization with a satisfactory cancer diagnosis rate of 30.4%. MRI-guided wire localization breast lesion open biopsy is a safe and effective tool for the workup of suspicious lesions seen on breast MRI alone without major complications. This may contribute to increasing the diagnosis rate of early breast cancer and improve the prognosis in Chinese women.

폐실질 내에 위치한 소결질 및 간유리 병변에서 흉부컴퓨터단층촬영 유도하에 Hook Wire를 이용한 위치 선정 후 시행한 흉강경 폐절제술의 유용성 (Computed Tomography-guided Localization with a Hook-wire Followed by Video-assisted Thoracic Surgery for Small Intrapulmonary and Ground Glass Opacity Lesions)

  • 강필제;김용희;박승일;김동관;송재우;도경현
    • Journal of Chest Surgery
    • /
    • 제42권5호
    • /
    • pp.624-629
    • /
    • 2009
  • 배경: 패실질 내에 위치한 소결절 및 간유리 병변은 깊이나 크기에 따라서 조직학적 진단이 기존의 방법으로는 어려운 경우가 있다. 이에 연구자는 흉부 전산화 단층 촬영 소견에서 흉강경을 통한 육안 확인이 어려울 것으로 예상되거나 경피 세침 흡인생검술이 부적절하였던 폐실질 내에 위치한 소결절 및 간유리 병변에서 수슬 전에 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정(CT-guided localization with hook wire)을 시행한 후 흉강경 폐절제술을 시행하였고, 그 결과를 보고 하고자 한다. 대상 및 방법: 2005년 8월부터 2008년 3월까지 흉부 전산화 단층 촬영 소견에서 폐실질내에 위치한 소결절 및 간유리 병변을 보인 18명 환자(남자 13명, 나이 중앙값 56세)를 대상으로 수술 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정을 시행한 후 흉강경 폐절제술을 시행하였다. Hook wire 위치의 정확도, 개흉술 전환 정도, 수술 시간, 수술 후 합병증, 폐병변의 조직학적 진단의 정확성 등을 분석하였다. 결과: 18명의 환자가 18개의 폐실질 내에 위치한 소결절 및 간유리 병변에 대해 흉강경 폐절제술을 받았다. 수술 전 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정은 전례에서 성공적으로 시행되었으나, 흉강경 소견에서 wire가 이탈된 경우가 1예 있었다. 수술 전 CT에서 폐 병변 크기의 중앙값은 8 mm ($3{\sim}15\;mm$)였고, 내장 흉막에서 폐병변까지 깊이의 중앙값은 5.5 mm ($1{\sim}30\;mm$)였다. 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정 후 마취 시작까지 걸린 대기 시간의 중앙값은 34.5분($10{\sim}226$분)이었다. 폐병변에 대한 흉강경 폐절제술의 수술 시간은 43.5분($26{\sim}83$분)이었다. 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정과 관련된 합병증으로 2예에서 기흉이 발생하였으나, 임상적으로 유의한 증상은 없었다. 폐병변의 절제 단면은 모든 경우에서 이상 소견이 없었으며, 조직학적 진단은 원발성 폐암 8예, 전이성 폐암 3예, 비특이적 염증성 소견 3예, 폐내 림프절 2예, 기타 2예 등이었으며 조직학적 진단을 하지 못한 경우는 얼었다. 결론: 폐실질 내에 위치한 소결절 및 간유리 병변의 조직학적 진단을 위하여 시행한 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정 후 시행한 흉강경 폐절제술은, 낮은 합병증 발생률, 짧은 수술 시간 및 정확한 조직학적 진단율을 보였다. 따라서 경피 세침 흡인생검술로 정확한 진단이 어렵거나 흉강경을 통한 육안 확인이 불가능한 폐실질 내의 소결절 및 간유리 병변을 조직학적으로 진단하기 위하여 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용하여 위치를 선정한 후 흉강경 폐절제술을 시행하는 것은 매우 효과적이라고 생각한다.

시간-주파수 영역 반사파 계측법 기반 XLPE 전력 케이블의 중성선 결함 위치 측정 연구 (Detection and Localization of Neutral Wire Defect of XLPE Power Cable Based on The Time-Frequency Domain Reflectometry)

  • 이춘구;곽기석;윤태성;박진배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1790-1791
    • /
    • 2011
  • In this paper, the diagnosis system for detecting and localizing the neutral wire defect in an energized XLPE power cable is proposed. The neutral wire defect is detectd and localized by the time-frequency domain reflectometry. To extract the reflected signal from the neutral wire defect, the adaptive RLS filtering is introduced. To verify the proposed method, the experiments for detecting and localizing neutral wire defect in active XLPE power cable is conducted.

