• Title/Summary/Keyword: winding methods

Search Result 143, Processing Time 0.021 seconds

A New Approach for Pulsating Torque Minimization of BLDC Motor

  • Lee, Young-Jin;Lee, Man-Hyung;Park, Sung-Jun;Park, Han-Woong
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.831-838
    • /
    • 2001
  • Torque ripple control of brushless DC motor has long been the main issue of the servo drive systems in which the speed fluctuation, vibration and acoustic noise need to be minimized. The vast majority of the methods for suppressing the torque ripple require the Fourier series analysis and either the iterative or least mean square minimization. In this paper, a novel approach based on the d-q-0 reference frame that achieves ripple-free torque control with maximum efficiency is presented. The proposed method optimizes the reference phase current waveforms including even the case of 3-phase unbalanced condition, and the motor winding currents are controlled to track the optimized current waveforms by the delta modulation technique. As a results, the proposed approach provides a simple and yet effectine means for obtaining the optimal motor excitation currents. The validity and applicability of the proposed control scheme are verified through simulations and experimental investigations.

  • PDF

Primary side control of Flyback converter using sawtooth wave (톱니파를 이용한 플라이백 컨버터의 일차 측 제어)

  • Nam, Sang-Guk;Kim, Ki-Hyun;Kim, Min-Sung;Seo, Kil-Soo;Kim, Nam-Kyun;Song, Han-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.932-933
    • /
    • 2015
  • This paper presents methods to achieve and control accurate output voltage. PSR removed secondary output voltage sensing circuit, therefore standby power loss can be decreased. When sensing the auxiliary winding voltage, sensing must be done at accurate branch which has $V_O$ information. For this reason this paper presents the PSR sensing technique using sawtooth wave and peak detector. Circuit verification carried out with Spectre in Cadence corporation and Manga/Hynix $0.35{\mu}m$ 700V process.

  • PDF

Inner Evaporative Cooling Wind Power Generator with Non-overlapping Concentrated Windings

  • Li, Wang;Wang, Haifeng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.15-19
    • /
    • 2014
  • As the space of the wind power generator stator end is limited, it is difficult for us to place the inner evaporative cooling system in it. We use the non-overlapping concentrated windings scheme to solve the placing and cooling problem. The characteristic of a 5MW direct-driven permanent magnet generator with non-overlapping concentrated windings were analyzed under no-load, rating-load and short-circuit by (Finite Element Method) FEM for verification of design. We studied the connection methods of the stator windings and designed the end connection member. The heat dissipation of the stator end was simulated by FEM, the result showed that the end cooling could satisfy the wind generator operation needs. These results show that the direct-driven permanent magnet wind power generators with non-overlapping concentrated windings and inner evaporative cooling system can solve the cooling problem of wind power generator, and obtain good performance at the same time.

A Technique for Removing Adjacent Induction Noise Mixed with Partial Discharge Signals of High Voltage Rotating Machines (고압 회전기 부분방전 신호에 혼합된 인접상 유도 잡음 제거 기법)

  • Youn, Young-Woo;Yi, Sang-Hwa;Hwang, Don-Ha;Choo, Young-Bae;Kang, Dong-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.335-341
    • /
    • 2009
  • Analysis of the partial discharge signal, a technique to diagnose the stator winding insulation is a key function for the diagnosis of high voltage rotating machines and requires high precision. To satisfy this requirement, various denoising techniques such as filtering and differential methods were proposed. However, these techniques can not eliminate a adjacent induction noise that decreases reliability of the diagnosis. A simple novel denoising algorithm, therefore, is proposed for removing the adjacent induction noise in this paper. The algorithm shows good performance in the real partial discharge signals measured by 13kV class capacitive couplers installed at hydro-generator in Dae-cheong Dam.

Synchronizing Characteristics of the Linear Induction Synchronous Motor (영구자석형 리니어 유도 동기모터의 동기화에 관한 실험적 검토)

  • Jeon, Woo-Jin;Lee, Ju;Jeon, Hye-Jeong;Kamiya, Vushi
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.972-974
    • /
    • 2000
  • In this paper, we describe the starting and synchronizing methods in the linear induction synchronous motor. The proposed motor consists of one pair of linear synchronous motors (LSMs) and an additional linear induction motor (LIM). The primary cores have a common ring winding, and solid conductors are arranged in both LIM and LSM. From the investigation by analysis and experiment, we verify that the proposed motor is effective for practical use.

