Alikhassi, Afsaneh;Saeed, Farzanefar;Abbasi, Mehrshad;Omranipour, Ramesh;Mahmoodzadeh, Habibollah;Najafi, Massoome;Gity, Masoumeh;Kheradmand, Ali
Asian Pacific Journal of Cancer Prevention
/
제17권7호
/
pp.3185-3190
/
2016
Background: This study was designed to compare radioguided versus routine wire localization of nonpalpable non-malignant breast lesions in terms of efficacy for complete excision, ease of use, time saving, and cosmetic outcome. Materials and Methods: Patients with non-palpable breast masses and non-malignant core biopsy results who were candidates for complete surgical lumpectomy were enrolled and randomly assigned to radioguided or wire localization groups. Radiologic, surgical, and pathologic data were collected and analyzed to determine the difficulty and duration of each procedure, ease of use, accuracy, and cosmetic outcomes. Results: This prospective randomized study included 60 patients, randomly divided into wire guided localization (WGL) or radioguided occult lesion localization (ROLL) groups. The mean duration of localization under ultrasound guidance was shorter in the ROLL group (14.4 min) than in the WGL group (16.5 min) (p<0.001). The ROLL method was significantly easier for radiologists (p=0.0001). The mean duration of the surgical procedure was 22.6 min (${\pm}10.3min$) for ROLL and 23.6 min (${\pm}9.6min$) for WGL (p=0.6), a non-significant difference. Radiography of the surgical specimens showed 100% lesion excision with clear margins, as proved by pathologic examination, with both techniques. The surgical specimens were slightly heavier in the ROLL group, but the difference was not significant (p=0.06). Conclusions: The ROLL technique provides effective, fast, and simple localization and excision of non-palpable non-malignant breast lesions.
Background: Magnetic resonance imaging of breast, reported to be a high sensitivity of 94% to 100%, is the most sensitive method for detection of breast cancer. The purpose of this study was to investigate our clinical experience in MRI-guided breast lesion wire localization in Chinese women. Materials and Methods: A total of 44 patients with 46 lesions undergoing MRI-guided breast lesion localization were prospectively entered into this study between November 2013 and September 2014. Samples were collected using a 1.5-T magnet with a special MR biopsy positioning frame device. We evaluated clinical lesion characteristics on pre-biopsy MRI, pathologic results, and dynamic curve type baseline analysis. Results: Of the total of 46 wire localization excision biopsied lesions carried out in 44 female patients, pathology revealed fourteen malignancies (14/46, 30.4%) and thirty-two benign lesions (32/46, 69.6%). All lesions were successfully localized followed by excision biopsy and assessed for morphologic features highly suggestive of malignancy according to the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) category of MRI (C4a=18, C4b=17, C4c=8,C5=3). Of 46 lesions, 37 were masses and 9 were non-mass enhancement lesions. Thirty-two lesions showed a continuous kinetics curve, 11 were plateau and 3 were washout. Conclusions: Our study showed success in MRI-guided breast lesion wire localization with a satisfactory cancer diagnosis rate of 30.4%. MRI-guided wire localization breast lesion open biopsy is a safe and effective tool for the workup of suspicious lesions seen on breast MRI alone without major complications. This may contribute to increasing the diagnosis rate of early breast cancer and improve the prognosis in Chinese women.