  • PDF

저탄소강 선재 압연의 주름성 결함 (Wrinkle Defect of Low Carbon Steel in Wire Rod Rolling)

  • 김학영;권혁철;변상민;박해두;임용택
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 제5회 압연심포지엄 신 시장 개척을 위한 압연기술
    • /
    • pp.307-316
    • /
    • 2004
  • This study examined the cause of the wrinkle defect which is frequently encountered in wire rod rolling of low carbon steel$(C0.08\~0.13wt.\%)$. Even a small defect on the surface of rolled bars can easily develop into fatal cracks during cold heading process of low carbon steel, and it is therefore necessary to minimize inherent defects on the surface of hot rolled bars. Hot rolling process of low carbon steel was analyzed to identify the cause of the wrinkle defect in conjunction with FE analysis. The integrated analysis revealed that the wrinkle defect initiated in the first stage of rolling, and it was at the billet edge where severe deformation and drastic temperature drop were present. To elucidate the micro-mechanical mechanism of the wrinkle defect, hot compression tests were carried out at various temperatures and strain rates using Gleeble-3800. The surface profile of the each other compressed specimens was compared, and rough surface lines were observed at relatively low temperatures. Those surface defects can develop into wrinkles during multi-pass rolling. To control the wrinkle defect in rolling, it is necessary to design an adequate caliber which can minimize the loss of ductility, and thereby prevent flow localization. To use the result of this study fur other steels, the quantitative measure of the wrinkle defect and flow localization parameter should be proposed.

  • PDF

기존 케틀 분석 및 가열 시스템 연구를 통한 16oz 팝퍼 케틀 국산화 기술 개발 (Localization Technology Development of 16oz Popper Kettle through Existing Kettle Analysis and Heating System Study)

  • 이정훈;김경철;오영섭;유범상
    • 한국산학기술학회논문지
    • /
    • 제16권11호
    • /
    • pp.7773-7780
    • /
    • 2015
  • 팝퍼 케틀의 국산화 개발을 위하여 기존 케틀을 분석하고, 열선 배치에 따른 열전달 해석을 통하여 케틀 국산화 개발을 위한 연구를 수행하였다. 케틀 재료 분석을 위한 시편을 제작하고 Polishing 및 Etching을 수행하였다. SEM을 이용하여 시편의 표면을 관찰하여 페라이트 퍼얼라이트 재질을 디프 드로잉 방식으로 제작하였음을 파악하였다. 도금층 재질 및 두께 분석을 통해 Ni(16%)도금이 $16{\sim}49{\mu}m$임을 파악하였다. 또한 열선 배치에 따른 열전달 특성을 파악하고, 최적 열선 시스템을 개발하였다. 케틀의 장시간 작업 시간 중에 발생하는 케틀 과열 시 작동을 중지하는 제어 시스템을 제작하였다. 케틀 개발 이후 성능 평가를 수행하여 부피팽창률에 대한 평가 규격 KS G3602를 만족하였다.

Wire-guided Localization Biopsy to Determine Surgical Margin Status in Patients with Non-palpable Suspicious Breast Lesions

  • Dogan, Lutfi;Gulcelik, M. Ali;Yuksel, Murat;Uyar, Osman;Reis, Erhan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권10호
    • /
    • pp.4989-4992
    • /
    • 2012
  • Purpose: Guide-wire localization (GWL) has been a standard technique for many years. Excision of nonpalpable malignant breast lesions with clear surgical margins reduces the risk of undergoing re-excision. The objective of the present study was to evaluate the efficacy of GWL biopsy for assessing surgical margins. Methods: This retrospective study concerned 53 patients who underwent GWL biopsy for non-palpable breast lesions and breast carcinoma diagnosed by histological examination. Age of the patients, tumour size, radiographic findings, breast density specifications, specimen volumes, menopausal status and family history of the patients and surgical margin status were recorded. Results: Median age was 53.3 years, median tumour size was 1.5 cm and median specimen volume was $71.5cm^3$. In fifteen patients (28%) DCIS and in 38 patients (72%) invasive ductal carcinoma was diagnosed. There was positive surgical margins in twenty eight (52.8%) patients. The median distance to the nearest surgical margin was 7.2 mm in clear surgical margins. Younger age and denser breast specifications were found as statistically significant factors for surgical margin status. Median age of the patients who had positive margins was 49.4 years where it was 56.9 years in the patients with negative margins (p=0.04). 79% of the patients with positive margins had type 3-4 pattern breast density according to BIRADS classification as compared to 48% in the patients who had negative margins (p=0.03). Some 38 patients who had positive or close surgical margins received re-excision (72%). Conclusion: Positive margin rates may be higher because of inherent biological differences and diffuse growth patterns in younger patients. There are also technical difficulties that are relevant to denser fibroglandular tissue in placing hooked wire. High re-excision rates must be taken into consideration while performing GWL biopsy in non-palpable breast lesions.

