• 제목/요약/키워드: windows

검색결과 4,104건 처리시간 0.029초

축소모형주택을 이용한 전통창호의 차음성능에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Performance of Korean Traditional Windows by Using a Scale Model House)

  • 신훈;장길수;송민정
    • 한국주거학회논문집
    • /
    • 제17권5호
    • /
    • pp.47-54
    • /
    • 2006
  • This study aims to evaluate the sound insulation performance of Korean traditional paper(Hanji) windows as a material of environmental friendly building. Six types of traditional windows with 4 types of traditional window positions, were installed in l/2.5 scale model house. And then according to KS F 2235, comparative sound level differences between outdoor and indoor were measured. The main results are as follows; 1) TL(Transmission Loss) of Korean traditional paper windows, which cover one eighth of total balcony window, are ranged from 15 to 19 dB(A) in the living room and from 8 to 11 dB(A) in the balcony space. 2) TL of Korean traditional paper windows, which cover one fourth of total balcony window, are ranged from 10 to 19 dB(A) in the living room and from 8 to 10 dB(A) in the balcony space. 3) TL of Korean traditional windows with one side-one layer paper is ranged from 10 to 21 dB(A) and two side-one layer paper is 15 to 23 dB(A) and two side-two layer paper is 19 to 23 dB(A) respectively.

난방에너지 사용량 분석을 통한 후강화 로이유리 창호의 단열성능 평가 (Thermal performance evaluation of Temperable Low-e glass window through Heating Energy consumption Analysis)

  • 장철용;김정국;안병립;김준섭;한찬훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.200-205
    • /
    • 2012
  • In the high oil price age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating in large percent of whole building loads, and are regarding as the primary target of energy efficiency. In this study, in order to reduce heat loss of buildings, we investigate the thermal performance properties of Temperable Low-e glazing coated Ag membrane that has high electrical conductivity. The Temperable Low-e glazing windows has high insulation and shading properties, and it has strength that can supply various product which consumers want. In order to evaluate thermal performance of temperable windows, we install single low-e windows and double low-e windows in the experimental chamber and analysis the comparison heating energy consumption between single and double Low-e glazing windows. performance evaluation was conducted.

  • PDF

색상 및 적용위치에 따른 DSC 통합창호 디자인 컨셉에 관한 연구 (A Study on the Design Concept of DSC Window by Color and Installation Position)

  • 이기원;이응직
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.91-99
    • /
    • 2014
  • The purpose of the study is to apprehend the preference of occupants to colors and installation locations for DSC combined windows and doors, and suggest a concept to optimize the design and function of windows and doors. A miniature model was made applying green, blue, and red colored DSC windows and doors to survey preference about DSC colors and applied location. And a survey was accomplished to 140 subjects by showing pictures of the model and the result of the survey became the basis for suggesting a concept to design DSC integrated windows and doors. Through the survey, blue color and upper part were chosen as the highest level of satisfaction in the situation of external brightness and residence. On the contrary to this, red color was chosen as the lowest level of preference when applied to both of upper and lower parts of winders and doors. Therefore, it's expected that, if various patterns of texture are developed for blue colored DSC, and installation is arranged based on upper part of windows and doors where lighting condition and comfort are less affected, then, conditions of brightness, view, and residents satisfaction will be equally fulfilled.

현장실험에서 음원의 입사각도에 따른 창의 차음성능 변화 (Variations of the Sound Insulation Performance of the Windows for the Sound Source Angle in the Field Test)

  • 김선우;김기용;이옥균;박현구;송혁
    • 소음진동
    • /
    • 제9권6호
    • /
    • pp.1180-1186
    • /
    • 1999
  • The aim of this study is to investigate the sound insulation performance of windows according to the sound source in the field test. For this purpose, an experiment was performed by KSF 2235(method for field measurements of sound insulation of windows and doors). Based on this code, the sound insulation performance fo the windows was measured for different incident angles of the sound and the effect of incident angle was obtained and discussed. Finally, it was found that the sound insulation performance of the windows was affected by the incident angle of sound source, and the sound insulation rating scale was different for the same window. The main factor changing insulation rating scale is considered to be the sound transmission through the carck of the folding part between the two pieces of wndows. Therefore, when evaluating the sound insulation performance of the windows for the field test, first of all the place of the sound source should be identified and generalized.

