• 제목/요약/키워드: wind speed limit

검색결과 64건 처리시간 0.021초

타워크레인의 작업 중지 풍속에 대한 현장 실태 조사 연구 (Field Survey on Suitable In-service Wind Speed Limit for Tower Crane Operation)

  • 이의주;신성우
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.103-108
    • /
    • 2018
  • Since tower cranes are susceptible to wind loads, the operation of the tower crane should be ceased when it exposed to a strong wind. For this reason, even in Korea, the operation limit for wind loading on the tower crane is regulated by a law. Recently the Korean law in which provided the wind speed limit to cease the tower crane operation has been revised from "instantaneous wind speed of 20 m/s" to "instantaneous wind speed of 15 m/s". Although this revision is expected to reduce safety risks in tower crane operation, some field operators still insist to lower the wind speed limit. However, in many countries "wind speed of 20 m/s" is normally used as the maximum in-service wind speed for tower cranes. Therefore, the investigation of the proper wind speed for regulation would be helpful to secure the safety of the tower crane operation under windy condition. In this study the validity of the revised wind speed limit is investigated with the surveys targeted to both tower crane practitioners and parties of concerned in construction companies, in which various questions was provided for a suitable wind speed limit and the answers were analyzed. The results showed that the revised wind speed limit is acceptable to tower crane practitioners as well as the parties of concerned in construction companies and is satisfying the structural stability requirement for in-service state tower crane. Therefore, it can be concluded that the revised wind speed limit is valid in humanly safety point of view.

속도 오버슈트 발생 시 제한 속도를 초과하지 않는 실속형 블레이드 풍력터빈의 속도제어기 설계 (Design of Speed Controller for Stall Blade Wind Turbine Complying with the Speed Limit During Speed Overshoot)

  • 김예찬;송승호
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.438-445
    • /
    • 2022
  • Blade efficiency decreases when the rotor speed is kept constant even though the wind speed is higher than the rated value. Therefore, a speed controller is used to regulate the rotor speed in the high-wind-speed region. In stall-blade wind turbine, the role of the speed controller is important because precise aerodynamic regulation is unavailable. In this study, an effective parameter design method of a PI speed controller is proposed to limit the speed overshoot of a type 4 wind turbine with stall blades even though wind gust occurs. The proposed method considers the efficiency characteristics of the stall blade and the mechanical inertia of the wind turbine rotor. It determines the bandwidth of the speed controller to comply with the speed limit during generator speed overshoot for the worst case of wind gust. The proposed method is verified through intensive simulations with a MATLAB/SIMULINK model and experimental results obtained using a 3 kW MG set of wind turbine simulator.

화물차량의 사고위험도 분석 및 통행속도 제한기준 정립 (Establishing Traffic Speed Limits Standard and Accident Risk Analysis of Truck)

  • 김재현;홍기남;서동우
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.149-157
    • /
    • 2016
  • This paper presents the traffic speed limit of heavy vehicles at each wind velocity region, which is based on their accident risk analysis under cross-wind. The variables for the accident risk analysis are overall height, overall length, intake weight, and friction coefficient of the road surface. It was confirmed from analysis results that the risk of overturning increased with higher overall height and length, and the risk of sliding decreased with higher intake weight. The risk of sliding was largest at the friction coefficient of 0.1, and the risk of overturning was lagest at friction coefficient more than 0.25. Finally, traffic speed limit was proposed by using the accident risk analysis.

풍력발전기 모델링 및 리미트 MPPT제어기에 관한 연구 (Study on a Limit MPPT Controller for the Modelling of a Wind Power Generator)

