• 제목/요약/키워드: wire breakage

검색결과 49건 처리시간 0.02초

Nb_{3}$Sn 초전도 선재용 대형 빌렛 제조 및 가공 조건 연구 (Fabrication of Nb_{3}$Sn superconducting wire from large billet stage)

  • 하동우;오상수;하홍수;이남진;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.9-11
    • /
    • 2000
  • A key technology for achieving commercial Nb_{3}$Sn superconducting wires may be driven from fabrication process of big-scale billets. There was no breakage in the strand that was constituted with annealed sub-element. It was need that billet had to treat HIP because of remove of voids and good contact between Cu and Nb filaments. Ta wound sheet was better than Ta tube for barrier in the strand.

  • PDF

유도전력전송방식의 이식형 기능적 전기자극 (Implantable Functional Electrical Stimulation with Inductive Power and Data Transmission System)

  • 이준하
    • Journal of Yeungnam Medical Science
    • /
    • 제24권2호
    • /
    • pp.97-106
    • /
    • 2007
  • Functional electrical stimulation (FES) has developed over the last 35 years to become a scientifically, technologically and clinically recognized field of interest in clinical medicine. FES has been applied to locomotion, grasping, ventilation, incontinence, and decubitus healing. However, all of these achievements illustrate the initial applications of FES; its true potential has not yet been realized. Recently, FES systems, which are miniaturized stimulation devices, have been utilized in the clinical setting. However, because the stimulating electrodes of the current FES devices are percutaneous electrodes, which are susceptible to wire breakage, and skin infection an implantable FES stimulating electrode has been introduced in the U.S. and Japan. In the present study, an external power supply method using radio frequency (RF) coupling and data transmission was developed for the control of the implantable FES device. In addition, we review the current understanding of FES devices and their application in clinical medicine.

  • PDF

축추-환추간 경관절 나사못 고정술 치료의 결과 및 합병증 (The Results and Complications of the C1-C2 Transarticular Screw Fixation Methods)

  • 최준웅;윤승환;박형천;박현선;김은영;하윤
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권3호
    • /
    • pp.201-206
    • /
    • 2005
  • Objective: To evaluate the accuracy and safety of C1-C2 transarticular screw insertion, we retrospectively review surgical records and postoperative radiological findings. Methods: From January 2001 to October 2003, the C1-C2 transarticular screw fixation and posterior wiring with iliac bone grafts was performed in 16 patients. 6 patients had rheumatoid arthritis which caused cervical instability, 3 patients had os odontoideum, 3 patients had type 2 odontoid process fracture, 3 patients had traumatic transverse ligament injury and 1 patients who had been managed with C1-C2 wire fixation had psoriatic arthritis. Results: Osseous fusion was documented in 15 patients(93.8%). Only one patient was recorded screw loosening because of postoperative infection. One patient had only one screw placed because of abnormal anatomical structure, one patients was breakage of a Kirschner wire, and one screw was medial location to lateral mass of C1, but clinical results was excellent and radiological instability was not noted. Conclusion: The author's experience demonstrates that C1-C2 transarticular screw fixation with wired bone graft is a safe procedure with higher fusion rate but precaution is needed to avoid the neural damage, vertebral artery injury, and hardware failure.

FCC계 고엔트로피 합금의 냉간 인발 유한요소해석 및 실험적 검증 (Finite Element Analysis and Experimental Verification for the Cold-drawing of a FCC-based High Entropy Alloy)

  • 조한솔;배성준;나영상;김정한;이동근;이광석
    • 소성∙가공
    • /
    • 제29권3호
    • /
    • pp.163-171
    • /
    • 2020
  • We present a multi-step cold drawing for a non-equiatomic Co10Cr15Fe25Mn10Ni30V10 high entropy alloy (HEA) with a simple face-centered cubic (FCC) crystal structure. The distribution of strain in the cold-drawn Co10Cr15Fe25Mn10Ni30V10 HEA wires was analyzed by the finite element method (FEM). The effective strain was expected to be higher as it was closer to the surface of the wire. However, the reverse shear strain acted to cause a transition in the shear strain behavior. The critical effective strain at which the shear strain transition behavior is completely shifted was predicted to be 4.75. Severely cold-drawn Co10Cr15Fe25Mn10Ni30V10 HEA wires up to 96% of the maximum cross-sectional reduction ratio were successfully manufactured without breakage. With the assistance of electron back-scattering diffraction and transmission electron microscope analyses, the abundant deformation twins were found in the region of high effective strain, which is a major strengthening mechanism for the cold-drawn Co10Cr15Fe25Mn10Ni30V10 HEA wire.