배경: 패실질 내에 위치한 소결절 및 간유리 병변은 깊이나 크기에 따라서 조직학적 진단이 기존의 방법으로는 어려운 경우가 있다. 이에 연구자는 흉부 전산화 단층 촬영 소견에서 흉강경을 통한 육안 확인이 어려울 것으로 예상되거나 경피 세침 흡인생검술이 부적절하였던 폐실질 내에 위치한 소결절 및 간유리 병변에서 수슬 전에 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정(CT-guided localization with hook wire)을 시행한 후 흉강경 폐절제술을 시행하였고, 그 결과를 보고 하고자 한다. 대상 및 방법: 2005년 8월부터 2008년 3월까지 흉부 전산화 단층 촬영 소견에서 폐실질내에 위치한 소결절 및 간유리 병변을 보인 18명 환자(남자 13명, 나이 중앙값 56세)를 대상으로 수술 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정을 시행한 후 흉강경 폐절제술을 시행하였다. Hook wire 위치의 정확도, 개흉술 전환 정도, 수술 시간, 수술 후 합병증, 폐병변의 조직학적 진단의 정확성 등을 분석하였다. 결과: 18명의 환자가 18개의 폐실질 내에 위치한 소결절 및 간유리 병변에 대해 흉강경 폐절제술을 받았다. 수술 전 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정은 전례에서 성공적으로 시행되었으나, 흉강경 소견에서 wire가 이탈된 경우가 1예 있었다. 수술 전 CT에서 폐 병변 크기의 중앙값은 8 mm ($3{\sim}15\;mm$)였고, 내장 흉막에서 폐병변까지 깊이의 중앙값은 5.5 mm ($1{\sim}30\;mm$)였다. 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정 후 마취 시작까지 걸린 대기 시간의 중앙값은 34.5분($10{\sim}226$분)이었다. 폐병변에 대한 흉강경 폐절제술의 수술 시간은 43.5분($26{\sim}83$분)이었다. 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정과 관련된 합병증으로 2예에서 기흉이 발생하였으나, 임상적으로 유의한 증상은 없었다. 폐병변의 절제 단면은 모든 경우에서 이상 소견이 없었으며, 조직학적 진단은 원발성 폐암 8예, 전이성 폐암 3예, 비특이적 염증성 소견 3예, 폐내 림프절 2예, 기타 2예 등이었으며 조직학적 진단을 하지 못한 경우는 얼었다. 결론: 폐실질 내에 위치한 소결절 및 간유리 병변의 조직학적 진단을 위하여 시행한 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용한 위치 선정 후 시행한 흉강경 폐절제술은, 낮은 합병증 발생률, 짧은 수술 시간 및 정확한 조직학적 진단율을 보였다. 따라서 경피 세침 흡인생검술로 정확한 진단이 어렵거나 흉강경을 통한 육안 확인이 불가능한 폐실질 내의 소결절 및 간유리 병변을 조직학적으로 진단하기 위하여 흉부컴퓨터단층촬영 유도하에 Hook wire를 이용하여 위치를 선정한 후 흉강경 폐절제술을 시행하는 것은 매우 효과적이라고 생각한다.
In this paper, the diagnosis system for detecting and localizing the neutral wire defect in an energized XLPE power cable is proposed. The neutral wire defect is detectd and localized by the time-frequency domain reflectometry. To extract the reflected signal from the neutral wire defect, the adaptive RLS filtering is introduced. To verify the proposed method, the experiments for detecting and localizing neutral wire defect in active XLPE power cable is conducted.
This study examined the cause of the wrinkle defect which is frequently encountered in wire rod rolling of low carbon steel$(C0.08\~0.13wt.\%)$. Even a small defect on the surface of rolled bars can easily develop into fatal cracks during cold heading process of low carbon steel, and it is therefore necessary to minimize inherent defects on the surface of hot rolled bars. Hot rolling process of low carbon steel was analyzed to identify the cause of the wrinkle defect in conjunction with FE analysis. The integrated analysis revealed that the wrinkle defect initiated in the first stage of rolling, and it was at the billet edge where severe deformation and drastic temperature drop were present. To elucidate the micro-mechanical mechanism of the wrinkle defect, hot compression tests were carried out at various temperatures and strain rates using Gleeble-3800. The surface profile of the each other compressed specimens was compared, and rough surface lines were observed at relatively low temperatures. Those surface defects can develop into wrinkles during multi-pass rolling. To control the wrinkle defect in rolling, it is necessary to design an adequate caliber which can minimize the loss of ductility, and thereby prevent flow localization. To use the result of this study fur other steels, the quantitative measure of the wrinkle defect and flow localization parameter should be proposed.
팝퍼 케틀의 국산화 개발을 위하여 기존 케틀을 분석하고, 열선 배치에 따른 열전달 해석을 통하여 케틀 국산화 개발을 위한 연구를 수행하였다. 케틀 재료 분석을 위한 시편을 제작하고 Polishing 및 Etching을 수행하였다. SEM을 이용하여 시편의 표면을 관찰하여 페라이트 퍼얼라이트 재질을 디프 드로잉 방식으로 제작하였음을 파악하였다. 도금층 재질 및 두께 분석을 통해 Ni(16%)도금이 $16{\sim}49{\mu}m$임을 파악하였다. 또한 열선 배치에 따른 열전달 특성을 파악하고, 최적 열선 시스템을 개발하였다. 케틀의 장시간 작업 시간 중에 발생하는 케틀 과열 시 작동을 중지하는 제어 시스템을 제작하였다. 케틀 개발 이후 성능 평가를 수행하여 부피팽창률에 대한 평가 규격 KS G3602를 만족하였다.