  • PDF

창호시스템의 환경성능평가기법 정립에 관한 연구 (A study on the proposal of environmental capacity criterion method for windows system in buildings)

  • 최두성;김은규;조균형
    • 한국태양에너지학회 논문집
    • /
    • 제24권3호
    • /
    • pp.101-109
    • /
    • 2004
  • This research investigates the life-cycle energy consumption of the windows used for the building's exterior cladding, and its environmental potential aspects by utilizing the LCA. The research scope has taken account of the entire life-cycle of the windows from the extraction of raw materials to its disposal, of which given sample building type is an apartment building. Results gained from the LCA of the windows as one of the steps in analysis reflects the current global interest and analysis trend towards the world's environmental issue on all fields of industry including the architectural industry, of which its newly established standards of architectural windows can further promote more environmentally sustainable factor compared to the previous analysis (focused more on energy efficiency assessment of the use stage).

투명 방탄소재용 보로실리케이트 유리의 이온교환 강화 (Strengthening of Borosilicate Glass by Ion Exchange for Lightweight Transparent Bulletproof Windows Materials)

  • 심규인;엄형우;최세영
    • 한국군사과학기술학회지
    • /
    • 제16권4호
    • /
    • pp.507-513
    • /
    • 2013
  • Transparent bulletproof windows play an important role in the munitions industry. The thickness of bulletproof windows including soda-lime silicate(SLS) glass, polyvinyl butyral, poly urethane, main defense(200MD), and safety film was reduced from 40mm to 29mm by adjustment of SLS glass laminated array. Borosilicate glasses generally have lower surface density and more excellent mechanical properties than SLS glass. Borosilicate glass was strengthened by ion exchange in the $KNO_3$ powder. The maximum mechanical properties were observed at $550^{\circ}C$ for 10min. The Vickers hardness, fracture toughness and 3-point bending strength of ion exchanged samples were about $775kg/mm^2$, $1.91MPa{\cdot}m^{1/2}$ and 764MPa each, which are about 27%, 149% and 249% higher than parent borosilicate glass, respectively. The penetration depth of K+ ion at $550^{\circ}C$ for 10min was $59.8{\mu}m$. As a result, the transparent bulletproof windows were predicted to be more lightweight by ion exchange of borosilicate glass. If the SLS glass for bulletproof windows is replaced by ion exchanged borosilicate glass, the bulletproof windows can be expected to be lightweight and thinner.

RTiK과 DPC 제어를 통한 윈도우즈 기반의 검사장비에서 MIL-STD-1553B 통신의 실시간 구현 (Implementation for Real-Time of MIL-STD-1553B Communication in Inspection Equipment Based on Windows with RTiK and DPC Control)

  • 김종진;이상길;이철훈
    • 한국멀티미디어학회논문지
    • /
    • 제24권2호
    • /
    • pp.199-207
    • /
    • 2021
  • It is very important to support real-time on the inspection equipment based on Windows. In particular, in the system using MIL-STD-1553B communication, which is widely used in military weapon systems, real-time is required for inspection equipment that uses mostly platforms based on Windows such as Industrial PCs. However, in order to use a complete real-time operating system such as VxWorks, the purchase cost is expensive and the implementation is complicated on the system, so it is not suitable for inspection equipment that requires simple functions to just check go or no-go. Therefore, in this paper, a Real-Time implanted Kernel(RTiK) in the Windows kernel is implanted in order to improve these defects, and real-time performance is implemented for periodically MIL-STD-1553B communication by Deferred Procedure Call(DPC) of Windows. Also, it was verified that the period of up to 2ms was guaranteed with a RDTSC into the EDX:EAX registers for measuring the periodicity.