흡수성 봉합사를 이용한 무지외반증 Akin 절골술 (Fixation with Absorbable Suture Material in Akin Osteotomy)

  • 송무호;김부환;안성준;유성호;이두재
    • 대한족부족관절학회지
    • /
    • 제15권3호
    • /
    • pp.149-152
    • /
    • 2011
  • Purpose: The Akin osteotomy which is a closing wedge osteotomy of the proximal phalanx widely used for the correction of hallux valgus has several methods of fixation. we tried to report the effects of the fixation using an absorbable suture material during the Akin osteotomy for the hallux valgus. Materials and Methods: This study was based on 448 cases of 346 patients who were able for follow-up more than 12 months among the patients who had an Akin osteotomy together with the surgery of hallux valgus between March of 2006 and May of 2010. Absorbable suture material had been used in all cases. Radiologically displacement and union of osteotomy site were observed after the surgery, and clinically postoperative complication such as skin irritation, pain and satisfaction were investigated. Results: Radiologically all cases had showed complete union and no case had the loss of an correction due to loss of fixation. Also, any case had no skin irritation due to a knot. Three cases had a medial cortical breakage due to a strong knot, and the initial one case among them had additionally fixed the osteotomy site for four weeks using K-wire, and the remaining two cases had fixed a suture on an articular surface without any fixation of an additional wire. If a medial cortical bone was lost by carrying out an ostectomy due to proximal protrusion of proximal phalanx, three cases could show union through the fixation of suture on an articular surface. Conclusion: This study considers that the fixation of the osteotomy site using an absorbable suture material in an Akin osteotomy was effective method and the advantage of this procedure was unnecessity of the material removal and no skin irritation.

Primary Arthroplasty for Unstable and Failed Intertrochanteric Fractures: Role of Multi-Planar Trochanteric Wiring Technique

  • Javahir A. Pachore;Vikram Indrajit Shah;Sachin Upadhyay;Shrikunj Babulal Patel
    • Hip & pelvis
    • /
    • 제35권2호
    • /
    • pp.108-121
    • /
    • 2023
  • Purpose: The primary objective of the current study is to demonstrate the trochanteric wiring technique. A secondary objective is to evaluate the clinico-radiological outcomes of use of the wiring technique during primary arthroplasty for treatment of unstable and failed intertrochanteric fractures. Materials and Methods: A prospective study including follow-up of 127 patients with unstable and failed intertrochanteric fractures who underwent primary hip arthroplasty using novel multi-planar trochanteric wiring was conducted. The average follow-up period was 17.8±4.7 months. Clinical assessment was performed using the Harris hip score (HHS). Radiographic evaluation was performed for assessment of union of the trochanter and any mechanical failure. P<0.05 was considered statistically significant. Results: At the latest follow-up, the mean HHS showed significant improvement from 79.9±1.8 (at three months) to 91.6±5.1 (P<0.05). In addition, no significant difference in the HHS was observed between male and female patients (P=0.29) and between fresh and failed intertrochanteric fractures (P=0.08). Union was achieved in all cases of fractured trochanter, except one. Wire breakage was observed in three patients. There were five cases of limb length discrepancy, three cases of lurch, and three cases of wire-related bursitis. There were no cases of dislocation or infection. Radiographs showed stable prosthesis in situ with no evidence of subsidence. Conclusion: Use of the proposed wiring technique was helpful in restoring the abductor level arm and multi-planar stability, which enabled better rehabilitation and resulted in excellent clinical and radiological outcomes with minimal risk of mechanical failure.