Hydrocarbon Mist 기/액 분리를 위한 Wire-Mesh Type 시스템 국산화 기술개발 (The localization technical development of Wire-Mesh Type system for Hydrocarbon Mist Gas/Liquid separation)

  • 강성진;박치균;길성재;이만식
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 추계학술논문집 1부
    • /
    • pp.349-352
    • /
    • 2011
  • 본 연구를 통해 개발하고자 하는 Wire-Mesh Type Mist Eliminator는 탄화수소(Hydrocarbon)를 취급하는 석유화학 공정 내에서 Vapor 중에 존재하는 $10{\mu}m$ 이하크기의 미세한 액체 Mist를 분리하는데 사용되는 화학 공정플랜트 요소부품이다. 석유화학 공정에서 발생되는 $5{\mu}m$이하의 크기를 가지는 액체 Mist를 제거하기 위해서는 Stainless와 Polypropylene 재질이 혼합된 새로운 WMT Mist Eliminator 국산화 제품개발 시급하다. 실험을 통해 확보한 인자를 바탕으로 제작된 시제품의 분석결과 석유 화학공정에 이용이 가능한 것을 확인하고 성능이 우수함을 알 수 있었다.

  • PDF

유방촬영술 유도하 중재 시술 (Mammography-Guided Interventional Procedure)

  • 최우정;김학희
    • 대한영상의학회지
    • /
    • 제84권2호
    • /
    • pp.320-331
    • /
    • 2023
  • 유방촬영술을 이용한 유방암 검진은 표준 영상 방법이다. 초음파에서 보이지 않고 유방촬영술이나 디지털 유방 토모신테시스에서만 보이는 의심스러운 석회화, 구조 왜곡의 조직학적 진단을 위해 입체정위생검과 유방촬영술 유도하 수술 전 위치결정술을 시행한다. 본 종설에서는 입체정위생검의 적응증 및 비적응증, 방법, 입체정위생검 후 클립 삽입과 디지털 유방 토모신테시스 유도하 입체정위생검에 대해 알아보고자 한다. 또한, 유방촬영술 유도하 수술 전 위치결정술을 침위치결정술과 비침위치결정술로 나누어 소개하고자 한다.

퍼지와 비례 제어를 이용한 지게차 AGV의 주행제어 (Fuzzy and Proportional Controls for Driving Control of Forklift AGV)

  • 김정민;박정제;전태룡;김성신
    • 한국지능시스템학회논문지
    • /
    • 제19권5호
    • /
    • pp.699-705
    • /
    • 2009
  • 본 논문은 지게차 AGV(autonomous ground vehicle)의 자율주행을 위한 제어 방법에 관한 연구이다. 기존에 개발된 지게차 AGV의 위치측정 방법으로는 자기-자이로 유도(magnet-gyro guidance) 방식과 유선 유도(wire guidance) 방법이 있지만, 유지보수에 대한 지속적인 노력과 비용문제가 있으며, 작업 환경의 변화에 따라 작업 환경을 재구성해야하는 단점이 있다. 따라서 본 논문에서는 외란에 강인하고 작업 환경 및 작업 내용의 변경에 유연한 시스템을 구축하기 위해 레이저 내비게이션 센서와 엔코더, 자이로 센서의 센서융합을 통한 위치측정 시스템을 개발하였다. 또한 팔레트를 하역 운송해야하는 지게차 AGV의 주행제어를 위해 팔레트와 지게차 AGV 사이의 거리 차와 각도 차를 바탕으로 퍼지 제어 및 비례 제어를 이용한 주행제어기를 설계하였다. 본 연구에서 제안한 지게차 AGV를 위한 제어 시스템의 성능 분석을 위해 물류 운송작업이 가능한 작업공간에서 동일한 하역 작업을 10회 반복 하였다. 그 결과, 시뮬레이션에 의해 생성된 경로와 실제 주행경로의 최대 평균 오차가 87.77mm를 가짐을 확인하였다.