Dogan, Lutfi;Gulcelik, M. Ali;Yuksel, Murat;Uyar, Osman;Reis, Erhan
Asian Pacific Journal of Cancer Prevention
/
제13권10호
/
pp.4989-4992
/
2012
Purpose: Guide-wire localization (GWL) has been a standard technique for many years. Excision of nonpalpable malignant breast lesions with clear surgical margins reduces the risk of undergoing re-excision. The objective of the present study was to evaluate the efficacy of GWL biopsy for assessing surgical margins. Methods: This retrospective study concerned 53 patients who underwent GWL biopsy for non-palpable breast lesions and breast carcinoma diagnosed by histological examination. Age of the patients, tumour size, radiographic findings, breast density specifications, specimen volumes, menopausal status and family history of the patients and surgical margin status were recorded. Results: Median age was 53.3 years, median tumour size was 1.5 cm and median specimen volume was $71.5cm^3$. In fifteen patients (28%) DCIS and in 38 patients (72%) invasive ductal carcinoma was diagnosed. There was positive surgical margins in twenty eight (52.8%) patients. The median distance to the nearest surgical margin was 7.2 mm in clear surgical margins. Younger age and denser breast specifications were found as statistically significant factors for surgical margin status. Median age of the patients who had positive margins was 49.4 years where it was 56.9 years in the patients with negative margins (p=0.04). 79% of the patients with positive margins had type 3-4 pattern breast density according to BIRADS classification as compared to 48% in the patients who had negative margins (p=0.03). Some 38 patients who had positive or close surgical margins received re-excision (72%). Conclusion: Positive margin rates may be higher because of inherent biological differences and diffuse growth patterns in younger patients. There are also technical difficulties that are relevant to denser fibroglandular tissue in placing hooked wire. High re-excision rates must be taken into consideration while performing GWL biopsy in non-palpable breast lesions.
본 연구를 통해 개발하고자 하는 Wire-Mesh Type Mist Eliminator는 탄화수소(Hydrocarbon)를 취급하는 석유화학 공정 내에서 Vapor 중에 존재하는 $10{\mu}m$ 이하크기의 미세한 액체 Mist를 분리하는데 사용되는 화학 공정플랜트 요소부품이다. 석유화학 공정에서 발생되는 $5{\mu}m$이하의 크기를 가지는 액체 Mist를 제거하기 위해서는 Stainless와 Polypropylene 재질이 혼합된 새로운 WMT Mist Eliminator 국산화 제품개발 시급하다. 실험을 통해 확보한 인자를 바탕으로 제작된 시제품의 분석결과 석유 화학공정에 이용이 가능한 것을 확인하고 성능이 우수함을 알 수 있었다.
유방촬영술을 이용한 유방암 검진은 표준 영상 방법이다. 초음파에서 보이지 않고 유방촬영술이나 디지털 유방 토모신테시스에서만 보이는 의심스러운 석회화, 구조 왜곡의 조직학적 진단을 위해 입체정위생검과 유방촬영술 유도하 수술 전 위치결정술을 시행한다. 본 종설에서는 입체정위생검의 적응증 및 비적응증, 방법, 입체정위생검 후 클립 삽입과 디지털 유방 토모신테시스 유도하 입체정위생검에 대해 알아보고자 한다. 또한, 유방촬영술 유도하 수술 전 위치결정술을 침위치결정술과 비침위치결정술로 나누어 소개하고자 한다.
본 논문은 지게차 AGV(autonomous ground vehicle)의 자율주행을 위한 제어 방법에 관한 연구이다. 기존에 개발된 지게차 AGV의 위치측정 방법으로는 자기-자이로 유도(magnet-gyro guidance) 방식과 유선 유도(wire guidance) 방법이 있지만, 유지보수에 대한 지속적인 노력과 비용문제가 있으며, 작업 환경의 변화에 따라 작업 환경을 재구성해야하는 단점이 있다. 따라서 본 논문에서는 외란에 강인하고 작업 환경 및 작업 내용의 변경에 유연한 시스템을 구축하기 위해 레이저 내비게이션 센서와 엔코더, 자이로 센서의 센서융합을 통한 위치측정 시스템을 개발하였다. 또한 팔레트를 하역 운송해야하는 지게차 AGV의 주행제어를 위해 팔레트와 지게차 AGV 사이의 거리 차와 각도 차를 바탕으로 퍼지 제어 및 비례 제어를 이용한 주행제어기를 설계하였다. 본 연구에서 제안한 지게차 AGV를 위한 제어 시스템의 성능 분석을 위해 물류 운송작업이 가능한 작업공간에서 동일한 하역 작업을 10회 반복 하였다. 그 결과, 시뮬레이션에 의해 생성된 경로와 실제 주행경로의 최대 평균 오차가 87.77mm를 가짐을 확인하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.