위식도 역류 실시간 모니터링 마이크로 와이어 pH 전극 개발 (Development of Micro Wired pH Electrode for Real-Time Monitoring for Gastroesophageal Reflux)

  • 김응보;이규진;소상균;정연호;박정호;김남희
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권6호
    • /
    • pp.277-284
    • /
    • 2017
  • This paper presents an implantable pH measurement electrode for wireless gastroesophageal reflux measurement. Usually, gastroesophageal reflux is diagnosed by a catheter-type wire connection between the esophagus and the diagnostic device which brings many side effects such as restriction of daily living, pain, and discomfort in the nasal cavity and pharynx of patients. In order to solve these issues, researchers have been studied a wireless measurement method and a micro-sized pH electrode for human body insertion is necessary. Commercial glass packaged pH meter is formed by a sensing and a reference electrodes in a KCl solution. However, if the glass meter is inserted into the human body, there are risks of leakage of the solution, breakage of the glass package, injury of the body elements. Therefore, the solution should be solidified on the micro-sized noble metal wire which has a characteristic of biocompatible. After solidified wire fabrication, the designed meter was tested for feasibility of measurement and the result was well agreed with pH values of commercial pH meter. Potentials in pH 1 to 12 solution was measured to obtain the sensitivity of the sensor with linearity. And we have designed a simulation of gastroesophageal reflux with symptom frequency, interval, and duration time in pH 2 solution. The proposed sensor has capable to get the same potential for 24 measurements in 3 days, and it has sensed same pH values of 2 for one hour with every 10 minutes. Furthermore, the sensor was survived for 48 hours with reasonable potentials in the acid solution.

내부 확산법으로 제조한 $Nb_{3}$ Sn초전도선의 세선화에 의한 유연성 조사 (Effect of wire diameters on superconducting and mechanical properties of internal tin processed $Nb_{3}$ Sn wires)

  • 하동우;오상수;이남진;하홍수;권영길;류강식;백홍구
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.29-32
    • /
    • 2001
  • Internal tin processed Nb$_3$Sn wires of intermediated worked state of were took from Mitsubishi and fabricated with various diameters ranging from 0.76 mm to 0.2 mm. These specimens were heat-treated at $460^{\circ}C$ for 70 h and at $570^{\circ}C$ for 100h to form bronze and at $700^{\circ}C$ for 100h to form Nb$_3$Sn compound. Bending strain Ic s of the wires were measured with various bending diameters ranging from flat to 76 mm. In order to investigate the sensitivity for strain, small diameters of wires were strain Ic at 6 T, 4.2 K. There were no breakage decrease during cold working to 0.2 mm of diameter and no decrease Jc to the diameter of 0.3 mm. The values of bending strain Ic of 0.2 mm and 0.3 mm diameters of the wires were not decreased at 76 mm of bending diameter.

  • PDF

345kV 송전선로용 자동클램핑 장치형 스페이서 댐퍼 개발 (A development of the 345kV spacer damper with automatic clamping device for transmission line)

  • 안용호;이동일;김태진;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.278-282
    • /
    • 2001
  • The purpose of this study is to introduce a new spacer damper for the bundle transmission lines network. It has the special design, the main characteristics and advantage of this new kind of spacer damper. An Existing spacer damper with bolted clamps, although widely used, is a method of connection with certain disadvantage both as regards assembly on the conductor and in the course of time. Even if tightening torque is correctly applied by using bolt with share head or torque wrench during working time, the aeolian vibration could involve untightening during life time, so the cable can move into the Jaws and wire's breakage appear. To salve this problems, France, Japan and other countries had developed a spacer damper with an automatic system through many years. This new spacer damper is an original automatic clamping device (beltless) which does not require special tool for its installation. This device prevents clamp unlocking problems, ensures a simple installation and ensures a reliable-tightening during life time. Therefore, it is necessary to localize this boltless spacer damper with automate clamping device.

  • PDF

진동형 히트파이프를 이용한 고출력 LED 조명 방열 설계 (High-Power LED Thermal Spreaders Design Using Pulsating Heat Pipe)

  • 장정완;김종수;하수정
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1379-1384
    • /
    • 2009
  • High power light emitting diode(LEDs), a strong candidate for the next generation general illumination applications are of interest. With major advantages of power saving, increased life expectancy and faster response time over traditional incandescent bulb, the LEDs are rapidly taking over many applications such as LCD backlighting, traffic light, automotive lighting, signage, etc. The increased electrical currents used to drive the LEDs have focused more attention on the thermal management because the efficiency and reliability of the solid-state lighting devices strongly depend on successful thermal management. There exist some problems that are caused by heat generation in the LED package, such as wire breakage, yellowing of epoxy resin, lifted chip caused by reflow of thermal paste chip attach and interfacial separation between LED package and silicon resin. The goal of this study is to analyze high power LED thermal properties of using pulsating heat pipe.

  • PDF