  • 강주성;고강훈;최광주;박재윤
    • 조명전기설비학회논문지
    • /
    • 제21권5호
    • /
    • pp.53-59
    • /
    • 2007
  • 현재 화석연료에만 의존하는 에너지 시장을 변화시키고자 하는 연구가 활발히 이루어지고 있는 가운데 신재생에너지(연료전지, 풍력, 태양광 등)를 복합적으로 활용한 분산전원시스템에 관한 관심이 증가하고 있다. 이 가운데 풍력 발전시스템은 발전효율, 가격 측면 등에 있어 많이 연구되고 있다. 그러나 풍력발전시스템의 경우 난류가 되기 쉽고, 풍향이나 풍속이 수십초의 간격으로 변화하기 때문에, 바람의 에너지를 최대한 이용하는 최대전력점추종(MPPT)제어기의 역할이 가장 중요하다. 본 논문에서는 풍속과 풍차, 전력에 관한 정보를 사용하는 것으로 이전방식보다 간단한 MPPT를 제안하였다. 제안한 제어기는 시뮬레이션을 통하여 정격속도와 가변속도에서 항상 전력의 최대전력점에서 제어기가 동작하고 있다는 것을 검증하였다.

풍속 감소 시 Over-Deceleration 방지를 위한 DFIG 풍력발전기의 계단형 출력 관성제어 (Stepwise inertial control of a DFIG to prevent the over-deceleration in wind speed reduction)

  • 강모세;이진식;강용철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.173-174
    • /
    • 2015
  • If a wind speed decreases during inertial control of a wind turbine generator (WTG), the rotor speed might decrease below the minimum operating limit, which is called over-deceleration (OD). When OD occurs, inertial control should be disabled and then the output power of a WTG significantly decreases. This significant power reduction causes a subsequent frequency drop. This paper proposes the stepwise inertial control to prevent OD when a wind speed decreases during inertial control. To do this, the proposed scheme changes the additional power output based on the rotor speed. The performance of the proposed scheme is investigated using an EMTP-RV simulator. The results show that the proposed inertial control scheme prevent OD even when the wind speed decreases during inertial control.

  • PDF

에너지저장장치를 이용한 제주지역 풍력발전 한계용량 증대효과 분석 (Increasing Effect Analysis of the Wind Power Limit Using Energy Storage System in Jeju-Korea)

  • 김영환;김세호
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.81-90
    • /
    • 2014
  • The Jeju-Korea power system is a small-sized network with a system demand ranging from a autumn minimum of 350MW to a summer peak of 716MW. Because Jeju island is well exposed to north-east winds with high speed, applications to connect to Jeju power system are flooded. Considering physical/environmental constraints, Jeju Self-governing Province has also target for the wind power capacity of 1,350MW by 2020. It amounts to two or three times of Jeju average-demand power and wind power limit capacity announced by Korea Power Exchange (KPX) company. Wind farm connection agreements will be signed to maximize utilization of wind resource. In spite of submarine cable HVDC connected to Korea mainland, Jeju power system is independently operated by frequency and reserve control. This study reevaluates wind power limit based on the KPX criteria from 2016 to 2020. First of all wind power generation limit are affected by off-peak demand in Jeju power system. Also the possibility capacity rate of charging wind power output is evaluated by using energy storage system (ESS). As a result, in case of using 110MWh ESS, wind power limit increases 33~55MW(30~50% of ESS), wind power constraint energy decreases from 68,539MWh to 50,301MWh and wind farm capacity factor increases from 25.9 to 26.1% in 2020.

Wind fragility analysis of RC chimney with temperature effects by dual response surface method

  • Datta, Gaurav;Sahoo, Avinandan;Bhattacharjya, Soumya
    • Wind and Structures
    • /
    • 제31권1호
    • /
    • pp.59-73
    • /
    • 2020
  • Wind fragility analysis (WFA) of concrete chimney is often executed disregarding temperature effects. But combined wind and temperature effect is the most critical limit state to define the safety of a chimney. Hence, in this study, WFA of a 70 m tall RC chimney for combined wind and temperature effects is explored. The wind force time-history is generated by spectral representation method. The safety of chimney is assessed considering limit states of stress failure in concrete and steel. A moving-least-squares method based dual response surface method (DRSM) procedure is proposed in WFA to alleviate huge computational time requirement by the conventional direct Monte Carlo simulation (MCS) approach. The DRSM captures the record-to-record variation of wind force time-histories and uncertainty in system parameters. The proposed DRSM approach yields fragility curves which are in close conformity with the most accurate direct MCS approach within substantially less computational time. In this regard, the error by the single-level RSM and least-squares method based DRSM can be easily noted. The WFA results indicate that over temperature difference of 150℃, the temperature stress is so pronounced that the probability of failure is very high even at 30 m/s wind speed. However, below 100℃, wind governs the design.