플라즈몬 금속 산화물 나노입자를 활용한 차세대 전기변색 소자 개발 동향 (Recent Progress of Developing Next-Generation Electrochromic Windows from Plasmonic Metal Oxide Nanocrystals)

  • 나장한;김성빈;허성연
    • 한국전기전자재료학회논문지
    • /
    • 제37권1호
    • /
    • pp.1-10
    • /
    • 2024
  • Direct use of sunlight through the glass windows is an efficient way to reduce the energy consumption related to the heating, cooling, and lighting. Introduction of near-infrared modulating properties through colloidal doped metal oxide nanocrystals into the classical electrochromic materials accelerates the development of next-generation electrochromic devices. There has been a steady enhancement in the performance of electrochromic devices, necessitating a review of the recent progress in next-generation electrochromic devices employing doped metal oxide nanocrystals. This review provides an overview of the current developments in next-generation electrochromic smart windows utilizing colloidal doped metal oxide nanocrystals, with a focus on the key factors for achieving these advanced windows. Colloidal doped metal oxide nanocrystals are a crucial component in realizing and bringing to market the next generation of electrochromic windows, though further research and development are still required in this regard.

블라인드 내장형 창호시스템의 에너지 성능 및 경제성 평가에 관한 연구 (Study on Energy Performance And Economic Evaluation of Windows System with Built-in Type Blinds)

  • 조원화;임남기
    • 한국건축시공학회지
    • /
    • 제10권2호
    • /
    • pp.97-104
    • /
    • 2010
  • 본 연구에서는 전열해석 프로그램인 피지벨(PHYSIBEL)을 사용하여 블라인드 내장형 창호시스템의 일사차단성능 및 단열성능에 따른 에너지 성능을 평가하였다. 피지벨 해석시 창호별 구성 재료의 열적특성과 해석조건을 결정하기 위해서 Mock-up시험을 실시하였으며, 컴퓨터 시뮬레이션을 통한 결과를 바탕으로 공동주택 기준층 1개 세대(33평형)를 대상으로 연간에너지 소비특성, 연간전열량, 연간 냉난방 비용을 분석하였다. 실험결과, 연간전열량은 일반 창호시스템 대비 블라인드 내장형 창호시스템에서 블라인드를 올린 경우 냉방시 10%, 난방시 11% 절감할 수 있으며, 블라인드를 내린 경우 냉방시 25%, 난방시 30%정도를 절감할 수 있는 것으로 나타났다. 블라인드 내장형 창호시스템의 냉 난방 부하 절감량은 일반 창호시스템에 비해 냉방시 283.3KWh, 난방시 76.3KWh 로 냉 난방 에너지 절감효과는 단위세대당 359.6KWh 절감시킬 수 있는 것으로 나타났으며, 이것은 단위세대당 연간 에너지원단위(TOE) 약 0.078toe, 이산화탄소톤($tCO_2$) $0.16tCO_2$을 절감시킬 수 있어 온실가스 저감에도 유리할 것으로 판단된다. 또한, 블라인드 내장형 창호시스템의 냉 난방비용 절감액은 일반창호시스템과 비교하여 연간 냉방비용 10만원, 난방비용 5만원으로 연간 냉 난방 비용을 약 15만원 정도 절감시킬 수 있는 것으로 나타났다.

Windows Phone Platform 기반의 모바일 게임 설계 및 구현 (A Design and Implementation of Mobile Game Based on Windows Phone Platform)

  • 박진양
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권10호
    • /
    • pp.91-97
    • /
    • 2014
  • 본 논문에서는 Windows Phone 플랫폼 기반의 모바일 게임을 설계하고 구현한다. 이 게임은 비주얼 스튜디오와 윈도우 모바일 소프트웨어 개발 킷(SDK: Software Development Kit), 그리고 개발자 도구 킷(DTK Developer Tool Kit)으로 비주얼 C#언어를 사용하여 개발한다. 또한 게임 개발에 필요한 닷넷(.NET) 라이브러리의 집합인 XNA Framework를 사용한다. XNA Framework은 PC와 XBOX, ZUNE HD등 다중 플랫폼 환경을 지원하는 게임 개발 및 2D 및 3D 게임 개발에 필요한 기능들을 제공한다. XNA Framework를 사용하여 개발하기 때문에 상속받은 코드들을 자동으로 생성하고, 게임 개발 관련 리소스 및 게임 로직을 쉽게 구현할 수 있다. 이 게임의 특징은 슈팅(shooting), 이미지, 랭킹시스템 등의 3개 요소를 고려하여 개발한 것이다.