  • PDF

FEM을 이용한 몰드변압기의 예방진단에 관한 연구

  • 청영기;정종욱;최명준;김재철;박일한;곽희로
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.70-73
    • /
    • 1997
  • This paper describes the technique for detecting failure symptom of mold transformer. This study uses the vibration signal analysis method and FEM as the technique. A loading back method is constructed for experiment, accelation sensors are adhered for measurement of vibration signal. Vibration signal measured by this method is analyzed into variation trend of measurement variables by control of control variables. Magnetic field distribution of molded winding is also acquired by FEM considering the design specfication and the characteristics of insulation material, in conclusion, he relation of results between vibration signal and FEM is studied by these methods.

  • PDF

Development of the Controller for TFM with Contol-Rod (제어봉 구동장치용 횡자속형 전동기의 제어기 개발)

  • Kim J.M.;Jeong Y.H;Kang D.H.;Im T.Y.;Kim D.H.;Lee S.G.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.284-287
    • /
    • 2001
  • In the System-integrated modular advanced reactor(SMART), the motor for Control element drive mechanism(CEDM) requires high density power and simple drive mechanism to reduce volume because of restriction by install-space and must satisfy the reactor operating circumstances with high pressure and temperature. To Maximize the characteristics of the TFM, we chose the asymmetric bridge converter as the driving system for TFM. Because two switching devices are connected in series with the stator winding of each phases in the asymmetric bridge converter all the phases are not affected by another phase but controlled independently. Also, this converter has many advantages that the various control methods can be adopted, it is easy to control, and that in case that the switching devices of a phase are damaged, the affects can be minimized.

  • PDF

Analysis of Transformer Fluid Aging from Overload Operation (과부하에 따른 배전용 변압기의 절연유 열화검출)

  • Joung, Jong-Man;Lee, Byung-Sung;Kim, Ju-Yong;Song, Il-Kun;Kim, Byung-Suk
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.49-53
    • /
    • 2006
  • In this paper the thermal aging characteristics of transformer fluid were considered. First, the temperature rise characteristic in transformer winding was discussed. The temperatures were rapidly increased immediately with applying load and then the temperature was followed the exponential temperature rise model. Next, Capacitance and leakage current characteristics of the transformer fluid were measured during the over-loading operation. The capacitance of vegetable fluid and leakage current were evidently increased wit aging time. So the simple methods could be applied to diagnosis of the transformer aging

  • PDF

Field analysis of end_turn coil of HV induction motor (고압 회전기에서 코일 단부의 전계 해석)

  • Park, Seung-Bae;Kim, Do-Wan;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.70-72
    • /
    • 1998
  • Because of using PWM inverters and converters. The problems of insulation breakdown is emerging in both high voltage motors and general motors. In conventional methods, the viewpoint of surge problems is wave propagation with or without cable and inverter. For the purpose of knowing the situation of insulation breakdown, the end-turn coil of windings in the motor winding insulation structure is modelled by FEM, and field analysis of that is done. For first step, only end-turn coil is modelled and the model is simulated with FEM by approximating the resistivity of metallic foil surrounding insulation layers with having nonlinear property. Next, the result of simulation with nonlinear resistivity are compared with the result of linear resistivity. Because of microscope analysis, there is the problem of generalization but the situation of corona discharge in end-turn coil will be explained from this simulation.

  • PDF

Dynamic Characteristics Analysis of Filament-wound Composite Towers for Large Scale Offshore Wind-Turbine (대형 해상풍력발전용 필라멘트 와인딩 복합재 타워의 동적 특성에 관한 연구)

  • Han, Jeong-Young;Hong, Cheol-Hyun;Jeong, Jae-Hun;Moon, Byong-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.4
    • /
    • pp.55-60
    • /
    • 2012
  • The purpose of this study is to investigate the buckling load of filament-wound composite towers for large scale wind-turbine using finite element method(FEM). To define material properties, we used both the effective property method and the stacking properties method. The effective properties method is to assume that composite consists of one ply. The stacking properties method is to assume that composite consists of some stacked plies. First, linear buckling analysis of the tower, filament-wounded with angles of [${\pm}30$] was carried out by two methods for composite material properties, the stacking method and the effective method. and FE analysis was performed for the composite towers according to filament winding angles of [${\pm}30$], [${\pm}45$], [${\pm}60$]. FE analysis results using the stacking properties of the composite were in good agreement with the results by the effective properties. The difference between FEM results by material properties methods was approximately 0~2.3% in buckling Analysis and approximately 0~0.6% in modal analysis. And above the angle of [${\pm}60$], there was a little change of buckling load.