Fragility curves for woodframe structures subjected to lateral wind loads

  • Lee, Kyung Ho;Rosowsky, David V.
    • Wind and Structures
    • /
    • 제9권3호
    • /
    • pp.217-230
    • /
    • 2006
  • This paper describes a procedure to develop fragility curves for woodframe structures subjected to lateral wind loads. The fragilities are cast in terms of horizontal displacement criteria (maximum drift at the top of the shearwalls). The procedure is illustrated through the development of fragility curves for one and two-story residential woodframe buildings in high wind regions. The structures were analyzed using a monotonic pushover analysis to develop the relationship between displacement and base shear. The base shear values were then transformed to equivalent nominal wind speeds using information on the geometry of the baseline buildings and the wind load equations (and associated parameters) in ASCE 7-02. Displacement vs. equivalent nominal wind speed curves were used to determine the critical wind direction, and Monte Carlo simulation was used along with wind load parameter statistics provided by Ellingwood and Tekie (1999) to construct displacement vs. wind speed curves. Wind speeds corresponding to a presumed limit displacement were used to construct fragility curves. Since the fragilities were fit well using a lognormal CDF and had similar logarithmic standard deviations (${\xi}$), a quick analysis to develop approximate fragilities is possible, and this also is illustrated. Finally, a compound fragility curve, defined as a weighted combination of individual fragilities, is developed.

10MW급 해상풍력발전기 드라이브 트레인을 위한 마그네틱 기어의 속도별 설계 및 출력밀도 특성분석 (Power Density Characteristics Analysis and Design of Magnetic Gear according to Speed for Drive Train of 10MW Offshore Wind Turbine)

  • 김찬호;김용재
    • 전기학회논문지
    • /
    • 제64권12호
    • /
    • pp.1718-1723
    • /
    • 2015
  • The diameter of the rotor of 2MW wind turbine is being developed by a number of companies with more than 80m, reliability and economic efficiency of the wind power generator has been improved. The need for large-scale wind turbine with excellent economy has been attracting attention because the new orders and the location of the wind turbine market has reached a limit. Technology development for enlargement of wind turbine is possible not only the improvement of energy efficiency but also reduce the construction costs per unit capacity. However, mechanical gearboxes used in wind generators have problems of wear, damage, need for lubrication oil and maintenance. Therefore, we want to configure the gearbox of a large-scale wind turbine using a magnetic gear in order to solve these problems of mechanical gearbox.

오염물질 이동 추적을 위한 SF6 추적자 실험 분석과 모사 연구 (Analysis and Simulation of SF6 Tracer Experiments for Tracking the Pollutant Transport)

  • 김영성;조성호
    • 한국대기환경학회지
    • /
    • 제14권5호
    • /
    • pp.397-410
    • /
    • 1998
  • Tracer experiments were performed 4 times in December 1992 on the relatively flat terrain and nearby building area adjacent to the Taedok Science Town in Korea. Each experiment was continued for relatively short period of 1 or 2 hours with intermittent release of SF6 up to 2.07g/s at 10m height. Movement of tracer plume was tracked by a continuous tracer analyzer installed on an air monitoring van. Simulation with INPUFF was carried out to analyze and predict experiments. Measured profiles of tracer plume were narrow and sharp while predicted profiles by INPUFF were broad and slowly varied. Tracer plumes were detected at a short distance of 0.5 to 2.2 km mainly due to intermittent release and high value of lower detectable limit. Various experimental conditions were tested by INPUFF simulation in order to find desirable conditions. Higher wind speed and less variable wind direction could yield longer distance of plume tracking only when the lower detectable limit was sufficiently low. Distance of plume tracking was long and did not much depend on the lower detectable limit in stable atmospheric conditions.

  • PDF